Loading...
IM Inspection Worksheet_07-12-2023_15-18-03INSPECTION WORKSHEET (RESFINAL-029211-2023) RC-0578-2022Case Number:Case Module:Permit Management 12/07/2023 Partial PassInspection Status:Inspection Date: Residential Final InspectionInspection Type:Inspector:Charles Dyer Job Address:Parcel Number:42 Farr Ln Queensbury, NY 12804 295.20-1-4.2 Company Name NameContact Type Applicant RICHARD SPOERL Contractor David Howard Jr Engineer Engineering America Company Granted Permission RICHARD SPOERL Primary Owner RICHARD SPOERL Checklist Item CommentsPassed Low flow toilet 1.3 gal/flushing cycle False Bathroom Fans, if no window True 3" Plumbing Vent through roof minimum 18 inch True Grade away from foundation: 6" down, 10' out True Final Survey Plot Plan False to be provided Window guards req:<2' above floor/6' above grade True Interior privacy/trim/doors/main entrance 36 False Backflow Preventors where required True Basement wall insulation R- value verified False Emergency egress below grade True Intake Openings False Safety glazing: w/in 5' of tub/shower True Seals on Garage Doors, esp. Wood True Not less than 3' horiz from opening of bthrn True Basement ceiling covered 2x8 fl joist or less False N/A Attic Access Insulation = Attic R- Value True Gas Shut-off Exposed & Regulator 12" min abv grd True Platform at all exterior doors True Garage Floor Pitched True Inter Connected True Arc Fault Breaker Habitable Spaces True Dryer Duct Max Length 35', Labeled Over 35'False Energy Sticker on Elec. Panel:R-Val. & Heating Sys True Furnace/Hot Water Heater operating True hot water Fresh Air Intake False Chimney Rain Cap Installed True Basement stairs closed rise greater than 4 inches False to be provided Foam in basement/attics covered w/thermal barrier False N/A Outside every bedroom area True December 07, 2023 Page 1 of 3 INSPECTION WORKSHEET (RESFINAL-029211-2023) Checklist Item CommentsPassed Blower Door Test Certification False to be provided Fin Elect; Energy Saving Light Bulbs 90 Percent True Heat detector in garage True Gas Log In Sealed or Glass Enclosure True need to verify operation for final OK to Issue C/O False Truss ID Signage Installed at Electrical Meter False Range Hood 400+ cfm-Fresh Air REQUIRED False 4 inch Building Number Address visible from road False CO in bedrooms w/gas appliances False Attic Access Gasketed True Jack posts in basement lagged at top and bottom True 6" clearance to sill plate True Crawl space/knee wall access insulated & gasketed False 20 Minute Fire Door/Self-Closing Hardware True Every level, Every bedroom True Furnace shut-off w/in 30 ft. or w/in line of site False N/A Chimney Height / B Vent / Direct Vent Location True within 10' of all sleeping areas True on all levels w/gas appliances (i.e. furnace)True Relief Valve ,Heat Trap/Water Temp 110 deg or less True 1/2" Gypsum or House Wall and Gable True Basement Egress: 5s.f. window w/sill or Bilco door True Bathroom / Kitchen Watertight False Fresh air supply 3' from grade False Pull down stairs boxed out and insulated False OK to Issue Temporary C/O True ok to issue temp C/O General Comments True Walk through for list of items to be completed for Temp C/O at this time Conditions for Temp C/O 1. provide final survey 2.provide blower door test results 3. complete HRV 4. complete exterior 5. provide truss ID Foundation insulation to floor False Carbon Monoxide Detectors:True Duct work sealed properly False N/A Flex Gas Pipe Bonding True HRV or ERV Installed per Bedroom Requirements False to be provided Smoke Detectors:True Battery backup True Attic Access 22 x 30 minimum True Roof Complete / Exterior Finish Complete True As Built Septic System False to be provided Outside Spigots have Air Gap True Encl. Stairs Sheetrock Underside minimum ½ Gypsum False Handrail 4 or more risers False provide handrail at basement stairs as discussed December 07, 2023 Page 2 of 3 INSPECTION WORKSHEET (RESFINAL-029211-2023) Checklist Item CommentsPassed Guard at stairwell at 34" or more True Interior/Exterior Railings 34 to 38 False Handrail Termination at Newell Post or Wall False All Hot Water Systems: 3/4" or larger piping R-3 False Plumbing fixtures False December 07, 2023 Page 3 of 3