Loading...
RC-0360-2022 1 Office Use Only c„..._• PRINCIPLE STRUCTURE ' ' Permit#: 0 6.0 - Z�}ZZ. ''''';, •. -':4%-;:,-.1 _ PERMIT APPLICATION Permit Fee:$ 3b Z � ���� ft , n. I2,nrrshun _ 000 742 Bay Road,Queensbury, NY 12804 *Rec Fee:$ ) P: 518-761-8256 ,v, N::;,;eer r:?.;u(,.?F, Invoice#: 501-0 Flood Zone? Y l� Reviewed By(:)1 ' / Project Location: H 'TWin Mown prve Tax Map #: 30?,.9-1- 11 Subdivision Name: *TOWN BD.RESOLUTION 385-2020:$1000 recreation fee for new dwelling r : artddy gBile / o amity, multiplefamily, apartments,condominiums, townhouses,and/or manufac u} u s, t t obile homes. This is in addition to the permit fee(s). IIo�J JUN 0 9 2022 PROJECT INFORMATION: TOWN OF QUEENSBURY x Residential Commercial, Proposed Use: BUILDING&CODES Single-Family: _Two-Family _Multi-Family(#of units:_) 1. •Custom 2. _Modular(REQUIRED:NYS stamped engineered drawings of foundation plans) Townhouse Garage (#of cars .i _ �( g �) _Business Office Retail _Hotel/Motel _Industrial Heated Warehouse/Storage Building _Unheated Warehouse/Storage Building _Amusement Ride _Other(describe: ) MAIN STRUCTURE SQUARE FOOTAGE: GARAGE SQUARE FOOTAGE: 1ST floor: 255 1'floor: C(�J2S 2'floor: 2"d floor: 3rd floor: Total square feet: 9M Basement(habitable space): Total square feet: 2.555 Principle Structure Packet Revised August 2021 -. 9 r ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ o )aid 2. Proposed use of the building: ' ri,N\Ct1NA \r \C`.2X\C:e. 3. If Commercial or Industrial, indicate the name of the business: 4. Source of Heat: Gas Oil >( Propane Solar Other: (Fireplaces need a separate Fuel Burning Appliances&Chimney Application, one per appliance) 5. Are there any structures not shown on the plot plan? YES X NO Explain, if yes: 6. Are there any easements on the property?_YES X NO 7. SITE INFORMATION: a. What is the dimensions or acreage of the parcel? o 2, ackreS b. Is this a corner lot? YES )( NO �/ c. Will the grade be changed as a result of the construction? YES X NO d.What is the water source? X PUBLIC PRIVATE _WELL e.What type of wastewater system is on the parcel? SEWER )(PRIVATE SEPTIC DECLARATION: 1. I acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans, additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn, 30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100%of the fee is retained. 3. I certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances, and in conformance with localzoning regulations. 4. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a NYSlicensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: (ic c:C\� OrW-"1(\ SIGNATURE: 9)f))€0.1.-k. � � DATE: I FIZZ Principle Structure Packet Revised August.2021 7 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): jes5ave. 'ekche \ J1/411c (Y c-e.\Che,n Mailing Address, C/S/Z: Z PVC OJ2S_r\Sbk)(`A 12SO(1 Cell Phone: (_ Slg ) -7 -I-I - 2,11 Land Line: ( ) Email: {e.'k CYNerN \(E (6c o \. CO`Or • Primary Owner(s): Name(s): 3essaVe_ 'Qe\Cren )Ax(1C R•eACiRer\ Mailing Address, C/S/Z: 23 Ve(Vncy,-� Ave vkLfl UYL( WI (2 c > Cell Phone: ( 51K ) 1 y u - 2-11 I Land Line: ( Email: { C.Vnern M @ roLA .('z`M El Check if all work will be performed by property owner only Contractor(s): (List all additional contractors on the back of this form) Contractor Name(s): Zit-ha-fa 1 t c Q,•r-e11 Contractor Trade: 13„;( ,yr Mailing Address, C/S/Z: 2152._ foil- Avn' tvy 1• 2-3?� Cell Phone: (5) ) 36( 0231 Land Line: ( ) Email: vrt ,tn 1M Y n4+1.A.L)'1oryY e.ao�r1aie , @drno-i 1 • CunA **Workers' Comp documentation must be submitted-Arith this application** • Architect(s)/Enciineer(s): Business Name: UCOr\ -:\ CL\\ a k-k_CA`/e Contact Name(s): E-k(\o in \Ack\l Mailing Address, C/S/Z: 1.' `- ON Nit t Q Oe-'s i,\5 ' z Q Cell Phone: I S1r ) Land Line: ( Email: e p\(1C \C3. Cap.,f r. C`(Y\ Contact Person for Compliance in regards to this project: (orc Malyr Cell Phone: ( ) Land Line: ( ) 174 Email: Principle Structure Packet Revised January 2021 Office Use-Only `. ' Permit#: 3ton. - 20 2rZ m;•:r ,,r ;r,,;:r,, Permit Fee:$ 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 -- Invoice#: Flood Zone? Y N Reviewed By: SEPTIC DISPOSAL PERMIT APPLICATION Project Location: )4 'TW � DAve GvstsiAi‘,Ni 0,\\ 12As6`\ Tax Map#: .9- I -II RESIDENCE INFORMATION: Year Built Gallons #of bedrooms: X gallons per =total daily flow per day bedroom Garbage Grinder Yes 1980 or older 150 Installed? (circle one) 1981-1991 130 Spa or Hot Tub Yes No Installed? (circle one) 1992-Present 110 110 3 0 PARCEL INFORMATION: Topography Flat Rolling Steep Slope %Slope Soil Nature Sand Loam _Clay _Other, explain: Groundwater At wh t depth? f Bedrock/Impervious At at depth? material Ai A Domestic Water Supply Municipal _Well _Lake (if well or lake, water supply from any septic system absorption is ft.) Percolation Test Rate:NA per minute per inch (test to be completed by a licensed engineer/architect) PROPOSED SYSTEM_INFORMATION: Tank size `5ed gallons (min. size 1,000 gallons, add 250 gallons for each garbage cylinder or spa/hot tub System Absorption field w/#2 stone Total length "51'+740 ft.; Each Trench_0 ft. Seepage Pit w/#3 stone How many: ; Size: Alternative System Bed or other type: Holding Tank System Total required capacity? ;tank size #of tanks NOTES: 1. Alarm system and associated electrical work must be inspected by a Town approved electrical inspection agency; 2. We will no longer allow systems to be covered until such time as an as-built plan is received and approved. The installed system must match the septic layout on file—no exceptions. 3. As- built drawings must be-submitted prior to the inspection, if there has been a-change to the submitted plans. Principle Structure Packet Revised January 2021 i CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL ❑ Check if all work will be performed by property owner only • Contractor: Contact Name(s): HQ E ) p-�' Contractor Trade: 5 ,i i S 6= Avon b Mailing Address, C/S/Z: f Cell Phone:_(J) ) 6l �q5( Land Line: ( ) Email: /1'7:' 7 ud m t/s /1o&10J z **Workers' Comp documentation must be submitted with this application** • Engineer(s): Name(s): Mailing Address, C/S/Z: Cell Phone:_( ) Land Line: _( Email: Contact Person fly Compliance inregards to this project: gx1 S1i Cell Phone: (l5'7 ) 3(of 0 re c 5 ' Land Line: ( ) Email: 5'4N Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: /' _� G510 7L SIGNATURE: DATE: Principle Structure Packet Revised January 2021 ,-:`zf ?- ` Office Use Only „ .:,, ±4%;' ex.— 0 b0 2022— ,_„ Permit#: 1nn•n of(?i' n.'iury Permit Fee:$ 742 Bay Road;Queensbury, NY 12804 P:518-761-8256 . _._ _.._ Invoice#: FUEL BURNING.APPLIANCE & CHIMNEY APPLICATION **ONE APPLICATION PER APPLIANCE** Project Location: ILA TW V\ 1 \O J( b Y\ Del Vt Tax Map ID It c. C) .CI - I —1 Room of Install: V A-c\ a '\ Planned Install Date: Oc„- 'O et 2.022- FUEL BURNING APPLIANCE INFORMATION: TYPE OF DEVICE: Stove _Fireplace Insert _Fireplace Fuel Fired Equipment (Garage Only, 18" clearance per IMC 304.3) Fireplace, factory built** (.**Manufacturer's name: \\O&c<'\O \ Model#: r O K 1 ` ) SOURCE OF HEAT: Wood Coal Pellet }( Gas CHIMNEY INFORMATION: Masonry(require plans to be submitted): block brick stone Flue: tile _steel _size, in inches _Material*: double-wall _triple-wall _insulated (*Manufacturer's name: Model#: ) Principle StructurePacket Revised January 2021 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL ❑ Check if all work will be performed by property owner only • Installer/Builder: Workers'Comp documentation must be submitted with this application Contact Name(s): Contractor Trade: Mailing_Address, C/S/Z: Cell Phone:_( ) Land Line: ( ). Email: Contact Person for any questions regarding this project: Cell Phone: ( ) Land Line: ( Email: ADDITIONAL INFORMATION: 1. Two (2) inspections are required. A rough-in inspection, prior to installation and a final inspection, after installation. 2. Manufacturer's installation manual must be available at the time of inspection. 3. Masonry fireplaces&chimneys require plans to be submitted. 4. Twenty-four(24) hour notification is required for inspections. 5. Workers' Comp insurance information is required with this application. Declaration: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations and all conditions that are part of these requirements and also will allow the inspector to enter the premises to perform the required inspections. I_have read and agree to the above: PRINT NAME: /11� 1 J. /te-d SIGNATURE: / �� C� DATE: 6/0 Principle Structure Packet Revised January 2021 Town of Queensbury �'``.`'- �`.°� �'�' �� David Duell Highway Superintendent ''�' "`�''�� '' :. 518-761-8212 Highway ' .�:-�,.:.. .,.:::= Department a' Typ`f' F Mark Benware 742 Bay Road—Queensbury, NY Deputy Highway Superintendent 12801 518-761-8210 Phone: (518) 761-8211 Fax: (518) 745-4466 DRIVEWAY PERMIT DATE: (c)11 t lO Z'Z APPLICANT NAME: ie.ssG.\te - e.kanec(1 FlodL R-6Chen TELEPHONE NO.: 1NLi- 211 ADDRESS TO BE INSPECTED: k4 v\i n MOQn--ek-w-. 0(w.e � `5 �1 2Z(A RETURN ADDRESS: Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes at the specified location. The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( ) Preliminary Approval NEED: ( ) Slight swale ( ) Deep swale ( ) Level with the.road ( ) Level with the top of the paved wing Size culvert pipe to be used (if necessary) ( ) 12" ( ) 15" ( ) 18" ( ) 24" ( ) 36" Preliminary inspection completed by: Date: Approval by Highway Supt: (or) Deputy Supt: Upon completion, please resubmit this approved permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: David Duell, Highway Superintendent Mark Benware, Deputy Highway Superintendent Principle Structure_Packet Revised January 2021 3(„0 --.20z.z. Residential Plan Review: 1- and 2- Family Dwellings Y/N/NA (1 of 2) -(?& Two (2)full sets of plans tj Over 1,500 sq. ft. requires engineering stamp e e,L Design loads on plans: 115 Wind Floor Loads 40 psf (North of Rte. 149 60) 50 Ground Snow Load Sleeping Areas &Attics 30 psf Calculations Decks 40 psf Wind design for lake front properties 7P Window schedule with glass size & main doors/Air leakage < .5 cfm for doors, < .3 cfm for • L windows/Tempered glass in bathrooms '/f Door schedule/Main entrance 36" door 16, Emergency Escape or Bedrooms & Habitable Space 1/ I Above-grade: 5.7 sq. ft. 1/6 Grade: 5.0 sq. ft. 24" (h) x 20" (w) minimum �` 44" maximum height above door Vt4 Window control devices 24" or less 2nd story or 72" above grade Egress window from basement 5.0 sq. ft. ft.iE,0 Floor system sizing per table 502.3.1 `P!� Residential check ERI or Prescriptive method Or Driveway length: 300' or more-12' width required/500' or more, turnaround required `t‘' Foundation drainage on plans, if required W6" drop in 10' exterior grade ���6 Framing/cross section for each roof line, vertical fire stopping every 10' where requiredjoist spans pg. 127 i�,�y Ice & snow shield—24"from exterior wall �je¢ Platforms at exterior doors 7',( Stairway headroom 6'8"; all stairs 36" width �rjStair run and rise /0 Winder run and rise IA Spiral stairs meet requirements Smoke detectors—battery backup & proper location, interconnected Bathroom fixtures—proper clearance 7ct: Hall width-36" width 2 Handrails more than four risers on open sides kRailing &guards >30"/basement stairs included/closed risers more than 4" in height 5 Safety glazing notes for required areas Garage fire separation: %" gable end/5/8" under living space &1/2" on walls/20 min. door pi.. )) and closer /11;i Garage floor sloped Attic access: gasket seal & R-value equal to roof insulation .-f Roof over 30"—22" x 30"/Crawl spaces 18" x 24" access Continued on back 4 4 Residential Plan Review Revised October 2021 Residential Plan Review: 1- and 2- Family Dwellings Y/N/NA (2 of 2) 1 Carbon Monoxide detector outside lowest sleeping area, on every level & interconnected within 15' of sleeping area `l/,_ Soil test results, if required P, Septic to well or water line separation All paperwork signed ���� ��,,, !� Note on plans energy saving light bulbs 90% ' % Blower door test agency paperwork `v. Floodplain Permit required—check map: 2 feet above flood elevation `��� Hurricane clips required )01 Floors less than 2 x 10 covered by%" gypsum or 5/8" wood panel Manuals S &J required for heating system. Cold air return hard piped A/A Separate room for draft HVAC or hot water heater with fresh air HRV shown and calculations Baffles at eaves for insulations and knee walls Makeup air for range hood 400 cfm (� Continuous header for garage doors to end wall IK21 Chimney rain cap shown for fireplaces Deck hold down shown not less than 4 lags and bolts per table 507.2 Residential Plan Review Revised October 2021 c tor ' TOWN OF UEENSB URY 742 Bay Road, Queensbury, NY. 12804-5902 Septic System Checklist K3Plan to scale ' is R eceived Deep hole perc test results from engineer/Architect if applicable(Town Approved Engineers and Architects;�.,hi June 30 to April 15 Town Engineer for unapproved Engineers and Architects) k "-93All wells on property and adjacent properties shown IAWater line shown Municipal or well 10'separation to any part of system //1-4 Setback to property lines show 10'or more for any part of system 16 Septic tank and pump stations 10'from foundation 50'from any well/lake/wetland 10' from any waterline \OA-Septic tank to foundation crawl space/slab on grade,grade in crawl space must be above top of septic tank for 0',Separation required (field verification required) �i �Septic tank sized for number of bedrooms and add 250 gals for Jacuzzi tubs/garbage grinder each 11Leech Field 20' from foundation 100'from any well 10'from water line LI ei Seepage pit 150'from well 50'from septic tank MA-Seepage Pits 3-times diameter apart 14, Septic tank and pump stations over 30 gallons 50'from watercourse or wetland - gdistance from bottom of trench or system 24"to bedrock or mottling 36"within 1000' of Lake George Leech field 100' from watercourse or wetland idIk Toe of mound or bottom of retaining wall 10' from property line 100'from well 20'from Foundation lProvide Engineer/Architect stamp for bed or design systems ,d,6 - / tADepartment of Health Approval for all mobile home park new systems Flood Plain requirements I03 2' above established flood elevation to bottom of system All tanks anchored or 2' above flood elevation Revised 4/15/2021 i Generated by REScheck-Web Software . r{1 Compliance Certificate N 0 00 1 M Q1 Project Reichen Residence v i. o Energy Code: 2018 IECC rtg Location: Glens Falls, New York------....__ 0S L- vi Construction Type: Single-family L" 4, `Tzp•--. iu 0 C in Project Type: New Construction -' a�na �.� ti;; ;• RI •f Conditioned Floor Area: 2,555 ft2 '��='• - 1--;:; ^' Glazing Area 17% JUN d 9 2022 i O a. Climate Zone: 6 (7635 HDD) i .. , C cv Permit Date: 7 0I4R1 '"^ w=v ,m C)f CiF=1 i sots (1) •C Permit Number: hU!LD;c'�'t ^COC U y O 5 0 Construction Site: Owner/Agent: • Designer/Contractor: , M CL t 14 Twin Mountain Drive Mark&Jessalie Reichen Ethan P. Hall Queensbury, NY 12804 23 Vermont Ave Rucinski Hall Architecture Queensbury, NY 12804 134 Dix Ave 518-744-2171 Glens Falls, NY 12801 Reichenm@gmail.com 518-741-0268 ephall@nycap.rr.com Compliance: Passes using UA trade-off' Compliance: 22.7%Better Than Code Maximum UA: 463 Your UA: 358 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelope Assemblies Gross Area Cavity Cont. Prop. Req. Prop. Req. Assembly or R-Value R-Value U-Factor U-Factor UA UA Perimeter Ceiling 1: Raised or Energy Truss 2,555 49.0 0.0 0.020 0.026 51 66 Wail 1: Insulated Concrete Forms 2,625 28.0 0.038 0.060 84 133 Door 2:Solid 18 0.300 0.300 5 5 Door 3:Solid 20 0.300 0.300 6 6 Door 1:Glass - 46 0.320 0.300 15 14 Door 4:Glass 18 0.320 0.300 6 5 Door 5:Glass 81 0.320 0.300 26 24 Window 1: Wood Frame:Double Pane with Low-E 227 0.290 0.300 66 68 Basement Wall 1: Insulated Concrete Forms • Wall height:9.0' 2,286 28.0 0.031 0.050 67 109 Depth below grade: 8.0' Insulation depth: 9.0' Door 7:Solid 23 0.300 0.300 7 7 Door 6: Solid 20 0.300 0.300 6 6 Window 2:Wood Frame:Double Pane with Low-E 66 0.290 0.300 19 20 Project Title: Reichen Residence Report date: 03/28/22 ' Data filename: Page 1 of10 Compliance Statement: The proposed bu dagde§ndembdhe@ §2nstnt with the building plans,specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IEC C requirements in REScheck Version : RE khe was and to comply with the mandatory requ -mew z -d<»he Scheck Inspect i Checklist. OeigZ EthanHall Architect ct « / _ : ��� Name-7tle ' ®&na / °% 2 \ o te " :«> \\\ \�w �:d�%� / \ , &+ i }\ `art � � » i C» d J & / �& , Project 9gE R ichen Residence Report date: 03 28/22 Data filename: Page 2 oflo REScheck Software Version : REScheck-Web 1/41 Inspection Checklist Energy Code: 2018 IECC Requirements: 37.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, Construction drawings and ❑Complies Requirement will be met. 103.2 'documentation demonstrate DDoes Not [PR1]1 ,energy code compliance for the Location on plans/spec:A- building envelope.Thermal :Not Observable .1 envelope represented on ❑Not Applicable construction documents. 103.1, 'Construction drawings and ❑Complies 103.2, :documentation demonstrate ❑Does Not 403.7 energy code compliance for ❑Not Observable [PR3]1 ;lighting and mechanical systems. Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is: Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr '❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: Not Observable ; , Manual J or other methods Btu/hr Btu/hr ❑Not Ap plicable by the code official. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Reichen Residence Report date: 03/28/22 Data filename: Page 3 of10 Section Plans Verified Field Verified Y — # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1 Conditioned basement wall R- R- '❑Complies See the Envelope Assemblies [F04]1 insulation R-value.Where interior R_ R- ''❑Does Not table for values. , insulation is used,verification may need to occur during [Not Observable 'Insulation Inspection. Not ONot Applicable required in warm-humid locations in Climate Zone 3. ' 303.2 Conditioned basement wall ❑Complies Requirement will be met. [F05]1 insulation installed per ❑Does Not 'manufacturer's instructions. Location on plans/spec:A- ❑Not Observable 1 ' ONot Applicable 402.2.9 Conditioned basement wall ft ft ;❑Complies ,See the Envelope Assemblies [F06]1 'insulation depth of burial or ;❑Does Not table for values. ,, distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 :A protective covering is installed ❑Complies 'Requirement will be met. [FO11]2 to protect exposed exterior ❑Does Not „; insulation and extends a ,Location on plans/spec:A- minimum of 6 in. below grade. ['Not Observable -7 A-10 ONot Applicable 403.9 Snow-and ice-melting system DComplies (F012)2 controls installed. . DDoes Not •❑Not Observable ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Reichen Residence Report date: 03/28/22 Data filename: Page 4 of10 Section plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U-factor. : U- U- '❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not ;table for values. [FR1]1 ❑Not Observable siJ . ;❑Not Applicable 402.1.1, ;Glazing U-factor(area-weighted ° U- ; U- :DComplies ;See the Envelope Assemblies 402.3.1, i average). ❑Does Not ;table for values. 402.3.3, 402.5 ❑Not Observable [FR2]1 ❑Not Applicable 303.1.3 'U-factors of fenestration products ❑Complies `Requirement will be met. [FR4]1 are determined in accordance ❑Does Not Vy ;with the NFRC test procedure or Location on plans/spec:A- ;taken from the default table. • ❑Not Observable ,1 •❑Not Applicable 402.4.1.1 ;Air barrier and thermal barrier ❑Complies !Requirement will be met. [FR23]1 installed per manufacturer's • ❑Does Not instructions. Location on plans/spec:A- [Not Observable 1 • ❑Not Applicable • 402.4.3 ;Fenestration that is not site built ❑Complies ;Requirement will be met. [FR20]1 !is listed and labeled as meeting ❑Does Not • IAAMA/WDMA/CSA 101/I.S.2/A440 'or has infiltration rates per NFRC ❑Not Observable ;400 that do not exceed code ❑Not Applicable limits. - • 402.4.5 IC-rated recessed lighting fixtures ❑Complies ;Exception: Requirement is [FR16]2 sealed at housing/interior finish ❑Does Not not applicable. and labeled to indicate_<2.0 cfm leakage at 75 Pa. ['Not Observable ; . DNot Applicable 403.3.1 ;Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not €9, !>= 3 inches in diameter and >= R-6 where < 3 inches.Supply and pilot Observable return ducts in other portions of ❑Not Applicable !the building insulated >= R-6 for diameter>=3 inches and R-4.2 ;for< 3 inches in diameter. • • 403.3.2 Ducts, air handlers and filter ❑Complies [FR13]1 ;boxes are sealed with ❑Does Not • ,5i;, !joints/seams compliant with International Mechanical Code or :Not Observable International Residential Code, as ❑Not Applicable ' applicable. 403.3.5 Building cavities are not used as • • ❑Complies [FR15]3 •ducts or plenums. ❑Does Not • ❑Not Observable ❑Not Applicable • • 1 High Impact(Tier 1) '2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Reichen Residence Report date: 03/28/22 Data filename: Page 5 of10 Section Plans Verified Field Verified • # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 403.3.7 Ducts declared to be within the ❑Complies [FR28]3 conditioned space are either 1) ODoes Not }; completely within the continuous ' 'air barrier and within the building ONot Observable thermal envelope,2) buried ❑Not Applicable within ceiling insulation in accordance with Section R403.3.6 and the air handler is located completely within the continuous air barrier and within the building thermal envelope and the duct leakage is <= 1.5 , cfm/100 square feet of conditioned floor area served by the duct system, or 3)the ceiling insulation R-value installed ` against and above the insulated ' duct>=to the proposed ceiling insulation R-value, less the.R- value of the insulation on the 403.4 HVAC piping conveying fluids ` R- ' R- ;DComplies [FR17]2 'above 105°F or chilled fluids ❑Does Not ' . below 55°F are insulated to__.R- g ;DNot Observable ❑Not Applicable 403.4.1 'Protection of insulation on HVAC ,❑Complies [FR24]1 piping. ❑Does Not `-'' ❑Not Observable ❑Not Applicable 403.5.3 'Hot water pipes are insulated to ' R- ; R- ;❑Complies [FR18]2" zR-3. ❑Does Not :?: ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are DComplies Requirement will be met. [FR19]2 installed on all outdoor air EDoes Not intakes and exhausts. [Not Observable 'Location on plans/spec:A- 1❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Reichen Residence Report date: 03/28/22 Data filename: Page 6 of10 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions 61 Req.ID 303.1 All installed insulation is labeled DComplies Requirement will be met. [IN13]2 or the installed R-values ODoes Not provided. ONot Observable ; ONot Applicable 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies 'See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.E wall insulation on the wall ❑ Mass 0 Mass ONot Observable [IN3]1 ;exterior,the exterior insulation requirement applies (FR10). ❑ Steel ❑ Steel ONot Applicable • 303.2 'Wall insulation is installed per ❑Complies 'Requirement will be met. [IN4]1 manufacturers instructions. DDoes Not ONot Observable Location on plans/spec:A- , ONot Applicable ;1 Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Reichen Residence Report date: 03/28/22 Data filename: Page 7 of10 Section _ J Plans Verified Field Verified y # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- R- ,DComplies 'See the Envelope Assemblies 402.2.1, ' 0 Wood 0 Wood ❑Does Not table for values. 402.2.2,402.2.E ❑ Steel :❑ Steel ❑Not Observable [FI1]1 ,❑Not Applicable 303.1.1.1, 'Ceiling insulation installed per DComplies Requirement will be met. 303.2 manufacturer's instructions. Does Not [FI2]1 Blown insulation marked every Location on plans/spec:A- 300 ft2. ❑Not Observable :1 ❑Not Applicable 402.2.3 Vented attics with air permeable DComplies ;Requirement will be met. [FI22]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that Location on plans/spec:A- extends over insulation. ❑Not Observable :1 ' ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies Requirement will be met. [FI3]1 insulation >R-value of the DDoes Not adjacent assembly. Location on plans/spec:A- ❑Not Observable 1 DNot Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 : ACH 50= ACH 50= DComplies Requirement will be met. [FI1731 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. Location on plans/spec:A- ❑Not Observable 1 ❑Not Applicable 403.3.3 :Ducts are pressure tested to cfm/100 cfm/100 '❑Complies [FI27]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total :leakage measured with a ;❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g.across the system including ;the manufacturer's air handler enclosure if installed at time of :test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.4 :Duct tightness test result of<=4 . cfm/100 cfm/100 '❑Complies [FI4]1 ;cfm/100 ft2 across the system or : ft2 ft2 ;❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ;❑Not Observable tests, verification may need to !❑Not Applicable occur during Framing Inspection. 403.3.2.1 ;Air handler leakage designated .❑Complies^ [FI24]1 ,by manufacturer at<=2%of ❑Does Not design airflow. ENot Observable ❑Not Applicable 403.1.1 Programmable thermostats DComplies [FI9]2 ,installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to 'ONot Observable code specifications. ❑Not Applicable 403.1,2 Heat pump thermostat installed DComplies [FI10)2 on heat pumps. ❑Does Not ' ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water DComplies [FI11]2. . systems have automatic or ❑Does Not accessible manual controls. [Not Observable ❑Not Applicable 1 J High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Reichen Residence Report date: 03/28/22 Data filename: Page 8 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.6.1 All mechanical ventilation system DComplies [F125]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy Not Observable and airflow limits per Table ❑ R403.6.1, ❑Not Applicable. 403.2 Hot water boilers supplying heat DComplies [FI26]2 through one-or two-pipe heating, ❑Does Not systems have outdoor setback control to lower boiler water ENot Observable temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 ;Heated water circulation systems DComplies [F128)2 have a circulation pump.The ❑Does Not ;system return pipe is a dedicated [Not Observable return pipe or a cold water supply pipe.Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 :Electric heat trace systems DComplies [FI29]2 comply with IEEE 515.1 or UL ❑Does Not 515.Controls automatically adjust the energy input to the ['Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Demand recirculation water DComplies [F130]2 `systems have controls that ❑Does Not manage operation of the pump and limit the temperature of the ❑Not Observable water entering the cold water ENot Applicable piping to <= 104°F. 403.5.4 Drain water heat recovery units . DComplies [F131]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units<3 psi for ENot Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 ;90%or more of permanent DComplies [F16]1 fixtures have high efficacy lamps. ❑Does Not [Not Observable ENot Applicable 404.1.1 Fuel gas lighting systems have DComplies [F123]3 .no continuous pilot light. ❑Does Not ENot Observable ENot Applicable 401.3 Compliance certificate posted. DComplies Requirement will be met. [F17]2 ❑Does Not ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Reichen Residence Report date: 03/28/22 Data filename: Page 9 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 303.3 Manufacturer manuals for OComplies [FI1813 mechanical and water heating ,ODoes Not systems have been provided. ❑Not Observable ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Reichen Residence Report date: 03/28/22 Data filename: Page 10 of10 • 2 2018 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 28.00 Below-Grade Wall 28.00 Floor 0.00 Ceiling/ Roof 49.00 Ductwork(unconditioned spaces): Glass & Door Rating U-Factor SHGC Window 0.29 Door 0.32 Heating & Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments F. W. WEBB COMPANY RESIDENTIAL HEAT LOSS/GAIN CALCULATIONS PREPARED BY SLL PROJECT # : 236607 BY SLL ENTERED 05/25/22 BLDG 1 . NAME :MCQUEEN GAIN BTU: 46932 2 . LOCATION :REICHEN GAIN CMF: 1566 3 . HI DESIGN TMP: 91 8 .GRND TEMP 50 LOSS BTU: 100652 4 . LO DESIGN TMP: -20 9 . COOL AIR TMP: 50 LOSS CFM: 1902 5 . ROOM TEMP 71 10 .WARM AIR TMP: 120 BASEBRD' : 180 6 . LEEWAY 10 TONNAGE : 3 . 9 7 . # OF PEOPLE 5@400 E ©SO W_El ROOM # 1 OF 14 41 .WALL G DELTA 20 12 .ROOM NAME :FAMILY JUN 09 2022 42 .WALL L DELTA : 91 43 . FLOOR G DELTA : 0 TOWN OF QUEENSBURY 44 . FLOOR L DELTA : 91 BUILDING & CODES 45 . CEILNG G DLTA 0 46 .CEILNG L DLTA : 0 47 .BELW GRD DLTA : 21 35 .MISC BTU GAIN : 13 .EXT WALL LEN : 173 24 .FLOOR R-FACTOR: 19 36 .MISC BTU LOSS : 14 .EXT WALL HGT : 8 25 .HEAT/CL BELOW : SLAB 37 .BASEBD BTU/FT : 580 15 .WALL R-FCTR 19 26 .CEILING R-FCTR: 19 38 . PEOPLE BTUS 400 16 .WINDOW SQ FT : 75 27 .HEAT/CL ABOVE? : Y 39 .MOIS TURE 23 17 .WINDOW GLASS : D 28 .SKY LGHT SQ FT: 0 40 . ZONE 1 18 .DOOR SQ FT 21 29 .SKY LGHT TYPE : D ***TOTALS FOR ROOM***ZONE 19 .DOOR R-FCTR 2 30 .AIR CHGS/HOUR' : . 50 * GAIN BTU: 10754 44932 20 .N,NE,E, SE. . . : S 31 .EXTRA PEOPLE * GAIN CFM: 358 1499 21 .WIN. SHADING : N 32 .LIGHTS (WATTS) : * LOSS BTU: 33249 100652 22 . 96 BELOW GRADE: 50 33 .KITCHEN(Y/N) N * LOSS CFM: 628 1902 23 .FLOOR SQ FT 1626 34 .BATH(Y*N) N * BASEBRD' : 58 180 ROOM # 2 OF 14 41 .WALL G DELTA 20 12 .ROOM NAME :BED 1 42 .WALL L DELTA 91 43 . FLOOR G DELTA : 0 44 . FLOOR L DELTA : 0 45 . CEILNG G DLTA : 20 46 . CEILNG L DLTA : 91 47 .BELW GRD DLTA : 21 35 .MISC BTU GAIN : 13 .EXT WALL LEN : 32 24 .FLOOR R-FACTOR: 19 36 .MISC BTU LOSS : 14 .EXT WALL HGT : 10 25 .HEAT/CL BELOW : Y 37 .BASEBD BTU/FT : 580 15 .WALL R-FCTR 19 26 . CEILING R-FCTR: 38 38 . PEOPLE BTUS 400 16 .WINDOW SQ FT : 30 27 .HEAT/CL ABOVE? : N 39 .MOIS TURE 23 17 .WINDOW GLASS : D 28 .SKY LGHT SQ FT: 0 40 . ZONE 1 18 .DOOR SQ FT 0 29 .SKY LGHT TYPE : D ***TOTALS FOR ROOM***ZONE 19 .DOOR R-FCTR 2 30 .AIR CHGS/HOUR : . 50 * GAIN BTU: 2960 44932 20 .N,NE,E, SE. . . : S 31 .EXTRA PEOPLE * GAIN CFM: 99 1499 21.WIN. SHADING : N 32 .LIGHTS (WATTS) : * LOSS BTU: 4748 100652 22 . 9i6 BELOW GRADE: 0 33 .KITCHEN(Y/N) N * LOSS CFM: 90 1902 23 . FLOOR SQ FT 127 34 .BATH(Y*N) N * BASEBRD' : 9 180 . RC-0360-2022 308.9-1-11 Reichen, ]essalie & Mark 14 Twin Mountain Dr SFD w/gas fp 2555 s.f., Garage 938 s.f. c • ROOM # 3 OF 14 41 .WALL G DELTA 20 12 .ROOM NAME :FOYER 42 .WALL L DELTA 91 43 . FLOOR G DELTA : 0 44 . FLOOR L DELTA : 0 45 . CEILNG G DLTA : 20 46 . CEILNG L DLTA : 91 47 .BELW GRD DLTA : 21 35 .MISC BTU GAIN : 13 .EXT WALL LEN : 25 24 . FLOOR R-FACTOR: 19 36 .MISC BTU LOSS : 14 .EXT WALL HGT : 10 25 .HEAT/CL BELOW : Y 37 .BASEBD BTU/FT : 580 15 .WALL R-FCTR 19 26 . CEILING R-FCTR: 38 38 . PEOPLE BTUS 400 16 .WINDOW SQ FT : 0 27 .HEAT/CL ABOVE? : N 39 .MOIS TURE 23 17 .WINDOW GLASS : D 28 .SKY LGHT SQ FT: 0 40 . ZONE 1 18 .DOOR SQ FT 42 29 .SKY LGHT TYPE : D ***TOTALS FOR ROOM***ZONE 19 .DOOR R-FCTR 2 30 .AIR CHGS/HOUR : . 50 * GAIN BTU: 1635 44932 20 .N,NE, E, SE. . . : S 31 .EXTRA PEOPLE * GAIN CFM: 55 1499 21.WIN. SHADING : N 32 .LIGHTS (WATTS) : * LOSS BTU: 5888 100652 22 . 96 BELOW GRADE: 0 33 .KITCHEN(Y/N) N * LOSS CFM: 111 1902 23 . FLOOR SQ FT 231 34 .BATH (Y*N) N * BASEBRD' : 11 180 ROOM # 4 OF 14 41.WALL G DELTA 20 12 .ROOM NAME : PWDR 42 .WALL L DELTA 91 43 . FLOOR G DELTA : 20 44 .FLOOR L DELTA : 91 45 . CEILNG G DLTA : 20 46 . CEILNG L DLTA : 91 47 .BELW GRD DLTA : 21 35 .MISC BTU GAIN : 13 .EXT WALL LEN : 5 24 . FLOOR R-FACTOR: 19 36 .MISC BTU LOSS : 14 .EXT WALL HGT : 8 25 .HEAT/CL BELOW : N 37 .BASEBD BTU/FT : 580 15 .WALL R-FCTR 19 26 . CEILING R-FCTR: 38 38 . PEOPLE BTUS 400 16 .WINDOW SQ FT : 0 27 .HEAT/CL ABOVE? : N 39 .MOIS TURE 23 17 .WINDOW GLASS : D 28 .SKY LGHT SQ FT: 0 40 . ZONE 1 18 .DOOR SQ FT 0 29 .SKY LGHT TYPE : D ***TOTALS FOR ROOM***ZONE 19 .DOOR R-FCTR 2 30 .AIR CHGS/HOUR : . 50 * GAIN BTU: 204 44932 20 .N,NE, E, SE. . . : S 31 .EXTRA PEOPLE * GAIN CFM: 7 1499 21 .WIN. SHADING : N 32 .LIGHTS (WATTS) : * LOSS BTU: 740 100652 22 . 96 BELOW GRADE: 0 33 .KITCHEN(Y/N) N * LOSS CFM: 14 1902 23 . FLOOR SQ FT 35 34 .BATH (Y*N) N * BASEBRD' : 2 180 ROOM # 5 OF 14 41 .WALL G DELTA 20 12 .ROOM NAME : PANTRY 42 .WALL L DELTA 91 43 .FLOOR G DELTA : 20 44 . FLOOR L DELTA : 91 45 . CEILNG G DLTA : 20 46 . CEILNG L DLTA : 91 47 .BELW GRD DLTA : 21 35 .MISC BTU GAIN : 13 .EXT WALL LEN : 5 24 .FLOOR R-FACTOR: 19 36 .MISC BTU LOSS : 14 .EXT WALL HGT : 8 25 .HEAT/CL BELOW : N 37 .BASEBD BTU/FT : 580 15 .WALL R-FCTR 19 26 . CEILING R-FCTR: 38 38 .PEOPLE BTUS 400 16 .WINDOW SQ FT : 0 27 .HEAT/CL ABOVE? : N 39 .MOIS TURE 23 17 .WINDOW GLASS : D 28 .SKY LGHT SQ FT: 0 40 . ZONE 1 18 .DOOR SQ FT 0 29 .SKY LGHT TYPE : D ***TOTALS FOR ROOM***ZONE 19 .DOOR R-FCTR 2 30 .AIR CHGS/HOUR : . 50 * GAIN BTU: 204 44932 20 .N,NE,E, SE. . . : S 31.EXTRA PEOPLE * GAIN CFM: 7 1499 21 .WIN. SHADING : N 32 .LIGHTS (WATTS) : * LOSS BTU: 740 100652 22 . 96 BELOW GRADE: 0 33 .KITCHEN(Y/N) N * LOSS CFM: 14 1902 23 .FLOOR SQ FT 35 34 .BATH (Y*N) N * BASEBRD' : 2 180 ROOM # 6 OF 14 41 .WALL G DELTA 20 12 .ROOM NAME :MUD 42 .WALL L DELTA 91 43 . FLOOR G DELTA : 20 44 . FLOOR L DELTA : 91 45 . CEILNG G DLTA : 20 46 . CEILNG L DLTA : 91 47 .BELW GRD DLTA : 21 35 .MISC BTU GAIN : 13 .EXT WALL LEN : 25 24 . FLOOR R-FACTOR: 19 36 .MISC BTU LOSS : 14 .EXT WALL HGT : 10 25 .HEAT/CL BELOW : N 37 .BASEBD BTU/FT : 580 15 .WALL R-FCTR 19 26 .CEILING R-FCTR: 38 38 . PEOPLE BTUS 400 16 .WINDOW SQ FT : 12 27 .HEAT/CL ABOVE? : N 39 .MOIS TURE 23 17 .WINDOW GLASS : D 28 .SKY LGHT SQ FT: 0 40 . ZONE 1 18 .DOOR SQ FT 21 29 .SKY LGHT TYPE : D ***TOTALS FOR ROOM***ZONE 19 .DOOR R-FCTR 2 30 .AIR CHGS/HOUR : . 50 * GAIN BTU: 1982 44932 20 .N,NE, E, SE. . . : S 31 .EXTRA PEOPLE * GAIN CFM: 66 1499 21.WIN. SHADING : N 32 .LIGHTS (WATTS) : * LOSS BTU: 5022 100652 22 . 96 BELOW GRADE: 0 33 .KITCHEN(Y/N) N * LOSS CFM: 95 1902 23 .FLOOR SQ FT 126 34 .BATH(Y*N) N * BASEBRD' : 9 180 ROOM # 7 OF 14 41 .WALL G DELTA 20 12 .ROOM NAME :KITCHEN 42 .WALL L DELTA 91 43 . FLOOR G DELTA : 20 44 . FLOOR L DELTA : 91 45 . CEILNG G DLTA : 20 46 .CEILNG L DLTA : 91 47 .BELW GRD DLTA : 21 35 .MISC BTU GAIN : 13 .EXT WALL LEN : 16 24 . FLOOR R-FACTOR: 19 36 .MISC BTU LOSS : 14 .EXT WALL HGT : 10 25 .HEAT/CL BELOW : N 37 .BASEBD BTU/FT : 580 15 .WALL R-FCTR 19 26 . CEILING R-FCTR: 38 38 . PEOPLE BTUS 400 16 .WINDOW SQ FT : 0 27 .HEAT/CL ABOVE? : N 39 .MOIS TURE 23 17 .WINDOW GLASS : D 28 .SKY LGHT SQ FT: 0 40 . ZONE 1 18 .DOOR SQ FT 0 29 .SKY. LGHT TYPE : D ***TOTALS FOR ROOM***ZONE 19 .DOOR R-FCTR 2 30 .AIR CHGS/HOUR : . 50 * GAIN BTU: 3165 44932 20 .N,NE,E, SE. . . : S 31 .EXTRA PEOPLE * GAIN CFM: 105 1499 21 .WIN. SHADING : N 32 .LIGHTS (WATTS) : * LOSS BTU: 5172 100652 22 . o BELOW GRADE: 0 33 .KITCHEN(Y/N) Y * LOSS CFM: 98 1902 23 . FLOOR SQ FT 256 34 .BATH(Y*N) N * BASEBRD' : 9 180 ROOM # 8 OF 14 41 .WALL G DELTA 20 12 .ROOM NAME :DINING 42 .WALL L DELTA 91 43 . FLOOR G DELTA : 20 44 .FLOOR L DELTA : 91 45 .CEILNG G DLTA : 20 46 .CEILNG L DLTA : 91 47 .BELW GRD DLTA : 21 35 .MISC BTU GAIN : 13 .EXT WALL LEN : 34 24 . FLOOR R-FACTOR: 19 36 .MISC BTU LOSS : 14 .EXT WALL HGT : 10 25 .HEAT/CL BELOW : N 37 .BASEBD BTU/FT : 580 15 .WALL R-FCTR 19 26 .CEILING R-FCTR: 38 38 . PEOPLE BTUS 400 16 .WINDOW SQ FT : 85 27 .HEAT/CL ABOVE? : N 39 .MOIS TURE 23 17 .WINDOW GLASS : D 28 . SKY LGHT SQ FT: 0 40 . ZONE 1 18 .DOOR SQ FT 0 29 .SKY LGHT TYPE : D ***TOTALS FOR ROOM***ZONE 19 .DOOR R-FCTR 2 30 .AIR CHGS/HOUR : . 50 * GAIN BTU: 7318 44932 20 .N,NE,E, SE. . . : S 31.EXTRA PEOPLE * GAIN CFM: 244 1499 21 .WIN. SHADING : N 32 .LIGHTS (WATTS) : * LOSS BTU: 9661 100652 22 . % BELOW GRADE: 0 33 .KITCHEN(Y/N) N * LOSS CFM: 183 1902 23 . FLOOR SQ FT 200 34 .BATH (Y*N) N * BASEBRD' : 17 180 ROOM # 9 OF 14 41 .WALL G DELTA 20 12 .ROOM NAME :GREAT 42 .WALL L DELTA 91 43 .FLOOR G DELTA : 0 44 .FLOOR L DELTA : 0 45 . CEILNG G DLTA : 20 46 . CEILNG L DLTA : 91 47 .BELW GRD DLTA : 21 35 .MISC BTU GAIN : 13 .EXT WALL LEN : 24 24 . FLOOR R-FACTOR: 19 36 .MISC BTU LOSS : 14 .EXT WALL HGT : 16 25 .HEAT/CL BELOW : Y 37 .BASEBD BTU/FT : 580 15 .WALL R-FCTR 19 26 . CEILING R-FCTR: 38 38 . PEOPLE BTUS 400 16 .WINDOW SQ FT : 0 27 .HEAT/CL ABOVE? : N 39 .MOIS TURE 23 17 .WINDOW GLASS : D 28 .SKY LGHT SQ FT: 0 40 . ZONE 1 18 .DOOR SQ FT 105 29 .SKY LGHT TYPE : D ***TOTALS FOR ROOM***ZONE 19 .DOOR R-FCTR 2 30 .AIR CHGS/HOUR : . 50 * GAIN BTU: 4998 44932 20 .N,NE, E, SE. . . : S 31 .EXTRA PEOPLE * GAIN CFM: 167 1499 21.WIN. SHADING : N 32 .LIGHTS (WATTS) : * LOSS BTU: 16545 100652 22 . 96 BELOW GRADE: 0 33 .KITCHEN(Y/N) N * LOSS CFM: 313 1902 23 .FLOOR SQ FT 576 34 .BATH (Y*N) N * BASEBRD' : 29 180 ROOM # 10 OF 14 41.WALL G DELTA 20 12 .ROOM NAME :WIC 42 .WALL L DELTA 91 43 .FLOOR G DELTA : 0 44 . FLOOR L DELTA : 0 45 . CEILNG G DLTA : 20 46 . CEILNG L DLTA : 91 47 .BELW GRD DLTA : 21 35 .MISC BTU GAIN : 13 .EXT WALL LEN : 31 24 . FLOOR R-FACTOR: 19 36 .MISC BTU LOSS : 14 .EXT WALL HGT : 10 25 .HEAT/CL BELOW : Y 37 .BASEBD BTU/FT : 580 15 .WALL R-FCTR 19 26 . CEILING R-FCTR: 38 38 . PEOPLE BTUS 400 16 .WINDOW SQ FT : 0 27 .HEAT/CL ABOVE? : N 39 .MOIS TURE 23 17 .WINDOW GLASS : D 28 .SKY LGHT SQ FT: 0 40 . ZONE 1 18 .DOOR SQ FT 0 29 .SKY LGHT TYPE : D ***TOTALS FOR ROOM***ZONE 19 .DOOR R-FCTR 2 30 .AIR CHGS/HOUR : . 50 * GAIN BTU: 783 44932 20 .N,NE,E, SE. . . : S 31 .EXTRA PEOPLE * GAIN CFM: 26 1499 21.WIN. SHADING : N 32 .LIGHTS (WATTS) : * LOSS BTU: 2856 100652 22 . 96 BELOW GRADE: 0 33 .KITCHEN(Y/N) N * LOSS CFM: 54 1902 23 . FLOOR SQ FT 105 34 .BATH (Y*N) N * BASEBRD' : 5 180 ROOM # 11 OF 14 41.WALL G DELTA 20 12 .ROOM NAME :MASTER 42 .WALL L DELTA 91 43 . FLOOR G DELTA : 0 44 . FLOOR .L DELTA : 0 45 . CEILNG G DLTA : 20 46 .CEILNG L DLTA : 91 47 .BELW GRD DLTA : 21 35 .MISC BTU GAIN : 13 .EXT WALL LEN : 14 24 . FLOOR R-FACTOR: 19 36 .MISC BTU LOSS : 14 .EXT WALL HGT : 10 25 .HEAT/CL BELOW : Y 37 .BASEBD BTU/FT : 580 15 .WALL R-FCTR 19 26 .CEILING R-FCTR: 38 38 . PEOPLE BTUS 400 16 .WINDOW SQ FT : 55 27 .HEAT/CL ABOVE? : N 39 .MOIS TURE 23 17 .WINDOW GLASS : D 28 .SKY LGHT SQ FT: 0 40 . ZONE 1 18 .DOOR SQ FT 0 29 .SKY LGHT TYPE : D ***TOTALS FOR ROOM***ZONE 19 .DOOR R-FCTR 2 30 .AIR CHGS/HOUR : . 50 * GAIN BTU: 4947 44932 20 .N,NE, E, SE. . . : S 31 .EXTRA PEOPLE * GAIN CFM: 165 1499 21.WIN. SHADING : N 32 .LIGHTS (WATTS) : * LOSS BTU: 6459 100652 22 . 96 BELOW GRADE: 0 33 .KITCHEN(Y/N) N * LOSS CFM: 122 1902 23 .FLOOR SQ FT 242 34 .BATH (Y*N) N * BASEBRD' : 12 180 ROOM # 12 OF 14 41 .WALL G DELTA 20 12 .ROOM NAME :BATH MASTER 42 .WALL L DELTA 91 43 . FLOOR G DELTA : 0 44 . FLOOR L DELTA : 0 45 . CEILNG G DLTA : 20 46 .CEILNG L DLTA : 91 47 .BELW GRD DLTA : 21 35 .MISC BTU GAIN : 13 .EXT WALL LEN : 13 24 . FLOOR R-FACTOR: 19 36 .MISC BTU LOSS : 14 .EXT WALL HGT : 9 25 .HEAT/CL BELOW : Y 37 .BASEBD BTU/FT : 580 15 .WALL R-FCTR 19 26 . CEILING R-FCTR: 38 38 . PEOPLE BTUS 400 16 .WINDOW SQ FT : 21 27 .HEAT/CL ABOVE? : N 39 .MOIS TURE 23 17 .WINDOW GLASS : D 28 .SKY LGHT SQ FT: 0 40 . ZONE 1 18 .DOOR SQ FT 0 29 .SKY LGHT TYPE : D ***TOTALS FOR ROOM***ZONE 19 .DOOR R-FCTR 2 30 .AIR CHGS/HOUR : . 50 * GAIN BTU: 2125 44932 20 .N,NE, E, SE. . . : S 31.EXTRA PEOPLE * GAIN CFM: 71 1499 21.WIN. SHADING : ,N 32 .LIGHTS (WATTS) : * LOSS BTU: 3939 100652 22 . 96 BELOW GRADE: 0 33 .KITCHEN(Y/N) N * LOSS CFM: 74 1902 23 .FLOOR SQ FT 145 34 .BATH (Y*N) Y * BASEBRD' : 7 180 ROOM # 13 OF 14 41 .WALL G DELTA 20 12 .ROOM NAME :BED 2 42 .WALL L DELTA 91 43 . FLOOR G DELTA : 0 44 . FLOOR L DELTA : 0 45 . CEILNG G DLTA : 20 46 .CEILNG L DLTA : 91 47 .BELW GRD DLTA : 21 35 .MISC BTU GAIN : 13 .EXT WALL LEN : 8 24 . FLOOR R-FACTOR: 19 36 .MISC BTU LOSS : 14 .EXT WALL HGT : 9 25 .HEAT/CL BELOW .: Y 37 .BASEBD BTU/FT : 580 15 .WALL R-FCTR 19 26 .CEILING R-FCTR: 38 38 . PEOPLE BTUS 400 16 .WINDOW SQ FT : 30 27 .HEAT/CL ABOVE? : N 39 .MOIS TURE 23 17 .WINDOW GLASS : D 28 .SKY LGHT SQ FT: 0 40 . ZONE 1 18 .DOOR SQ FT 0 29 .SKY LGHT TYPE : D ***TOTALS FOR ROOM***ZONE 19 .DOOR R-FCTR 2 30 .AIR CHGS/HOUR : . 50 * GAIN BTU: 2670 44932 20 .N,NE, E, SE. . . : S 31.EXTRA PEOPLE * GAIN CFM: 89 1499 21.WIN. SHADING : N 32 .LIGHTS (WATTS) : * LOSS BTU: 3445 100652 22 . 96 BELOW GRADE: 0 33 .KITCHEN(Y/N) N * LOSS CFM: 65 1902 23 .FLOOR SQ FT 138 34 .BATH (Y*N) N * BASEBRD' : 6 180 ROOM ## 14 OF 14 41 .WALL G DELTA 20 12 .ROOM NAME :BATH 42 .WALL L DELTA 91 43 . FLOOR G DELTA : 0 44 . FLOOR L DELTA : 0 45 .CEILNG G DLTA : 20 46 . CEILNG L DLTA : 91 47 .BELW GRD DLTA : 21 35 .MISC BTU GAIN : 13 .EXT WALL LEN : 9 24 .FLOOR R-FACTOR: 19 36 .MISC BTU LOSS : 14 .EXT WALL HGT : 9 25 .HEAT/CL BELOW : Y 37 .BASEBD BTU/FT : 580 15 .WALL R-FCTR 19 26 .CEILING R-FCTR: 38 38 . PEOPLE BTUS 400 16 .WINDOW SQ FT : 12 27 .HEAT/CL ABOVE? : N 39 .MOIS TURE 23 17 .WINDOW GLASS : D 28 . SKY LGHT SQ FT: 0 40 . ZONE 1 18 .DOOR SQ FT 0 29 . SKY LGHT TYPE : D ***TOTALS FOR ROOM***ZONE 19 .DOOR R-FCTR 2 30 .AIR CHGS/HOUR : . 50 * GAIN BTU: 1187 44932 20 .N,NE,E, SE. . . : S 31 .EXTRA PEOPLE * GAIN CFM: 40 1499 21.WIN. SHADING : N 32 .LIGHTS (WATTS) : * LOSS BTU: 2188 100652 22 . 96 BELOW GRADE: 0 33 .KITCHEN(Y/N) N * LOSS CFM: 41 1902 23 .FLOOR SQ FT 71 34 .BATH (Y*N) Y * BASEBRD' : 4 180 Manual S Compliance Report Job: REICHEN Date: May 25,2022 Entire House By: Plan: REICHEN Project Information For: richard mcqueen, RICHARD MCQUEEN FINE HOMEBUILDING FORTANN, ny Cooling Equipment Design Conditions Outdoor design DB: 85.0°F Sensible gain: 31418 Btuh Entering coil DB: 75.3°F Outdoor design WB: 71.0°F Latent gain: 7228 Btuh Entering coil WB: 62.6°F Indoor design DB: 75.0°F Total gain: 38646 Btuh Indoor RH: 50% Estimated airflow: 1503 cfm • Manufacturer's Performance Data at Actual Design Conditions U �' Equipment type: Split AC JUN 0 9 Manufacturer: York Model: YCJD48S41S1+AX481CT 2022 Actual airflow: 1567 cfm TOWS Sensible capacity: 0 Btuh 0% of load BUILDING QUEENSB Latent capacity: . 0 Btuh 0% of load & CODESRY Total capacity: 0 Btuh 0% of load SHR: 0% Heating Equipment Design Conditions Outdoor design DB: -4.0°F Heat loss: 143655 Btuh Entering coil DB: 65.3°F Indoor design DB: 68.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: York - Model: TM9X120D2OMP11 Actual airflow: 1567 cfm Output capacity: 114000 Btuh 79% of load Temp. rise: 50 °F Meets are all requirements of ACCA Manual S. • ® 2022-May-25 09:40:40 wrightsoft Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 ACCk ...rs\scott.langeworthy\Documents\York\REICHEN.rup Calc=MJ7 Front Door faces: N r . Residential Plans Examiner Review Form Form RPER 1 ACCP. for HVAC System Design (Loads, Equipment, Ducts) 15Mar09 Ai Ccnitang CatradasdMwwlra QUEENSBURY NY • Header Information Contractor: REQUIRED ATTACHMENTS ATTACHED Manual J1 Form(and supporting worksheets): Yes ❑ No ❑ Mechanical license: or MJ1AE Form*(and supporting worksheets): Yes ❑ No 0 OEM performance data(heating,cooling,blower): Yes ❑ No ❑ Building plan#: REICHEN Manual D Friction Rate Worksheet: Yes ❑ No Duct distribution sketch: Yes 0 No ❑ Home address(Street or Lot#,Block,Subdivision): , Entire House HVAC LOAD CALCULATION (IRC M1401.3) Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature: -4 °F Orientation: Front Door faces North Indoor temperature: 68 °F North,East,West,South,Northeast,Northwest,Southeast,Southwest Total heat loss: 143655 Btuh Number of bedrooms: 3 Conditioned floor area: 7384 ft2 Summer Design Conditions Number of occupants: 0 Outdoor temperature: 85 °F Indoor temperature: - 75 °F Windows Roof Grains difference: 27 grub a1 0% RH Eave overhang depth: 0 ft Sensible heat gain: 34909 Btuh Internal shade: none Eave Latent heatgain: Blinds,drapes,etc. 8031 Btuh Depth Window Total heat gain: 42940 Btuh Number of skylights: 0 HVAC EQUIPMENT SELECTION (IRC M1401.3) Heating Equipment Data Cooling Equipment Data Blower Data Equipment ty e: Gas furnace Equipment type: Split AC Heating cfm: 1567 umace,Hea pump,Boiler,etc. lr onditioner,Heat pump,etc. Cooling cfm: 1567 Model: York Model: York Static pressure: 0 in H2O TM9X120D2OMP11 YCJ D48S41 S1+AX481 CT Fan's rated extemal static pressure for design airflow Heating output capacity:. 114000 Btuh Total cooling capacity: 0 Btuh Heat pumps-capacity at winter design outdoor conditions Sensible cooling capacity: 0 Btuh Aux.heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1) Design airflow: 1567 cfm Longest supply duct: 0 ft Duct Materials Used Equipment design ESP: 0 in H2O Longest return duct: 0 ft Trunk duct: Total device pressure losses: 0 in H2O Total effective length(TEL): 0 ft Available static pressure(ASP): 0 in H2O Friction rate: 0 in/100ft Branch duct: Sheet metal Friction Rate=ASP_(TELx 100) I declare the load calculation,equipment,equipment selection and duct design were rigorously performed based on the building plan listed above. I understand the claims made on these forms will be subject to review and verification. Contractor's printed name: Contractor's signature: Date: Reserved for County,Town Municipality orAuthority having jurisdiction use. *Home qualifies for MJ1AE Form based on Abridged Edition Checklist PI+ wrightsoft® Right-Suite®Universal 2017 17.0.16 RSU25116 Pro ect Summa Job: REICHEN .� � Date: May 25,2022 Entire House By: Plan: REICHEN Pro'ect Information For: richard mcqueen, RICHARD MCQUEEN FINE HOMEBUILDING FORTANN, ny . Notes: Desi• n Information Weather: Glens Falls AP, NY, US Winter Design Conditions Summer Design Conditions Outside db -4 °F Outside db 85 °F Inside db 68 °F Inside db 75 °F Design TD 72 °F Design TD 10 °F Daily range M Relative humidity 50 % Moisture difference 27 gr./lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 135523 Btuh Structure 29922 Btuh Ducts 8131 Btuh Ducts 1496 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Bl (none) 0 Btuh Piping 0 Btuh Equipment load 143655 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 28277 Btuh Method • Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 7228 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 7384 7384 Equipment latent load 7228 Btuh Volume(ft') 59072 . 59072 Air changes/hour 0.90 0.40 Equipment total load 35504 Btuh Equiv.AVF (cfm) 886 394 Req. total capacity at 0.70 SHR 3.4 ton Heating Equipment Summary Cooling Equipment Summary Make York Make York Trade YORK Trade ADP Model TM9X120D2OMP11 Cond YCJD48S41S1 AHRI ref 2008696 Coil AX481CT AHRI ref 7072441 Efficiency 95.5 AFUE Efficiency 12.0 EER, 14 SEER Heating input 120000 Btuh . Sensible cooling 32900 Btuh Heating output 114000 Btuh Latent cooling 14100 Btuh Temperature rise 66 °F Total cooling 47000 Btuh Actual air flow 1567 cfm Actual air flow 1567 cfm Air flow factor 0.011 cfm/Btuh Air flow factor 0.050 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat - Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. 2022-May-25 09:40:40 wrightsoft Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 ...rs\scott.langeworthy\Documents\York\REICHEN.rup Calc=MJ7 Front Door faces: N Right-J®Worksheet Job: REICHEN Entire House Date: May 25,2022 By: Plan: REICHEN MANUAL J:7th Ed. 1 Name of room Entire House Room1 Room2 Room3 2 Length of exposed wall 778.0 ft 248.0 ft 87.0 ft 8.0 ft 3 Room dimensions 1.0 x 2768 ft 1.0 x 684.0 ft 14.0 x 4.0 ft 4 Ceilings Condit.Option 8.0 ft d 8.0 ft heat/cool 8.0 ft heat/cool 8.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg 5 Gross a 12E3 5.4 1.0 6224 **** **** 1984 **** **** 696 **** 64 **** **** Exposed b 0 0 !!!!!l **** **** Ill!!! **** **** [hill ***• **** 1II11! **** **** walls and c 0 0 !lull **** **** !fill! **** **** llllll **** **** flit!! **** **** partitions d 0 0 1l111! **** **** ill!!! **** **** ll Ili l **** **** llllll **** **** e 0 0 !mil **** *** III!!! **** **** llllll **** **** will **** **** f 0 0 hill! **** **** !!!!!! **** **** !!!!!1 **** **** !III!! **** **** 6 Windows and a 3A0 39.7 ** 375 14877 **** 75 2975 **** 30 1190 **** 0 0 **** glass doors b 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** Heating c 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** d 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** f 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** 7 Windows and North 19.0 85 **** 1615 0 **** 0 30 **** 570 0 **** 0 glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Cooling E/W 68.0 85 **** 5780 0 **** 0 0 **** 0 0 **** 0 SE/SW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 South 34.0 205 **** 6970 75 **** 2550 0 **** 0 0 **** 0 Horz 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 8 Other doors a 11 F0 12.2 2.3 168 2056 388 0 0 0 0 0 0 0 0 0 b 0 0 0 0 0 0 0 0 0 -0 0 0 0 0 C 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 5681 30677 5795 1909 10309 1947 666 3596 679 64 346 65 exposed b 0 0 !!!1!! 0 0 111111 0 0 nml 0 0 111111 0 0 walls and c 0 0 lull! 0 0 I!!!!! 0 0 I!!!!! 0 0 11111! 0 0 partitions d 0 0 lull! 0 0 till!! 0 0 I!!1!! 0 0 llllll 0 0 e 0 0 lull! 0 0 I!!!!! 0 0 11111! 0 0 II!!!! 0 0 f 0 0 llllll 0 0 llllll 0 0 lull! 0 0 lull! 0 0 10 Ceilings a 16G0 2.4 1.1 4494 10678 5042 482 1145 541 136 323 153 0 0 0 b 0 0 I!!!!! 0 0 111111 0 0 llllll 0 0 llllll 0 0 O 0 0 !!!!!! 0 0 II!!!! 0 0 !!!!!! 0 0 ill!!! 0 0 d 0 0 11111! 0 0 hill! 0 0 I!!!!! 0 0 HIM!! 0 0 e 0 0 !lull 0 0 Ill!!! 0 0 !!!!!! 0 0 !l!!1! 0 0 • f 0 0 will 0 0 MI 0 0 I!!!!! 0 0 I!!!!! 0 0 11 Floors a 1910 1.7 0 3620 6255 0 2768 4783 0 684 1182 0 56 97 0 (Note:room b 1910 1.7 0 464 802 0 0 0 0 0 0 0 0 0 0 perimeter c 0 0 !!ltll 0 0 llllll 0 0 I!!!!! 0 0 !!11!l 0 0 is displ. d 0 0 Iiml 0 0 111!!! 0 0 111111 0 0 !!1!!l 0 0 for slab e 0 0 will 0 0 llllll 0 0 111111 0 0 111111 0 0 floors) f 0 0 mill 0 0 HIM 0 0 !!!!11 0 0 ill!!! 0 0 12 infiltration a 129 8.0 543 70178 4332 75 9693 598 30 3877 239 0 0 0 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 **** 135523 **** **** 28905 **** **** 10169 **** **** 442 **** Less external heating **** 0 **** **** 0 **** **** 0 **** **** 0 **** Less transfer **** 0 **** **** 0 **** **** 0 **** **** 0 **** Heating redistribution **** 0 **** **** 0 **** **** 0 **** **** 0 **** 14 Duct loss 6% 8131 **** 6% 1734 **** 6% 610 **** 6% 27 **** 15 Total loss=13+14 **** 143655 **** **** 30640 **** **** 10779 **** **** 469 **** 16 Int.gains: People @ 300 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Appl. @ 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0 17 Subtot RSH gain=7+8..+12+16 **** **** 29922 **** **** 5636 **** **** 1641 **** **** 65 Less external cooling **** **** 0 **** **** 0 **** **** 0 **** **** 0 Less transfer **** **** 0 **** **** 0 **** **** 0 **** **** 0 Cooling redistribution **** **** 0 **** **** 0 **** **** 0 **** **** 0 18 Duct gain 5% **** 1496 5% **** 282 5% **** 82 5% **** 3 19 Total RSH gain=(17+18)*PLF 1.00 **** 31418 1.00 **** 5918 1.00 **** 1723 1.00 **** 69 20 Air required(cfm) 1567 1567 334 295 118 86 5 3 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. AA- wrightsoft• 2022-May-25 09:40:40 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 / � ...rs\scott.langeworthy\Documents\York\REICHEN.rup Calc=MJ7 Front Door faces: N Rig ht-J®Worksheet Job: REICHEN Entire House Date: May 25,2022 By: Pfan: REICHEN MANUAL J:7th Ed. 1 Name of room Room4 Room5 Room6 Room7 2 Length of exposed wall 22.0 ft 252.0 ft 35.0 ft 11.0 ft 3 Room dimensions 8.0 x 14.0 ft 1.0 x 2518 ft 12.0 x 13.0 ft 1.0 x 109.0 ft 4 Ceilings Condit.Option 8.0 ft heat/cool 8.0 ft heat/cool 8.0 ft heat/cool 8.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg 5 Gross a 12E3 5.4 1.0 176 **** **** 2016 **** **** 280 **** **** 88 **** **** Exposed b 0 0 !!!I!! **** **** 1!!!!! **** **** IIIIII **** **** I I I I I I **** **** walls and c 0 0 I!!!ll **** **** IIIIII **** **** IIIIII **** **** IIIIII **** **** partitions d 0 0 !III!! **** **** I!!!!! **** **** Him **** **** I!!!!! **** **** e 0 0 WI!! **** **** I!!ll! **** **** win **** **** IIIIII **** **** f 0 0 IIIIII **** **** II II!! **** **** IIIIII **** **** IIIIII **** **** 6 Windows and a 3A0 39.7 ** 0 0 **** 95 3769 **** 30 1190 **** 10 397 **** glass doors b 0 ** 0 _ 0 **** 0 0 **** 0 0 **** 0 0 **** Heating c 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** d 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** f 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** 7 Windows and North 19.0 0 **** 0 40 **** 760 0 **** 0 0 **** 0 glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Cooling E/W 68.0 0 **** 0 55 **** 3740 30 **** 2040 0 **** 0 SE/SW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 South 34.0 0 **** 0 0 **** 0 0 **** 0 10 **** 340 Horz 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 8 Other doors a 11 F0 12.2 2.3 0 0 0 126 1542 291 0 0 0 0 0 0 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 176 950 180 1795 9693 1831 250 1350 255 78 421 80 exposed b 0 0 !IIIII 0 0 III!!! 0 0 11!!!! 0 0 IIIII! 0 0 walls and c 0 0 1l11!! 0 0 Ill!!! 0 0 IIIIII 0 0 III!!! 0 0 partitions d 0 0 1!1!!! 0 0 II!!!! 0 0 IIIIII 0 0 III!!! 0 0 e 0 0 will 0 0 !i!!l! 0 0 nnll 0 0 11111! 0 0 f 0 0 III!!I 0 0 !1!!!! 0 0 IIIIII 0 0 I1111! 0 0 10 Ceilings a 16G0 2.4 1.1 112 266 126 2518 5983 2825 156 371 175 109 259 122 b 0 0 11l111 0 0 III!!! 0 0 I!!111 0 0 I11!!! 0 0 c 0 0 IIIII! 0 0 In! 0 0 !HI 0 0 IIIIII 0 0 d 0 0 I!!!!! 0 0 11!I!! 0 0 !!!Ill 0 0 !Hill 0 0 e 0 0 !III!! 0 0 !III!! 0 0 l!!!!l 0 0 I!!!!! 0 0 f 0 • 0 IIIIII 0 0 IllIll 0 0 !IIIII 0 0 111!!l 0 0 11 Floors a 1910 1.7 0 112 194 0 0 0 0 0 0 0 0 0 0 (Note:room b 1910 1.7 0 0 0 0 232 401 0 0 0 0 0 0 0 perimeter c 0 0 IllI11 0 0 III!!! 0 0 1!!I!! 0 0 IIIII! 0 0 is dispi. d 0 0 Mil! 0 0 !IIIII 0 0 !1!1!! 0 0 III!!! 0 0 for slab e 0 0 Mill 0 0 I11111 0 0 111111 0 0 IIIIII 0 0 floors) • f 0 0 Ill!!! 0 0 WI!! 0 0 HMI 0 0 I111!! 0 0 12 Infiltration a 129 8.0 0 0 0 221 28562 1763 30 3877 239 10 1292 80 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 **** 1410 **** **** 49950 **** **** 6788 **** **** 2369 **** Less external heating **** 0 **** **** 0 **** **** 0 **** **** 0 **** Less transfer **** 0 **** **** 0 **** **** 0 **** **** 0 **** Heating redistribution **** 0 **** **** 0 **** **** 0 **** **** 0 **** 14 Duct loss 6% 85 **** 6% 2997 **** 6% 407 **** 6% 142 **** 15 Total loss=13+14 **** 1495 **** **** 52947 **** **** 7195 **** **** 2511 **** 16 Int.gains: People @ 300 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Appl. @ 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0 17 Subtot RSH gain=7+8..+12+16 **** **** 308 **** **** 11211 **** **** 2709 **** **** 622 Less external cooling **** **** 0 **** **** 0 **** **** 0 **** **** 0 Less transfer **** **** 0 **** **** 0 **** **** 0 **** **** 0 Cooling redistribution **** **** 0 **** **** 0 **** **** 0 **** **** 0 18 Duct gain 5% **** 15 5% **** 561 5% ** 135 5% **** 31 19 Total RSH gain=(17+18)*PLF 1.00 **** 320 1.00 **** 11771 1.00 **** 2845 1.00 **** 653 20 Air required(cfm) 16 16 577 587 78 142 27 33 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. ..:-_ wr- Frtsotrt- 2022-May-25 09:40:40 C.�A 9 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 2 ...rs\scott.langeworthy\Documents\York\REICHEN.rup Calc=MJ7 Front Door faces: N Right-J®Worksheet Job: REICHEN • Entire House Date: May 25,2022 By: Plan: REICHEN MANUAL J:7th Ed. 1 Name of room Room8 Room9 Room10 Room11 2 Length of exposed wall 9.0 ft 13.0 ft 17.0 ft 31.0 ft 3 Room dimensions 1.0 x 165.0 ft 1.0 x 163.0 ft 1.0 x 257.0 ft 8.0 x 15.0 ft 4 Ceilings Condit.Option 8.0,ft heat/cool 8.0 ft heat/cool 8.0 ft heat/cool 8.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg • 5 Gross a 12E3 5.4 1.0 72 **** **** 104 **** **** 136 **** **** 248 **** **** Exposed b 0 0 !!!111 **** **** 111111 **** **** IIIIII **** **** II1111 **** **** walls and c 0 0 IIIIII **** **** l!I1!! **** **** III!!! **** **** 1U11! **** **** partitions d 0 0 !!11!! **** **** llll!! **** **** 1!1I11 **** **** !!!!!! **** **** e 0 0 111111 **** **** II!!!l **** **** !!ll!! **** **** 111111 **** **** f 0 0 I11111 **** **** 11!!11 **** **** 111111 **** **** !!I!!! **** **** 6 Windows and a 3A0 39.7 ** 30 1190 **** 35 1389 **** 55 2182 **** 0 0 **** glass doors b 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** Heating c 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** d 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** f 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** 7 Windows and North 19.0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Cooling E/W 68.0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 SE/SW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 South 34.0 30 **** 1020 35 **** 1190 55 **** 1870 0 **** 0 Horz 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 8 Other doors a 11F0 12.2 2.3 0 0 0 0 0 0 0 0 0 0 0 0 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 42 227 43 69 373 70 81 437 83 248 1339 253 exposed b 0 0 111111 0 0 1111!! 0 0 11!I!l 0 0 111!11 0 0 walls and c 0 0 IIIIII 0 0 lll!1! 0 0 inn! 0 0 111111 0 0 partitions d 0 0 Inn! 0 0 I!!!!! 0 0 IIIIII 0 0 IllIll 0 0 e 0 0 1111!l 0 0 111I!! 0 0 111111 0 0 111111 0 0 f 0 0 !11111 0 0 1III!! 0 0 111111 0 0 11l!1! 0 0 10 Ceilings a 16G0 2.4 1.1 165 392 185 163 387 183 257 611 288 120 285 135 b 0 0 !!1!II 0 0 111111 0 0 MITI 0 0 Ill!!! 0 0 c 0 0 IIIIII 0 0 111111 0 0 IIIIII 0 0 1111!! 0 0 d 0 0 !11!11 0 0 11i11! 0 0 !!!111 0 0 111111 0 0 e 0 0 I1!!11 0 0 1111!l 0 0 11111! 0 0 IIIIII 0 0 f 0 0 Will 0 0 11!111 0 0 1!111I 0 0 !!1!!l 0 0 11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0 (Note:room b 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0 perimeter c 0 0 I!!!!I 0 0 111111 0 0 I!!III 0 0 111111 0 0 is displ. d 0 0 IIIIII 0 0 IIIIII 0 0 111111 0 0 !!1111 0 0 for slab e 0 0 IIIIII 0 0 IIIII! 0 0 111111 0 0 III!!! 0 0 floors) f 0 0 mill 0 0 IIIIII 0 0 111111 0 0 IIIIII 0 0 12 Infiltration a 129 8.0 30 3877 239 35 4523 279 55 7108 439 0 0 0 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 **** 5686 **** **** 6672 **** **** 10338 **** **** 1624 **** Less external heating **** 0 **** **** 0 **** **** 0 **** **** 0 **** Less transfer **** 0 **** **** 0 **** **** 0 **** **** 0 **** Heating redistribution **** 0 **** **** 0 **** **** 0 **** **** 0 **** 14 Duct loss 6% 341 **** 6% 400 **** 6% 620 **** 6% 97 **** 15 Total loss=13+14 **** 6027 **** **** 7072 **** **** 10959 **** **** 1722 **** 16 Int.gains: People @ 300 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Appl. @ 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0 17 Subtot RSH gain=7+8..+12+16 **** **** 1487 **** **** 1722 **** **** 2680 **** **** 388 Less external cooling **** **** 0 **** **** 0 **** **** 0 **** **** 0 Less transfer **** **** 0 **** **** ,0 **** **** 0 **** **** 0 Cooling redistribution **** **** 0 **** **** 0 **** **** 0 **** **** 0 18 Duct gain 5% **** 74 5% **** 86 5% **** 134 5% **** 19 19 Total RSH gain=(17+18)*PLF 1.00 **** 1562 1.00 **** 1809 1.00 **** 2814 1.00 **** 407 20 Air required(cfm) 66 78 77 90 120 140 19 20 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. . A -FP- wrightsoft- 2022-May-25 09:40:40 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 3 ..rs\scott.langeworthy\Documents\York\REICHEN.rup Calc=MJ7 Front Door faces: N Right-J®Worksheet Job: REICHEN Entire House Date: May 25,2022 By: Plan: REICHEN MANUAL J:7th Ed. 1 Name of room Room12 Room13 Room14 Room15 2 Length of exposed wall 27.0 ft 6.0 ft 4.0 ft 8.0 ft 3 Room dimensions 8.0 x 19.0 ft 8.0 x 6.0 ft 8.0 x 4.0 ft 11.0 x 4.0 ft 4 Ceilings Condit.Option 8.0 ft heat/cool 8.0 ft heat/cool 8.0 ft heat/cool 8.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg 5 Gross a 12E3 5.4 1.0 216 **** **** 48 **** **** 32 **** **** 64 **** **** Exposed b 0 0 IIIIII **** **** 1111!! **** **** IIIII! **** **** 111!1! **** **** walls and c 0 0 IIIII! **** **** I11!!! **** **** IIIIII **** **** !1!!!! **** **** partitions d 0 0 IIIIII **** **** IIIIII **** **** IIIIII **** **** I111!! **** **** e 0 0 IIIIII **** **** !II!!! **** **** IIIIII **** **** II!!!! **** **** f 0 0 IIIIII **** **** IIIIII **** **** IIIIII **** **** IIIIII **** **** 6 Windows and a 3A0 39.7 ** 15 595 **** 0 0 **** 0 0 **** 0 0 **** glass doors b 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** Heating c 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** d 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** f 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** 7 Windows and North 19.0 15 **** 285 0 **** 0 0 **** 0 0 **** 0 glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Cooling E/W 68.0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 SE/SW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 South 34.0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Horz 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 8 Other doors a 11F0 12.2 2.3 42 514 97 0 0 0 0 0 0 0 0 0 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 159 859 162 48 259 49 32 173 33 64 346 65 exposed b 0 0 1!!!I! 0 0 !!!!!! 0 0 111111 0 0 !111!l 0 0 walls and c 0 0 IIIIII 0 0 HI! 0 0 111111 0 0 WI!! 0 0 partitions d 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 11!!!! 0 0 e 0 0 will 0 0 !IIIII 0 0 IIIIII 0 0 !!!!!! 0 0 f 0 0 !!!!!! 0 0 huh 0 0 IIIIII 0 0 I1!1!! 0 0 10 Ceilings a 16G0 2.4 1.1 152 361 171 48 114 54 32 76 36 44 105 49 b 0 0 will 0 0 !IIIII 0 0 111111 0 0 111111 0 0 c 0 0 111111 0 0 !I11!l 0 0 111111 0 0 1111!! 0 0 d 0 0 IIIIII 0 0 !II!!! 0 0 Illlll 0 0 IIIII! 0 0 e 0 0 IIIIII 0 0 Hull! 0 0 1!!l11 0 0 !I!!!! 0 0 f 0 0 will 0 0 MI!! 0 0 111111 0 0 111111 0 0 11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0 (Note:room b 1910 1.7 0 152 263 0 48 83 0 32 55 0 0 0 0 perimeter c 0 0 l!!!MI 0 0 !1!!!! 0 0 Illlll 0 0 I!!!!! 0 0 is displ. d 0 0 !!!!1! 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 for slab e 0 0 !!1!!! 0 0 111111 0 0 111111 0 0 IIIIII 0 0 floors) f 0 0 Il!!!! 0 0 hill!! 0 0 Inn, 0 0 IIIIII 0 0 12 Infiltration a 129 8.0 57 7367 455 0 0 0 0 0 0 0 0 0 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 **** 9958 **** **** 456 **** **** 304 **** **** 450 **** Less external heating **** 0 **** **** 0 **** **** 0 **** **** 0 **** Less transfer **** 0 **** **** 0 **** **** 0 **** **** 0 **** Heating redistribution **** 0 **** **** 0 **** **** 0 **** **** 0 **** 14 Duct loss 6% 597 **** 6% 27 **** 6% 18 **** 6% 27 **** 15 Total loss=13+14 **** 10556 **** **** 484 **** **** 322 **** **** 477 **** 16 Int.gains: People @ 300 0 **** 0 . 0 **** 0 0 **** 0 0 **** 0 Appl. @ 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0 17 Subtot RSH gain=7+8..+12+16 **** **** 1170 **** **** 103 **** **** 69 **** **** 115 Less external cooling **** **** 0 **** **** 0 **** **** 0 **** **** 0 Less transfer **** **** 0 **** **** 0 **** **** 0 **** **** 0 Cooling redistribution **** **** 0 **** **** 0 **** **** 0 **** **** 0 18 Duct gain 5% **** 58 5% **** 5 5% **** 3 5% **** 6 19 Total RSH gain=(17+18)*PLF 1.00 **** 1228 1.00 **** 108 1.00 **** 72 1.00 **** 120 20 Air required(cfm) 115 61 5 5 4 4 5 6 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. 2022-May-25 09:40:40 .` w rig ht50ft' Right-Suite®Universal 2017 17.0.16 RSU25116 Page 4 i CP. ...rs\scott.langeworthy\Documents\York\REICHEN.rup Calc=MJ7 Front Door faces: N • !' . Detei , iiiniinl Your Vent i it on Net h.. l,; 171'3+ I �`�O irl:lti;i'6 ir4:',:,h Nib.41 {�t.14.1 VIP �. ?: Good air quality is based In part on the capacity end the home's ventilation system.Li^wally,the uai t"s capacity is a ' measured in CFM(Cubic Feet per Minute)or Us(Liters per second)of fresh air be r g distributed in the Dying space Use The ASHRAE 62:2 Ventilation Standard, the Room Count Calculation MMod,or the Air Change Per .,:� Hour(ACH1 Method to determineyour venfill afion needs. k V Ai'iWIR31 E Cia2.,WI i .;;1i ail 1; aQ�':k l ASHRAE 62.2 CFO Sizing Chart ' Number of Bedrooms!CFM 0 `• Floor Area(ft�) . '7 I' -t 2-3 4-g 6 7 i .: 1500 30 46 60 75 Ij 90 I•,. • 1501 -3000 f 45 60 75._._ ...� 3001 -4500 60 75 90 105 ' SAC] .� 10;7 1'2CD , ' 4501 -6000 75 90 105 120 I-' 13s t _.A, 6001 -7500 90 '105 .. . ._ . 12f3. - 135 150 ;I ' . 7500 105 120 135 150 ylm. 165 ' ,I ANSIsASHHAE,STANDARD 62 • .2.2010-Ventilation Air Requirements:values in c' l: J The above oharl outlines the minimum requirements for continuous ventllatiOn. I ;-' 3 T?6 S.TR 7 S' C F -'W f R 'Min x g 0 1 C~010 l C O(-Fin • • • • • 0 ,. MAX 205 , ,,,,, , HEAT RECOVERY VENTILATOR ENGINEERING DATA: LIFEBRERTH' ' THERMALLY CONDUCTIVE,PATENTED ALUMINUM DEFROST HEX CORE Recirculating damper defrost system. The counter-flow heat recovery core transfers heat between two airstreams.It is easily removed for cleaning or service. CASE 20 gauge prepainted galvanized steel for superior corrosion resistance,insulated to MOTORS AND BLOWERS prevent exterior condensation.Balancing ports are located on unit Each airstream has an independent centrifugal blower with multiple fan speed operation. DRAIN CONNECTION Two 1/2 in(12 mm)outer diameter. FILTERS Washable MERV-6 air filters in exhaust and supply airstreams. ELECTRONICS • Upgrade to MERV-13 option available. The DXPLO2 control included with the unit can bewail mounted in a central location of the home.3 wire 20 gauge(min.)100 ft length(maxi. MOUNTING Threaded inserts at corners of the cabinet designed to accept the"S"hooks and hanging straps supplied with the unit OPTIONAL ACCESSORIES: TechGrille Terminator Wireless 20/40/60 Kitchen Grille Weather Hoods 99-EAG4 Fitting Min Timer 10-002 r 99-EAGS 99-TM4 99 DET02 i 99 186 99-EAG6 �� 99 TMS - 99-187 99-EAGB ---' 99-TM6 , LIFEBREATH CONTROL OPTIONS TIMER OPTIONS 99-DET01-Lifebreath 20/40/60 Minute Tinier FEATURES 99-DXPLO2 99-BCO2 : 99-BC03 ' 99-BC04 Initiates high speed ventilation for 20,40 or 60 minutes.3 wire connection. 5 speed fan operation on each mode V 99-DET02-Wireless Lifebreath 20/40/60 2 speed fan operation(Low/High) V V Minute Timer Initiates high speed ventilation for 20,40 or 60 ✓ Continuous low speed fan operation minutes.Wirelessly connects to main control for Humidity control through adjustable Dehumidistat ✓ ✓ ✓ ease of installation.40'approximate range. Exclusive to Lifebreath. Large digital LCD screen ✓ 99-RX02-Wireless Lifebreath Repeater LED status indicator lights V V V Extends range of 99-DET02 Wireless Timers.Plugs into 120V power outlet.Wirelessly connects to Continuous Ventilation V V main control and 99-DET02.Install at halfway point between timer and main wall control if timer Continuous Recirculation ✓ V is out of range. 20 ON/40 OFF V e x 10 ON/50 OFF V 20 ON/40 Recirculation V V V 20/40/60 min.High speed override button -- Compatible with 99-DET02Wireless Timer V V V V 99-DXPLO2 99-DET02 3 wire connection V V V V •. L IFEBRERI TI,I III 1 Indoor Air Systems 69-205 MAX 0921 www.lifebreath.com o 1 , [. . .,, . ,,, , , 205 MAX 4,, ,s : HEAT RECOVERY VENTILATOR i LIFE BRERTH' PERFORMANCE (HVI CERTIFIED) ----- __� 0.1(25) 1 0.2(50) iI 0.3(75) 0.4(100) 0.5(125) 0.6(1S0) CO(175) ELECTRICAL SPECIFICATIONS IN.W.G.(PA) CFM(Vs) , CFM(V5) II CFM(Vs) CFM(Vs) CFM(Vs) CFM(Vs) CFM(V5) __ _ IL_ _ _-- _ -- _ __ 11 _ VAC@ 60Hz 120 Net Supply Airflow 203(96) 193(91) 182(86) 172(81) 159(75) 148(70) 136(64) Watts/Low Speed 64 Gross Supply Airflow 208(98) 197(93) 186(88) 174(82) 163(11) 150(11) 138(65) Watts/High Speed 96 Gross Exhaust Airflow 212(100) 199(94) 186(88) 172(81) 159(75) 144(68) 129(61) Amp Rating 1.4 Sensible Effectiveness(ASE) zso @ 64 CFM(30 Us) 32°F(0°C) 85% WEIGHT: 57 LBS(25.8 KG) Sensible Efficiency(SRE) 200 32°F(0°C) 16% @64 CFM(30Us) SHIPPING WEIGHT: Sensible Efficiency(SRE) E 67 LBS(30 KG) @ 100 CFM(41 Us) 32°F(0°C) 73% v lso 3 0 Sensible Efficiency(SRE) -13°F(-25°C) 10% a too NOTE: @ 102 CFM(48 Us) Front clearance of 25 in.(635 mm) is recommended for servicing unit.All so ducts use 5 in.(125 mm)round collars. MERV13 Upgrade:65-195-6R r e -Igittl•• ISO <o.�ra_ r irm9001 C .,u U3 CERTIFIED ritim IIm 0.2 0.4 0.6 0.8 1.0 a.� Static Pressure(in w.g.) DIMENSIONS n �l, FRONT VIEW TOP VIEW 6 in. �( V Filter f t (150 mm) - I I-1 I Collars - — — r Recirculating 1 I I Stale air to outside Defrost Damper I t 1 CO 1 _ / Q i iFresh airfrom outside FS �/�oag� �off` E� IStleifidRemovable Heat t o _ _ V - * Fresh air to inside Recovery Core fl ' / - / i co - _ — Motorized/ I '- '— Impeller . I♦ , Condensate 33 5/8 in.(854 mm) Drain 11 Date: Contractor: WARRANTY Units carry a lifetime warranty on the HRV core and a Syear Tag: Supplier: replacement parts warranty. All units conform to CSA and UL standards Project: Qty: quote#: Engineer: Submitted By: NO Control: Timer: Timer Qty: L/FEBREfITH° If Indoor Air Systems 69-205 MAX 0921 www.lifebreath.com RS,?prR JEi, �, T }� r S YY ("• .O _S� • T Cox � S 1�]V a+ � n"M� ,r,•,.si',+ R f.?.. E'�.+..vFr.. cYe 73 Sheridan Street,Glens Falls,NY 12801 Phone-518-796-2515 June 3,2022 Project#374 Fred Smith Smiths Excavating 354 Luzern Road Queensbury,NY 12804 Re: Proposed New Septic System Design&Percolation Test Results 14 Twin Mountain Drive,Queensbury,NY Dear Fred: At your request, we performed a percolation test for a proposed 3-bedroom house at 14 Twin Mountain Drive in Queensbury. As per our conversation the new residence will be constructed on a existing vacant lot. On 6/3/22 we performed a percolation test at a depth of 24 inches in a 30-inch-deep hole. The percolation test revealed a,stabilized percolation rate of 1 minute 10 seconds. We have reviewed the proposed septic system design and we agree that standard absorption trenches are acceptable. Based upon a design flow rate of 330 GPD and a percolation rate of 1 to 5 minutes, you will need a minimum of 275 sf of absorption area or 138 if of absorption trench length. We recommend using 3 — 50 ft long absorption laterals for a total system length of 150 ft. The absorption system can be constructed with the new 1,000-gallon septic tank, new distribution box,and 4-inch diameter perforated pipe and stone. Please feel free to contact me at 796-2515 if you have any questions and that you for your assistance with this request. Sincerely, . Thomas R. Center Jr,P.E. JUN ® � 7-e14, o� 9?p?? (INN G&c�se�R 308.9-1-1-1 RC-0360-2022 Reichen, Jessalie & Mark 14 Twin Mountain Dr SFD w/gas fp 2555 s.f., Garage 938 s.f. _. • • . g © r9� .... -. ._ .. .._ _.. .... . . _ . . ... - _. . .......;,.....„,re10. . . _ . . ___ .. .. (.J . is- n i ... . _. .. _ _. . .. . . . . . . . .. . - . -- I ENTER PROJEW SERVICES 73 Sheridan Street, Glens Falls,NY 12801 Phone-518-796-2515 July 17, 2023 Project#374 Fred Smith Smiths Excavating 354 Luzerne Road Queensbury,NY 12804 . Re: Proposed New Septic System Design& Percolation Test Results 373 West Mountain Road, Queensbury,NY Dear Fred: At your request, we performed a percolation test for a.proposed 3-bedroom house with a 5 bedroom design for 2 future bedrooms at 373.West-Mountain Road in Queensbury. As per our. conversation the newresidence will be constructed on a existing vacant lot. , ' On 6/3/22 we performed a percolation test at a depth of 24 inches in a 30-inch-deep hole. The percolation test revealed a stabilized percolation rate of 1 minute 10 seconds. We have reviewed the proposed septic system design and we agree that standard absorption trenches are acceptable. Based upon a design flow rate"of 550 GPD and a percolation rate of 1 to 5 minutes, you will need a minimum of 612 sf of absorption area is required. A 20 ft wide by 40 ft long absorption' bed with 4 --35 ft long laterals may be installed for the proposed absorption bed. The absorption system requires a new 1,500-gallon septic tank, new distribution box, and 4-inch diameter perforated pipe and stone. Please feel free to contact me at 796-2515 if you have any questions and that you for your assistance with this request. Sincerely, ." Thomas R. Center Jr, P.E. ' )' i TOWN Oh QUEENSBURY j ------' , BUILDING & CODES P . ___-,--- --- •••• i e o e .•^",...... C. AS BUILT It- . \\\ , .4., -.... ._ \ .. 1 A-1-- .)....1---- . ...._: - _ br urx‘ \ y- 0\c ca \ ' r C) - P ..7 4e*Sk r., \ .., , - , • .,,Z• mmmmmmim anrvmoi mim U IIII� i P4l S I' fi, ( Ti 0 I111 518.832.9213 1 ryan@clearvuinspections.com 1 18 Blackberry Lane,Queensbury,NY 12804 McQueen Fine Home Building 2138 State Route 149 Fort Ann, New York 12827 rmfinehomebuildinq@qmail.com 518.361.0239 ClearVU Inspections, performed a one-point airtightness, blower doortest on the single family dwelling at 373 West Mountain Road,Queensbury, NY,to determine the air changes per hour on January 05,2024.The dwelling was depressurized and the testing procedure performed as per IECC- R402.4.1.2. Test conditions were as follows: Fan location -garage door 350'above sea level 968 CFM50 30°F outside air temperature 65°F inside air temperature Pre-Test Baseline Building Pressure -0.7 Pa -50.0 Pa testing pressure TEC DG-1000& Model 3 Fan Altitude Correction Factor=(1+(.000006 x altitude))x CFM50 = n/a Results:( 968 CFM50 x 0.966 x 60 Minutes)/( 49,145 cubic feet) _ 1 .142 ACH50 IECC-R402.4.1.2-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ASTM E 779 or ASTM E 1827 and reported at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed atthe time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. Ryan Wild ClearVU Inspections BPI IDL Certification - 5063518 Asbestos Sampling & Handling License- 879660/282890 NYS Home Inspector License- 16000085839 LA GEO VARIANCE REQUEST: BoM VARIANCES APPROVED D£C£A/B£R 2= THE PROPOSED LOCATION OF THE PROPOSED WASTEWATER REPLACEMENT WILL BE POSITIONED SO THAT IT WILL NOT BE IN CONFORMANCE WITH BUILDING SETBACK STANDARDS, THE PROPOSED WASTEWATER SYSTEM REQUIRES MULTIPLE VARIANCES DESCRIBED BELOW. VARIANCE REQUESTS TO THE TOWN OF QUEENSBURY WILL BE REQUIRED FOR THE FOLLOWING. V-1: ABSORPTION BED TO BUILDING FOUNDATION — REQUESTED 15' IN LIEU OF THE 20' REQUIRED V-2: SEPTIC TANK & PUMP TANK TO BUILDING FOUNDATION — REQUESTED 5' IN LIEU OF THE 10, REQUIRED WASTEWATER SYSTEM — BA51S OF DESIGN REGULATORY AUTHORITY. TOWN OF QUEENSBURY DESIGN STANDARDS: NEW YORK STATE DEPARTMENT OF HEALTH (IONYCRR APPENDIX 75—A), WASTEWATER TREATMENT STANDARDS — INDIVIDUAL HOUSEHOLD SYSTEM. TOWN OF QUEENSBURY ORDINANCE — CHAPTER 136: SEWERS AND SEWAGE DISPOSAL — PART 1, ON —SITE SEWAGE DISPOSAL SYSTEMS PROJECT DESCRIPTION: THE PROPOSED WASTEWATER SYSTEM TO SERVE THE THREE (3) BEDROOM RESIDENCE SHALL CONSIST OF A 1,000 GALLON PRECAST CONCRETE SEPTIC TANK, 1,000 GALLON PRECAST CONCRETE PUMP TANK, IF NECESSARY, PRECAST CONCRETE DISTRIBUTION BOX AND A 15' X 28' (420 SF) STONE BED WITH INFILTRATOR H2O GRAVELLESS OPEN —BOTTOM CHAMBERS TO DISTRIBUTE FLOWS. PROJECTED FLOWRATE: BASED ON A THREE (3) BEDROOM COUNT AND NYS DOH STANDARDS FOR POST 1991 WATER SAVING FIXTURES & 110 GALLONS PER DAY PER BEDROOM, THE AVERAGE DAILY FLOW (ADF) IS 330 GALLONS. SHOULD HOUSEHOLD FIXTURES NOT BE OF THE 'LOW FLOW' TYPE MANUFACTURED SINCE 1991 THEN THE FIXTURES SHALL_ BE REPLACED AS NEEDED. THIS FLOWRATE DOES NOT INCLUDE THE USE OF A GARBAGE GRINDER (NOR IS ONE RECOMMENDED) OR A HOT TUB/SPA. ADDITIONAL FLOWRATE MUST BE INCLUDED IN THE DESIGN SHOULD EITHER OF THESE COMPONENTS BE PART OF THE HOUSE DESIGN. ABSORPTION FIELD SYSTEM: THE ABSORPTION SYSTEM IS DESIGNED AS 420 SF OF ABSORPTION BED PER NYSDOH APPENDIX 75—A TABLE 7A AND CONSIST OF TRAFFIC RATED OPEN BOTTOM GRAVELLES CHAMBERS BY INFILTRATORS. THERE WILL BE A TOTAL OF 3 LATERALS AT 24 LF EACH WITHIN THE BED TO DISTRIBUTE FLOWS WITHIN THE BED. SITE LOCATION MAP SCALE: 1 " = 2,000' L NDS OF ROBER VANDERHYE B OK 1205 OF DEEDS AT AG 222 LAKE WATER SUPPLY EX DWELLING 1 1 1 'E 1 100' MHW SETBACK 1 163. 83. 1 I II II I •:� TP#1 13 BEDROOM 1 DWELLING STEPPING STONES ' I '`may• I� /V82 25'00 "Wi ALO APPARENT DRAIN FIELD AREA, TO BE ABANDONED i 165 I LAN S N/F OF D'AMB OSIO FAMIL Y TF BOOK 5215 OF DEE S AT PAGE 133 LAKE WA TER SUPPLY EX D#QLING I EXISTING CONDITIONS SCALE: 1 " = 20' ST Q 2 TP#2 WASTEWATER ABSORPTION FIELD DESIGN CALCULATIONS: THE PROPOSED ABSORPT70N FIELD WAS DESIGNED IN ACCORDANCE WITH NYSDOH APPENDIX 75A AS FOLLOWS DESIGN PERCOLATION RATE = 1-5 MIN/IN TOTAL BEDROOM COUNT = 3 DESIGN FLOW = 110/GAL/DAY/BR 110 X 3 = 330 GAL/DAY APPLICATION RATE = 0.95 GAL/DAY/SF REQUIRED ABSORPTION AREA = 347 SF TOTAL PROPOSED ABSORPTION BED = 15' X 28' = 420 SF TOTAL NOTE: 1. WATER SUPPLY FOR THIS PROPERTY IS FROM LAKE GEORGE 2. NO NEIGHBORING WATER WELLS ARE WITHIN 100 FT OF PROPOSED WASTEWATER SYSTEM 3. ALL NEIGHBORING PROPERTIES TAKE WATER SUPPLY FROM LAKE GEORGE UNLESS NOTED OTHERWISE SURVEY NOTE. BOUNDARY OBTAINED WA PUBLIC GIS DATA AND ARE NOT DEEMED SURVEY ACCURATE. EXISTING CONDITIONS SHOWN HEREON OBTAINED VIA DRONE AERIAL IMAGERY FROM ENVIRONMENTAL DESIGN PARTNERSHIP AND NOT DEEMED SURVEY ACCURATE. SOIL DATA: THE FOLLOWING TEST PITS WERE PERFORMED ON DECEMBER 15, 2022 AND WERE OBSERVED BY ENVIRONMENTAL DESIGN PARTNERSHIP, LLP. THE RESULTS ARE AS FOLLOWED P,,f1: 0" — 8" TOPSOIL 10' — 72" LIGHT BROWN FINE SANDY LOAM TP02: O" — S. TOPSOIL 10' — 60" LIGHT BROWN FINE SANDY LOAM PTA1: STABILIZED RATE ® 2 MIN 30 SEC/INCH PT#1: STABILIZED RATE ® 3 MIN 15 SEC/INCH 11100' WELL SETBACK / ALO EXISTING SEPTIC TANK TO BE REMOVED Q O O � m W Q GENERAL SANI TAR Y NOTES., 1. MAINTAIN 100' SEPARATION BETWEEN SEPTIC SYSTEM AND ANY WELL. CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING WELLS PRIOR TO CONSTRUCTION. 2. MINIMUM SEPARATION BETWEEN SEPTIC TANK AND BUILDINGS SHALL BE 10 FEET. J. MINIMUM SEPARATION BETWEEN EDGE OF TRENCHES AND TOE OF FILL (RAISED SYSTEMS) AND BUILDINGS SHALL BE 20 FEET. 4. MINIMUM SEPARATION BETWEEN PROPERTY LINE AND EDGE OF TRENCHES OR TOE OF FILL (RAISED SYSTEMS) SHALL BE 10 FEET. 5. MINIMUM SEPARATION BETWEEN ANY WELL AND SEPTIC TANK TO BE 50 FEET. L. W. S. 6. ALL CONSTRUCTION TO BE IN COMPLIANCE WITH THE NEW YORK STATE SANITARY CODE. SI TE 7. REQUIRED INSPEC77ONS (TO BE PERFORMED BY PROFESSIONAL ENGINEER): A) PRIOR TO PLACEMENT OF SEPTIC TANK OR COMMENCEMENT OF THE TILE FIELD CONSTRUCTION. L. W. S. B) DURING THE INSTALLATION OF ANY REQUIRED FILL MATERIAL. C) PRIOR TO BACKFILLING BED AREA. D) FINAL INSPECTION UPON COMPLETION OF THE SYSTEM. O LAKEGEORGE 8. CRUSHED STONE SHALL 8E CLEAN, DURABLE AND NO SMALLER THAN OR LARGER THAN 1-1/2" DIAMETER. Z L. W. S. 9. WHEN THE BED AREA HAS BEEN EXCAVATED, THE SIDES AND BOTTOM SHALL BE RAKED TO SCARIFY cL ANY SMEARED SOIL SURFACES. 10. CONSTRUCTION EQUIPMENT NOT NEEDED TO CONSTRUCT THE SYSTEM SHOULD BE KEPT OFF THE AREA L.W.S. co TO BE UTILIZED FOR THE ABSORPTION BED SYSTEM TO PREVENT UNDESIRABLE COMPACT70N OF THE SOILS. 11. THE SYSTEM DESIGN DOES NOT INCLUDE PROVISIONS FOR GARBAGE GRINDERS. IN THE EVENT THAT `Z GARBAGE GRINDERS ARE TO BE INSTALLED, THE CONTRACTOR SHALL NOTIFY ENGINEER PRIOR TO SEPTIC INSTALLATION FOR NECESSARY MODIFICATIONS. 12. FOOTING DRAINS, SUMP PUMPS OR WATER SOFTENER DISCHARGES SHALL NOT BE CONNECTED INTO THE SEPTIC SYSTEM. 13. CONTRACTOR TO COMPLY WITH ALL O.S.H.A. AND OTHER STATE AND LOCAL SAFETY REQUIREMENTS DURING CONSTRUCTION. 14. AS PER NEW YORK STATE INDUSTRIAL CODE 53: CALL 1-800-962-7962 TO LOCATE BURIED CABLES, OR OTHER UNDERGROUND UTILITIES, NO LESS THAN TWO, OR MORE THAN TEN WORKING DAYS, PRIOR TO DIGGING, DRILLING, EXCAVATING, DRIVING POSTS, ETC. SI �TE VICINITY MAP SCALE: 1 " = 200' LA GEO 35 BUILDING MIN SLOPE WASTEWATER PLAN SCALE: 1" = 20' L NDS OF ROBER VANGERH YE Lin222 WATER 100' MHW SETBACK _ I 163 83' I I II II I I 13 BEDROOM 1 DWELLING I I 5 1 15' I J L_ 1 10, 1 165. 7 I LAN S N/F OF D'AMB OSIO FAMIL Y TR ST BOOK 5215 OF DEE SAT PAGE 133 / LAKE WA TER SUPPLY EX DWELLING 1 I / I VACANT WELL >100' BR� LANE u.t�. . J NOV 14 22 TO VAI OF CU 7�. 100' WELL SETBACK 3 m N �j O � vJ Q PRECAST CONCRETE DISTRIBUTION BOX, REFER TO DETAIL 2" PE FORCEMAIN 1,000 GALLON PRECAST CONCRETE PUMP TANK 11,000 GALLON PRECAST CONCRETE SEPTIC TANK TOWN OF QUEENSBURY BUILDING DEPARTMENT Based on our limited e•amination, compliance with our comments shall not be construed as indicating the plans Hnd specifications are in full compliance with the Building Codes of New York State. TOWN OF QUEENSBURY BUILDING & CODES WPT. Reviewed By: Date: �%z:; -Z FILE COPY I 239.12-2-23 SEP-0040-2023 Weinman, Linda 71 Assembly Point Rd Septic Variance/Alteration GRAPHIC SCALE FULL SIZE. 22" X 34" GRAPHIC SCALE REDUCED SIZE. 11" X 17" 20 15 10 5 0 20 40 80 40 30 20 10 0 40 80 160 (IN FEET) (IN FEET) 1 INCH = 20 FT. 1 INCH = 40 FT. 0 Z Z : C3 � N M Lu", o► N N W N O = N N r CT co 0 W �i- 04 LL Uaz Z Q W z 5 ` G WW H U Q J 0- W � Q ry or-0LU "I W Z F ce 0 Q 0. dl W z vI W Z VJ WJ Of QI 1 ►� W ?� W WW W 0 Z r V DRAWN BY CVO CHECK BY BMF EDP PROJECT NUMBER XXX E AL7ERA7ION OF 7HESE DOCUMEN7S IN A WAY, UNLESS ONE UNDER 774E DIRECT SUPERVISION OF A COMPARABLE OFESSIONAL• (l.E.) ENGINEER FOR AN ENGINEER, OSCAPE ARCHITECT FOR A LANDSCAPE ARCHITECT OR RWYOR FOR A SURVEYOR, /S A VICLA77ON OF 7HE NEW K STATE EDUCATION LAW AND/OR REIXHA77ONS AND IS A CLASS A' MISDEMEANOR. REVISION DATE BY SUBMITTAL TO TOWN FOR BOH REVIEW p1/30/23 CVD OF NEB \ y, P �(R0N 0 co r � cJs�OA 09602�3 \ ROFES S IONP SCALE: ill= 20' SHEET TITLE: WASTEWATER REPLACEMENT PLAN SHEET: 1 of 2 i OGRI (I 11 ,000 OR TENSAR BX1100) GEOGRID MUST EXTEND YON FHEFOOTPRINT OF THE CHAMBERS i . FILTER FABRIC 2 - 2" WASHED, CRUSHED STONE NOT TO SCALE FINISHED GRADE z REMOVABLE COVER 4' OF 4" PVC PIPE TO r v REDUCE FORCE MAIN VELOCITY PRIOR TO ENTERING BAFFLE D-BOX INVERT ELEV. -� 2" FORCE MAIN OUTLE­ Z COMPACTED CLEAN SAND OR PEA GRAVEL REDUCER AS NEEDED TO MAKE 2" TO 4" CONNECTION NOT TO SCALE NOTES: 1. PIPE JOINTS TO BE SEALED WITH ASPHALTIC MATERIALS OR EQUIVALENT. 2. INVERT ELEVATIONS OF ALL OUTLET PIPES MUST BE EQUAL. 3. THE SLOPE OF TEE OUTLET PIPES BETWEEN THE DISTRIBUTION BOX AND THE DISTRIBUTOR LATERALS SHOULD BE 1/8" PER FOOT. 4. CONTRACTOR TO USE SPEED LEVELERS AS SUPPLIED BY FORT MILLER TO EQUALIZE FLOW. SET BY WATER LEVEL METHOD. 5. USE REDUCERS AS NEEDED TO MAKE THE 4" TO 1 J" CONNECTION PRIOR TO ENTERING DISTRIBUTION BOX. 6. FORCE MAIN SHOULD SLOPE BACK TOWARDS PUMP AT NO LESS THAN 3% SLOPE TO PREVENT FREEZING OF PIPE. 1 /2, 5' CONCRETE: 4000PSI REINFORCEMENT: ASTM A615-GRADE 60 ASTM A185-GRADE 65 ENRAINED AIR: 5.0%-9.0% MEETS ASTM C890 12 24" TAPERED HOLE & PLUG (TYPICAL) 1000 GAL. 5'-q„ THE SLOPE OF THE INLET PIPE BETWEEN THE RESIDENTIAL UNIT AND THE SEPTIC TANK TO BE Y4" PER FT. 1000 GAL. 8'-8j" iIGH DENSITY POLYETHYLENE PIPE SEALS PROVIDED AT ALL PIPE CONNECTIONS SHOWN. *TANK SIZE WEIGHTS, LBS GALLONS TOP SLAB *BOTTOM I TOTAL 1000 2173 1 7436 1 9609 *INCLUDES BAFFLE 000 GALLON SEPTIC TANK NOT TO SCALE 30" FRAME AND COVER TO BE HEAVY DUTY PLASTIC FRAME AND PRECAST PLASTIC COVER ASSEMBLY BY POLYLOK RISER BY POLYLOK OR FIX FLOAT BRACKET OR EQUAL EQUAL AS NECESSARY TO TOP OF TANK OR 12' t RISER SECTION - �. PRECAST CONCRETE `^' '• PUMP CHAMBER (1000 GAL OPTIONAL SEPTIC TANK) W/ 30" OPENING GUIDE RAIL BY UTOPIA ENTERPRISES OR EQUAL m SYSTEM N: m BY CONERY 1011, FLE:XIB'._E BOOT TIMER MANUFACTURING00 ' TYPE CONNECTOR (TYP.) OVERRIDE AOBE TO CONTROL PANEL `n • ' ALARM AT HOUSE -SEE NOTE r FLOAT ~- SEPTIC TANK a .t TO 4" PVC AT 1% MIN. —� :2°`• UNION A TURN BALL VALVE DRAIN BACK DISCONNECT VALVE FOR COLD CLIMATES AND SEASONAL APPLICATIONS w ~ I —I I I FLOW 01 w I H LO Z I I (—_I I - TO DISTRIBUTION BOX w 2" PVC N -' - BALL CHECK VALVE d; I 2" PVC FORCE MAIN TIMER40 IIIII-I I ENABLER -III- `.' FLOAT SUBMERSIBLEEFFLUENTPUMP- <.:•. ° ...: A • ; .�• .: - .: ;• :..,..•..P :�•.. MODEL PUMPS ,STONE_ OR APPROVED EQUAL III _6" MIN CRUSHED III- CRUSHED STONE BACKFILL TO LEVELING FOUNDATION III=I I SPRINGLINE OF PIPE (TYP.) III' UNDISTURBED,SUBGRADE-- IIII -III-III1 L- NOTE: 'III IIIII I IIIII I II I l I I I1 I I I IIIII i ; ,III -I -ALL PIPE CONNECTIONS TO USE �11_II I111I I Il PRESSURE FITTINGS -CONTROL PANEL TO BE A TIME DOSE PANEL-SJE RHOMBUS IFS SERIES OR EQUAL -FLOAT SETTINGS TO BE DETERMINED BY THE ENGINEER DURING WASTEWATER SYSTEM STARTUP SIMPLEX Ply P PIT NOT TO SCALE oloq i 0 co cM NN W o Z N N (y) o uj NLL Q I- u Z W c Z G W LU U Q ^J � CL W�y/ 0L 0 LL Lij W Z i- o Q a. J W z m } U) W D Z Q U) 00 co � Q Z 0� W Q I,. W Z U _ aLLo LL O ui � O � f— Z O � Z) � U 0-000 DRAWN BY CVD CHECK BY BMF EDP PROJECT NUMBER XXX E AL7ERA770N OF THESE D0CUMEN7S IN WAY, UNLESS )ONE UNDER THE DIRECT SUPERNSION OF A COMPARABLE ROiESSICNAI, (LE) ENGINEER FOR AN ENGINEER, OSCAPE ARCHITECT FOR A LANDSCAPE ARCHITECT OR RVEYOR FOR A SURVEYOR, IS A WOLA77ON OF THE NEW K STATE EDUCA77ON LAW AND/OR R£d/LA77ONS AND IS A CLASS A" MISDEMEANOR. REVISION DATE BY SUBMTITAL TO TOWN FOR BOH REVIEW 01 /30/23 CID f�. OF NEW �\ 0 R0/vF O GD r_ cc_ .I C7 Ll/ 09602� \\ R�FESSIONP SCALE: N.T.S. SHEET TITLE: WASTEWATER DETAILS SHEET: 2 of 2 m 3§ u m 3§ u Y 1' 1n 1 1 I 1 1 I 1 I i 1 I uj : GENERAL NOTES INFORMATION SHOWN ON THIS DRAWING IS TAKEN FROM A SURVEY DRAWING PREPARED BY VAN DUSEN & STEVES LEGEND - - - - - - — PROPERTY LINE ---------------------- PROPERTY LINE SETBACKS ---------- 330---------- EXISTING CONTOURS 330 NEW CONTOURS E - E - E - E UNDERGROUND ELECTRIC SERVICE —. ss — ss — ss — ss — SANITARY SEWER — w — w — w — w WATER SERVICE E/P EDGE OF PAVEMENT —GAS- GAS- GAS- GAS- UNDERGROUND GAS SERVICE SITE DATA PROPERTY ZONING CLASSIFICATION: MDR (MODERATE DENSITY - RESIDENTIAL) MINIMUM LOT SIZE: 2 ACRES (WITHOUT PUBLIC WATER & SEWER) MINIMUM LOT WIDTH: 100 FEET TAX MAP NUMBER: 308.9-1-11 & 13.1 SETBACKS FRONT SHORELINE SIDE REQUIRED 30'-0" 75'-0" 25'-0" REAR 30'-0" MAXIMUM BUILDING HEIGHT 403-0" MINIMUM PERCENT PERMEABLE 50% ACTUAL LOT SIZE: 35,257 SF (0.81 ACRES) ACTUAL FRONTAGE: 119.96 FEET (TWIN MOUNTAIN ROAD) PROPOSED 50'-0" NA 29'-10" 34'-11" 157'-10" 24't 81.62% PROPOSED SITE COVERAGE CONDITIONS COMPONENT AREA PERCENTAGE TOTAL SITE 35,257 SF 100.0% BUILDINGS 4,002 SF 11.35% PAVING & WALKS 2,477 SF 7.03% GREEN SPACE 28,778 SF 81.62% 20 10 0 10 20 40 GRAPHIC SCALE 1" = 20'-0" In q =r Ln N Ln � 5 c. cog � � n W N O We 00 O � N 7h N k flZ it JUAI 09 2022 o' THE SEAL BELOW IS AN ORIGINAL SEAL AND IS IN RED INK. ONLY SEALS IN RED INK SHALL BE CONSIDERED TRUE ORIGINALS No.1 DESCRIPTION I DATE REVISIONS W N 0 N Q O U z z z�Q U=Cz W a O 0 W Ld W W (7 � T U o ...L U<JLr) Z n/ LL all ¢_ o ~ Q WoLl o 0 J 2 Y E W U 1- FF ' o o a 2 3 00 N N N o Z=o O~ Of v ��0 :2-0 J ob i a= 3} �� oz} Cn L �z - o »z U z (� aDODt aQ z � nLn N �� (n() J C) x Ip F QQ - o� o _ �Xo 0 0f �� w of L C5 > L° WORK IS TO BE AS SHOWN & NOTED AND IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, TRADE ASSOCIATION PUBLISHED RECOMMENDATIONS AND GENERALLY ACCEPTED LOCAL CONSTRUCTION INDUSTRY PRACTICES. ��V'1 O �I pp N • ,!�� l\ U 000 - V � a c'�7� �] ct N CAD FILE NAME ACAD\MCQUEEN\REICHEN\C-1 SCALE AS NOTED DRAWN BY DRAWING TITLE CONCEPTUAL SI TE PLAN DRAWING No. C-1 M V RL O +1 V m L.L. Q CL M N N N 0 N Ol N M c a a� in O N V c a� -a N a) L V Q) cao .5 m C a� a� 3 0 L— 1 rre$vns+d eAri$4 r.r1F4�nn$n.., err+ $renal �isare=ee.+rs v�eer,.ah:teave s34 aenener r3e�•F6ra�$terne r�t�n