Loading...
SEP-0614-2021 SEPTIC VARIANCE Office Use Only Received: 1 z APPLICATION Permit#: cJ�-� — Off- 2o2-1 Town of(jurrn.Gun Permit Fee: I k.25'f 742 Bay Road,Queensbury,NY 12804 6, P:518-761-8256 www.queensbury.net Invoice#: 0�J Approvals: Submittal: I original&8 copies of the completed application package Property Owner(s):_ Mary E. Sheehan Irrev. Trust Owner's Agent: Fthan P. Hall - Rucinski Hall Architecture Address: 11011 Queens Blvd -Apt 26L Address: 134 Dix Ave Forest Hills NY 11375 Glens Falls NY 12801 Phone#: 917-763-5656 Phone#: 518-741-0268 Site Address: 80 Rockhurst Road, Qby Tax ID#: 227.13-2-42 Directions to Site: Property is located on Rockhurst- Sheldon Point Lake George off Cleverdale Road Distance from well on property to septic system (if applicable) NA feet Is it possible to install a conforming septic system on this property? Yes X No If YES,please explain and attach a diagram: Does the proposed system meet setback requirements for distance from wells&septic systems on neighboring properties? x Yes No If NO,please explain: Is the proposed system to be installed under a parking area? Yes X No Section of the Sanitary Sewage Ordinance from which you are seeking the variance (i.e. leaching system will be 89 ft. from well in lieu of required 100 ft.): The property does not allow for a sewage disposal system to be installed that meets the separation distance requirement to the lake or the property lines so a holding tank system is being proposed. Setback distance from the existing home to the holding tanks is 4'-0" where 10'-0" is required. The setback distance from the tanks to the property line is 2'-8" on the south and 4'-8" on the west where 10'-0" is required. D ECEIIVEn -11 AUG 19 2021 ig } TOWN OF QUEENSBURY Septic Variance Application BUILDING&CODES February2018 J . List the names, parcel addresses, and tax map numbers of all adjoining property owners. You may obtain tax map numbers from the Assessor's Office as well as the names and addresses: North Name LG Legacy LLC Address 2 Dallas Drive, Poughkeepsie NY 12603 Tax Map ID 227.13-2-41 South Name Matthew &Jeanne Lucas Address 59 High St. Needham Heights MA 02494 Tax Map ID 227-13-2-43 East Name Lake George Address Tax Map ID West Name William & Jeffrey Clark Address 547 Bridgeview Drive, LeMoyne PA 17043 Tax Map ID 227.13-2-35 OWNER STATEMENT I/We do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at: 80 Rockhurst Drive I/We realize that putting the well,septic tank or leaching system less than the required 10 feet from the home may increase the risk of pollution. Owner—Print Name: -Joseph Sheehan -Trustee - Mary E. Sheehan Irrev. Trust Date: 27 July 2021 Owner—Signature: 49 Sivasfrt. Date: 27 July 2021 NEIGHBOR OR TENANT RELEASE STATEMENT (if applicable) I/We do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at: I/We realize that putting the septic tank or leaching system less than the required feet from the may increase the risk of pollution. Neighbor/Tenant—Print Name: Date: Neighbor/Tenant-Signature: Date: Septic Variance Application February 2018 • AUTHORIZATION AND SIGNATURE PAGE This page includes the Authorization to Act as Agent form, engineering fee disclosure, authorization for site visits,other permit responsibilities and agreement to provide documentation required. Complete the following if the OWNER is using an Agent: Owner's Name: Joseph Sheehan -Trustee - Mary E. Sheehan Irrev. Trust Designates: Fthan P Hall - Rucinski Hall Architecture as agent regarding the Septic Variance for Tax Map#: 227.13-2-42 OWNER'S SIGNATURE: 96,4 �`'/ DATE: 27 July 2021 Engineering Fee Disclosure:Applications may be referred to the Town consulting engineer for review of septic design,storm drainage, etc. as determined by the Town Board of Health. Fees for engineering review services will be charged directly to the applicant. Authorization for Site Visits: By signing this page and submitting the application materials attached herein,the Owner,Applicant and his/her/their agent hereby authorize the Town Board of Health, building and code Enforcement Officers and Town Engineer to enter the subject properties for the purpose of reviewing the application submitted. Please Note: Other permits may be required for construction or alteration activity subsequent to approval by the Town Board of Health. It is the applicant's responsibility to obtain any additional permits. Officiatial Meeting Minutes Disclosure: It is the practice of the Town Board of Health to have a designated stenographer tape record the proceedings of the meetings resulting from the application, and that the minutes transcribed from those tapes constitute the official record of all proceedings. If there is a discrepancy between such record and the handwritten minutes taken by the designated stenographer,the handwritten minutes shall be deemed the official record. I,the undersigned, have thoroughly read and understand the instructions for submission;agree to the submission requirements and completed checklist: OWNER—PRINT NAME: Joseph Sheehan -Trustee - Mary E. Sheehan Irrev. Trust OWNER—SIGNATURE: 9"1.4,4 5W42/24,t, DATE: 27 July 2021 AGENT—PRINT NAME: Ethan P. Hall - Rucinski Hall Architecture AGENT—SIGNATURE: OY1a-PP 7 DATE: 27 July 2021 Septic Variance Application February 2018 4" PVC SCH-40 MIN. SLOPE 1/4" PER FOOT NISHED LAWN AREA 12"t GRAVEL COVER Elf I AUG 12 W TOWN. OF E NISr,3URY BUi€AG & COrjr-s MAXIMUM LIQUID LEVEL INSTALL FLOAT SWITCHES TO OPERATE ALARM PANEL AT INDICATED LEVELS PRECAST CONCRETE EXTENSION TO GRADE WITH TRAFFIC RATED CAST IRON MANHOLE COVER WITH WATERTIGHT INSERT EXTERIOR WEATHERPROOF JUNCTION BOX (IF NECESSARY). SEAL CONDUIT GAS TIGHT. INSTALL CONTROL PANEL IN HOUSE 90% CAPACITY 80% CAPACITY (1,350 GAL) (1,200 (DAL) WARNING/SHUT DOWN 50% CAPACITY VERY HIGH LEVEL ALARM ON (750 GAL) ALARM ON HIGH LEVEL ALARM ON 1--1,500 GAL EXTRA HEAVY HOLDING TANK NOTES DUTY PRECAST CONCRETE ALL UNITS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEW YORK STATE HOLDING TANK DEPARTMENT OF HEALTH AND SHALL BE OF PRECAST CONCRETE AS MANUFACTURED BY FORT MILLER OR EQUIVALENT. ALL STRUCTURES SHALL BE PLACED ON FIRM, COMPACT SAND OR GRAVEL BASE. WHERE EXISTING SOIL CONDITIONS ARE UNSUITABLE, CRUSHED STONE SHALL BE PLACED AS NECESSARY TO ACHIEVE A STABLE BASE. TANK SHALL BE OF HEAVY-DUTY CONSTRUCTION DESIGNED FOR H-20 WHEEL LOADING. ALL JOINTS MUST BE SEALED WITH WATERTIGHT SEALANT LAST TANK NOT TO SCALE ALARM SEOUENCE ALARM PANEL TO BE CUSTOM ENGINEERED PANEL BY SJE-RHOMBUS® CONTROLS. INSTALLER TO OBTAIN SPECIFICATION FROM ENGINEER. WHEN LEVEL OF TANK REACHES 50% LEVEL, AMBER LIGHT WILL INDICATE "TANK HIGH LEVEL" ON ALARM PANEL. WHEN LEVEL OF TANK REACHES 80% LEVEL, RED LIGHT WILL INDICATED "VERY HIGH LEVEL" ON ALARM PANEL. WHEN LEVEL OF TANK REACHES 90% LEVEL, BUZZER WILL SOUND AND RED LIGHT WILL FLASH, INDICATING "TANK SHUTOFF LEVEL" AND RELAY FOR THE MAIN WATER SUPPLY WILL DISABLE PUMP, DISCONTINUING WATER SUPPLY TO HOUSE. SYSTEM WILL RESET AFTER HOLDING TANK IS PUMPED DOWN TO BELOW THE ACTUATION LEVEL OF "HIGH LEVEL" ALARM SWITCHES. / / / rr Q Z V O r r x 33 r / dGe of Pavement / r r / r r r r / Nailin Pavemen Found I , / x- 33 + I r 1 r 1 ' r / r RESERVED SPACE FOR PLANNING & ZONING RESOLUTIONS r / 1 IX V; 7 � / m � m A \ MAG Nail =o�,rd �' \ t m. r / Pavement �\ Concrei / m m LOT27 Lands Now or Formerly of L G. Leer, LW Book 3674 Page 128 2Z7.13-2-41 Lands Now or Formerly of Afetthew 1: and Aeanae D. Lumm Book 5005 Page 142 22T.18-2- 3 x 328,8 Stockad_ - e t'ence Remus �_, 1� _ _ __x 325.5 Steps Fence o Post - r l / / l X 324,3 i� / / / 1 - 48 ;Pine /j ------------ .' �� �/ Iron Pipes Found s o QD I i LOT 28 Area , = 0.21 t ;Acres )�`� i x 322.5 . . / r / x 326.2 Concrete , Stepp x 322.5 r Steps 0 Stone Retaining Wall P A i LAKE GEORGE f /`324 2 / / 25,4 // / i Wood Dock / / l ' x 323.9 ` N / 320.2= High water elevation per Lake George Park Commission Regulation 645-2.1(ak) GENERAL NOTES INFORMATION SHOWN ON THIS DRAWING IS TAKEN FROM A SURVEY DRAWING PREPARED BY DARRAH LAND SURVEYING LEGEND — — — — — — — — PROPERTY LINE ---------------------- PROPERTY LINE SETBACKS ---------- --- EXISTING CONTOURS 330 NEW CONTOURS E - E — E — E — OVERHEAD ELECTRIC SERVICE E/P EDGE OF PAVEMENT SITE DATA PROPERTY ZONING CLASSIFICATION: WR (WATERFRONT RESIDENTIAL) MINIMUM LOT SIZE: 2 ACRES MINIMUM LOT WIDTH: 150 FEET TAX MAP NUMBER: 227.13-2-42 SETBACKS FRONT REQUIRED 30'-0" EXISTING 17'-10" SHORELINE 50'-0" 28'-11" SIDE SOUTH 20'—O" 8'-5" SIDE NORTH 40'_1" REAR 30,-0" NA MAXIMUM BUILDING HEIGHT 28'-0" 24'-0"f MINIMUM PERCENT PERMEABLE 75X 62.21% MAXIMUM FLOOR AREA RATIO 22X 31.87X ACTUAL LOT SIZE: 9,225.38 SF (0.21 ACRES) ACTUAL FRONTAGE: 90.34 FEET EXISTING SITE COMPONENT TOTAL SITE COVERAGE CONDITIONS AREA 9,225.38 SF PERCENTAGE 100.0% BUILDINGS 1,432.21 SF 15.52X PAVING & WALKS 2,054.20 SF 22.27X GREEN SPACE 5,738.97 SF 62.21% BASEMENT SPACE 875 SF MAIN FLOOR 978 SF COVERED PATIO 403 SF ATTIC STORAGE 684 SF TOTAL 2,940 SF F.A.R. 31.87% FILE C�PY TOWN OF QUEENSBURY BUILDING DEPARTMENT Based on our limited examination, corm. PROJECT with our comments shall not be constr LOCATION indicating the plans and spec+fications are in full compliance 'try, 227.13-2-42 Sheehan, Joe 80 Rockhurst Rd Septic Variance/i TOWN OF QU • BUILDING & 0 - RevieWed By. Date, SEP-0614-2021 10 5 0 5 10 20 GRAPHIC SCALE 1. = 10'-0" u j AUG 0 9 7 � �'9'? SEAL BELOW IS AN ORIGINAL SEAL IS IN RED INK. ONLY SEALS IN RED INK SHALL BE CONSIDERED TRUE ORIGINALS P INo.1 DESCRIPTION DATE REVISIONS O W N N } Q N 3 W U } zk< U ==Z W Q- °4w W(75Z) = zU0 a�N 0a 0 Vi.. Q moo 3 J o Q Y O FL0 U. o. V OCRrt �'0 �az Ow0 o <w� ►. aZ ��- 5�Z Z Q m ooaoa Nro U xL ��� F_- a _j �X0 o O++ M OaE X W ti W WORK IS TO BE AS SHOWN & NOTED AND IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, TRADE ASSOCIATION PUBLISHED RECOMMENDATIONS AND GENERALLY ACCEPTED LOCAL CONSTRUCTION INDUSTRY PRACTICES. v V (V � C+0 O Cis c N o Q o . r..� 0 z Cd > o 00 W 4,) a CAD FILE NAME ACAD\SHEEHAN\C-1 SCALE AS NOTED DRAWN BY DRAWING TITLE EXISTING SITE PLAN DRAWING No. C-1 Y:\Slteehan Residence - Rockhurst\C-1.3 Concept Site Plan.dwg, 7/25/2022 9:42:10 AM, KIP 7170K Catch Basin Rim 337.5' 0 x ,316.0 x 337,9 / / r / / >>" LOT27 Lands Now or Formerly of L. G. LeWacr, LW Book J674 Page 128 227:1s-2-41 Utility Pole 33�'" �� Wood Fence Post / m 1 1 movement / / / 1 m / m O A 0 1 7 Q / --f CIO REVISION NOTE: / o TANKS UPDATED TO REFLECT / 1,500 GALLON 2—PIECE TANK FROM UTOPIA PRECAST / / 1500 GALLON 2 PIECE 1-58" W-6'1" L-9'2" TH-72" / r / OUTLET FROM HOUSE AND / Edge of CONNECTIONS BETWEEN TANKS / Pavement TO BE DETERMINED AT TIME OF INSTALL //PROPOSED / /HOLDING TANK SEPTIC SYSTEM (3) 1,500 GALLON HOLDING TANKS / Nail in / Pavemen / Found / x-33'r t r 1 I 1 I I 1 I A ' I A / I I ' I A I A MAG Nail Found / / / 1 / i; IrL�� 0 3 38 X in --N 79, 00. / --- 00" W 86. f I / r ." 1 , i I I Fence Post t 5 rn 1 U, a I ' I � / I � I t, I /x 331.4 i / isi;:::.....::.... •:•::•::... i..........:: fI'll t ::':r::::::•::•::: •..::..::.:....::::.• OF..... [:. i....::a:::::::::..:;:•::•::•:::::::::x:..: ..:...:..:::................................... 1,. I'll :. • :•..........:::: :...::::......... ....I.....i................................ •:.�.r�i•':..:........................................ . %....... r...:::.:.::::::.......:::.:::.:::.:. 1 I..::..... .... ?. .............. ' .:::.. ......,..::::: INV. 4" Drain 332.9' LOT34C Lands Now or Formerly of Afatthew 1: and Jeanne D. Lucas Book 5005 Page 142 287:19-2-1.Y SITE PLAN 1" = 10'-0" YAS6ehan Residence - Rockhurst\C-1.3 Concept Site Plan.dwg, 7/25/2022 8:45:22 AM, KIP 7170K SHADED AREA INDICATES EXISTING BUILDABLE AREA OF EXISTING LOT BASED ON ZONING SETBACKS 79-0c), 00" E ZT20".t Stock`Ce x 325.5 Steps Rem�^S __-- ----- --_mot Fence\ i 33(7. Post / 24-3 ------- Iron Pipes Found 00 i / , / i 1 / LOT 28 Area i = 0.,21 t Acres / ,• x 322,5 d/26,2 / I / 322.5 i 1 I I I i ti� Steps �A / Stone Retaining Wali P ,y LAKE GEORGE x,324. / /1 .9 Ole r r � � l 1 MJ r r 32D.2= High water elevation per La-e George Park Commission i 1 / Regulation 645-2.1(ok) GENERAL NOTES INFORMATION SHOWN ON THIS DRAWING IS TAKEN FROM A SURVEY DRAWING PREPARED BY DARRAH LAND SURVEYING LEGEND — - - - - - - — PROPERTY LINE ---------------------- PROPERTY LINE SETBACKS ----------- EXISTING CONTOURS 3 NEW CONTOURS — E — E — E — E — OVERHEAD ELECTRIC SERVICE E/P EDGE OF PAVEMENT SITE DATA PROPERTY ZONING CLASSIFICATION: WR (WATERFRONT RESIDENTIAL) MINIMUM LOT SIZE: 2 ACRES MINIMUM LOT WIDTH: 150 FEET TAX MAP NUMBER: 227.13-2-42 SETBACKS FRONT REQUIRED 30'-0" EXISTING 17'-10" PROPOSED 12'-3" SHORELINE 50'-0" 28'-11" 28'-11" SIDE SOUTH 20'-O" 8'-5" 8'-5" SIDE NORTH 40'-1" 10'-3" REAR 3V-0" NA NA MAXIMUM BUILDING HEIGHT 28'-0" 24'-0"t 24'-0"t MINIMUM PERCENT PERMEABLE 75% 62.21% 67.75% MAXIMUM FLOOR AREA RATIO 22% 32.99% 40.41% ACTUAL LOT SIZE: 9,225.38 SF (0.21 ACRES) ACTUAL FRONTAGE: 90.34 FEET 1NMI T TOTAL SITE 9,225.38 SF 100.0% BUILDINGS 2,500.00 SF 27.10% PAVING & WALKS 475.48 SF 5.15% GREEN SPACE PROPOSED FLOOR 6,249.90 SF AREA RATIO 67.75% COMPONENT BASEMENT SPACE 871 SF COVERED PA110 403 SF MAIN FLOOR 1,111 SF GARAGE 822 SF ATTIC STORAGE 330 SF COVERED DECK 129 SF COVERED PORCH TOTAL SPACES 3728 SF F.A.R. 40.41 % VIMA IC^T 227.13-2-42 SEP-0614-2021 Sheehan, Joe 80 Roc:khurst Rd Septic Variance/Alteration 10 5 0 5 10 20 GRAPHIC SCALE 1" = 10'-0" AUG 0 9 2�� _ I' 1� 1 �r �r THE SEAL BELOW IS AN ORIGINAL SEAL AND IS IN RED INK. ONLY SEALS IN RED INK SHALL BE CONSIDERED TRUE ORIGINALS 0 IREVISED TANKS 25 JULY 22 No. DESCRIPTION I DATE REVISIONS 0 W N 0 N Q 3 U (� W ZW< r U==Z W a °o2 F- 0. = zZ�� V < N n/ LL a o 3:z0 3 JOZ Y W W t= C Z 00 00 a Z W O (0� cZ t�l�o S�< Z Q m ao ao a N F U �. X� ��� �QQ Dov am— C .O o C t 2 X I- x'W -0 >LTW WORK IS TO BE AS SHOWN & NOTED AND IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, TRADE ASSOCIATION PUBLISHED RECOMMENDATIONS AND GENERALLY ACCEPTED LOCAL CONSTRUCTION INDUSTRY PRACTICES. U O 00 O -�-� � O O o z CIS > O 94 0 4� a CAD FILE NAME ACAD\SHEEHAN\C-1 SCALE AS NOTED DRAWN BY DRAWING TITLE PROPOSED SITE PLAN DRAWING No. C— 2 Z of RESOLUTION APPROVING MARY E. SHEEHAN IRREV. TRUST'S APPLICATION FOR SANITARY SEWAGE DISPOSAL VARIANCES RESOLUTION NO.: BOH 56,2021 INTRODUCED BY: Mr.Harrison Freer E WHO MOVED ITS ADOPTION AUG Q 9 2022 SECONDED BY: Mr. George Ferone TOWN OF OUEENSBURY BUILDING & CODES WHEREAS,the Mary E. Sheehan Irrev. Trust(Applicant) filed an application for variances from provisions of the Town of Queensbury On-Site Sewage Disposal Ordinance, Chapter 136, §136-11 which requires applicants to obtain a variance for holding tanks as the Applicant wishes to replace a wastewater system by installing a holding tank system consisting of three (3) holding tanks each with a capacity of 1,500 gallons for a total capacity of 4,500 gallons, thus meeting or exceeding the required total capacity of 3,000 gallons,and WHEREAS, the Applicant has also applied for additional variances from Chapter 136 to allow placement of the holding tanks: 1. 4' from the existing home in lieu of the required 10' setback; 2. 5' from the south property line in lieu of the required 10' setback; and 3. 4'8"from the west property line in lieu of the required 10' setback; on property located at 80 Rockhurst Road in the Town of Queensbury, and WHEREAS,the Town Clerk's Office published the Notice of Public Hearing in the Town's official newspaper and the Local Board of Health duly conducted a public hearing concerning the variance requests on Monday, September 27th,2021, and WHEREAS, the Town Clerk's Office has advised that it duly notified all property owners within 500 feet of the subject property, NOW,THEREFORE,BE IT RESOLVED,that 1. due to the nature of the variances, the Local Board of Health determines that the variances would not be materially detrimental to the purposes and objectives of this Ordinance or other adjoining properties nor otherwise conflict with the purpose and objectives of any Town plan or policy; and 2. the Local Board of Health finds that the granting of the variances is necessary for the reasonable use of the land and are the minimum variances which would alleviate the specific unnecessary hardship found by the Local Board of Health to affect the Applicant; and BE IT FURTHER, RESOLVED,that the Local Board of Health hereby approves the application of the Mary E. Sheehan Irrev. Trust for variances from the Sewage Disposal Ordinance to allow installation of a holding tank system consisting of three(3)holding tanks each with a capacity of 1,500 gallons for a total capacity of 4,500 gallons, thus meeting or exceeding the required total capacity of 3,000 gallons and placement of the holding tanks: 1. 4' from the existing home in lieu of the required 10' setback; 2. 5' from the south property line in lieu of the required 10' setback; and 3. 4'8"from the west property line in lieu of the required 10' setback; on property located at 80 Rockhurst Road in the Town of Queensbury and bearing Tax Map No: 227.13-2-42,and BE IT FURTHER, RESOLVED, that the Town Board authorizes and directs the Town Clerk to forward by certified mail a certified copy of this Resolution to the Adirondack Park Agency for its review,and BE IT FURTHER, RESOLVED, that this approval Resolution shall not be effective until 30 days after such notice to the Adirondack Park Agency and shall be subject to review by the Adirondack Park Agency during such period. Duly adopted this 27th day of September,2021,by the following vote: AYES : Mr. Ferone,Mr. McNulty,Mr. Metivier,Mr. Freer NOES : None ABSENT: Mr. Strough .• . ...„...,................._...„,, ! .ozeizJaqulaa•aa pasyka)f Lioge311.dilvapdas .•L.'i..- ' -.: .:.::::: .:•-•::-•.E:••••:..': --:•--Z.:.';''. .- : --1: :- .::: . - .. .......... .....:. , ......- ..... .. .i..,: . - •- ---• . •--:-- :•:-•• :--:.-:,-.-:'.:-:.:-:':::];.--?-•'.. :.•, .__--1 :::-.'••..._.;. '"- : .-.::,-•-• - . .--, ,'::; ''._. ... ..:.::::1' .. - '• , : . -1._ .• -:'. i-----:-.:._ ... -.1-: : .:*:;: sNueljo # '- -oasi -.azi.5.)iy ?..,. oo.51b-z/oped0o pai!nbaa leloi 1tiO4sA5.-muei u!PICs,:H : :-:' : -• :adA -J-at.ilojo paa• u.4pisAs engeu.,,keilv •..1•Gzis f :A0etu..m0H au01:5:Ettpy 1.14.a2..pcfp: s..- ... . . . . .i., .1!• • If. —- -''''' .. LIDP- il: pe f'.14. . :tilFuOi 110.1. .u(31•5.WMPlal4:upii4i.O.stfv: :::'-wpl.s4S-- .. . criIOLVecis : - . ,• .::• - 104ppollA)..00.0.04.:0 ..coopj.0,i:§.1,10.ijeB os ppe tuoileD 00n azIs 7•Liliu) :suolieS • -02!s.mt.ie±.. '..: :•NoLvdMiadm itklusAsi.0150dMid- •• - - - • _ ._ - - -- - 1 •• (pamtpiapaayOuR pat.0311: e-,.Act-poid.w03-ocii-o44$61) tpUri0.d 01nOlt,u...4ac1 :0401 .1.5aiupp.seioalait. (11. s!-uogd)osqe•Lpp.4, 6 igdOs..4ye 1.004-44.1110t.is-.41.6AA.10el JO Rpm JO : 9)10.7- .tiom7 ledpluh.v\i— .:- AlcIdn's Jel. M.?!lse,tiioa zy.dop..104nAlv• - iepaleurtliO!krclu1171)o)p _!: ,a0d.a.0:1.0-tiivi-4v..,. .-.-- jterlApti.bO.t6:-•s-: -::i p - ,:j. • (litidx. .--.1301.13,0 " _AelD." .weoi — pges .a-41.?1P.N•119Sil . , i!; - 'Odo.is:% .. •aldoiS'dealS .21-11110.N 1:eld .-, . Aqc1046001:1- 111.19.11ViNklOJW713N,ifet . p.tao.-- p (34,:t:Opitoliur:• : _ 55 Orr. : 11.1?5?id-z66T .. ! ON 5.aA , girilijoH.jO:Ods... On . .-I661-.'1961• ,: ::: .... -- A , (p,go...ap.qp.)-:-.:zp.qiip4.sw o ., -. Oil - OST., JP194.Q.:06T 'ON .1pufi ?e.qj. 0 i uibbipatf . :Ap.-J?d, - • - r• •-'i , 11.49.14AIIPPI.e101,= 'i' .IP0 suCtile2)( ,:s050.11),01146.4 . suolie9. ...mni4:1.-.1.VA - • .::: 1 NPIIVVII.U0JNV33:N3_01S34.i A .P10715:3:65i\13- 413n0 -187.4171/18 ' . ezez 60 911V 1 • , • • • • 7• -2- 1 L7_2 #d41)(q 0a, 33 j ug - +1,1151,oy 0 S 1U011,e30113p104d . Z069 t,Gca 0-A44\AVA . IN - N0.11V3IlddV:11 lAttlad.1VSOdS1001Id3S: • . .- . . A. .: 4Pz pc0.01J ... ...? .- v;),z :#a3ponui . lat!':-/f4trist,laanbwimm,i.9sz8.tptirt s-:4-: t7.08rf:AN eit,iticpu6pritji!O.ePtiit,gt zti4:: ..:•::, ' - -- - .. - .:aed Ituilaa i: • - • it oz, „ AA .... .:. .:.:,,:.,. : . .. Atuaasn aa410, :-.: :': - ‘74*1'• -: is -•:' !:il , • .4):'0)64.4,4 ' . •••-• • '-'1:.-:".'1.::1 '.:. . ------ *.-..:- . : • ::i,. ,:-..-:-::.:-, ... ,-•.."'.:-.!..,_; :.,,,;: CONTACT:INFORMATION: PLEASE PRINT LEGIBLY OR:TYPE,EPLEASE INCLUDE AN EMAIL • Applicant:: Name(S)..... . 1 16 5 Scrkc t Cret;.h Mailing Address, C/S/Z: Z Cowey lvetyreh ': I- otf Y W i• i-z7ey :Cell:Phone:_( si S ): 7 6,- 0 85.6 Land Line _( riq ) 714- 7/9 y Email 51,11'ele-1 0 ; 104ce,#•c • Co"- : .: ?rimeni Ownet(s): 7 Name(s) 6i.... 5-11e-e LI.— Mailing Address-X/5/Z:: qe, , ,,c. k 11,,,lt Rovii. ee Y. wk 12 So ti Cell liligneU '1,1 ) 165 - r 6C & Land Line! Email: DI Check if all work will be performed by.pi...OpertViOMeronlv • Contiettor: :: Contact Name(s): ContraCtor:Trade: Mailing AddreSs,.C/5/Z; ,. . Cell PhOne:_( ): Land Line: _-_( ) Email: **Workers' Comp documentation,must be submitted with thig.:aorilitation:**. 0 'Engineer(s)! z] Name(s) : 14,-(in 5 ki* 14 c I( 11,- c 4 t-eovv-e .. . MailingAddress, C/S/Z: 134 0'x 4v-e ( leo 5 Frcilf tY(f 17 So 1 I . Cell Phone:j ) Land Line: A siq !) 7 1117 02- Ertiail: „ Contact Person for Compliance in regards to this project 52-0€ r5 ilrerkk 1-1 . ice,o-tt.' Cell:Ph One: 1 g4-1- -/-ii-?--C6--C-(9 Land Line'.' ( ) z,z f.,. Etti8ii:. NOTES: 1. Alarm system and associated electrical work must be:inspect0:by a Town approved electrical kl inspection agency,?-. We will no longer allow systems to be covered:until:-such tirne:as;ah as-built plan is receiVed,and;approved. The installed system must match the septic layout on file—no exceptions 3.:As- .: built:drawings must be submitted prior to the inspection, if there has been a change to H plans,4. If, for any reason, the building permit application is withdrawn,:30 of the fees retainecl.by the .. . „ TOwn:of Queensbury. After i year from the initial application date. 100%of the feels'retained:. ::Decidration::Apy permit:or approval granted which is based upon or istranted.:iin;reliance.upon anvmaterial representation or failure tO make a material fact or circumstance knoWhibNicOr on:behalf Of an applicant,shall be void:I have read the regulations and agree to abide by these and-all requirements of theTOWn:of queenSbury Sanitary Sewage Disposal Ordinance. : E :PRINT:NME : r.%'(-- S"A;0 ire y A SIGNATURE: ::: ' q/...: Q: : .i ": ' ' :: :: ':':' !::::: : -::: DATE -0.1/%1/Z01Z.?.. • :: i : . ,'', 1 ,6, .' ' : :: .' ''' ' • '''': :: • :: . ' etttieApplieation .Revised.December 2020 ::. 11111111144 TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY. 12804-5902 Septic System Checklist '6 Plan to scale Received Deep hole perc test results from engineer/Architect if applicable(Town Approved Engineers and Architects;June 30 to April 15 Town Engineer for unapproved Engineers and Architects) N All wells on property and adjacent properties shown k,,Q � �.N—c Water line shown Municipal or well 10'separation to any part of system VSetback to property lines show 10'or more for any part of system \(Septic tank and pump stations 10'from foundation 50'from any well/lake/wetland 10'from any waterline Septic tank to foundation crawl space/slab on grade,grade in crawl space must be above top of septic tank for 0',Separation required (field verification required) Septic tank sized or nunlber of bedroom and add 250 gals for Jacuzzi tubs/garbage grinder each Leech Field 20'from foundation 100'from any well 10'from water line %keepage pit 150'from well 50'from septic tank Seepage Pits 3-times diameter apart Y. Septic tank and pump stations over 30 gallons 50'from watercourse or wetland distance from bottom of trench or system 24"to bedrock or mottling 36"within 1000' of Lake George i)ikLeech field 100'from watercourse or wetland 4-Toe of mound or bottom of retaining wall 10'from property line 100'from well 20'from Foundation Provide Engineer/Architect stamp for bed or design systems .0 Department of Health Approval for all mobile home park new systems Flood Plain requirements b 2' above established flood elevation to bottom of system Off Q 10 All tanks anchored or 2' above flood elevation dSs\Z'- RESERVED SPACE FOR PLANNING & ZONING RESOLUTIONS Lor9 Londs Now - Fwm /y of L L & Ly cy, Wood Frame Residence Catch Basin Book 3614 Pogo 12B Rim .1.5' / PB7.19-P-dl /!jt,JY /ry " m37 Wood Fence Post '1 0_ _ ' . 33T.5 Post' �$1 +G, _ _ MAG Nail Found //[,(y'�am ^_ E(jLJI .338.1 f � O S� / Slep$` Fence Thresh Id / ;�Cha'n m Between Lamps $i:WA�2 9 x y y 2 / iy /may Ir !/ f ✓r Blaue P-1 M ke WooN�F vCt1! Res / / 33 .6 F' reshold 331.5' 330.9 Pavement / 2" Oe / / ith Cap IP REPUTED <_ SEPTIC SYSTEW7 -- wood D.ok Edgei coneo1. LOCATION /m Chimney, --------- / - Nail in Pavement ` m Pavemen Concrete Found r�_ N 00. IN22e.13-2-42 SEP-0614-2021 _- �9• DO' _ Mary E Sheehan Irrevocable Trust 336.6 I r �_- 80 Rockhurst Rd Septic Variance/Alteration SITE PLAN �I SHADED AREA INDICATES EXIING BUILDABLE OON ZON NIN GGSLOT ETBAC S BASED II 79 �`00. E Stonk�6 doh e ReFs =_ --�___ - x 325.5 Steps / y�y 48"f�'ne x 324.3 Post Iron Pipes Fountl LOT k8 Areal-0?12 7 / x 3f26.2 r< iete f / 5tepk f u / x 3225 / Wood Dock x 323.9 / /,/�320.2= High water elevation per / / Lake George Park Commission f / Regulation 645-2.1(ok) Drain 332.9' LOTMC L—Nox-F 'of Yett - X and J D. LHaee Book 50 Peg, 142 PSP:1B-8-AY LAKE GEORGE GENERAL NOTES INFORMATION SHOWN ON THIS DRAWING IS TAKEN FROM A SURVEY DRAWING PREPARED BY DARRAH LAND SURVEYING LEGEND ---�- --- PROPERTY LINE - ------ PROPERTY LINE SETBACKS ---------- 330---------- EXISTING CONTOURS 33D NEW CONTOURS —` —` —' —F — OVERHEAD ELECTRIC SERVICE E/P EDGE OF PAVEMENT SITE DATA PROPERTY ZONING CLASSIFICATION: WR (WATERFRONT RESIDENTIAL) MINIMUM LOT SIZE: 2 ACRES MINIMUM LOT WIDTH: 150 FEET TAX MAP NUMBER: 227.13-2-42 SETBACKS R O IR D XI TIN FRONT SHORELINE SD'-0' 28'-11' SIDE (SOUTH) 20'-0' W-5' SIDE (NORTH) 40'-l' REAR 30'-0' NA MAXIMUM BUILDING HEIGHT 28'-0" 24'-0'* MINIMUM PERCENT PERMEABLE 75% 6221% MAXIMUM FLOOR AREA RATIO 22% 31.87X ACTUAL LOT SIZE: 9,225.38 SF (0.21 ACRES) ACTUAL FRONTAGE: 90.34 FEET EXISTING 61 F COVERAGECONDITIONS COMPONENT AREA PERCENTAGE TOTAL SITE 9.225.38 SF 100.0% BUILDINGS 1,432,21 SF 15.52X PAVING & WALKS 2,054.20 SF 22.27X GREEN SPACE 5,73B.97 SF 62.21X EXITING FLOOR AREA RATIO COMPONENT BASEMENT SPACE B75 SF MAIN FLOOR 978 SF COVERED PATIO 403 SF ATTIC STORAGE 684 SF TOTAL 2,940 SF F.A.R. 31.87% LOCATION Kattsk8i Bay TROUT 'd'. don PAVILION^--'.. C iaverdale Foin AD IN'XEYRD �+7 0 +�Hoofing Pag Ffnuna Wr/ PL � Rocl'htrrE A PO' FIELDING FJII•E o FE449?C LA }'' NCKOKJI NKiONPi .' YVhtiYr',FLDS LARfSACRf qn � 7 / HFRONN0004RD s I. CAYUGA DR FISIIN H. ONBDA DR a ROLE 3. KOUDAYPOINT RD AWE � 6 Nuun11 Ra Axwu oii i" i 2 M S. CONSRTIRXYNWY ~4ppt80U54 RP' 1,TD9CARORAOR , eOATNDt5E DR �. E:ON0111DA6A OR 1Df * ...:: _� i BRA YEONRO- 10 5 0 5 10 20 GRAPHIC SCALE THE SEAL BELOW IS AN ORIGINAL SEAL AND IS IN RED INK, ONLY SEALS IN RED INK SHALL SE CONSIDERED TRUE ORIGINALS REVISIONS C. F- _< w gzi3 o _ z Yes gz a� 50� Zia a'� Fk - E WORK IS TO BE AS SHOWN & NOTED AND IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, TRADE ASSOCIATION PUBLISHED RECOMMENDATIONS AND GENERALLY ACCEPTED LOCAL CONSTRUCTION INDUSTRY PRACTICES. U � � N p a _O O N 9 O � 00 01 V L LAD FILE NAME ACAD\SHEEHAN\C-1 scALE AS NOTED DRAWN BY DRAWING MILE EXISTING SITE PLAN DRAWING No. C-1 x 33],9 /I / Catch Basin / Rim 337.5' x 1338,0 ,7 Utility Pole 33 i -�-_ / AG Noil Found / / x I 338.1 rJ�10. m , Im x / V oO �l / 4 -g• x 337.8 n x 33 j Edge of Pavement PROPOSED /HOLDING TANK SEPTIC SYSTEM (3) 1,500 GALLON HOLDING TANKS / Nail in ,- Found11 / J •i __ -�F_'C 1 I I 1V I IX 336.6 ' I LOY9 Lantls Now w Fwmer/y of L G 1 pq, LiC Wood From, Residence Book 3674 Pog, 128 227.13-2- 1 7 =± Wood Fence Post 337,5 a 33 O E Post 331.4 .III x K1cT11C1 SHADED AREA INDICATES EXISTING BUILDABLE AREA OF EXISTING LOT BASED ON ZONING SETBACKS x 328.8 x 325.5 frf%/ r rX322.5/f i vPsteps ' LAKE GEORGE r325.4 11 Wood Dock i 323.9 N ,Hybx� '.ir328:R' - f 320.2Z High water elevation per Lake George Park Commission Regulation 645-2.1(ok) INV. 4" Drain 332.9' 2g �» LOT34C Longs Now or F eNy of v tt8ew L mod A.- A Laces Dock Bs,k 5805 Pay, 142 227.19-P-F9 SITE PLAN 1- " 10'-D" GENERAL NOTES INFORMATION SHOWN ON THIS DRAWING IS TAKEN FROM A SURVEY DRAWING ON BY DARRAH LAND SURVEYING LEGEND ---------- PROPERTY LINE -`------------------ PROPERTY LINE SETBACKS ---------- 330---------- EXISTING CONTOURS 330 NEW CONTOURS —` —e — —e — OVERHEAD ELECTRIC SERVICE E/P EDGE OF PAVEMENT SITE DATA PROPERTY ZONING CLASSIFICATION: WR (WATERFRONT RESIDENTIAL) MINIMUM LOT SIZE: 2 ACRES MINIMUM LOT WIDTH: 150 FEET TAX MAP NUMBER: 227.13-2-42 FROSETBACKS R O IR D EXISTING PROPOC p SHORELINE 30'-0" 17'-10" 1Y-3" SIDE (SOUTH) 50'-0' 28'-11' 28'-11" SIDE (NORTH) 2D'-O" B'-5' B'-5" REAR 40'-1" 10'-3" 30,-0' NA NA MAXIMUM BUILDING HEIGHT 28'-0" 24'-0"t 24'-0"t MINIMUM PERCENT PERMEABLE 75X 62.21X 67.75% MAXIMUM FLOOR AREA RATIO 22% 32.99% 40.41% ACTUAL LOT SIZE: 9,225.3E SF (0.21 ACRES) ACTUAL FRONTAGE: 90.34 FEET PROPOSED SITE COVERAGECONDITIONS COMPONENT AffB PFRCFNTAGF TOTAL SITE 9.225.38 SF 10D.0% BUILDINGS 2,500.00 SF 27.10% PAVING & WALKS 475.48 SF 5,157 GREEN SPACE 6.249.90 SF 67.75% PROPOSED FLOOR AREA RATIO COMPONENT BASEMENT SPACE 871 SF COVERED PATIO 403 SF MAIN FLOOR 1.111 SF GARAGE 822 SF ATTIC STORAGE 330 SF COVERED DECK 129 SF COVERED PORCH 62 SF TOTAL SPACES 3728 SF F.A.R. 40.41X 10 5 0 5 10 20 GRAPHIC SCALE THE SEAL BELOW 18 AN ORIGINAL SEAL AND IS IN RED INK. ONLY SEALS IN RED INK SHALL BE CONSIDERED TRUE ORIGINALS REVISIONS LLJ jC w 6o Qo�� �= oa Yai $i Sok-' Z¢a <D oW MA > w WORK IS TO BE AS SHOWN & NOTED AND IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, TRADE ASSOCIATION PUBLISHED RECOMMENDATIONS AND GENERALLY ACCEPTED LOCAL CONSTRUCTION INDUSTRY PRACTICES. U O o � 3 O' CAD FILE NAIAE ACAD\.EEHA14\C-1 SCALE AS NOTED DRAWN By DRAWING TITLE PROPOSED SITE PLAN DRAWING No. C-2 M U L U f6 GENERAL NOTES 0- INFORMATION SHOWN ON THIS DRAWING IS TAKEN FROM 2 A SURVEY DRAWING PREPARED BY DARRAH LAND SURVEYING rn 1P LO LEGEND LP CN N CD - - - - - - PROPERTY LINE PROPERTY LINE SETBACKS AS-BUILT CONDITIONS 5 JAN 2024 0 REVISED TANKS 25 JULY 22 3 ----------330---------- EXISTING CONTOURS No. DESCRIPTION DATE 330 NEW CONTOURS REVISIONS E E E E OVERHEAD ELECTRIC SERVICE O U E/P EDGE OF PAVEMENT W N 0 L.L CDa U Q M Z) N U } SITE DATA z � Q U DLU � z Uj PROPERTY ZONING CLASSIFICATION: WR (WATERFRONT RESIDENTIAL) � o MINIMUM LOT SIZE. 2 ACRESUj — z MINIMUM LOT WIDTH: 150 FEET 2 z U e U aJ � U TAX MAP NUMBER: 227.13-2-42 Q � zo z (U a SETBACKS REQUIRED EXISTING PROPOSED J ' o c FRONT 30'-0" 17'-10" 12'-3" J o � � o C SHORELINE 50'-0" 28'-11" 28'-11" Q c L U SIDE (SOUTH) 20'-0" 8'-5" 8'-5" _ 00 E; L'j Of CN SIDE (NORTH) 40'-1" 10'-3" _ - o o � � REAR 30�-0�� NA DNA Y v = 2D -02 r MAXIMUM BUILDING HEIGHT 28 -0 24 -0 t 24 -0 f (n L � z r r- > > z MINIMUM PERCENT PERMEABLE 75% 62.21% 67.75% z 0 _" > V) m co� Q z of MAXIMUM FLOOR AREA RATIO 22% 32.99% 40.41% Q 6 L � U / ACTUAL LOT SIZE: 9,225.38 SF (0.21 ACRES) ° c E) U x 0 x 337 9 ACTUAL FRONTAGE: 90.34 FEET w 5 >L� w / PROPOSED SITE COVERAGE CONDITIONS / COMPONENT AREA PERCENTAGE WORK IS TO BE AS SHOWN & NOTED AND IN ACCORDANCE / LOT27 WITH MANUFACTURER'S Lands Now or Formerly of TOTAL SITE 9,225.38 SF 100.0% RECOMMENDATIONS, TRADE BUILDINGS 2,500.00 SF 27.10% ASSOCIATION PUBLISHED L. G. Legacy, LLC Wood Frame Residence PAVING & WALKS 475.48 SF 5.15% / GREEN SPACE 6,249.90 SF 67.75% RECOMMENDATIONS AND Catch Basin / Book 3674 Page 12e GENERALLY ACCEPTED LOCAL CONSTRUCTION INDUSTRY Rim 337.5' i 227.13-2-41 PROPOSED FLOOR AREA RATIO PRACTICES. / SHADED AREA INDICATES COMPONENT BASEMENT SPACE 871 SF � 80 OFSEXI EXISTING LOT BASED COVERED PATIO 403 SF Utility Pole ��� - _ ON ZONING SETBACKS MAIN FLOOR 1,111 SF mx 337� _ GARAGE 822 SF Wood Fence Post E3-= COVATTERED REDO DECK 129 SF m - --�_ COVERED PORCH 62 SF -Fence ° 79' Qp'-� TOTAL SPACES 3728 SF _ 337 5 Post 5L �� ,� - E �� - _ w _ 0 f x 328 8 �� CO ✓� F.A.R. 40.41% MAG Nail Found m �� ✓_ ' �'�_____- - - �� b✓ ` ✓ Stackode nce Re7 - _ ��_ _ x 325 5 Steps OQ N 4i � i ✓ Fence � / �ovement✓ �i i ix 3314 ` 0 �I x 3306 i i� Post ,� 0 Q m i _----- I���r-i x 324 3 �� __ � �� � Iron Pipes Found x 3381 ' I ? o ✓'- i -� PROJECT LOCATION F l F 1; ✓ l l / / �� i m ✓ / �: i✓ l I CO Area = 0.121 f iAcres S, 0 � �7'�lo. x 338� ` ���r+ + � x' �� ' Kett s,ic l B ' " _ m i 1�11 ✓✓ I ✓ �� �I �� ,i 03 00 x 322,5 , �� / TiI[U� 1 I 1 — � x 126,2 i� i �� iRD p - 33 i iu� L r 7 Cy res R , m i i r i dh s t , x 322 5 ,,,,, ,, 'IGwnn k �rs�W REVISION NOTE: 0 moo, ��, m i / ' '' ��,, r H LMIN Pf,' Put TANKS UPDATED TO REFLECT ® ®_ i �� , Steps , 1,500 GALLON 2-PIECE TANK � 4'-8" ' � - ;_-_- -- ' ' ' � � �'AGL r FROM UTOPIA PRECAST x 3379 � �� Stone Reta ring Wall ,' ��� P�01 �� x W iHICKDko 1500 GALLON 2 PIECE x 33 ; ��� ' °� rr LAKE GEORGE rr 1=58 W=6 1 L=9 2 TH=72 x 330 9 �� r j r r_ - x A24�2 OUTLET FROM HOUSE AND Edge of ,3', oo � i; � i CONNECTIONS BETWEEN TANKS Pavement o _ TO BE DETERMINED AT TIME OF I _� �'� �� i �' IYIHf 1 V,' INSTALL /PROPOSED / l i 0 325 4 �� i % i Wood Dock >; ,,,,,, n F: o / HEREON LLON' 1� � E HOLDING TANK �_ � , � , � , ; SEPTIC SYSTEM / EID D �, L �0 ��� , ULIDAY POINT RD (3) 1,500 GALLON C` HOLDING TANKS m 20' �.. -- -_ �� ' w ff Nail in �2" i 4' EE x 323�9 ✓'✓� ! '� � 1l r 4 0 OR Pavemen m �� o o .T BOAT ROUSE 3.0,N,,,0NDAGA DR Found ---- -- — �� 79. OG � -- 001, o �aI 0 --�_ _ �/ i�86'f ��� - �� i�� �L � Wire Fence-- x-� � 3-L'64 - S2L � 320.2= High water elevation per m � —�_ �� �i ✓� i Lake George Park Commission CAD FILE NAME Regulation 645-2.1(ak) ACAD\SHEEHAN\C-1 mx 336 6 I - ✓ x 323 5 � � � SCALE AS NOTED IINV. 4" �-- I m i Drain 332.9' 28 THE SEAL BELOW IS AN ORIGINAL SEAL DRAWN BY AND IS IN RED INK. ONLY SEALS IN RED INK SHALL BE CONSIDERED TRUE ORIGINALS LOT34C DRAWING TITLE I I I Lands Now or Formerly of m Matthew K. and Jeanne D. Lucas Dock Matthew rya xay'Mi�%d g'� 1� '� ° � �V PROPOSED Q I I Book 5005 Page 142 �F i,"�,r�'�,c�Vx I� �n7 �`Y ��' � SITE PLAN 1011, I 227.13-2-43 10 5 0 5 10 20 /� dL m 107 i hin � p'.' Ir a%'1 �"�I�" (PSpm iur �l ifrt GRAPHIC SCALE DRAWING No. SITE PLAN 1" = 1O$_0Pl C- 2 ill = 10'-0"