Town of Queensbury-Building and Codes-Fire Marshal
742 Bay Road-(518)761-8256 Building(518)761-8206 Fire Marshal
Case Number: RC-000718-2017 Case Module: Permit
Inspection Date: 01/19/2018 Inspection Status: Partial Pass
Inspector: Charles Dyer Inspection Type: Building Framing
Job Address: 74 JOHN CLENDON RD Parcel Number: 295.15-2-7
Queensbury, NY 12804
Contact Type Company Name Name
Applicant [FOOTHILLS BUILDERS, LLC]
Primary Owner [FOOTHILLS BUILDERS, LLC]
Granted Permission [FOOTHILLS BUILDERS, LLC]
Contractor [FOOTHILLS BUILDERS, LLC]
Checklist Item Passed Comments
Building Inspector Notes NO
Framing NO
Attic Access 22 x 30 minimum NO
Jack Studs Headers NO
Continuous Header for Garage Doors with Straping NO
Truss Specification Provided NO
Bracing Bridging NO
Hurricane Clips/Uplift Screws/Nail Holes Filled NO
Air Seal all Plates and Sills NO
Air Seal All Registers at Floor NO
Air Sealing all Joints Before Insulation NO
Joist hangers NO
Jack Posts Main Beams NO
Exterior sheeting nailed properly NO
12 O.C. NO
Headroom 6 ft.8 in. NO
Notches Holes Bearing Walls NO
Metal Strapping for Notches Top Plate NO
Draft stopping 1,000 sq.ft floor trusses NO
Anchor Bolts 6 ft or less on center NO
Ice and water shield 24 inches from wall YES Partial only for front 1/11/17
For remainder approved 1/19/18
Soffits-Insulation Baffel NO
Windows Habitable Space Bedrooms NO
24 in. (H) NO
20 in. (W) NO
5.7 sf above below grade NO
5.0 sf grade NO
Design Professional Sign-off,if required NO
Dyer, Charles(Inspector)
Jan 19,2018 Page(1)