Loading...
IM Inspection Worksheet_20-12-2023_13-10-23INSPECTION WORKSHEET (PTI-029456-2023) PT-0410-2021Case Number:Case Module:Permit Management 12/20/2023 FailedInspection Status:Inspection Date: Property Transfer InspectionsInspection Type:Inspector:Charles Dyer Job Address:Parcel Number:66 Rockhurst Rd Queensbury, NY 12804 227.13-2-49 Company Name NameContact Type Applicant Gary Glomb Checklist Item CommentsPassed Watertight False Building Inspector Notes False 10/3/22 As per my preliminary visit to Gary Glomb's property at 66 Rockhurst Rd the following has been discussed and will be required. 1) A holding tank was installed back in in the late 80's early 90's without a septic system permit. It is believed it is a 1500 gallon concrete holding tank with traffic top. There is no alarm system or water shut off connected to the holding tank. 2) We will need to perform the property transfer inspection to verify the flow of all plumbing fixtures to the tank and then pump the tank to verify the size of the tank which is is somewhat full. 3) The inlet to the holding tank will need to have a traffic manhole cover installed to increase the size of the opening in order to inspect and complete installation of the alarm system with floats. 4) The alarm system and solenoid wiring will need to be inspected by a certified electrical inspector. Note: I will have a discussion with John Strough the Town Supervisor on whether we need to have Gary Glomb file for a septic system variance for a preexisting undersized holding tank with property line setback relief, or do we have him just install the proper alarm system and water shut off due to proposed Rockhurst community septic system to be installed in the near future. Weather/lack of information/inaccessibility False Holding tank (if yes, include capacity)True - Holding Tank needs to have an alarm system with solenoid water shutoff installed and an electrical system performed. New 1500 gallon precast holding tank see permit # 130-2023 variance. Capacity in gallons False System/components indicate unacceptable False Is there a high water alarm?False Roof gutters don't discharge over leach field False Concrete tank True Temperature (Fahrenheit)True 50 degrees / 12/20/23 30+ D-box material: concrete or plastic False Baffle & D-box or 45° angle False Apparent structural damage False Visible scum layer False Septic tank (include # of tanks)False Number of tank compartments False Plumbing fixtures tested & confirmed False December 20, 2023 Page 1 of 3 INSPECTION WORKSHEET (PTI-029456-2023) Checklist Item CommentsPassed Evidence of a pipe bypassing tank False Holding Tank:verify level rises; cap. w/in 250 gal True 1500 gallon Metal septic/leech/cesspool (auto fail, if yes)False Whirlpool tub add 250 gal False System appears undersized/undersized components False Foundation drain(s)False Verify 50% & 90% floats True Speed levers in D-box False Is there evidence of surface water infiltrating False Stormwater False Septic tank for bdrms/whrlpl/grndr w/in 250 gal False Garbage grinder add 250 gal False Tank cover True steel / traffic rated System appears to have functioned adequately False System passes all function testing False No running water 12/20/23 Does the pump(s) appear to be operating properly?False Surface discharge? (if yes, to where?)False Roof runoff False Septic outlet cover ext - Req 12"+ below grade False N/A System needs repairs False 9/20/21. Owner to submit for variance for holding tanks and ask for Extention to not loose deposit before 10/20/21 Sump pump not connected to septic system False Sand filter False Absorption bed False Outflow line invert above leach line invert(s)?False Depth below grade to top of tank False Evidence of prolonged high liquid level False Access riser? (if yes, depth to cover)False Inlet baffle True Recommend upgrade/expand/replace 1+ components False No treatment tank/other critical component(s)False Number of drop box(es)False As-built provided is accurate False Mound system False Excavate 18" around,no leach field connected False Test each fixture flow to septic tank False no water / observed anti freeze in toilet, did not want to pursue Sump pump(s)False Are both switch and alarm operable?False Liquid level AT/ABOVE/BELOW (one) discharge invert False Other False Dosing or pump tank sealed False Cracked, corroded or deformed?False Outlet baffle False N/A December 20, 2023 Page 2 of 3 INSPECTION WORKSHEET (PTI-029456-2023) Checklist Item CommentsPassed Weather True Clear / 12/20/23 sunny Main tank cleanout size and location False Water tight tank False Cracked, corroded or deformed?False Is tank pumped more than 4x/year?False On-site as-built req'd before insp is complete False Seepage Pits: Number False Evidence of liquid above outlet inverts?False Other False Raised system False Leaking water fixtures False Solids in D-box False Are there any obvious electrical shortcomings?False Absorption field False Water softener not connected to septic system False Ejector or grinder pump sealed False December 20, 2023 Page 3 of 3