Signed Inspection Worksheet (02-16-2018) IIIIIIIIIIIIIIIIIIIIIIIII� �IIIIIIIIIIIIIIIIIIIIIII I ���� ® I I I IIIIIIII A4 A4 A4 � A4 f Ill�illlllillllll IIIIIIIIIIII illllllllllllllllllllllllu IIIIIIII Il�llllllllul IIIIIIIIIIIIIII IIIIIIIIIII Illllllullllllllll�llullll IIIIIIII IIIIIIIIIVIIIIII IIIIIIIIIIIII �� Town of Queensbury-Building and Codes-Fire Marshal 742 Bay Road-(518)761-8256 Building(518)761-8206 Fire Marshal Case Number: RC-000718-2017 Case Module: Permit Inspection Date: 02/16/2018 Inspection Status: Partial Pass Inspector: John O'Brien Inspection Type: Rough Plumbing Job Address: 74 JOHN CLENDON RD Parcel Number: 295.15-2-7 Queensbury, NY 12804 Contact Type Company Name Name Applicant [FOOTHILLS BUILDERS, LLC] Contractor [FOOTHILLS BUILDERS, LLC] Primary Owner [FOOTHILLS BUILDERS, LLC] Granted Permission [FOOTHILLS BUILDERS, LLC] Checklist Item Passed Comments Building Inspector Notes YES 2/16/18 Plumbing Partial Approval Remaining Item: -Complete all final connections Rough Plumbing/Nail Plates YES Plumbing Vent Vents in Place YES 3"Vent Through Roof YES 1 '/2 inch minimum Drain Size 41111 YES Washing Machine Drain 2 inch minimum YES Washing Machine Trap: 18...-24... discharge YES Cleanout every 100 feet change of direction YES Pressure Test YES Pressure Test YES Drain Vent YES 5 psi or 10 ft.above highest c o n n..........for 15 minutes YES Water Supply Piping YES Air Head YES Air Head YES 50 P.S.I for 15 minutes YES Air Test Gas Piping 10 psi for 10 Minutes NO All Return Air Hard Duct Work NO Duct Insulation-if required in unheated spaces NO Duct Testing Outside Conditioned Space NO Duct work sealed properly NO O'Brien,John(Inspector) Feb 16,2018 Page(3)