Signed Inspection Worksheet (02-16-2018) IIIIIIIIIIIIIIIIIIIIIIIII� �IIIIIIIIIIIIIIIIIIIIIII I ����
® I I I IIIIIIII A4 A4 A4 � A4 f
Ill�illlllillllll IIIIIIIIIIII illllllllllllllllllllllllu IIIIIIII Il�llllllllul IIIIIIIIIIIIIII IIIIIIIIIII Illllllullllllllll�llullll IIIIIIII IIIIIIIIIVIIIIII IIIIIIIIIIIII ��
Town of Queensbury-Building and Codes-Fire Marshal
742 Bay Road-(518)761-8256 Building(518)761-8206 Fire Marshal
Case Number: RC-000718-2017 Case Module: Permit
Inspection Date: 02/16/2018 Inspection Status: Partial Pass
Inspector: John O'Brien Inspection Type: Rough Plumbing
Job Address: 74 JOHN CLENDON RD Parcel Number: 295.15-2-7
Queensbury, NY 12804
Contact Type Company Name Name
Applicant [FOOTHILLS BUILDERS, LLC]
Contractor [FOOTHILLS BUILDERS, LLC]
Primary Owner [FOOTHILLS BUILDERS, LLC]
Granted Permission [FOOTHILLS BUILDERS, LLC]
Checklist Item Passed Comments
Building Inspector Notes YES 2/16/18 Plumbing Partial Approval
Remaining Item:
-Complete all final connections
Rough Plumbing/Nail Plates YES
Plumbing Vent Vents in Place YES
3"Vent Through Roof YES
1 '/2 inch minimum Drain Size 41111 YES
Washing Machine Drain 2 inch minimum YES
Washing Machine Trap: 18...-24... discharge YES
Cleanout every 100 feet change of direction YES
Pressure Test YES
Pressure Test YES
Drain Vent YES
5 psi or 10 ft.above highest c o n n..........for 15 minutes YES
Water Supply Piping YES
Air Head YES
Air Head YES
50 P.S.I for 15 minutes YES
Air Test Gas Piping 10 psi for 10 Minutes NO
All Return Air Hard Duct Work NO
Duct Insulation-if required in unheated spaces NO
Duct Testing Outside Conditioned Space NO
Duct work sealed properly NO
O'Brien,John(Inspector)
Feb 16,2018 Page(3)