Loading...
CC-0149-2022 i I Office Use Only f 1 ik PRINCIPLE STRUCTURE PERMIT APPLICATION Permit#: C'L' ^ Daft - 2.022— Permit Fee:$ '� � J<85 Town of CZuccnsbury ` 742 Bay Road,Queensbury, NY 12804 *Rec Fee:$ pY'QN• - Y� P: 518-761-8256 www.queensburynet Invoice#: Flood Zone? Y N Reviewed By:IMSi_ Project Location: S-1 Vim/ ,(S ,� , I/Q� wbi,- NV ( 2f 0 q Tax Map #: 7 . b - d. Subdivision Name: *TOWN BD.RESOLUTION 385-2020:$1000 recreation fee for new dwelling units:single family,duplexes/two-family, multiplefamily, apartments,condominiums, townhouses,and/or manufactured & modular homes,but not mobile homes. This is in addition to the permit fee(s). PROJECT INFORMATION: X, Residential Commercial, Proposed Use: 2. C. Single-Family: _Two-Family O Multi-Family(#of units: 1/4) ) 1. Custom 2. _Modular(REQUIRED:NYS stamped engineered drawings of foundation plans) Townhouse Garage (#of cars ) _ Business Office Retail Hotel/Motel Industrial Heated Warehouse/Storage Building Unheated Warehouse/Storage Building Amusement Ride Other (describe: MAIN STRUCTURE SQUARE FOOTAGE: GARAGE-SQUARE FOOTAGE: 1ST floor` 16) 0cEavE0 1ST floor: / 3 I D 2nd f100 I Atm n 2nd floor: Gr U I [ „"% u ZI�z/ 3rd floor:_ Total squarielfeet:,d Basement(habitable space): - COOS Total square feet: Princiole Structure Packet Revised August 2021 e i ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ 7(0)OD O C/P 2. Proposed use of the building: Qzrt- .1. 3. 'If Commercial or Industrial, indicate the name of the business: 4. Source of Heat: _Gas _Oil 'U Propane Solar _Other: (Fireplaces need a separate Fuel Burning Appliances & Chimney Application, one per appliance) 5. Are there any structures not shown on the plot plan? YES )C NO Explain, if yes: 6. Are there any easements on the property? YES x NO 7. SITE INFORMATION: a. What is the dimensions or acreage of the parcel? 0 • 33 b. Is this a corner lot? _YES )( NO c. Will the grade be changed as a result of the construction? YES )C NO d. What is the water source? )( .PUBLIC _PRIVATE _WELL e. What type of wastewater system is on the parcel? SEWER )0 PRIVATE SEPTIC DECLARATION: 1. I acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans, additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn, 30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100%of the fee is retained. 3. I certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a NYSlicensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: sera el e--0 SS' SIGNATURE: Jfn,— DATE: Q ILI I 1:1" /P Principle Structure Packet Revised August 2021 1' CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): J t?r,-yl sSS Mailing Address, C/S/Z: j Car ►( � - , I cut, , /iWffct, Cell Phone: ( ) — b-7 c, Land Line: ( - ) Email: ) OSs(cartS+rur' t',r,lD� y v'a 11 . Co',i • Primary Owner(s): Name(s): Mailing Address, C/S/Z: Cell Phone: ( ) Land Line: ( Email: dieck if all work will be performed by property owner only • Contractor(s): (List all additional contractors on the back of this form) Contractor Name(s): Contractor Trade: Mailing Address, C/S/Z: Cell Phone: ( ) Land Line: ( ) Email: **Workers' Comp documentation must be submitted with this application** • Architect(s)/Enqineer(s): Business Name: Contact Name(s): ?e-Fter - Mailing Address, C/S/Z: 17 ct1e5+ Roc, ci 5w-11(N C1 Lp v) ( LS , NY 124 OS Cell Phone: ( ) Land Line: (5/ ) 9 Email: Contact Person for Compliance in regards to this project: Cell Phone:_ ( 51°v ) l0 ( — 01(2 c Land Line: ( Email: jrns5 Gin S te.-h-b,- ( I C0 j rvi at I • eV,n-t Principle Structure Packet Revised January 2021 CHECKLIST--SINGLE FAMILY Project Location: REQUIRED—3SETS 1. Building Permit application, completed YES NO N/A 2. Energy Code inspector's report from ResCheck, completed &signed 3. Septic alteration application, if applicable 4. Solid fuel burning or gas insert appliance form(s), if applicable 5. Driveway permit, if applicable 6. Structural drawings (3 SETS), including: a. Floor plans b. Foundation plans c. Cross sections d. Elevations e. Window& door schedule f. Natural light,ventilation & emergency egress 7. Plot plan: showing proposed structure(s) with setback dimensions from all surveyed property lines 8. Electrical inspection agency selected 9. Manual S &J 10. HRV or ERV 11. Kitchen Hood specs, if necessary CHECKLIST-- MULTI-DWELLING/COMMERCIAL Project Location: ?,�� � Sb�n �, /(Y REQUIRED-2 SETS 1. Building Permit application, completed YES NO N/A 2. Energy Code inspector's report from ComCheck, completed &signed 3. Septic alteration application, if applicable �Q 4. Solid fuel burning or gas insert appliance form(s), if applicable 5. Driveway permit, if applicable >D 6. Structural drawings, including: a. Floor plans b. Foundation plans c. Cross sections d. Elevations e. Design loads including floor, snow&wind load f. Seismic design g. Plans signed and sealed by registered architect or engineer h. Window& door schedule 7. Plot plan: showing proposed structure(s) with setback dimensions from all }� surveyed property lines 8. Electrical inspection agency selected 9. FINAL AS-BUILT PLANS SUBMITTED ELECTRONICALLY Principle Structure Packet Revised January 2021 IOW FIRE MARSHAL'S OFFICE. w_ 1 Town of Queensbury 742 Queensbury, ,Road Bay uri, NY 12804 "Home of Natural Beauty ... A Good Place to Live " PLAN REVIEW Jered Ross 375 Queensbury Avenue CC- 0149-2022 4/8/2022 The following comments are based on a review of submittals: /41 • Verify smoke detector locations and function • Verify carbon monoxide locations and function • Verify egress components • Very Truss ID installation • Verify integrity of fire walls 14\c4 Michael J Palmer Fire Marshal 742 Bay Road Queensbury NY 12804 firemarshal@queensbury.net Fire Marshal 's Office • Phone: 518-761-8206 • F a x: 518-745-4437 firemarshal@queensbury.net • www.queensbury.net ATTACHMENT B HORIZONTAL UL RATING —C-OPY • . ,. . B Fl-oor/Leiling8 . . .. . . . . .: .."-. " .. ... . . . , . . Wood Framed 0 i Hour Fire Rated•Construction DinieltOmol Lumber.' I Acoustical Pertaiininieci •'Reference.: Construction Detail Description :Test Number I STC I Test Number Index tig.wt.5 • 4vo layers.5113"Soocp5i7F.E.Eogi Care: CA4C406.-;5 . .Dr-;57 , ---.........--,r.-.........--..:,-:..:-....,--,...-T.,-.. gypsum oanek .. -: and• . 1 , —n 111.kodjolsts,24°o.c.. RC-2601 \i —face IO*.jolattlinth0 —&ler:112'''plypOod with extending glue III ., 11° 'AO fOr rookeilos;iiidth'116.tuses. . . . ATTACHMENT C DESIGN NO. GAWP 3910 VERTICAL UL RATING FIRE RATING: 2 HOURS STC RATING: 53 SOUND TEST: USG-171222 SYSTEM THICKNESS: 8"[203 MM] LOCATION: INTERIOR FRAMING TYPE: WOOD STUD(LOAD-BEARING) 16" 16" 16" 16" x f [406 mm] [406 mm] I' [406 mm] f [406 mm] I 1 8" 8" 51 [203 mm]1[203 mm]1 E 1 CoE 1(I 0 1 1 �y II ASSEMBLY REQUIREMENTS: 0F' GYPSUM PANELS: TWO LAYERS 5/8"[15.9 MM]SHEETROCK®GYPSUM PANEL(UL TYPE SCX) . WOOD STUDS: 2"X 4"[38 X 89 MM]WOOD STUDS,STAGGERED,8"[203 MM]O.C. INSULATION: 3-1/2"[89 MM]FIBERGLASS INSULATION GYPSUM PANELS: TWO LAYERS 5/8"[15.9 MM]SHEETROCK®GYPSUM PANEL(UL TYPE SCX) GENERAL WALL NOTES: 1. REFER TO APPLICABLE CODES REQUIREMENTS TO ENSURE COMPLIANCE PRIOR TO CONSTRUCTION. 2. FOR THE MOST UP-TO-DATE DETAILS,INCLUDING CONSTRUCTION VARIATIONS,REFER TO THE PUBLISHED DESIGN. 3. WHERE DESIGN NO.INDICATES"PER",THE FIRE RATING IS BASED ON LABORATORY TEST DATA OF THE REFERENCED ' SIMILARLY CONSTRUCTED ASSEMBUES. 4. STUD SIZES AND INSULATION THICKNESS ARE MINIMUM UNLESS OTHERWISE STATED IN THE PUBLISHED ASSEMBLY. 5. STUD AND FASTENER SPACINGS ARE MAXIMUM UNLESS OTHERWISE STATED IN THE PUBLISHED ASSEMBLY. 6. PANEL ORIENTATION SHALL BE AS SPECIFIED IN THE PUBLISHED DESIGN. 7. FIRE-RATINGS ARE FROM BOTH SIDES UNLESS OTHERWISE STATED. 8. FIRE-RATINGS ARE MAINTAINED WITH ONE OR MORE OF THE FOLLOWING MODIFICATIONS:INCREASE STUD DEPTH, INCREASE STUD MATERIAL THICKNESS,DECREASE STUD SPACING,DECREASE FASTENER SPACING,INCREASE INSULATION THICKNESS UP TO CAVITY DEPTH. 9. WHERE ACOUSTICAL PERFORMANCE IS PROVIDED IN AN ESTIMATED RANGE,THE VALUES ARE BASED ON LABORATORY TEST DATA OF SIMILARLY CONSTRUCTED ASSEMBLIES. 10. SOUND-RATINGS ARE MAINTAINED WITH ONE OR MORE OF THE FOLLOWING MODIFICATIONS:INCREASE STUD DEPTH, DECREASE STUD MATERIAL THICKNESS,INCREASE STUD SPACING,INCREASE FASTENER SPACING,INCREASE INSULATION THICKNESS UP TO CAVITY DEPTH.MODIFICATIONS MUST NOT EXCEED LIMITATIONS OF FIRE RATING. USG1111101 ��� OOCLAnER iv vWo �oawian tovrwo[ox Rrn,Rr wr¢rmrorM USE As ISSUE SHEET INFORMATION: "xtwrEETS.MENEM.AM OREn DEMON PROTESSONNS. aoNmc.oRs.awwa CODE orFcius.ano,NFnw.wETEx.wNSTRUCT.MATEY,R.nE RECORD: PRorEsswaMIN.roAN MEREST xT E MaEoroR MPECEGTON,ANO USE or masers _ ` TE' � °LOF° `°m GA W P 3910 USG Corporation LMEroaTrEOORWIN MO O USE OPEE EODUCTS DEMOO Revision Date W-P-2 11 550 West Adams Street BE FOR THE PROJECT.THESE EWM..MY BE PANTED AMOR rnwsrERREo Ch' IL 606fi1 USA x¢cmowvur SOLELY AS NEEDED BY TV USER BEGUSE C.ELECTRONIC r'EES MO BY Lw.USG.Can MEMOvawWME WODELsms.LCOI ATIC CM EII OFUSE mMOM.GD wIWHES sm%wLEon T.800-USG4YOU RPs s...RV BESOV PROFESS... 10/0512621 11:56:45 PM f 1 Page I1 aJ architecture Memo a planning . Re: 378 Queensbury Ave. Jared Ross, Owner CO Date: October 18, 2022 " Attention: Mark Smith, Code Enforcement Officer Building & Code Enforcement 742 Bay Road, Queensbury, NY 12804 518-761-8276 Foundation Design Criteria The design criteria below is based on the 2020 Residential Code of New York State design requirements and tables. Given the construction type and loading are the same as residential we used the residential code tables.The original design architect has passed since issuing the drawings. We reviewed the design architect's foundation design against the code requirements. Below are our findings: Foundation footings Table R403.1 (1) MINIMUM WIDTH AND THICKNESS FOR CONCRETE FOOTINGS FOR LIGHT-FRAME CONSTRUCTION • Load-bearing value of soil: 2500 psf • Snow load/roof live load: 60 psf • 2-story-plus basement Findings: 24"x12" footings as shown on plans exceed code requirements of 16"x6". 518.792.1651 www.ajaarchitecture.com - — — — Page 12 Foundation wall Table R404.1.2(8) MINIMUM VERTICAL REINFORCEMENT FOR 6-, 8-, 10-AND 12-INCH NOMINAL FLAT BASEMENT WALLS • Maximum wall height: 7 ft. (below grade) • Nominal wall thickness: 8 in. • Soil class: GW, GP, SW, SP, 30 Findings: #4 bars @ 48" as noted on plans exceed code requirements. Conclusion: Foundation walls and footings on submitted plans appear to be in compliance with NYS code requirements. End of notes. ,,ce.RED �Rc ,��\=O�EW J A4� 2 Y if* r . • • Ow N itt ,-"-v 4o.02879�� �' Andrew J.Allison, R.A. AIA AJA Architecture and Planning October 18, 2022 518.792.1651 www.ajaarchitecture.com FORTE E JOB SUMMARY REPORT ATTACHMENT A 378 Queensbury Ave 1ST FLOOR FRAMING Member Name Results Current Solution Comments BEAM 1 -Passed 3 piece(s)1 3/4"x 9 1/4"2.0E Microllam@ LVL BEAM 2 Passed 4 piece(s)1 3/4"x 11 7/8"2.0E Microllam@ LVL BEAM 3 Flush Passed ,2 piece(s)1 3/4"x 9 1/2"2.0E Microllam@ LVL Wall:Header 1 Passed 3 piece(s)2 x 10 SPF No.1/No.2 Wall:Header 2 Passed 3 piece(s)2 x 10 SPF No.1/No.2 Floor:Joist 1 Passed 1 piece(s)2 x 10 SPF No.1/No.2 @ 16"OC Floor:Joist 2 Passed 1 piece(s)2 x 10 SPF No.1/No.2 @ 16"OC 2ND FLOOR FRAMING Member Name Results Current Solution Comments BEAM 4 Passed �2 piece(s)1 3/4"x 9 1/4"2.0E Microllam@ LVL Wall:Header 3 Passed 3 piece(s)13/4"x 9 1/2"2.0E Microllam@ LVL Floor:Joist 5 Passed 1 piece(s)2 x 10 SPF No.1/No.2 @ 16"OC Floor:Joist 6 Passed 2 piece(s)2 x 10 SPF No.1/No.2 @ 16"OC ROOF FRAMING Member Name Results Current Solution Comments Wall:Header 4 Passed 3 piece(s)13/4"x 9 1/2"2.0E Microllam@ LVL FILE, COPY �FtED qR - n * CP }`���' '9� 4b rc 02879$N _Op Pj ,Jt1.,. 516 7q I� 5l ForteWEB Software Operator ]ob Notes 9/2/2022 3:52:31 PM UTC Jen Denis AJA Architecture ForteWEB v3.4 (518)792-1651 jdenis@ajaarchitecture.com Weyerhaeuser File Name:378 Queensbury Ave Page 1/1 ,t 'I Manual S Compliance Report Job: 378 queensbury ave apt... Date: Oct 12,2022 Entire House By: Plan: 378 queensbury ave AR.. Y . Project Information For: jerad ross FILE Cooling Equipment Design Conditions Outdoor design DB: 85.0°F Sensible gain: 9410 Btuh Entering coil DB: 75.2°F Outdoor design WB: 71.0°F Latent gain: 1205 Btuh Entering coil WB: 62.6°F Indoor design DB: 75.0°F Total gain: 10615 Btuh Indoor RH: 50% Estimated airflow: 503 cfm • Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: York Model: TCGF18S41S3+FC18A3XC1++S1-1TVM4F1 • Actual airflow: 577 cfm Sensible capacity: 0 Btuh 0% of load Latent capacity: 0 Btuh 0% of load Total capacity: 0 Btuh 0% of load SHR: 0% Heating Equipment Design Conditions Outdoor design DB: -4.0°F Heat loss: 44006 Btuh Entering coil DB: 65.8°F Indoor design DB: 68.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: York Model: TM9X060B12MP11 Actual airflow: 577 cfm Output capacity: 57000 Btuh 130% of load Temp. rise: 50 °F bl'i 0CT 1 '+ 2022 T__________. OWN► OF QUEENSBURY BUILDING& COOPS Meets are all requirements of ACCA Manual S. 2022-Oct-12 09:06:21 wrightsoft® Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 ACCk ...thy\Documents\York\378 QUEENSBURYAVE APT B.rup Calc=MJ7 Front Door faces: N Residential Plans Examiner Review Form Form RPER 1 ACCk® for HVAC System Design (Loads, Equipment, Ducts) 15Mar09 AFCcolaiig CaoalasdArreira QUEENSBURY NY Header Information Contractor: REQUIRED ATTACHMENTS ATTACHED Manual J1 Form(and supporting worksheets): Yes 0 No El Mechanical license: or MJ1AE Form*(and supporting worksheets): Yes 0 No OEM performance data(heating,cooling,blower): Yes 0 No D Building plan#: 378 Manual D Friction Rate Worksheet: Yes 0 No D queensbury Duct distribution sketch: Yes El No Home address(Street06. $I6ck,Subdivision): , Entire House HVAC LOAD CALCULATION (IRC M1401.3) Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature: _4 °F Orientation: Front Door faces North Indoor temperature: 68 °F North,East,West,South,Northeast,Northwest,Southeast,Southwest Total heat loss: 44006 Btuh Number of bedrooms: 2 . Conditioned floor area: 985 ft2 Summer Design Conditions Number of occupants: 0 Outdoor temperature: 85 °F Indoor temperature: 75 °F Windows Roof Grains difference: 27 gr/Ib @60% RH Eave overhang depth: 0 ft Sensible heat gain: 10456 Btuh Internal shade: none Eave Latent heatgain: Blinds,drapes,etc. 1339 Btuh Depth Window Total heat gain: 11795 Btuh Number of skylights: 0 HVAC EQUIPMENT SELECTION (IRC M1401.3) Heating Equipment Data Cooling Equipment Data Blower Data Equipment type: Gas furnace Equipment type: Split AC Heating cfm: 577 . umace,Hea pump,Boiler,etc. it onditioner,Heat pump,etc. Cooling cfm: 577 Model: York Model: York Static pressure: 0 in H2O TM9X060B12MP11 TCGF18S41 S3 Fan's rated extemal static pressure for design airflow Heating output capacity: 57000 Btuh Total cooling capacity: 0 Btuh Heat pumps-capacity at winter design ou door conditions Sensible cooling capacity: 0 Btuh Aux.heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1) Design airflow: 577 cfm Longest supply duct: 0 ft Duct Materials Used Equipment design ESP: 0 in H2O Longest return duct: 0 ft Trunk duct: Total device pressure losses: 0 in H2O Total effective length(TEL): 0 ft Available static pressure(ASP): 0 in H2O Friction rate: 0 in/100ft Branch duct: Sheet metal Friction Rate=ASP+(TELx 10 ) I declare the load calculation,equipment,equipment selection and duct design were rigorously performed based on the building plan listed above. I understand the claims made on these forms will be subjectto review and verification. Contractor's printed name: Contractor's signature: Date: Reserved for County,Town Municipality or Authority having jurisdiction use. *Home qualifies for MJ1AE Form based on Abridged Edition Checklist -1- wrightsoft® Right-Suite®Universal 2017 17.0.16 RSU25116 r \ Project Summary Job: 378 queensbury ave apt... Date: Oct 12,2022 Entire House By: Plan: 378 queensbury ave AR.. Pro'ect Information For: jerad ross Notes: Desi• n Information Weather: Glens Falls AP, NY, US Winter Design Conditions Summer Design Conditions Outside db -4 °F Outside db 85 °F Inside db 68 °F Inside db 75 °F Design TD 72 °F Design TD 10 °F Daily range M Relative humidity 50 % Moisture difference 27 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 41515 Btuh Structure 8962 Btuh Ducts 2491 Btuh Ducts 448 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 44006 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 8469 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1205 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ftZ) 985 985 Equipment latent load 1205 Btuh Volume(ft') 7880 7880 Air changes/hour 1.00 0.50 Equipment total load 9674 Btuh Equiv.AVF (cfm) 131 66 Req. total capacity at 0.70 SHR 1.0 ton Heating Equipment Summary Cooling Equipment Summary Make York Make York Trade YORK Trade LATITUDE Model TM9X060B12MP11 Cond TCGF18S41S3 AHRI ref 2008693 Coil FC18A3XC1++S1-1TVM4F1 AHRI ref 4676522 Efficiency 95.5 AFUE Efficiency 11.5 EER, 14 SEER Heating input 60000 Btuh Sensible cooling 12110 Btuh Heating output 57000 Btuh Latent cooling 5190 Btuh Temperature rise 90 °F Total cooling 17300 Btuh Actual air flow 577 cfm Actual air flow 577 cfm Air flow factor 0.013 cfm/Btuh Air flow factor 0.061 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. Wrl htsoft® 2022-Oct-12 09:06:21 9 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 ACCf'. ...thy\Documents\York\378 QUEENSBURYAVEAPT B.rup Calc=MJ7 Front Door faces: N Rig ht-J®Worksheet Job: 378 queensburyave apt b Entire House Date: Oct 12,2022 By: Plan: 378 queensbury ave APT B MANUAL J:7th Ed. 1 Name of room Entire House Room1 Room2 Room3 2 Length of exposed wall 161.0 ft 106.0 ft 20.0 ft 23.0 ft 3 Room dimensions 21.0 x 32.0 ft 11.0 x 9.0 ft 10.0 x 13.0 ft 4 Ceilings Condit.Option 8.0 ft d 8.0 ft heat/cool 8.0 ft heat/cool 8.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg 5 Gross a 12A0 19.5 3.7 1288 **** **** 846 **** **** 160 **** **** 184 **** **** Exposed b 0 0 IIIII1 **** **** IIIII1 **** **** IIIIII **** **** I Ili lI **** **** walls and c 0 0 IIII!! **** **** will **** **** null **** **** mill **** **** partitions d 0 0 will **** **** win **** **** tutu **** **** IIIIII **** **** e 0 0 I!!!!! **** ***" !I!!!! **** **** IIIIII **** **** !!I!!! **** **** f 0 0 IIIIII **** **** 1IHi! **** **** IIIIII **** **** !!!III **** **** 6 Windows and a 3A0 39.7 ** 75 2975 **** 45 1785 "*** 15 595 **** 15 595 **** glass doors b 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** Heating c 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** f 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** 7 Windows and North 19.0 30 **** 570 0 **** 0 15 **** 285 15 **** 285 glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Cooling E/W 68.0 15 **** 1020 15 **** 1020 0 **** 0 0 **** 0 SE/SW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 South 34.0 30 **** 1020 30 **** 1020 0 **** 0 0 **** 0 Horz 0 0 **** 0 0 **** 0 0 ***" 0 0 **** 0 8 Other doors a 1OD0 33.1 6.3 21 696 131 , 21 696 131 0 0 0 0 0 0 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12A0 19.5 3.7 1192 23258 4393 782 15258 2882 145 2829 534 169 3298 623 exposed b 0 0 !roll 0 0 !III!! 0 0 111111 0 0 111111 0 0 walls and c 0 0 rim! 0 0 !!!!!! 0 0 111111 0 0 111111 0 0 partitions d 0 0 Inn! 0 0 I!ll!! 0 ,0 111111 0 0 !!I!!! 0 0 e 0 0 wn111 0 0 !!!III 0 0 111111 0 0 III!!! 0 0 f 0 0 will 0 0 111111 0 0 !!IIII 0 0 HIM 0 0 10 Ceilings a 16G0 2.4 1.1 985 2340 1105 672 1597 754 99 235 111 130 309 146 b 0 0 will 0 0 !!!III 0 0 111111 0 0 111111 0 0 C 0 0 !IIII! 0 0 IIIIII 0 0 111111 0 0 111111 0 0 d 0 0 IIIIII 0 0 MI!! 0 0 IIIIII 0 0 111111 0 0 e 0 0 IIIIII 0 0 111111 0 0 111111 0 0 111111 0 0 f 0 0 IIIIII 0 0 !!!!!! 0 0 IIIIII 0 0 IIIIII 0 0 11 Floors a 19D0 1.9 0 985 1844 0 672 1258 0 99 185 0 130 243 0 (Note:room b 0 0 IIIIII 0 0 111111 0 0 nun 0 0 !!IIII 0 0 perimeter c 0 0 IIIIII 0 0 !!!!I! 0 0 111111 0 0 !II!!! 0 0 is displ. d 0 0 III!!! 0 0 111111 0 0 111111 0 0 111111 0 0 for slab e 0 0 IIIIII 0 0 111111 0 0 111111 0 0 IIII!! 0 0 floors) f 0 0 will 0 0 IIIIII 0 0 111111 0 0 IIII!! 0 0 12 Infiltration a 108 7.5 96 10402 722 66 7151 497 15 1625 113 15 1625 113 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 **** 41515 **** **** 27745 **** **** 5470 **** **** 6070 **** Less external heating **** 0 **** **** 0 **** **** 0 **** **** 0 **** Less transfer ***" 0 **** **** 0 **** **** 0 **** **** 0 **** Heating redistribution **** 0 **** **** 0 **** **** 0 **** **** 0 **** 14 Duct loss 6% 2491 **** 6% 1665 **** 6% 328 **** 6% 364 **** 15 Total loss=13+14 **** 44006 **** **** 29410 **** **** 5796 **** **** 6434 **** 16 Int.gains: People @ 300 0 "*** 0 0 **** 0 0 *"** 0 0 **** 0 Appl. @ 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0 17 Subtot RSH gain=7+8..+12+16 **** **** 8962 **** **** 6304 **** **** 1043 **** **** 1167 Less external cooling **** **** 0 **** **** 0 **** **** 0 **** **** 0 Less transfer **** **** 0 **** **** 0 **** **** 0 **** **** 0 Cooling redistribution **** **** 0 **** **** 0 **** **** 0 **** **** 0 18 Duct gain 5% **** 448 5% **** 315 5% **** 52 5% **** 58 19 Total RSH gain=(17+18)*PLF 1.00 **** 9410 1.00 *"** 6619 1.00 **** 1096 1.00 **** 1225 20 Air required(cfm) 577 577 385 406 76 67 84 75 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. wrightSOfr Right-Suite®Universal 2017 17.0.16 RSU25116 2022-Oct-12 09:06:21Page 1 . dk ...thy\Documents\York\378 QUEENSBURYAVEAPT B.rup Calc=MJ7 Front Door faces: N '/ Rig ht-J®Worksheet Job: 378 queensbury ave apt b Entire House Date: Oct 12,2022 By: Plan: 378 queensbury ave APT B MANUAL J:7th Ed. 1 Name of room Room4 Room5 2 Length of exposed wall 3.0 ft 9.0 ft 3 Room dimensions 1.0 x 29.0 ft 1.0 x 55.0 ft 4 Ceilings Condit.Option 8.0 ft heat/cool 8.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Area EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg Htg Clg Htg Clg 5 Gross a 12A0 19.5 3.7 24 **** **** 72 **** **** **** **** ***It It*** Exposed b 0 0 I!1!!! **** **** II ill I **** **** **** **** **** **** walls and c 0 0 IIIIII **** **** II III! **** **** **** **** **** **** partitions d 0 0 II!!!! **** **** !ill lI **** **** *** **** **** **** e 0 0 III!!! **** **** IIIIII **** **** **** **** **** **** f 0 0 III 11! **** **** !!I!!! **** **** **** **** **** **** 6 Windows and a 3A0 39.7 ** 0 0 **** 0 0 **** **** **** glass doors b 0 ** 0 0 **** 0 0 **** **** **** Heating c 0 ** 0 0 **** 0 0 **** **** **** d 0 ** 0 0 **** 0 0 **** **** **** e 0 ** 0 0 **** 0 0 **** **** **** f 0 ** 0 0 **** 0 0 **** **** **** 7 Windows and North 19.0 0 **** 0 0 **** 0 **** **** glass doors NE/NW 0 0 **** 0 0 **** 0 **** **** Cooling E/W 68.0 0 **** 0 0 **** 0 **** **** SE/SW 0 0 **** 0 0 **** 0 **** **** South 34.0 0 **** 0 0 **** 0 **** **** Horz 0 0 **** 0 0 **** 0 **** **** 8 Other doors a 1OD0 33.1 6.3 0 0 0 0 0 0 b 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 9 Net a 12A0 19.5 3.7 24 468 88 72 1405 265 exposed b 0 0 will 0 0 111111 0 0 walls and c 0 0 111111 0 0 !!I!!! 0 0 partitions d 0 0 111111 0 0 111111 0 0 e 0 0 1111!! 0 0 HIM 0 0 f 0 0 111111 0 0 !Urn 0 0 10 Ceilings a 16G0 2.4 1.1 29 69 33 55 131 62 b 0 0 !!!I!! 0 0 III!!! 0 0 c 0 0 III!!! 0 0 HMI 0 0 d 0 0 111111 0 0 !!I!I! 0 0 e 0 0 111111 0 0 !!II!I 0 0 f 0 0 111111 0 0 !I!!Il 0 0 11 Floors a 19D0 1.9 0 29 54 0 55 103 0 (Note:room b 0 0 IIIIII 0 0 IIlI1! 0 0 perimeter c 0 0 will 0 0 IIIIII 0 0 is displ. d 0 0 111111 0 0 11111! 0 0 for slab e 0 0 111111 0 0 111111 0 0 floors) f 0 0 !1!!I! 0 0 !!!1I! 0 0 12 Infiltration a 108 7.5 0 0 0 0 0 0 Ventilation 0 0 0 0 13 Subtotal loss=6+8..+11+12 **** 591 **** **** 1639 **** **** **** **** **** Less external heating **** 0 **** **** 0 **** **** **** **** **** Less transfer **** 0 **** **** 0 **** **** **** **** **** Heating redistribution **** 0 **** **** 0 **** **** **** **** **** 14 Duct loss 6% 35 **** 6% 98 **** **** **** 15 Total loss=13+14 **** 627 **** **** 1737 **** **** **** **** **** 16 Int.gains: People @ 300 0 **** 0 0 **** 0 **** **** Appl. @ 1200 0 **** 0 0 **** 0 **** **** 17 Subtot RSH gain=7+8..+12+16 **** **** 121 **** **** 327 **** **** **** **** Less external cooling **** **** 0 **** **** 0 **** **** **** **** Less transfer **** **** 0 **** **** 0 **** **** **** **** Cooling redistribution **** **** 0 **** **** 0 **** **** **** **** 18 Duct gain 5% **** 6 5% **** 16 **** **** 19 Total RSH gain=(17+18)*PLF 1.00 **** 127 1.00 **** 343 **** **** 20 Air required(cfm) 8 8 23 21 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. * wrightsoft" 2022-Oct-12 09:06:21 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 2 ACCP. ...thy\Documents\York\378 QUEENSBURYAVEAPT B.rup Calc=MJ7 Front Door faces: N . 4 i i Py � i� OIII V� ' Y 'Y .GIq• "� 1�1 V::� IIII � iII $t I4II � ,l� i ,, $ ', 4' ly 41 1 U .Yr i`OR�J�;13 rtltr;ia Pr't:':.:,E d ;i1Yi'F itt `trt�l':3'i9 It9�rat::F,:;1` * , Good air quality Is based la part on the capacity of tho home's Yentilatiun system. fealty,the umat'S capacity.is ;r- in ra; ' measured In CFM(Cubic Feet per Minute) or Lie(Liters per second)of freak air be): g distr`bute Pair le ll a,Fair �� epee,Use the AutiFi�1E Fi2.2' r>ntileatian Standard. the Room Count Calculation Cut tla�d,a� ;._ Hew(ACM Method tock terrarrna your vaattiU€tti:aai needs. #, s�'s,ieal`if#iia1,C: 4'r�:.cy li'C;PYidl+r,'lIU'�r4 ;;Y,i'Iatu;,i,¢6afd l , • i ASHRAE 62.2 CFM Sizing Chart y — ."�'" r I 1 1 Number of Bedrooms$CFM ' ., Floor Area'(ft' 10.1, 12-3 4-6 16.7 4 i>7 !. . 1500 I so 145 00 175 •ii 190 'd6b1 -30011 .� 45 i r'si1 "s'6 8t3 1 il�'.�i 3001 •4500 1160 17 � • . I 1 t7:Y ' 120 } . 14501 . 6000 I 51,90 106 120 135 6001 -7500 i 90 1 '105 - 120 1135 I''�: 450 :0 7500 105 ! 120 1135 1 150 li 1 165 I ANSItASKRAE,;STANDARD d'b .2.2O1 t:0-Ventilation Air!Requirements:values in eV;i i F' 4 'The above chart outlines the minimum requirements for r6tntiriitmis ventilation. it , . t! i • 6- '( 5y-5� LicCFiv' (.071,a4S is ) co% = 2ocFri P . .( P 1 • I . t, 11 1 i i I • • i. i N. o Fresh Air Systems - 150 CFM BRIherin ERV ____ :TI E` Top ports: B160E65RT BRS N' /ll �Stde. ports: B160E65RS ..w,. ,a.4/::u ..,.f 35 toa,50 CFM @ 0.2 in.w.g. treo 40 CFM @ 0.4 in,w.g. NRAI OGC A1VAA1,DA Ui.GAI* g CERTIFIED Parts/Motor/ERV Core rime -` .-_- - Visit www.broan-nutone.com for complete warranty text. Introducing the industry's most advanced residential fresh air r system, created to offer a universal platform specifically designed and !Unit Description improved to make contractors life easier and more profitable while L delivering constant superior air quality. • SRE of 67%at 32°F and 56%at-13°F(64 CFM) • Thanks to the Virtuo Air Technologym • the airflow • Ports size:6" calibration and auto-balancingare achieved quicklyand • Recirculation mode Recirculation defrost maintained throughout the life of the product • Corrosion resistant galvanized steel door and body • Select the desired CFM (from 35 to 150 CFM)using the • One-piece molded insulation shell, no air leakage very first integrated LCD screen.The airflow is then set up automatically (expanded polystyrene; UL 94 HF-1 certified) • Integrated electronic airflow measurement device with • Virtuo constant airflow and auto-balancing device real time LCD (patent pending) • Integrated diagnostic tool • Motorized dampers(no additional backdraft dampers • Equipped with PMSM ECM motors for a very low power • required) No drain required consumption • 6'power cord • Suspended installation (chains included) • Unit electrical characteristics: OR 120 volts,60 Hz,2.5 A, 163 W • Wall-mount installation (universal brackets included) • Sound:73.2 dBA at 150 CFM @ 0.4 in.w.g. • installation with 2 brackets 60.1 dBA at 64 CFM @ 0.2 in w, _g. • installation with 4 brackets [controls _ ' !Core ADVANCED 20-40-60 - AUTOMATIC SPEED SELECTOR TOUCHSCREEN DELUXE ' Polypropylene crossflow core,impact resistant, _ washable non s ble • • Dimensions: 12" x 12" x 9" (30.5 cm x 30.5 cm x 23 cm) gi. I - iFilters - - _' :vl. ems._ , _ - — -- - _._ - - -- _ • j _ ' i • MERV 8 grade washable standard filter(included) ---_ -- • Optional MERV13 grade filter part no.V24285 There are 4 optional main controls and 2 optional auxiliary _ __ -__ _ __ _ controls available. Refer to Wall Control specification sheet 'Options for more information. _ • Complete line of registers and diffusers • Compatible with the Tandem transition (part no.VTYIK1) PRODUCT SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. (for units producing up to 110 CFM only) 45" Ports Dimensions (Top Ports) 1 - Exhaust air from building il�� Total assembled weight:approx 37 lbs(16.8 kg)(core included) 2- Fresh air to building rillin Shipping weight:approx 44 Ibs(20 kg) 3-Exhaust air to outside ��� (U 4-Fresh air from outside Q (� sorlimmiorm ` t Clearance I �I e 6 TYP. 21 1-i F 9 for ducting i� mismokil r rar, t�l. �� ra 0 211/2 a 1— IN 1914 ip -� Clearance required for ( i— �� m ntefl `ance . • .. I 1�183/a - 8--.- t 16'/a--►I Latches Drains Power cord Terminals 6"Ports Dimensions Side Ports) - 23+/2 ),I Total assembled weight:approx 37 lbs(16.8 kg)(core included)I 2- Fresh air to building ' 3- Exhaust air to outside L 1 2 ] [ 4- Fresh air from outside e 6 TYR. 4 311 •--9—.{ Clearance ' 21 for ducting 1—Id I-i— • 11W I II r .r-- .._. ______. ..,_.,_, 191/e kg Clearance required for maintenance .i. *•' I I -183/a—'1 8 •-�• 16'/a--).-1Latches Drains Power cord Terminals towns Dimensions shown in inches 1 Defrost System - HomeshieldTM Defrosting System DISCRETION OW ot4u14TEMPERATURE' No negative pressure is created "°"Selling) -5°CTO-15°C -15°CTo-27°C -27°C AND(ES by air exhausted to the outdoors 4itimo 23°F To5°F 5'Fso-17°F -17°FaNO LESS -• C�_ AR rxoE DErrosr Am ExouN°E DcrRosT AR ExouNcc DcrrosT since the air is recirculated into rc 11�.1 CFM -,the house, helping to prevent any ----""IL_ ___:, oto59 25 6 14 5 13 7 backdraft. 60to104 25 6 15 5 14 7 105 and more 15 6 10 5 19 7 'Outdoor temperature is read by a thermistor located inside the unit,next to fresh air from outdoor port. wit ,� NOTE:There is a 10-minute additional defrost every 5 defrost cycles. W PLUS OUTIxk1R TEMPERATURE' -5°C TO-15°C -15°C TO-27°C -27°C AND LESS 23°F To 5°fi 5°FTo-17°F -17°F AND LEss CFM AR Exu oxoc DE,ROST AR Exow4°E Dorrosr AR DEC..,CuE DVRos, W MVd TCS W MOxnnS IN MINUTES W MINUTES ei MUMES IN MINUTES 0 to 59 25 7 14 7 12 8 60 to 104 25 7 15 7 13 8 105 and more 15 7 10 7 9 8 'Outdoor temperature is read by a thermistor located inside the unit,next to fresh air.from outdoor port. NOTE:There is a 10-minute additional defrost every 5 defrost cycles. iFan Curves with Virtuo - Thanks to Virtuo Air TechnologyTM,no need to balance the unit manually.Both PMSM motors are controlled by an artificial intelligence performing 120 readings per minute then processing this information to maintain the requested airflow. For typical installation, Virtuo will ensure a balanced ventilation at every selected speed regardless of the weather conditions, the type of connection,the variable speed furnace/AHU, the stack effect, the filter clogging and so on.This results in peace of mind for installers and users knowing that the unit will always remain balanced and that it will maintain its maximum heat/energy recovery efficiency. STanc Srnrc Ncr Sunsr Ncr Surn, GROSS Geo. Gross Gross 1 PRESSURE PRESSURE Arnow A'RTLow ARTEow Amnow Arnow Am-Low (R4 (x.w.c.) (Vs) (a.) Surar Sons. Ewuusr Ewuus, 09 (VS) (crr.) (Vs) (cr.) • - . . 25 0.1 73 155 74 157 74 157 as . 50 0.2 71 150 72 153 72 153 • --0.7 75 0.3 68 144 69 146 69 146 3 I I 100 0.4 66 140 67 142 67 142 =os 125 0.5 64 136 65 138 65 138 @a.as • 150 0.6 62 131 63 133 63 133 5 04 • 175 0.7 59 125 60 127 60 127 I` . • 200 0.8 57 121 58 123 58 123 3 03 225 0.9 54 114 55 117 55 117 02 250 1.0 52 110 53 112 53 112 01 Affl tOWls wayAp)OSTA8&8WTh 1.CFM.CPufanENr 0 10 20 30 40 50 60 70 80 90 Sm 110 120 130 140 1s0 HA 170 Net Airflow(CFM) II - _ _ _ ,,tnergy Performance SUPPLY NET AIRFLOW ADJUSTED LATENT ADJUSTED TEMPERATURE POWER SENSIBLE SENSIBLE RECOVERY/ APPARENT TOTAL CONSUMED RECOVERY SENSIBLE RECOVERY TOTAL °C °F Is CFM WATTS EFFICIENCY RECOVERY MOISTURE EFFECTIVENESS* EFFICIENCY RECOVERY EFFICIENCY TRANSFER EFFICIENCY HEATING 0 32 30 64 32 67 70 0.65 72 - - 0 32 63 133 112 63 69 0.53 71 - -25 -13 30 64 57 56 58 0.62 72 - - 35 95 33 70 36 - - 0.54 60 56 58 35 95 65 138 138 - - 0.43 51 42 46 *Data not certified by HVI. `Requirements and Standards — -- - • UL 1812 compliant(safety) • Complies with ROHS 2015/863 directive • Could be installed in compliance with CSA F326 • Compliant with Prop 65 • Performance tested as per CSA C439 Standard • Can be used to comply with California Title 24 2019 Part 6 Fault Indicator Display Requirements II Project: Remarks i. Location: Part no.: Qty.: Submitted by: Date: BN. l ei+e Broan-NuTone LLC,926 West State Street,Hartford,Wisconsin,USA 53027 Broan-NuTone.com 800-558-1711 1108598E .4 ATTACHMENT D COMcheck Software Version COMcheckWeb Envelope Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: 378 Queensbury Ave - Location: Glens Falls, New York Climate Zone: 6a FIE 9OPY Project Type: New Construction Vertical Glazing/Wall Area: 13% Construction Site: Owner/Agent: Designer/Contractor: 378 Queensbury Ave Jared Ross Queensbury, New York 12804 Additional Efficiency Package(s) Credits: 1.0 Required 1.0 Proposed Reduced Lighting Power, 1.0 credit Building Area Floor Area 1-Apt A(Multifamily): Residential 540 • 2-Basement/Storage/Mech(Multifamily): Residential 1302 3-Apt C(Multifamily): Residential 895 4-Apt B(Multifamily) : Residential 672 Envelope Assemblies Assembly Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factor(a) Perimeter Floor: Unheated Slab-On-Grade,[Bldg. Use 2- 174 — -- 0.730 0.520 Basement/Storage/Mech] (c) Roof:Attic Roof,Wood Joists, [Bldg. Use 3-Apt C] 895 49.0 0.0 0.021 0.021 Roof:Attic Roof,Wood Joists, [Bldg. Use 1-Apt A] 540 49.0 0.0 0.021 0.021 Roof:Attic Roof,Wood Joists, [Bldg. Use 4-Apt B] 672 49.0 0.0 0.021 0.021 NORTH Wall Al:Wood-Framed, 16in. o.c., [Bldg. Use 1-Apt A] 145 21.0 0.0 0.062 0.051 Window:Vinyl Frame: Operable, Perf. Specs.: Product ID 16 — -- 0.280 0.430 30410, SHGC 0.30, PF 1.50, [Bldg. Use 1-Apt A] (b) Wall B1:Wood-Framed, 16in.o.c., [Bldg. Use 4-Apt B] 168 21.0 0.0 0.062 0.051 Window:Vinyl Frame: Operable, Perf.Specs.: Product ID 16 -- -- 0.280 0.430 30410, SHGC 0.30, PF 1.50, [Bldg. Use 4-Apt B] (b) Window:Vinyl Frame: Operable, Perf.Specs.: Product ID 16 — -- 0.280 0.430 30410, SHGC 0.30, PF 1.50, [Bldg. Use 4-Apt B] (b) Wall C3:Wood-Framed, 16in. o.c., [Bldg. Use 3-Apt C] 145 21.0 0.0 0.062 0.051 Window:Vinyl Frame:Operable, Perf. Specs.: Product ID 9 — — 0.280 0.430 30210, SHGC 0.30, PF 1.50, [Bldg. Use 3-Apt C] (b) Door:Wood,Swinging, [Bldg. Use 3-Apt C] 22 -- -- 0.260 0.370 Wall Al:Wood-Framed, 16in. o.c., [Bldg. Use 1-Apt A] 145 21.0 0.0 0.062 0.051 Basement Wall 1: Solid Concrete, 8in.Thickness, Normal 299 -- 15.0 0.061 0.119 Density, Furring: None,Wall Ht 7.7, Depth B.G. 7.0, [Bldg. Use 2-Basement/Storage/Mech] Basement Wall 3:Solid Concrete, 8in.Thickness, Normal 61 -- 15.0 0.061 0.119 Density, Furring: None,Wall Ht 7.7, Depth B.G. 7.0, [Bldg. Use Project Title: 378 Queensbury Ave Report date: 09/12/22 Data filename: Page 1 of 19 1 Assembly Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factor)a) Perimeter 2-Basement/Storage/Mech] Basement Wall 13:Solid Concrete, 8in.Thickness, Normal 61 -- 15.0 0.061 0.119 Density, Furring: None,Wall Ht 7.7, Depth B.G. 7.0, [Bldg. Use 2-Basement/Storage/Mech] EAST Wall A2:Wood-Framed, 16in. o.c., [Bldg. Use 1-Apt A] 240 21.0 0.0 0.062 0.051 Window:Vinyl Frame:Operable, Perf. Specs.: Product ID 16 - -- 0.280 0.430 30410, SHGC 0.30, PF 1.50, [Bldg. Use 1-Apt A] (b) Window:Vinyl Frame: Operable, Perf. Specs.: Product ID 16 - - 0.280 0.430 30410, SHGC 0.30, PF 1.50, [Bldg. Use 1-Apt A] (b) Door:Wood,Swinging, [Bldg. Use 1-Apt A] 22 - -- 0.260 0.370 Wall B4:Wood-Framed, 16in. o.c., [Bldg. Use 4-Apt B] 16 21.0 0.0 0.062 0.051 Wall C4:Wood-Framed, 16in.o.c., [Bldg. Use 3-Apt C] 240 21.0 0.0 0.062 0.051 Window:Vinyl Frame: Operable, Perf. Specs.: Product ID 32 -- -- 0.280 0.430 30410-2, SHGC 0.30, PF 1.50, [Bldg. Use 3-Apt C] (b) Window:Vinyl Frame: Operable, Perf. Specs.: Product ID 16 -- -- 0.280 0.430 30410, SHGC 0.30, PF 1.50, [Bldg. Use 3-Apt C] (b) Basement Wall 2:Solid Concrete, 8in.Thickness, Normal 15 -- 15.0 0.061 0.119 Density, Furring: None,Wall Ht 7.7, Depth B.G. 7.0, [Bldg. Use 2-Basement/Storage/Mech] Basement Wall 4:Solid Concrete, 8in.Thickness, Normal 41 - 15.0 0.061 0.119 Density, Furring: None,Wall Ht 7.7, Depth B.G. 7.0, [Bldg. Use 2-Basement/Storage/Mech] Basement Wall 6:Solid Concrete, 8in.Thickness, Normal 171 - 15.0 0.061 0.119 Density, Furring: None,Wall Ht 7.7, Depth B.G. 7.0, [Bldg. Use 2-Basement/Storage/Mech] Window:Vinyl Frame: Operable, Perf.Specs.: Product ID sash, 5 - -- 0.280 0.430 SHGC 0.30, PF 1.50,[Bldg. Use 2-Basement/Storage/Mech] (b) Basement Wall 8:Solid Concrete, 8in.Thickness, Normal 15 - 15.0 0.061 0.119 Density, Furring: None,Wall Ht 7.7, Depth B.G. 7.0, [Bldg. Use 2-Basement/Storage/Mech] SOUTH Wall A3:Wood-Framed, 16in. o.c., [Bldg. Use 1-Apt A] 145 21.0 0.0 0.062 0.051 Window:Vinyl Frame: Operable, Perf.Specs.: Product ID 16 - -- 0.280 0.430 30410, SHGC 0.30, PF 1.50, [Bldg. Use 1-Apt A] (b) Window:Vinyl Frame: Operable, Perf.Specs.: Product ID 16 - -- 0.280 0.430 30410, SHGC 0.30, PF 1.50, [Bldg. Use 1-Apt A] (b) Wall B3:Wood-Framed, 16in.o.c., [Bldg. Use 4-Apt B] 168 21.0 0.0 0.062 0.051 Window:Vinyl Frame: Operable, Perf.Specs.: Product ID 16 -- - 0.280 0.430 30410, SHGC 0.30, PF 1.50, [Bldg. Use 4-Apt B] (b) Window:Vinyl Frame: Operable, Perf.Specs.: Product ID 16 -- - 0.280 0.430 30410, SHGC 0.30, PF 1.50, [Bldg. Use 4-Apt B] (b) Door:Wood,Swinging, [Bldg. Use 4-Apt B] 22 -- -- 0.260 0.370 Wall C5:Wood-Framed, 16in. o.c., [Bldg. Use 3-Apt C] 145 21.0 0.0 0.062 0.051 Window:Vinyl Frame: Operable, Perf. Specs.: Product ID 16 - -- 0.280 0.430 30410, SHGC 0.30, PF 1.50, [Bldg. Use 3-Apt C] (b) Window:Vinyl Frame: Operable, Perf. Specs.: Product ID 16 -- - 0.280 0.430 30410, SHGC 0.30, PF 1.50, [Bldg. Use 3-Apt C] (b) Basement Wall 5: Solid Concrete, 8in.Thickness, Normal 61 - 15.0 0.061 0.119 Density, Furring: None,Wall Ht 7.7, Depth B.G. 7.0, [Bldg. Use 2-Basement/Storage/Mech] Basement Wall 7: Solid Concrete, 8in.Thickness, Normal 138 -- 15.0 0.061 0.119 Density, Furring: None,Wall Ht 7.7, Depth B.G. 7.0, [Bldg. Use 2-Basement/Storage/Mech] Basement Wall 9:Solid Concrete, 8in.Thickness, Normal 161 - 15.0 0.061 0.119 Density, Furring: None,Wall Ht 7.7, Depth B.G. 7.0, [Bldg. Use 2-Basement/Storage/Mech] Basement Wall 11: Solid Concrete, 8in.Thickness, Normal 61 - 15.0 0.061 0.119 Density, Furring: None,Wall Ht 7.7, Depth B.G. 7.0, [Bldg. Use 2-Basement/Storage/Mech] Project Title: 378 Queensbury Ave Report date: 09/12/22 Data filename: Page 2 of 19 Assembly Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factor(a) Perimeter WEST • Wall B2:Wood-Framed, 16in.o.c.,[Bldg. Use 4-Apt B] 256 21.0 0.0 0.062 0.051 Window:Vinyl Frame: Operable, Perf.Specs.: Product ID 16 — — 0.280 0.430 30410,SHGC 0.30, PF 1.50, [Bldg. Use 4-Apt B] (b) Wall C2:Wood-Framed, 16in. o.c., [Bldg. Use 3-Apt C] 64 21.0 0.0 0.062 0.051 Wall C6:Wood-Framed, 16in.o.c., [Bldg. Use 3-Apt C] 40 21.0 0.0 0.062 0.051 Wall C8:Wood-Framed, 16in.o.c., [Bldg. Use 3-Apt C] 145 21.0 0.0 0.062 0.051 Window:Vinyl Frame:Operable, Perf.Specs.: Product ID 32 -- -- 0.280 0.430 30410-2,SHGC 0.30, PF 1.50, [Bldg. Use 3-Apt C] (b) Basement Wall 10:Solid Concrete,8in.Thickness, Normal 186 — 15.0 0.061 0.119 Density, Furring: None,Wall Ht 7.7, Depth B.G. 7.0, [Bldg. Use 2-Basement/Storage/Mech] Window:Vinyl Frame:Operable, Perf. Specs.: Product ID sash, 5 — -- 0.280 0.430 SHGC 0.30, PF 1.50, [Bldg. Use 2-Basement/Storage/Mech](b) Basement Wall 12: Solid Concrete,8in.Thickness, Normal 41 — 15.0 0.061 0.119 Density, Furring: None,Wall Ht 7.7, Depth B.G. 7.0, [Bldg. Use 2-Basement/Storage/Mech] Basement Wall 14: Solid Concrete,8in.Thickness, Normal 15 -- 15.0 0.061 0.119 Density,Furring: None,Wall Ht 7.7, Depth B.G. 7.0, [Bldg. Use 2-Basement/Storage/Mech] (a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. (b)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (c)Slab-On-Grade proposed and budget U-factors shown in table are F-factors. Envelope PASSES: Design 15% better than code Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application.The proposed envelope systems have been designed to meet the 2018 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Andrew J.Allison - � 9/12/2022 Name-Title Signature Date .,ce(1ED ARc (u���el '4 y>.T Nert 410 9T iL, �� F •o2ar� .40 Project Title: 378 Queensbury Ave Report date: 09/12/22 Data filename: Page 3 of 19 frift COMcheck Software Version COMcheckWeb ill Interior Lighting Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: 378 Queensbury Ave Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: 378 Queensbury Ave Jared Ross Queensbury, New York 12804 Additional Efficiency Package(s) Credits: 1.0 Required 1.0 Proposed Reduced Lighting Power, 1.0 credit Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 1-Apt A(Dormitory:Living Quarters) 540 0.49 265 2-Basement/Storage/Mech (Common Space Types:Storage>=1000 sq.ft.) 1302 0.41 534 3-Apt C (Dormitory:Living Quarters) 895 0.49 439 4-Apt B (Dormitory:Living Quarters) 672 0.49 329 Total Allowed Watts= 1566 Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixture Watt. 1-Apt A(Dormitory:Living Quarters) LED: Fan: Basis of design: Home Depot Mod:Other: 1 2 9 18 LED:Overhead: Basis of design: Home Depot Mod: LED A Lamp 25W: 1 4 25 100 LED: Recessed: Basis of design: Home Depot Mod: Other: 1 1 12 12 LED: Bath Fan Light: Basis of design: Home Depot Mod: Other: 1 1 49 49 LED:Vanity: Basis of design: Home Depot Mod: Other: 4 1 22 22 2-Basement/Storage/Mech (Common Space Types:Storage >=1000 sq.ft.) LED: Recessed: Basis of design: Home Depot Mod: Other: 1 12 12 144 3-Apt C (Dormitory:Living Quarters) LED: Fan: Basis of design: Home Depot Mod:Other: 1 4 9 36 LED:Overhead: Basis of design: Home Depot Mod: LED A Lamp 25W: 1 3 25 75 LED: Recessed: Basis of design: Home Depot Mod: Other: 1 4 12 48 LED: Bath Fan Light: Basis of design: Home Depot Mod: Other: 1 1 49 49 LED:Vanity: Basis of design: Home Depot Mod: Other: 4 1 22 22 4-Apt B (Dormitory:Living Quarters) LED: Fan: Basis of design: Home Depot Mod:Other: 1 3 9 27 LED:Overhead: Basis of design: Home Depot Mod: LED A Lamp 25W: 1 4 25 100 LED: Recessed: Basis of design: Home Depot Mod: Other: 1 2 12 24 LED: Bath Fan Light: Basis of design: Home Depot Mod: Other: 1 1 49 49 Project Title: 378 Queensbury Ave Report date: 09/12/22 Data filename: Page 4 of 19 A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixture Watt. LED:Vanity: Basis of design: Home Depot Mod: Other: 4 1 22 22 Total Proposed Watts= 797 Interior Lighting PASSES: Design 49% better than code Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. , Andrew J.Allison 9/12/2022 Name-Title Signature Date qRC ��`�`voPEW�.44e Y,,,, '�.N Ilelti. ° . tl t�! Project Title: 378 Queensbury Ave Report date: 09/12/22 Data filename: Page 5 of 19 . . COMcheck Software Version COMcheckWeb tit Exterior Lighting Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: 378 Queensbury Ave Project Type: New Construction Exterior Lighting Zone 2 (Light industrial area with limited nighttime use (LZ2)) Construction Site: Owner/Agent: Designer/Contractor: 378 Queensbury Ave Jared Ross Queensbury, New York 12804 Allowed Exterior Lighting Power A B C D E Area/Surface Category Quantity Allowed Tradable Allowed Watts Watts/ Wattage (B X C) Driveway(Driveway) 2880 ft2 0.04 Yes 115 4 Car Parking (Parking area) 1360 ft2 0.04 Yes 54 Total Tradable Watts(a)= 170 Total Allowed Watts= 170 Total Allowed Supplemental Watts(b)= 400 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 400 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixture Watt. Driveway(Driveway. 2880 ft2):Tradable Wattage LED: Post: Basis of design: Home Depot Mod: LED Other Fixture Unit 16W: 3 1 300 300 4 Car Parking (Parking area. 1360 ft2):Tradable Wattage LED:Wall Mount: Basis of design: Home Depot Sco: LED Other Fixture Unit 40W: 1 1 40 40 Total Tradable Proposed Watts= 340 Exterior Lighting PASSES: Design 40% better than code Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application.The proposed exterior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Andrew J.Allsion .�_ i 9/12/2022 Name-Title Signature Date Cs¢ED A„, • e .fx y • ,� FOP/1F1! Project Title: 378 Queensbury Ave Report date: 09/12/22 Data filename: Page 6 of 19 COMcheck Software Version COMcheckWeb Mechanical Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: 378 Queensbury Ave Location: Glens Falls, New York Climate Zone: 6a Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: 378 Queensbury Ave Jared Ross Queensbury, New York 12804 Additional Efficiency Package(s) Credits: 1.0 Required 1.0 Proposed Reduced Lighting Power, 1.0 credit Mechanical Systems List Quantity System Type&Description 1 HVAC System(Multiple-Zone): Heating: 1 each-Duct Furnace, Gas,Capacity= 30 kBtu/h Proposed Efficiency=96.00%Ec, Required Efficiency: 80.00% Ec Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2018 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name-Title Signature Date Project Title: 378 Queensbury Ave Report date: 09/12/22 Data filename: Page 7 of 19 , _. COMcheck Software Version COMcheckWeb IIInspection Checklist Energy Code: 2018 IECC Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID C103.2 Plans and/or specifications provide all ❑Complies Requirement will be met. [PR1]1 information with which compliance ❑Does Not can be determined for the building envelope and document where ONot Observable exceptions to the standard are ONot Applicable claimed. C103.2 Plans,specifications,and/or ❑Complies Requirement will be met. [PR2]1 calculations provide all information ❑Does Not with which compliance can be determined for the mechanical ['Not Observable systems and equipment and ❑Not Applicable document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. i i i C103.2 Plans,specifications,and/or ❑Complies Requirement will be met. [PR4]1 calculations provide all information ❑Does Not with which compliance can be determined for the interior lighting ONot Observable and electrical systems and equipment ONot Applicable and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations,wattage of bulbs and ballasts,transformers and control devices. C103.2 ;Plans,specifications,and/or ❑Complies Requirement will be met. [PR8]1 calculations provide all information ❑Does Not ;with which compliance can be ;determined for the exterior lighting [Not Observable land electrical systems and equipment ENot Applicable ;and document where exceptions to ;the standard are claimed. Information provided should include exterior lighting power calculations,wattage of ;bulbs and ballasts,transformers and ;control devices. C402.4.1 The vertical fenestration area <=30 ❑Complies Requirement will be met. [PR1O]1 percent of the gross above-grade wall ❑Does Not area. ❑Not Observable ❑Not Applicable C402.4.1 ;The skylight area <= 3 percent of the ❑Complies Requirement will be met. [PR11]1 l gross roof area. ElDoes Not ['Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 378 Queensbury Ave Report date: 09/12/22 Data filename: Page 8 of 19 • Section Plan Review Complies? Comments/Assumptions & Req.ID C405.5 Group R-2 dwelling units have ❑Complies Requirement will be met. [PR16]1 separate electrical meters. ❑Does Not ['Not Observable ❑Not Applicable C406 ;Plans,specifications, and/or OComplies Requirement will be met. [PR9]i calculations provide all information ❑Does Not !with which compliance can be ❑Not Observable determined for the additional energy efficiency package options. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 378 Queensbury Ave Report date: 09/12/22 Data filename: Page 9 of 19 Section # Footing/Foundation Inspection Complies? Comments/Assumptions & Req.ID C303.2 I Below-grade wall insulation installed ❑Complies Requirement will be met. [FO2]2 !per manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable C303.2 Slab edge insulation installed per EComplies Requirement will be met. [FO4]2 ;manufacturer's instructions. ❑Does Not ❑Not Observable ENot Applicable C303.2.1 Exterior insulation protected against ElComplies Requirement will be met. [FO6]1 damage,sunlight, moisture,wind, ❑Does Not landscaping and equipment maintenance activities. Not Observable ❑Not Applicable C402.1.4 I Installed below-grade wall insulation ❑Complies See the Envelope Assemblies table for values. [FO1]2 !type and R-value consistent with ❑Does Not insulation specifications reported in I plans and COMcheck reports. ['Not Observable ❑Not Applicable C105 ;Installed slab-on-grade insulation type ❑Complies See the Envelope Assemblies table for values. [FO3]2 land R-value consistent with insulation ❑Does Not specifications reported in plans and COMcheck reports. ❑Not Observable { ❑Not Applicable C402.2.4 ;Slab edge insulation depth/length. ❑Complies Requirement will be met. [FO7]2 !Slab insulation extending away from ❑Does Not building is covered by pavement or See the Envelope Assemblies table for values. {>= 10 inches of soil. [Not Observable ❑Not Applicable C403.12.2;Snow/ice melting system and freeze ❑Complies Exception: Requirement does not apply. !protection systems have sensors and ❑Does Not C403.12.3;controls configured to limit service for ❑Not Observable [FO9]3 ;pavement temperature and outdoor temperature.future connection to ❑Not Applicable controls. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 378 Queensbury Ave Report date: 09/12/22 Data filename: Page 10 of 19 Section # Framing/Rough-In Inspection Complies? Comments/Assumptions & Req.ID C303.1.3 1Fenestration products rated in ❑Complies Requirement will be met. [FR12]2 !accordance with NFRC. ❑Does Not ❑Not Observable ❑Not Applicable C303.1.3 :Fenestration products are certified as ❑Complies Requirement will be met. [FR13]1 to performance labels or certificates ❑Does Not ;provided. [Not Observable ❑Not Applicable C402.4.3 Vertical fenestration SHGC value. ❑Complies See the Envelope Assemblies table for values. [FR10]1 ❑Does Not ❑Not Observable ❑Not Applicable C402.4.3, Installed vertical fenestration U-factor ❑Complies See the Envelope Assemblies table for values. C402.4.3. and SHGC consistent with label ❑Does Not 4 specifications and as reported in plans [FR8]1 and COMcheck reports. ['Not Observable ❑Not Applicable C402.5.7 'Vestibules are installed on all building ❑Complies Exception: Requirement does not apply. [FR17]3 entrances. Doors have self-closing ❑Does Not jdevices. ['Not Observable ❑Not Applicable Additional Comments/Assumptions: • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 378 Queensbury Ave Report date: 09/12/22 Data filename: Page 11 of 19 Section Plumbing Rough-In Inspection Complies? Comments/Assumptions &Req.ID C404.5, ;Heated water supply piping conforms ❑Complies Requirement will.be met. C404.5.1, Ito pipe length and volume ElDoes Not C404.5.2 requirements. Refer to section details. [PL6]3 j ['Not Observable ❑Not Applicable C404.6.3 ;Pumps that circulate water between a ❑Complies Exception: Requirement does not apply. [PL713 heater and storage tank have controls ❑Does Not ;that limit operation from startup to ['Not Observable <= 5 minutes after end of heating Icycle. ❑Not Applicable C404.7 Demand recirculation water systems ❑Complies Exception: Requirement does not apply. [PL8]3 have controls that start the pump ❑Does Not ;upon receiving a signal from the action of a user of a fixture or ❑Not Observable appliance and limits the temperature ❑Not Applicable of the water entering the cold-water piping to 104°F. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 378 Queensbury Ave Report date: 09/12/22 Data filename: Page 12 of 19 Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C402.2.6 !Thermally ineffective panel surfaces of❑Complies Exception: Requirement does not apply. [ME41]3 !sensible heating panels have ❑Does Not insulation >= R-3.5. ['Not Observable ! ❑Not Applicable C402.5.5, Stair and elevator shaft vents have ElComplies Exception: Requirement does not apply. C403.2.4. ;motorized dampers that automatically ElDoes Not 3 ,close. Refernece section C403.7.7 for [ME3]3 !operational details. ❑Not Observable ❑Not Applicable C403.7.7 Outdoor air and exhaust systems have ❑Complies Exception: Requirement does not apply. [ME58]3 ;motorized dampers that automatically ❑Does Not shut when not in use and meet maximum leakage rates. Check ENot Observable gravity dampers where allowed. ❑Not Applicable !Reference section language for ;operational details. C403.8.1 !HVAC fan systems at design ❑Complies Requirement will be met. [ME65]3 conditions do not exceed allowable, ❑Does Not fan system motor nameplate hp or fan See the Mechanical Systems list for values. ;system bhp. [Not Observable ❑Not Applicable C403.8.3 ;Fans have efficiency grade(FEG) >= ElComplies Requirement will be met. [ME117]z }67.The total efficiency of the fan at ❑Does Not !the design point of operation <= 15% of maximum total efficiency of the ['Not Observable fan. ❑Not Applicable C403.12.1 Systems that heat outside the building ElComplies Exception: Requirement does not apply. [ME71]z envelope are radiant heat systems ❑Does Not ;controlled by an occupancy sensing I device or timer switch. Not Observable j DNot Applicable C403.2.1 ;Zone isolation devices and controls ElComplies Requirement will be met. [ME112]3 ;installed where applicable. DDoes Not ['Not Observable ONot Applicable C403.2.2 Natural or mechanical ventilation is ❑Complies Exception: Requirement does not apply. [ME59]1 provided in accordance with ❑Does Not International Mechanical Code Chapter 4. Mechanical ventilation has ❑Not Observable capability to reduce outdoor air supply ❑Not Applicable to minimum per IMC Chapter 4. C403.7.1 Demand control ventilation provided ❑Complies Exception: Requirement does not apply. [ME59]1 for spaces>500 ft2 and >25 ❑Does Not people/1000 ft2 occupant density and ['Not Observable served by systems with air side economizer,auto modulating outside ❑Not Applicable air damper control, or design airflow >3,000 cfm. C403.7.2 Enclosed parking garage ventilation LJComplies Exception: Requirement does not apply. [ME115]3 t has automatic contaminant detection ❑Does Not and capacity to stage or modulate ;fans to 50%or less of design capacity. ['Not Observable ❑Not Applicable C403.7.6 :HVAC systems serving guestrooms in ❑Complies Exception: Requirement does not apply. [ME141]3 !Group R-1 buildings with > 50 ❑Does Not guestrooms: Each guestroom is ;provided with controls that ['Not Observable automatically manage temperature ❑Not Applicable !setpoint and ventilation (see sections 1C403.7.6.1 and C403.7.6.2). 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 378 Queensbury Ave Report date: 09/12/22 Data filename: Page 13 of 19 Section Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C403.7.4 ;Exhaust air energy recovery on ❑Complies Exception: Requirement does not apply. [ME57]1 isystems meeting Table C403.7.4(1) ❑Does Not ;and C403.7.4(2). ['Not Observable ❑Not Applicable C403.7.5 Kitchen exhaust systems comply with ❑Complies Exception: Requirement does not apply. [ME116]3 replacement air and conditioned ❑Does Not ;supply air limitations,and satisfy hood Irating requirements and maximum ENot Observable exhaust rate criteria. ENot Applicable • i C403.11.1 HVAC ducts and plenums insulated in ❑Complies Requirement will be met. accordance with C403.11.1 and ❑Does Not C403.11.2;constructed in accordance with ❑Not Observable [ME60]z IC403.11.2,verification may need to occur during Foundation Inspection. ❑Not Applicable C403.4.1. ;Heating for vestibules and air curtains ❑Complies Exception: Requirement does not apply. 4 with integral heating include ❑Does Not [ME63]z •/automatic controls that shut off the [Not Observable heating system when outdoor air temperatures>45F.Vestibule ENot Applicable ;heating and cooling systems controlled by a thermostat in the (vestibule with heating setpoint<= 60F and cooling setpoint>=80F. C408.2.2. {Air outlets and zone terminal devices ❑Complies Exception: Requirement does not apply. 1 have means for air balancing. ❑Does Not [ME53]3 • ❑Not Observable j DNot Applicable C403.5, I Refrigerated display cases,walk-in ❑Complies Exception: Requirement does not apply. C403.5.1, ;coolers or walk-in freezers served by ❑Does Not C403.5.2 ;remote compressors and remote [ME123]3 Icondensers not located in a ❑Not Observable 'condensing unit, have fan-powered ❑Not Applicable condensers that comply with Sections C403.5.1 and refrigeration compressor systems that comply with C403.5.2.. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 378 Queensbury Ave Report date: 09/12/22 Data filename: Page 14 of 19 Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2.2. Spaces required to have light- ❑Complies Exception: Lighting that is related to means of egress in 2 reduction controls have a manual ❑Does Not stairways, ramps,corridors,or emergency routes. [EL22]1 control that allows the occupant to reduce the connected lighting load in Not Observable a reasonably uniform illumination ❑Not Applicable pattern >= 50 percent. C405.2.1, Occupancy sensors installed in ❑Complies Exception: Requirement does not apply. C405.2.1. !classrooms/lecture/training rooms, ❑Does Not 1 conference/meeting/multipurpose [EL18]1 ;rooms, copy/print rooms, ['Not Observable I lounges/breakrooms,enclosed offices, ENot Applicable ;open plan office areas, restrooms, storage rooms, locker rooms, 'warehouse storage areas,and other spaces<=300 sqft that are enclosed by floor-to-ceiling height partitions. Reference section language C405.2.1.2 for control function in warehouses and section C405.2.1.3 for open plan office spaces. C405.2.1. ;Occupancy sensors control function in ❑Complies Exception: Requirement does not apply. 2 'warehouses: In warehouses,the ❑Does Not [EL19]1 ;lighting in aisleways and open areas is ;controlled with occupant sensors that ['Not Observable automatically reduce lighting power ❑Not Applicable by 50%or more when the areas are unoccupied.The occupant sensors ;control lighting in each aisleway independently and do not control lighting beyond the aisleway being ;controlled by the sensor. C405.2.1. Occupant sensor control function in ❑Complies Exception: Requirement does not apply: 3 open plan office areas: Occupant ❑Does Not [EL20]1 _sensor controls in open office spaces ['Not Observable >= 300 sq.ft. have controls 1) configured so that general lighting can ❑Not Applicable be controlled separately in control zones with floor areas <=600 sq.ft. within the space, 2)automatically turn off general lighting in all control zones within 20 minutes after all occupants have left the space,3)are configured so that general lighting power in each control zone is reduced by>= 80%of the full zone general lighting power within 20 minutes of all occupants leaving that control zone, and 4) are configured such that any daylight responsive control will activate space general lighting or control zone general lighting only when occupancy for the same area is detected. C405.2.2, Each area not served by occupancy ❑Complies Exception: Lighting that is related to means of egress in C405.2.2. sensors(per C405.2.1) have time- ❑Does Not stairways, ramps,corridors,or emergency routes. 1, switch controls and functions detailed ['Not Observable C405.2.2. in sections C405.2.2.1 and C405.2.2.2. 2 ❑Not Applicable [EL21]2 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 378 Queensbury Ave Report date: 09/12/22 Data filename: Page 15 of 19 Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2.3, ;Daylight zones provided with ❑Complies Exception: Requirement does not apply. C405.2.3. 'individual controls that control the ❑Does Not 1, lights independent of general area C405.2.3. ;lighting.See code section C405.2.3 ['Not Observable 2 'Daylight-responsive controls for ONot Applicable [EL23]2 applicable spaces,C405.2.3.1 Daylight responsive control function and section C405.2.3.2 Sidelit zone. C405.2.4 ;Separate lighting control devices for ❑Complies Requirement will be met. [EL26]1 ;specific uses installed per approved ❑Does Not lighting plans. :Not Observable :Not Applicable C405.2.4 Additional interior lighting power ❑Complies Requirement will be met. [EL27]1 allowed for special functions per the ❑Does Not approved lighting plans and is automatically controlled and Not Observable separated from general lighting. ❑Not Applicable C405.2.5 ;Manual controls required by the ❑Complies Requirement will be met. [EL28]no0 energy code are in a location with ❑Does Not ready access to occupants and located where the controlled lights are ❑Not Observable visible,or identify the area served and ❑Not Applicable their status. C405.2.6 Automatic lighting controls for exterior ❑Complies Exception: Requirement does not apply. [EL30]no0 lighting installed.Controls will be ❑Does Not daylight controlled, set based on business operation time-of-day,or ❑Not Observable reduce connected lighting > 30%. ❑Not Applicable C405.3 Exit signs do not exceed 5 watts per ❑Complies Exception: Requirement does not apply. [EL6]1 face. ❑Does Not ['Not Observable ❑Not Applicable C405.6 ;Low-voltage dry-type distribution ❑Complies Requirement will be met. [EL26]2 electric transformers meet the ❑Does Not ;minimum efficiency requirements of ['Not Observable iTable C405.6. ❑Not Applicable C405.7 Electric motors meet the minimum ❑Complies Requirement will be met. [EL27]2 !efficiency requirements of Tables ❑Does Not ;C405.7(1)through C405.7(4). !Efficiency verified through certification ['Not Observable under an approved certification ❑Not Applicable program or the equipment efficiency E ratings shall be provided by motor manufacturer(where certification programs do not exist). C405.8.2, ;Escalators and moving walks comply ❑Complies Exception: Requirement does not apply. C405.8.2. 'with ASME A17.1/CSA B44 and have ❑Does Not 1 ;automatic controls configured to [EL28]2 I reduce speed to the minimum ❑Not Observable permitted speed in accordance with ❑Not Applicable ;ASME A17.1/CSA B44 or applicable local code when not conveying passengers. C405.9 ;Total voltage drop across the ❑Complies Requirement will be met. [EL29]2 combination of feeders and branch ❑Does Not circuits<=5%. pilot Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 378 Queensbury.Ave Report date: 09/12/22 Data filename: Page 16 of 19 Section # Insulation Inspection Complies? Comments/Assumptions & Req.ID C303.1 ;Roof insulation installed per ❑Complies Requirement will be met. [IN3]i imanufacturer's instructions. Blown or DDoes Not poured loose-fill insulation is installed only where the roof slope is <=3 in ❑Not Observable 12. ❑Not Applicable E C402.2.1 Insulation installed on a suspended ❑Complies Exception: Requirement does not apply. [IN20]i ceiling having ceiling tiles is not being ❑Does Not specified for roor/ceiling assemblies. Continuous insulation board installed ❑Not Observable in 2 or more layers with edge joints ❑Not Applicable offset between layers. C303.1 !Building envelope insulation is labeled ❑Complies Requirement will be met. [IN10]z with R-value or insulation certificate ❑Does Not ;providing R-value and other relevant data. [Not Observable ❑Not Applicable C303.2 !Above-grade wall insulation installed ❑Complies Requirement will be met. [IN7]i i per manufacturer's instructions. ❑Does Not ['Not Observable ❑Not Applicable C105 ;Installed above-grade wall insulation ❑Complies See the Envelope Assemblies table for values. [IN6]1 (type and R-value consistent with ❑Does Not ;insulation specifications reported in plans and COMcheck reports. ['Not Observable ❑Not Applicable C402.2.3 ;Installed floor insulation type and R- ❑Complies See the Envelope Assemblies table for values. [IN8]z !value consistent with insulation ❑Does Not ;specifications reported in plans and COMcheck reports. ❑Not Observable ❑Not Applicable C402.2.6 ;Radiant panels and associated ❑Complies Exception: Requirement does not apply. [IN18]3 I components,designed for heat ❑Does Not ;transfer from the panel surfaces to the I occupants or indoor space are Not Observable :insulated with a minimum of R-3.5. ❑Not Applicable C105 ;Installed roof insulation type and R- ❑Complies See the Envelope Assemblies table for values. [IN2)' :value consistent with insulation ❑Does Not ;specifications reported in plans and ;COMcheck reports. For some ceiling ❑Not Observable' systems,verification may need to ENot Applicable ;occur during Framing Inspection. C402.5.1. ;All sources of air leakage in the ❑Complies Requirement will be met. 1 i building thermal envelope are sealed, ❑Does Not ['NIP caulked,gasketed,weather stripped ;or wrapped with moisture vapor- Not Observable permeable wrapping material to ❑Not Applicable ;minimize air leakage. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 378 Queensbury Ave Report date: 09/12/22 Data filename: Page 17 of 19 Section Final Inspection Complies? Comments/Assumptions & Req.ID C303.3, Furnished O&M instructions for ❑Complies Requirement will be met. C408.2.5. ;systems and equipment to the DDoes Not 2 I building owner or designated [FI17]3 ;representative. ['Not Observable DNot Applicable C303.3, I Furnished O&M manuals for HVAC DComplies Requirement will be met. C408.2.5. :systems within 90 days of system ❑Does Not 3 ;acceptance. [F18]3 ` ['Not Observable ❑Not Applicable C402.5 ;Building envelope contains a DComplies Requirement will be met. [F155]1 continuous air barrier that has been ❑Does Not ;tested and deemed to limit air leakage ❑Not Observable <= 0.40 cfm/ft2. ❑Not Applicable C402.5.6 Weatherseals installed on all loading DComplies Exception: Requirement does not apply. [F137]1 dock cargo door openings and provide ODoes Not direct contact along the top and sides of vehicles parked in the doorway. ['Not Observable ❑Not Applicable C403.2.2 ;HVAC systems and equipment DComplies Requirement will be met. [FI27]3 ;capacity does not exceed calculated ❑Does Not loads. ['Not Observable ENot Applicable C403.2.4. Heating and cooling to each zone is DComplies Requirement will be met. 1 'controlled by a thermostat control. ❑Does Not [FI47]3 ;Minimum one humidity control device ENot Observable ;per installed I humidification/dehumidification ❑Not Applicable system. C403.4.1. ;Thermostatic controls have a 5 °F DComplies Requirement will be met. 2 i deadband. ❑Does Not [FI38]3 ❑Not Observable ❑Not Applicable C403.2.4. Temperature controls have setpoint DComplies Exception: Requirement does not apply. 1.3 overlap restrictions. ❑Does Not [F120]3 ENot Observable ❑Not Applicable C403.2.4. ;Each zone equipped with setback DComplies Exception: Requirement does not apply. 2 !controls using automatic time clock or ❑Does Not [FI39]3 j programmable control system. ['Not Observable ENot Applicable C403.2.4. ;Automatic Controls: Setback to 55°F DComplies Exception: Requirement does not apply. 2.1, ;(heat)and 85°F(cool); 7-day clock,2- ❑Does Not C403.2.4. ;hour occupant override, 10-hour 2.2 i backup ONot Observable [F140]3 I ENot Applicable C405.4.1 Interior installed lamp and fixture DComplies See the Interior Lighting fixture schedule for values. [FI18]1 lighting power is consistent with what ❑Does Not is shown on the approved lighting plans, demonstrating proposed watts ['Not Observable are less than or equal to allowed ❑Not Applicable watts. C405.5.1 Exterior lighting power is consistent DComplies See the Exterior Lighting fixture schedule for values. [FI19]1 with what is shown on the approved ❑Does Not lighting plans, demonstrating proposed watts are less than or equal ENot Observable to allowed watts. ENot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 378 Queensbury Ave Report date: 09/12/22 Data filename: Page 18 of 19 Section Final Inspection Complies? Comments/Assumptions &Req.ID C408.1.1 Building operations and maintenance DComplies Requirement will be met. [FI57]1 documents will be provided to the ❑Does Not owner. Documents will cover manufacturers' information, ❑Not Observable specifications, programming :Not Applicable procedures and means of illustrating to owner how building,equipment and systems are intended to be installed, maintained,and operated. C408.2.1 ;Commissioning plan developed by DComplies Requirement will be met. [FI28]1 registered design professional or ❑Does Not ;approved agency. ENot Observable ENot Applicable C408.2.3. HVAC equipment has been tested to DComplies Requirement will be met. 1 ensure proper operation. ❑Does Not [FI31]1 ['Not Observable ❑Not Applicable C408.2.3. ;HVAC control systems have been DComplies Requirement will be met. 2 tested to ensure proper operation, ❑Does Not [FI10]1 :calibration and adjustment of controls. ONot Observable ❑Not Applicable C408.2.4 Preliminary commissioning report DComplies Requirement will be met. [FI29]1 completed and certified by registered ❑Does Not ;design professional or approved agency. ❑Not Observable ❑Not Applicable C408.2.5. ;Furnished HVAC as-built drawings DComplies Requirement will be met. 1 !submitted within 90 days of system ❑Does Not [F17]3 acceptance. [Not Observable ❑Not Applicable C408.2.5. ;Furnished as-built drawings for DComplies Requirement will be met. 1 !electric power systems within 90 days ❑Does Not [FI16]3 :of system acceptance. ENot Observable ❑Not Applicable C408.2.5. ;An air and/or hydronic system DComplies Requirement will be met. 3 balancing report is provided for HVAC ❑Does Not [FI43]1 ;systems. :Not Observable ❑Not Applicable C408.2.5. ;Final commissioning report due to DComplies Requirement will be met. 4 'building owner within 90 days of ❑Does Not [F130]1 receipt of certificate of occupancy. ['Not Observable ❑Not Applicable C408.3 ;Lighting systems have been tested to DComplies Requirement will be met. [F133]1 ensure proper calibration,adjustment, ❑Does Not programming, and operation. [Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 378 Queensbury Ave Report date: 09/12/22 Data filename: Page 19 of 19 ATTACHMENT E Goodman° GM9C96 Air Conditioning&Heating HEATING INPUT: 30,000-120,000 BTU/H TWO STAGE, MULTI SPEED ECM GAS FURNACE UP To 96%AFUE Contents Nomenclature 2 Product Specifications 3 Goodman Dimensions 4 Airflow Specifications 5 Wiring Diagrams 14 Accessories 15 • Standard Features Cabinet Features • Energy-efficient,multi-speed ECM blower motor • Designed for multi-position installation— • Heavy-duty,aluminized-steel tubular heat exchanger upflow,horizontal left or right • Stainless-steel secondary heat exchanger • Certified for direct vent(2-pipe) • Two-stage gas valve provides quiet,economical heating or non-direct vent(1-pipe) • Durable Silicon Nitride igniter • Easy-to-install top venting with optional side venting • Quiet two-speed induced draft blower • Convenient left or right connection • Self-diagnostic control board with constant for gas and electrical service memory fault code history output to a LED Cabinet air leakage(Qi.eak)<_2% • Color-coded low-voltage terminals with provisions • Heavy-gauge steel cabinet with durable finish for electronic air cleaner and humidifier • Fully insulated heat exchanger and blower section • • Low continuous fan speed options offer quiet air circulation • Airtight solid bottom or side return with easy-cut tabs • All models comply with California 40 ng/J for effortless removal in bottom air-inlet applications Low NOx emissions standard • Can no longer be installed in California's South Coast Air Quality Management District(SCAQMD) on or after October 1,2019. • AHRI Certified;ETL Listed LIFETIME 11 n UNIT in PARTS Nm; ` COMPANY WITH CER71F_ED' QUALITY`..P M ENYu1ONNENTAL SYSTEM REPLACEMENT c us �..- - CERTIFIED BY DM CERTIFIED BY MY GL HEAT EXCHANGER LIMITED LIMITED ISo10301= LIMITED WARRANTY' YEAR WARRANTY' YEAR WARRANTY' Intertek • Complete warranty details available from your local dealer or at www.goodmanmfg.com.To receive the Lifetime Heat Exchanger limited Warranty(good for as long BBB' asyou ownyour home),10-Year Unit Replacement Limited Warrantyand 10-Year Parts Limited Warran I}`n" s� ) p ty,.online registration must be completed within 60 days of • installation.Online registration is not required in California or Quebec. SS-GM9C96 www.goodmanmfg.com 8/21 NOMENCLATURE G M 9 C 96 040 4 C * ** 1 2 3 4 5,6 7,8,9 10 11 12 13,14 BRAND ENGINEERING G-Goodman°Brand Major/Minor Revisions A-Initial Release B-1st Revision CONFIGURATION NOx M-Upflow/Horizontal N=>40 NG/J NOx C-Downflow/Horizontal X=<40 NG/J NOx MOTOR CABINET WIDTH 9- Nine Speed ECM A-14" C-21" B-17A" D-24%" GAS VALVE MAXIMUM CFM C-2 Stage 3-1200 CFM 4-1600 CFM 5-2000 CFM AFUE MBTU/H 80-80%AFUE 92-92%AFUE 030-30,000 BTU/h 080-80,000 BTU/h 96-96%AFUE 97-97%AFUE 040-40,000 BTU/h 100-100,000 BTU/h 060-60,000 BTU/h 120-120,000 BTU/h • 2 www.goodmanmfg.com SS-GM9C96 ,. t . i PRODUCT SPECIFICATIONS GM9C96 GM9C96 GM9C96 GM9C96 GM9C96 GM9C96 GM9C96 GM9C96 GM9C96 0303ANA 0403ANA 0603ANA 0603BNA 0803BNA 0804CNA 1004CNA 1005CNA 1205DNA HEATING DATA High Fire Input' 30,000 40,000 60,000 60,000 80,000 80,000 100,000 100,000 120,000 High Fire Output' 28,800 38,400 57,600 57,600 76,800 76,800 96,000 96,000 115,200 Low-Fire Input' 21,000 28,000 42,000 42,000 56,000 56,000 70,000 70,000 84,000 Low-Fire Output' 20,160 26,880 40,320 40,320 53,760 53,760 67,200 67,200 80,640 AFUE2 96 96 96 96 96 96 96 96 96 Temp.Rise Range(°F) 20-50 20-50 30-60 35-65 35-65 25-55 35-65 35-65 35-65 Vent Diameter3 2"-3" 2"-3" 2"-3" 2"-3" 2"-3" 2"-3" 2"-3" 2"-3" 2"-3" No.of Burners 2 2 3 3 4 4 5 5 6 CIRCULATOR BLOWER Available AC@0.5"ESP 1.5-2 1.5-3 1.5-3 1.5-3 1.5-3 2.5-4 1.5-4 3-5 3-5 Size (DxW) 11"x6" 11"x6" 11"x6" 11"x8" 11"x8" 11"x10" 11"x10" 11"x10" 11"x11" Horsepower @ 1075 RPM 1/2 1/2 1/2 1/2 1/2 3/4 1 1 1 Speed 9 9 9 9 9 9 9 9 9 (1)16 x 25 (1)16 x 25 (1)16 x 25 (1)16 x 25 (1)16 x 25 (1)16 x 25 (1)16 x 25 (1)20 x 25 (1)20 x 25 FILTER SIZE INZ (side)or (side)or (side)or side or (bottom) (bottom) ( )(QTY) (1)14 x 25 (1)14 x 25 (1)14 x 25 ( (side or (side or (side or or(2)16 x or(2)16 x (bottom) (bottom) (bottom) bottom) bottom) bottom) bottom) 25(side) 25(side) ELECTRICAL DATA Min.Circuit Ampacity4 8.6 8.6 8.6 8 8 11.6 13.3 13.3 13.3 Max.Overcurrent(amps)5 15 15 15 15 15 15 20 20 20 SHIPPING WEIGHT(LBS) 106 106 110 115 118 123 140 140 154 • ' Natural Gas BTU/h 2 DOE AFUE based upon Isolated Combustion System(ICS) 3 Installer must supply one or two PVC pipes:one for combustion air(optional)and one for the flue outlet(required).Vent pipe must be either 2"or 3"in diameter, depending upon furnace input,number of elbows,length of run and installation(1 or 2 pipes).The optional Combustion Air Pipe is dependent on installation/ code requirements and must be 2"or 3"diameter PVC. • Minimum Circuit Ampacity=(1.25 x Circulator Blower Amps)+ID Blower amps.Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. 5 Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size.May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • All furnaces are manufactured for use on 115 VAC,60 Hz,single-phase electrical supply. • Gas Service Connection Yz"FPT • Important:Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. • For bottom return:Failure to unfold flanges may reduce airflow by up to 18%.This could result in performance and noise issues. • For servicing or cleaning,a 24"front clearance is required.Unit connections(electrical,flue and drain)may necessitate greater clearances than the minimum clearances listed above.In all cases,accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. • SS-GM9C96 www.goodmanmfg.com 3 r + • DIMENSIONS Air Air Discharge Discharge 28'/. F—A—NJ 6% -► 2% B f—% 6% f i . Air PipeIntak 2% C I. t1'%e 2" e Z 19% e Left-Side Forn Alternatet map Vent/Flue Pipe Alternate Drain Trap Air IntakeerDi Pipe le 2"PVC Vent/Flue 2 Exterior Holes 3"OD Hole Location v High-Voltage b Right-Side r st • Electrical Outlet ��r Drain Trap ( 1 j Exterior Holes (• 1 Standard High-Voltage • Gas Supply Electrical Outlet Location Alternate • Gas Supply • t 1 • I 34% O t 1 •V 26% I C 24% 23 23 19% 21% 19% 14 A I9Y. 5 Ij G 5 1T�. . ll�l f 1 I � - LEFT SIDE VIEW III f-1'/e FRONT VIEW ;HI % ix, RIGHT SIDE VIEW Low-voltage .1—2% Electrical Outlet Law-Voltage 2% 2% ..1—22% 'f D i' Elec ow-Outlet •—1'/ Unfolded Flanges Condensate Drain 22 —23 Trap Exterior 'F- E—� Unfolded Flanges Connection Folded Flanges 23% -► (Right or LeR Side) Folded Flanges '/a PVC AIR AIR DISCHARGE RETURN MODEL A B C D E GM9C960303ANA 14" 121/2" 101/2' 8%" 101/2' GM9C960403ANA 14" 121/2" 10%" 8%" 10Ys" GM9C960603ANA 14" 12%" 10% 8%" 101/2' GM9C960603BNA 17W' 16" 131/2" 121/2" 13%" GM9C960803BNA 171/2' 16" 13%" 121/2" 13%" GM9C960804CNA 21" 19%" 17%' 16" 171/2" GM9C961004CNA 21" 19%" 17%" 16" 17%" GM9C961005CNA 21" 19%" 17%' 16" 171/2" GM9C961205DNA 24% 23" 20%" 19%" 20%" MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS POSITION SIDES REAR FRONT 1 BOTTOM FLUE TOP Upflow 0" 0" 3" C 0" 1" Horizontal 6" 0" 3" C 0" 6" C=If placed on combustible floor,the floor MUST be wood ONLY. 4 www.goodmanmfg.com SS-GM9C96 GM9C LOW STAGE COOLING AIRFLOW DATA LOW STAGE COOLING AIFLOW THER- EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN) MODEL MOSTAT TAP# 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CALL CFM CFM CFM CFM CFM CFM CFM CFM F01 753 708 663 616 568 513 470 423 F02 915 883 845 809 773 730 690 650 F03 529 518 461 394 343 288 223 N/A F04^ 880 843 807 768 723 683 643 590 *M9C96 Y/Y1 F05 1055 1022 990 959 930 891 858 825 0303AN303AN F06 1101 1072 1040 1010 980 949 918 881 F07 1190 1162 1134 1104 1077 1042 1013 982 F08 1183 1157 1130 1103 1077 1047 1018 988 F09 1229 1206 1178 1153 1128 1100 1070 1042 F01 733 691 650 602 553 498 448 402 F02 1051 1024 996 966 935 907 868 836 F03 665 620 570 517 462 407 359 309 F04^ 915 881 846 814 780 737 695 652 *M9C96 Y/Y1 F05 1138 1114 1092 1064 1035 1006 977 947 0403AN403AN F06 887 855 823 790 751 705 666 608 F07 1189 1163 1138 1111 1085 1059 1032 1001 F08 1266 1243 1218 1197 1172 1148 1123 1099 F09 1342 1324 1305 1280 1263 1239 1216 1193 F01 900 867 830 798 758 718 682 645 F02 1292 1272 1248 1227 1206 1184 1162 1137 F03 688 649 603 551 499 447 405 359 F04^ 866 830 797 759 717 675 634 591 *M9C96 Y/Y1 F05 1223 1195 1176 1149 1124 1101 1074 1047 0603AN F06 1037 1004 975 950 921 886 853 823 F07 1079 1053 1025 1000 970 941 911 873 F08 1128 1099 1075 1050 1022 993 965 937 F09 1171 1148 1124 1096 1070 1045 1017 988 F01 914 864 815 762 704 654 604 560 F02 1121 1083 1041 996 953 906 861 818 F03 758 696 636 572 512 460 412 N/A FO4^ 960 917 864 812 764 708 661 614 *M9C96 Y/Y1 F05 1164 1123 1084 1042 1003 960 920 871 06038N F06 1219 1180 1141 1102 1062 1020 978 940 F07 1273 1240 1207 1171 1128 1089 1051 1012 F08 1307 1270 1235 1198 1160 1122 1083 1043 F09 1427 1390 1362 1327 1297 1260 1224 1193 FO1 1205 1169 1131 1091 1053 1014 974 934 F02 1415 1385 1355 1322 1291 1255 1219 1186 F03 696 635 568 500 442 390 336 255 F04^ 1152 1112 1076 1035 996 954 916 868 *M9C96 Y/Y1 F05 1321 1287 1251 1217 1181 1146 1112 1072 08038N . F06 901 851 801 746 690 638 587 543 F07 1112 1076 1032 992 949 905 858 819 F08 1290 1252 1 1215 1182 1143 1107 1071 1032 F09 1471 1440 1409 1377 1347 1314 1283 1247 SS-GM9C96 www.goodmanmfg.com 5 , , • t GM9C LOW STAGE COOLING AIRFLOW DATA (CONT.) LOW STAGE COOLING AIFLOW THER- EXTERNAL S14TIC PRESSURE,(INCHES WATER COLUMN) MODEL MOSTAT TAP# 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CALL CFM CFM CFM CFM CFM CFM CFM CFM F01 1289 1234 1180 1122 1058 991 917 840 F02 1836 1784 1741 1703 1664 1628 1585 1537 F03 1297 1246 1199 1142 1083 1020 •949 872 F04^ 1194 1137 1079 1014 948 873 792 712 *M9C96 Y/Y1 FO5 1748 1696 1650 1612 1574 1526 1478 1428 0804CN F06 1451 1399 1354 1309 1256 1200 1142 1077 F07 1587 1534 1489 1445 1406 1354 1298 1244 F08 1683 1633 1589 1546 1502 1460 1406 1355 F09 1919 1890 1846 1807 1771 1735 1694 1650 F01 1475 1421 1369 1314 1260 1207 1152 1097 F02 1791 1741 1699 1652 1609 1561 1513 1465 F03 924 846 767 684 606 529 463 398 F04^ 1259 1197 1138 1074 1015 947 885 821 *M9C96 Y/Y1 F05 1710 1660 1613 1583 1517 1470 1421 1374 1004CN F06 1592 1536 1486 1436 1383 1331 1281 1233 F07 1627 1574 1524 1474 1423 1370 1320 1271 F08 1921 1879 1840 1791 1751 1705 1656 1610 F09 2026 1981 1929 1901 1858 1819 1773 1733 FO1 1259 1197 1138 1074 1015 947 885 821 F02 1791 1741 1699 1652 1609 1561 1513 1465 F03 1176 1108 1044 980 913 845 779 718 F04^ 1347 1286 1231 1172 1115 1055 995 933 *M9C96 Y/Y1 F05 1921 1879 1840 1791 1751 1705 1656 1610 1005CN F06 1446 1404 1335 1280 1226 1171 1117 1062 F07 1618 1567 1510 1460 1413 1364 1312 1262 F08 2009 1964 1918 1886 1852 1811 1759 1722 F09 2161 2122 2084 2048 2010 1973 1940 1914 FO1 1766 1712 1666 1612 1558 1506 1450 1395 F02 2205 2157 2110 2064 2021 1974 1925 1879 F03 1118 1035 952 860 750 663 590 519 F04^ 1684 1620 1561 1499 1438 1378 1318 1259 *M9C96 Y/Y1 F05 2031 1981 1933 1901 1850 1799 1750 1702 1205DN F06 1220 1145 1070 995 952 907 811 725 F07 1357 1311 1243 1175 1107 1021 932 861 F08 1906 1877 1828 1778 1726 1674 1622 1568 F09 2454 2396 2347 2296 2250 2202 2157 2113 NOTES • A DEFAULT SPEED • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs,about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. 6 www.goodmanmfg.com SS-GM9C96 GM9C HIGH STAGE COOLING AIRFLOW DATA HIGH STAGE COOLING AIFLOW THER- EXTERNAL S W TIC PRESSURE,(INCHES WATER COLUMN) MODEL MOSTAT TAP# 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CALL CFM CFM CFM CFM CFM CFM CFM CFM FO1 753 708 663 616 568 513 470 423 F02 915 883 845 809 773 730 690 650 F03 529 518 461 394 343 288 223 N/A F04 880 843 807 768 723 683 643 590 *M 9C96 Y2 F05^ 1055 1022 990 959 930 891 858 825 0303AN F06 1101 1072 1040 1010 980 949 918 881 F07 1190 1162 1134 1104 1077 1042 1013 982 F08 1183 1157 1130 1103 1077 1047 1018 988 F09 1229 1206 1178 1153 1128 1100 1070 1042 FO1 733 691 650 602 553 498 448 402 F02 1051 1024 996 966 935 907 868 836 F03 665 620 570 517 462 407 359 309 F04 915 881 846 814 780 737 695 652 *M 9C96 Y2 F05^ 1138 1114 1092 1064 1035 1006 977 947 0403AN F06 887 855 823 790 751 705 666 608 F07 1189 1163 1138 1111 1085 1059 1032 1001 F08 1266 1243 1218 1197 1172 1148 1123 1099 F09 1342 1324 1305 1280 1263 1239 1216 1193 FO1 900 867 830 798 758 718 682 645 F02 1292 1272 1248 1227 1206 1184 1162 1137 F03 688 649 603 551 499 447 405 359 F04 866 830 797 759 717 675 634 591 *M 9C96 Y2 F05^ 1223 1195 1176 1149 1124 1101 1074 1047 0603AN F06 1037 1004 975 950 921 886 853 823 F07 1079 1053 1025 1000 970 941 911 873 F08 1128 1099 1075 1050 1022 993 965 937 F09 1171 1148 1124 1096 1070 1045 1017 988 FO1 914 864 815 762 704 654 604 560 F02 1121 1083 1041 996 953 906 861 818 F03 758 696 636 572 512 460 412 N/A F04 960 917 864 812 764 708 661 614 *M 9C96 Y2 F05^ 1164 1123 1084 1042 1003 960 920 871 0603BN F06 1219 1180 1141 1102 1062 1020 978 940 F07 1273 1240 1207 1171 1128 1089 1051 1012 F08 1307 1270 1235 1198 1160 1122 1083 1043 F09 1427 1390 1362 1327 1297 1260 1224 1193 F01 1205 1169 1131 1091 1053 1014 974 934 F02 1415 1385 1355 1322 1291 1255 1219 1186 F03 696 635 568 500 442 390 336 255 F04 1152 1112 1076 1035 996 954 916 868 *M 9C96 Y2 F05" 1321 1287 1251 1217 1181 1146 1112 1072 0803BN F06 901 851 801 746 690 638 587 543 F07 1112 1076 1032 992 949 905 858 819 F08 1290 1252 1215 1182 1143 1107 1071 1032 F09 1471 1440 1409 1377 1347 1314 1283 1247 SS-GM9C96 www.goodmanmfg.com 7 GM9C HIGH STAGE COOLING AIRFLOW DATA (CONT.) HIGH STAGE COOLING AIFLOW THER- EXTERNAL S74TIC PRESSURE,(INCHES WATER COLUMN) MODEL MOSTAT TAP 4 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CALL CFM CFM CFM CFM CFM CFM CFM CFM F01 1289 1234 1180 1122 1058 991 917 840 F02 1836 1784 1741 1703 1664 1628 1585 1537 F03 1297 1246 1199 1142 1083 1020 949 872 F04 1194 1137 1079 1014 948 873 792 712 *M9C96 Y2 F05^ 1748 1696 1650 1612 1574 1526 1478 1428 0804CN F06 1451 1399 1354 1309 1256 1200 1142 1077 F07 1587 1534 1489 1445 1406 1354 1298 1244 F08 1683 1633 1589 1546 1502 1460 1406 1355 F09 1919 1890 1846 1807 1771 1735 1694 1650 F01 1475 1421 1369 1314 1260 1207 1152 1097 F02 1791 1741 1699 1652 1609 1561 1513 1465 F03 924 846 , 767 684 606 529 463 398 F04 1259 1197 1138 1074 1015 947 885 821 *M 9C96 Y2 F05^ 1710 1660 1613 1583 1517 1470 1421 1374 1004CN F06 1592 1536 1486 1436 1383 1331 1281 1233 F07 1627 1574 1524 1474 1423 1370 1320 1271 F08 1921 1879 1840 1791 1751 1705 1656 1610 F09 2026 1981 1929 1901 1858 1819 1773 1733 FO1 1259 1197 1138 1074 1015 947 885 821 F02 1791 1741 1699 1652 1609 1561 1513 1465 F03 1176 1108 1044 980 913 845 779 718 F04 1347 1286 1231 1172 1115 1055 995 933 *M 9C96 Y2 F05^ 1921 1879 1840 1791 1751 1705 1656 1610 1005CN F06 1446 1404 1335 1280 1226 1171 1117 1062 F07 1618 1567 1510 1460 1413 1364 1312 1262 F08 2009 1964 1918 1886 1852 1811 1759 1722 F09 2161 2122 2084 2048 2010 1973 1940 1914 FO1 1766 1712 1666 1612 1558 1506 1450 1395 F02 2205 2157 2110 2064 2021 1974 1925 1879 F03 1118 1035 952 860 750 1 663 590 519 F04 1684 1620 1561 1499 1438 1378 1318 1259 *M9C96 Y2 F05^ 2031 1981 1933 1901 1850 1799 1750 1702 1205DN F06 1220 1145 1070 995 952 907 811 725 F07 1357 1311 1243 1175 1107 1021 932 861 F08 1906 1877 1828 1778 1726 1674 1622 1568 F09 2454 2396 2347 2296 2250 i 2202 2157 2113 NOTES • A DEFAULT SPEED • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs,about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. 8 www.goodmanmfg.com SS-GM9C96 GM9C CIRCULATION AIRFLOW DATA CIRCULATION AIFLOW THER- EXTERNAL SWTIC PRESSURE,(INCHES WATER COLUMN) MODEL MOSTAT TAP# 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CALL CFM CFM CFM CFM CFM CFM CFM CFM FO1 753 708 663 616 568 513 470 423 F02 915 883 845 809 773 730 690 650 F03 529 518 461 394 343 288 223 N/A F04 880 843 807 768 723 683 643 590 *M9C96 G F05 1055 1022 990 959 930 891 858 825 0303AN F06 1101 1072 1040 1010 980 949 918 881 F07 1190 1162 1134 1104 1077 1042 1013 982 F08 1183 1157 1130 1103 1077 1047 1018 988 F09 1229 1206 1178 1153 1128 1100 1070 1042 FO1 733 691 650 602 553 498 448 402 F02 1051 1024 996 966 935 907 868 836 F03 665 620 570 517 462 407 359 309 F04 915 881 846 814 780 737 695 652 *M9C96 G F05 1138 1114 1092 1064 1035 1006 977 947 0403AN F06 887 855 823 790 751 705 666 608 F07 1189 1163 1138 1111 1085 1059 1032 1001 F08 1266 1243 1218 1197 1172 1148 1123 1099 F09 1342 1324 1305 1280 1263 1239 1216 1193 FO1 900 867 830 798 758 718 682 645 F02 1292 1272 1248 1227 1206 1184 1162 1137 F03 688 649 603 551 499 447 405 359 F04 866 830 797 759 717 675 634 591 *M9C96 G F05 1223 1195 1176 1149 1124 1101 1074 1047 0603AN F06 1037 1004 975 950 921 886 853 823 F07 1079 1053 1025 1000 970 941 911 873 F08 1128 1099 1075 1050 1022 993 965 937 F09 1171 1148 1124 1096 1070 1045 1017 988 F01 914 864 815 762 704 654 604 560 F02 1121 1083 1041 996 953 906 861 818 F03 758 696 636 572 512 460 412 N/A F04 960 917 864 812 764 708 661 614 *M9C96 G F05 1164 1123 1084 1042 1003 960 920 871 0603BN F06 1219 1180 1141 1102 1062 1020 978 940 F07 1273 1240 1207 1171 1128 1089 1051 1012 F08 1307 1270 1235 1198 1160 1122 1083 1043 F09 1427 1390 1362 1327 1297 1260 1224 1193 FO1 1205 1169 1131 1091 1053 1014 974 934 F02 1415 1385 1355 1322 1291 1255 1219 1186 F03 696 635 568 500 442 390 336 255 F04 1152 1112 1076 1035 996 954 916 • 868 * G F05 1321 1287 1251 1217 1181 1146 1112 1072 0803BN803BN F06 901 851 801 746 690 638 587 543 F07 1112 1076 1032 992 949 905 858 819 F08 1290 1252 1215 1182 1143 1107 1071 1032 F09 1471 1440 1409 1377 1347 1314 1283 1247 SS-GM9C96 www.goodmanmfg.com 9 GM9C CIRCULATION AIRFLOW DATA(CONT.) CIRCULATION AIFIEOW THER- EXTERNAL S74TIC PRESSURE,(INCHES WATER COLUMN) MODEL MOSTAT TAP# 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CALL CFM CFM CFM CFM CFM CFM CFM CFM FO1 1289 1234 1180 1122 1058 991 917 840 F02 1836 1784 1741 1703 1664 1628 1585 1537 F03 1297 1246 1199 1142 1083 1020 949 872 F04 1194 1137 1079 1014 948 873 792 712 *M9C96 G F05 1748 1696 1650 1612 1574 1526 1478 1428 0804CN F06 1451 1399 1354 1309 1256 1200 1142 1077 F07 1587 1534 1489 1445 1406 1354 1298 1244 F08 1683 1633 1589 1546 1502 1460 1406 1355 F09 1919 1890 1846 1807 1771 1735 1694 1650 F01 1475 1421 1369 1314 1260 1207 1152 1097 F02 1791 1741 1699 1652 1609 1561 1513 1465 F03 ' 924 846 767 684 606 529 463 398 F04 1259 1197 1138 1074 1015 947 885 821 *M9C96 G F05 1710 1660 1613 1583 1517 1470 1421 1374 1004CN F06 1592 1536 1486 1436 1383 1331 1281 1233 F07 1627 1574 1524 1474 1423 1370 1320 1271 F08 1921 1879 1840 1791 1751 1705 1656 1610 F09 2026 - 1981 1929 1901 1858 1819 1773 1733 FO1 1259 1197 1138 1074 1015 947 885 821 F02 1791 1741 1699 1652 1609 1561 1513 1465 F03 1176 1108 1044 980 913 845 779 718 F04 1347 1286 1231 1172 1115 1055 995 933 *M9C96 G F05 1921 1879 1840 1791 1751 1705 1656 1610 1005CN F06 1446 1404 1335 1280 1226 1171 1117 1062 F07 1618 1567 1510 1460 1413 1364 1312 1262 F08 2009 1964 1918 1886 1852 1811 1759 1722 F09 2161 2122 2084 2048 2010 1973 1940 1914 F01 1766 1712 1666 1612 1558 1506 1450 1395 ' F02 2205 2157 2110 2064 2021 1974 1925 1879 F03 1118 1035 952 860 750 663 590 519 F04 1684 1620 1561 1499 1438 1378 1318 1259 *M9C96 G F05 2031 1981 1933 1901 1850 1799 1750 1702 1205 D N F06 1220 1145 1070 995 952 907 811 725 F07 1357 1311 1243 1175 1107 1021 932 861 F08 1906 1877 1828 1778 1726 1674 1622 1568 F09 2454 2396 2347 2296 2250 2202 2157 2113 NOTES • ^DEFAULT SPEED • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs,about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. 10 www.goodmanmfg.com SS-GM9C96 GM9C HEATING AIRFLOW DATA HEATING AIFLOW THER- EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN) TEMP TEMP MODEL MOSTAT TAP It 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 RANGE RANGE CALL LOW HIGH CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM FO1^ 753 25 708 26 663 28 616 30 568 33 513 470 423 W/W1 F03^^ 529 N/A 518 N/A 461 N/A 394 N/A 343 N/A 288 223 N/A *M9C80 F04 880 21 843 22 807 23 768 24 723 26 683 643 590 * 20-50 20-50 0403A F02^ 915 29 883 30 845 32 809 33 773 34 730 690 650 W2 F04 880 30 843 32 807 33 768 35 723 37 683 643 590 F05 1055 25 1022 26 990 27 959 28 930 29 891 858 825 F01^ 733 34 691 36 650 38 602 41 553 45 498 448 402 W/W1 F03^^ 665 N/A 620 N/A 570 N/A 517 N/A 462 N/A 407 359 309 *M9C80 F04 915 27 881 28 846 29 814 31 780 32 737 695 652 0603A* F02^ 1051 34 1024 35 996 36 966 37 935 38 907 868 836 20-50 20-50 W2 F04 915 39 881 40 846 42 . 814 44 780 46 737 695 652 F05 1138 31 1114 32 1092 33 1064 33 1035 34 1006 977 947 FO1^ 900 40 867 42 830 44 798 46 758 48 718 682 645 W/W1 F03^^ 688 N/A 649 N/A 603 N/A 551 N/A 499 N/A 447 405 359 *M9C80 F04 866 42 830 44 797 46 759 48 717 50 675 634 591 * 20-50 30-60 0603E F02^ 1292 41 1272 42 1248 43 1227 43 1206 44 1184 1162 1137 W2 F04^^ 866 N/A 830 N/A 797 N/A 759 N/A 717 N/A 675 634 591 F05 1223 44 1195 45 1176 45 1149 46 1124 47 1101 1074 1047 F01^ 914 41 864 43 815 46 762 49 704 53 654 604 560 W/W1 F03^^ 758 N/A 696 N/A 636 N/A 572 N/A 512 N/A 460 412 N/A *M9C80 F04 960 39 917 41 864 43 812 46 764 49 708 661 614 0803B* F02^ 1121 48 1083 49 1041 51 996 54 953 56 906 861 818 25-55 35-65 W2 F04^^ 960 N/A 917 N/A 864 N/A 812 N/A 764. N/A 708 661 614 F05 1164 46 1123 47 1084 49 1042 51 1003 53 960 920 871 F01" 1205 41 1169 43 1131 44 1091 46 1053 47 1014 974 934 W/W1 F03^^ 696 N/A 635 N/A 568 N/A 500 N/A 442 N/A 390 336 255 *M9C80 F04 1152 43 1112 45 1076 46 1035 48 996 50 954 916 868 * 35-65 35-65 0804B F02" 1415 50 1385 51 1355 52 1322 54 1291 55 1255 1219 1186 W2 F04^^ 1152 N/A 1112 N/A 1076 N/A 1035 N/A 996 N/A 954 916 868 F05 1321 54 1287 55 1251 57 1217 58 1181 60 1146 1112 1072 F01^ 1289 39 1234 40 1180 42 1122 44 1058 47 991 917 840 W/W1 F03 1297 38 1246 40 1199 42 1142 44 1083 46 1020 949 872 *M9C80 F04 1194 42 1137 44 1079 46 1014 49 948 52 873 792 712 25-55 25-55 0804C F02" 1836 39 1784 40 1741 41 1703 42 1664 43 1628 1585 1537 W2 F04^^ 1194 N/A 1137 N/A 1079 N/A 1014 N/A 948 N/A 873 792 712 F05 1748 41 1696 42 1650 43 1612 44 1574 45 1526 1478 1428 SS-GM9C96 www.goodmanmfg.com 11 • GM9C HEATING AIRFLOW DATA (CONT.) HEATING AIFLOW THER- EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN) TEMP TEMP MODEL MOSTAT TAP# 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 RANGE RANGE CALL CFM I RISE CFM I RISE CFM I RISE CFM I RISE CFM I RISE CFM CFM CFM LOW HIGH F01" 1475 42 1421 • 44 1369 45 1314 47 1260 49 1207 1152 1097 W/W1 F03^^ 924 N/A 846 N/A 767 N/A 684 N/A 606 N/A 529 463 398 *M9C80 F04 1259 49 1197 52 1138 55 1074 58 1015 61 947 885 821 35-65 35-65 0805C F02" 1791 50 1741 51 1699 52 1652 54 1609 55 1561 1513 1465 W2 F04^^ 1259 N/A 1197 N/A 1138 N/A 1074 N/A 1015 N/A 947 885 821 F05 1710 52 1660 54 1613 55 1583 56 1517 59 1470 1421 1374 F01" 1259 49 1197 52 1138 55 1074 58 1015 61 947 885 821 W/W1 F03^^ 1176 N/A 1108 N/A 1044 N/A 980 N/A 913 N/A 845 779 718 *M9C80 F04 1347 46 1286 48 1231 51 1172 53 1115 56 1055 995 933 * 35-65 35-65 08050 F02" 1791 50 1741 51 1699 52 1652 54 1609 55 1561 1513 1465 W2 F04^^ 1347 N/A 1286 N/A 1231 N/A 1172 N/A 1115 N/A 1055 995 933 F05 1921 46 1879 47 1840 48 1791 50 1751 51 1705 1656 1610 F01" 1766 42 1712 44 1666 45 1612 46 1558 48 1506 1450 1395 W/W1 F03^^ 1118 N/A 1035 N/A 952 N/A 860 N/A 750 N/A 663 590 519 *M9C80 F04 1684 44 1620 46 1561 48 1499 50 1438 52 1378 1318 1259 35-65 35-65 1004C* F02^ 2205 48 2157 49 2110 51 2064 52 2021 53 1974 1925 1879 W2 F04"" 1684 N/A 1620 N/A 1561 N/A 1499 N/A 1438 N/A 1378 1318 1259 F05 2031 53 1981 54 1933 55 1901 56 1850 58 1799 1750 1702 NOTES • ^DEFAULTSPEED • All furnaces ship as high speed for cooling.Installer must adjust blower speed as needed. • For most jobs,about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. • 12 www.goodmanmfg.com SS-GM9C96 N N G) g 9n BTU OUTPUT VS. TEMPERATURE RISE CHART rn 100 _Hu tit ' IIII IIII IIII IIII IIII •iiii iiii tit iiii 1 ii fill 1 II III ! ii 1 ! III II iiii III 1111 1111 1111 1111 = 600 CFM = :: ii 700 800 _ / 900 — 70 _ woo _ N = 'Iwo - 71200 - o t 60 — _ d Q = 1400 cc - / LU — 1600 1800 / = 2000 = 40 _ 2200 2400 CFM 30 _ m FORMULAS _ m -- BTU/h Output=CFM x 1.08 x Rise = C 20 -// BTU/H Output m ''/ Rise= = Z 4,-- CFMx1.08 _ - F" 10 -iiti iiii ! III mil till IIII iiii lilt till liii lilt Hit lilt lilt lilt IIII a z 30 40 50 60 70 80 90 100 110 120 130 140 150 m z w OUTPUT BTU/H X 1,000 y WIRING DIAGRAM — GM9C96******AA adr r, TC 5- •GND 1 5 VAC/10/60 HZ I Z r, POWER SUPPLY WITH ID SLOWER T WOSTAGE PRESSURE L, OVERCURRENT HOT SWITCH ASSEMBLY Z PROTECTION DEVICE O SURFACE ` L a O rB WARNING:DISCONNECT IGNITER OR— HIGH FIRE x BK II''ll,, 4 POWER BEFORE r.- LOW FIRE e—c PRESSURE SWITCH 1 �N SERVICING.WIRING PRESSURE '0•• O WJt TO UNIT MUST BE SWITCH — — DISCONNECT PROPERLY POLARIZED 2 CIRCUIT AND GROUNDED. I CONNECTOR —OR TO 115VAC/10/60 HZ POWER SUPPLY WITH 3 HI 3 PU OVERCURRENT PROTECTION DEVICE 1 U FLAME WARNING: L GND I TWO STAGE C 2 GY �- Y a SENSOR DISCONNECT POWER rl GAS VALVE LO_L-BR-I BEFORE SERVICING. (WHITE RODGERS) I WIRING TO UNIT ` MUST BE PROPERLY S .. POLARIZED AND ' SOME UNITS MAY HAVE • GROUNDED. DISCONNECT 0.TS I''11 ROLL^OUT T SWITCH [��,�� 1(J O Q P �/ PK '( C / c f r' ri G Z' / �/ DOOR LI SWITCH 1 / I--ILJ C AUTO RESET PRIMARY JUNCTION BOX _ LIMIT CONTROL RD .c 2 O GND INDUCED INDOOR t^ N WH DRAFT AIR 2 RD CIRCUWTOR• - a BLOWER BLYm Di Op )O 1 BK c ONO = E BUJRNERCOUPARIC\ �O cc LINE I C BLOWER COMPARTMENT GND ® 3 • N Z AUTO RESET PID/W� /,� HUM-OUT O. AUXIIMBY 1/ L A L v HUN• �_� '® g no 2 p_ G C DMRCONTROL \V`Ij•/F/�YL 6\Vt�+//p PK Htn.121REII y 8$ _C• •ELECTRONIC 0 u IL�I1NJr •a`CL- ® ; O IND HI O tD JEC OO �� • . 'D •�'® O I fo —• ' m O I HOT SURFACE _ ' SE I FSA IGNITER -O O O EIiEi;EiiEiiit;t;Eii FLAME SENSOR - N �y9 m L NE 115 VAC NEUTRAL• - iiirz r3 Y RANSTORM•• • LL. R --' 2A VAC• WV O. B_e(.:)�`®Y(pl TH IS)� A� C I • 2111 OCP10ffl� N— F® O { 13 MANUAL 1 SETgOLLOUTLUA'S•ITCHp a 0 ES) AUTO RESET y RI. RD _ TO AUTO RESET AUX LIMIT PRIMARYLIMR DT)>. BK OF M �VOC I� P. E RD R9L Lei, T. `s LOW FIRE • •G LA O , � s l PSt S ,PRESS.SWITCH Of N E1 s � a t M�■• FlRE READ CODES FROM LEFT TO RIGHT HU(B) PRESS.SWITCM C �� 1r Z INTEGRATED CONTROL MODULE —^ H L1 Q efed $ 2 O TWO' 5 �2.2 I.1 I.1 I!1��l IN 1�1 IC)�© m GAS '<I.,:I��MII I<i) VALVE a li►1 W L•L I.1 11d 1.1 D >N \ W2 W/WiRG CV/V1 Y2 O O \.1 11 • 6R.� ECM MTR \ 4II�Q—�— W ORQ!�� HARNESS o >Y' WATOR 3 C ' 1 BLWRGND ¢ 0 �. BK AoA I R1T INTEGRATED CONTROL MODULE v GND T 9 II-Af-�IAI I NOTES)ET HEAT ANRCIPATOR ON ROM THERMOSTAT AT O.)ANPS C OD 2.MANUFACTURERS SPECIFED REPLACEMENT PARTS MUST BE USED 0 Or Di BLOWER WHEN SERVICING. CIRCULATOR BLOWER I CHASSIS COMPARTMENT 3.IF ANY OF THE ORIGWAL WIRERS SUPPLIED WITH THE FURNACE P. C GROUND DOOR SWITCH MUST BE REPLACED R MUST BE REPLACED WITH WIRING MATERIAL (OPEN WHEN HAVING TORSORANRE RATING OFATLEAST f05 C.USE COPPER U-� 0 DOOR OPE CONDUCTORS ONLY. 5 . NO 4.ANIT C DESMPNENRV GROUNDED AND CONFORM TO NEC. 3 AND LOCALLTHE LA Seven Segment Display S.DEPRESS ITCH FOR FAULMORE S.THAN 2 ECOND WHILETO IN RECENT. N Y Status Seg# Seg# Seg# DEPRESS IPUMSORETHAN25ECOND$YMBEWSTANDBV Internal Faults or IRO Loss E E E m o `o Lockout Due to Excessive Retries Recycle E E 0 COLOR CODES: EQUIPMENT GND /*/ c Low Stage Pressure Switch Stuck Closed E E 1 BR BROWN PK PINK FIELD GND §w al'S Low Stage pressure Switch Open E E 2 WH WHITE FIELD SPUCE a_ Open High Limit Switch E E 3 BL BLUE SWITCH(TEMP.) Flame Detected When no Flame Should be E E 4 GY GRAY IGNITER zTT1v RD RED Open Fuse E E 5 YL YELLOW SWITCH(PRESS.) Low Flame Signal E E 6 ' oR ORANGE OVERCURRENT Ignitor Relay Fault E E L PU PURPLE PROT.DEVICE High Stage Pressure Switch Stuck Closed E E 8 GN GREEN JUNCTION High Stage Pressure Switch Open E E 9 BK BLACK _6_TERMINAL Line Polarity or Grounding Error E E A 4 INTERNAL Internal Gas Valve Error E E b INTEGRATED CONTROL — External Gas Valve Error E E C PLUG CONNECTION-1 I (- Open Rollout Switch E 1 1 LOW VOLTAGE(24V)— IgnHorOpen E E N N LOW VOLTAGE FIELD — — Inducer Relay Error E E I piM1 HI VOLTAGE(115V) TWIN Error E E H GROUNDING ERROR E 1 0 S140FS2639-A HI VOLTAGE FIELD 14 www.goodmanmfg.com SS-GM9C96 ACCESSORIES MODEL DESCRIPTION GM9C96 GM9C96 GM9C96 GM9C96 GM9C96 0303ANA 0403ANA 0603ANA 0603BNA 0803BNA 72950 Concentric Vent Kit(2") V V V V V 72951 Concentric Vent Kit(3") V V V V V RF000142 Drain Kit-Horizontal Left Vertical Flue V V V V V EFRO2 External Filter Rack with 16"x25" V V V V V Permanent Filter 0170K00000S Flush Mount Vent Kit-3"or 2" V V V V V 0170K00001S Flush Mount Vent Kit-2" V V V V V AFE18-60A Fossil Fuel(Dual Fuel)Kit V V V V V HASFK High-Altitude Natural Gas Kit N/A TBD TBD HASFK-1 HASFK-2 HASFK High-Altitude LP Gas Kit N/A TBD TBD HASFK-1 HASFK-2 0270F05404 Horizontal Drain Tubing Kit V V V V V LPLP03 Low LP Gas Pressure Switch V V V V V LPM-08 LP Conversion Kits --- V V V V LPM-30 LP Conversion Kit V — --- -- MODEL DESCRIPTION GM9C96 GM9C96 GM9C96 GM9C96 0804CNA 1004CNA 1005CNA 1205DNA • 72950 Concentric Vent Kit(2") V V V -- 72951 Concentric Vent Kit(3") V V V V RF000142 Drain Kit-Horizontal Left Vertical Flue V V V V EFRO2 External Filter Rack with 16"x25" V V V — Permanent Filter 0170K00000S Flush Mount Vent Kit-3"or 2" V V V V 0170K00001S Flush Mount Vent Kit-2" V V V -- AFE18-60A Fossil Fuel(Dual Fuel)Kit V V V V HASFK High-Altitude Natural Gas Kit HASFK-2 HASFK-2 HASFK-3 HASFK-3 HASFK High-Altitude LP Gas Kit HASFK-2 HASFK-2 HASFK-2 HASFK-2 0270F05404 Horizontal Drain Tubing Kit V V V V LPLP03 Low LP Gas Pressure Switch V V V V LPM-08 LP Conversion Kits V V V V LPM-30 LP Conversion Kit — — -- — SS-GM9C96 www.goodmanmfg.com 15 1 G M 9 C 9 6 Goodman° TWO-STAGE GAS FURNACE Air Conditioning&Heating HIGH-EFFICIENCY, MULTI-SPEED ECM UP TO 96%AFUE PERFORMANCE Upflow/Horizontal ,, t ' - 7 - : voli, 11 Sri y,— y —, .•. . ,V3,.. �j111 V T Y i 3O,011 ` CyF,,`, aCtq 4 1/ 14 h SYd sq'' t' k •I rt '` at' 1 t'a • ess ._,A _, .. . , . , , ,.,..... F 8 34" r t . i• o i ''' ql' ‘' '. . c L 000dman q . l; DESIGNED ENGINEERED •-- - At Goodman,we believe in American dependability.Units are ASSEMBLED designed,engineered and assembled in the U.S.A. IN THE USA. )1111 ) Goodman is one of the biggest names in home heating and energy-efficient home comfort. That's because Goodman lives up to its name in a big way, with time-tested energy-efficient technology, highly-durable materials and spot-on manufacturing. So, no matter where you live or whether your home is small or large, Goodman probably has a gas furnace to help keep your home warm and comfortable. Goodman is a brand you can Don't high utility bills make Taking pride in our really warm up to. you hot under the collar? company heritage. The best gas furnace is the kind you don't High heating bills burn us up, too. Our Goodman brand heating and cooling have to think or worry about.It comes on complete line of gas furnaces are priced systems are designed to provide the moment you need it and then runs to help add comfort to your budget from refreshingly affordable and energy- quietly and efficiently all winter long a local independent dealer. And that's efficient indoor comfort solutions using as needed. The Goodman GM9C96 is only the beginning.We want you to smile advanced technology. But the company loaded with features designed to provide every time you open your utility bill, so ultimately adheres to some old-fashioned outstanding performance for years to we design into our units proven energy- values too. Goodman believes in the come. We use advanced techniques and efficient technology. integrity of the American worker.That's materials so you know the cozy,even heat why Goodman brand heating and cooling you feel in every corner of your home is systems are designed, engineered and an energy-efficient warming trend that's assembled in the United States. designed to stay for many years. n Experience reliable indoor comfort for everyone tiF in your home winter after winter after winter. Goodman Air Conditioning&Heating y 3 ,-jf• r t7 Y ,— ,e,.,4, „,,, ,si - _. - - .-- .'\2. ; A LOT GOES INTO EVERY GOODMAN BRAND COMPONENT UPGRADE OFFERS GM9C96 GAS FURNACE BETTER PERFORMANCE The aluminized steel,tubular primary heat exchanger featured in Goodman The art of precision brand gas furnaces is likely the most Aluminized Steel Tubular Primary Heat Exchanger-Distinctive tubular aluminized steel construction formed using wrinkle-bend technology results in an extremely essential component in a gas furnace's durable heat exchanger.Paired with a stainless-steel secondary heat exchanger,this performance. This distinctive heat combination provides reliability,durability and efficiency. exchanger employs wrinkle-bend Two-Stage Gas Valve-Reduces energy needed during moderate demand to deliver technology which was developed to outstanding comfort and efficiency as compared to single-stage gas valves. deliver extraordinary durability and long-term reliability. Goodman gas furnaces simply work the way they're supposed to, making each one a thing of beauty. . Multi-Speed ECM Motor-Automatically adjusts airflow to match comfort needs, � reduces energy consumption and system noise as compared to single stage motors. " �� All models are FER compliant with up to nine speeds available for cooling. f Quiet,Two-Speed,Induced-Draft Blower-Provides precise control and enhanced ,;>..:_,y,,-, energy-efficient performance as compared to a natural draft furnace. -�� Durable 110-Volt Silicon Nitride Igniter-Eliminates the need for an energy-wasting jr ' pilot light. ►i- - i� 1 Self-Diagnostic Control Board-Continuously monitors the system for consistent, reliable operation,stores last diagnostic codes in memory;and indicates condition through a 3-digit,7-segment LED for quick troubleshooting. Thermally-Insulated Cabinet-The fully insulated cabinet means air leakage of less than 2%to maximize the heat transfer efficiency and lower blower noise. When your current furnace breaks, it's good to know that your local,independent Goodman brand contractor has financing options available to help defray what Thank goodness for Goodman® might be considered an emergency "--.......--- purchase for your home. 171/ .),,e .F /a ^ ) I' uu o lila oOOlnian ''.. Js _ 1 COUNT ON OUTSTANDING LIMITED WARRANTY* PROTECTION *Complete warranty details available I ® U AC REPLACEMENT I T from your local dealer or at YEAR LIMIT TDD' www.goodmanmfg.com.To receive the 10-Year Unit Replacement Limited Warranty, the Lifetime LIFETIME Heat Exchanger Limited Warranty HEAT EXCHANGER LIMITED WARRANTY' (good for as long as you own your home) and 10-Year Parts Limited 1 ® Warranty, online registration must PARTS be completed within 60 days of LIMITED installation. Online registration is YEAR WARRANTY' not required in California or Quebec. ENERGY STAR° and the ENERGY STAR mark are registered trademarks owned by the U.S.Environmental Protection Agency. ENERGY STAR products are third- party certified by an EPA-recognized Certification Body. Products that earn the ENERGYSTAR prevent greenhouse gas emissions by meeting strict energy efficiency guidelines set by the U.S.Environmental Protection Agency. PERFORMANCE The 96%AFUE rating on this gas furnace means that 96 cents UP TO of every energy dollar warms your home.The Department of 96% Energy(DOE)established the AFUE(Annual Fuel Utilization AFUE Efficiency)system to calculate the annual operating cost of residential gas furnaces. Independent, dependable, courteous, prompt, honest, highly-skilled and respectful of you and your home. That's why all the time homeowners say, "These guys are good - really good." i }Ft - 36, /i r f 1 L • -,,.;:- Why does Goodman have such a large fan base? Many of your neighbors may have discovered that a reliable and energy-efficient home comfort system doesn't have to cost a fortune. Goodman brand whole-house systems feature many of the latest and greatest money-saving technology benefits that we can offer.They are designed and engineered to run quietly and pretty much worry-free. EXTENDED SERVICE PLANS AVAILABLE For even greater peace-of-mind,ask your dealer or visit our website atwww.goodmanmfg. com for more details about Asure'TM,an affordable Parts and/or Labor Extended Service Plan for your entire Goodman brand HVAC system. Asure EXTENDED SERVICE PLAN Ask your dealer for full details. ONCE YOU CHOOSE THE GOODMAN® BRAND, YOU'LL PROBABLY BE A FAN FOR LIFE. '�r it � , 7 :.® Yr A , '`f "� '= - -A6 f -� Millions across North America are big fans already. °'4• T '' = .k "4 Once you choose a Goodman brand,you'll probably be a big fan, too. ill "1` r,41 See why others are saying, "Thank Goodness for Goodman® rZe , '` ,- r • ,r,I. Just go to www.goodmanmfg.com/reviews ComfortBridgem �• CLEANLE (COMFORT technology HVAC Communicating Control Pure. Clean. Air. ComfortBridge technology offers off-the-wall smart corn- Indoor comfort in your home is about more than just ad- municating systems capable of customizing energy-efficient justing the temperature on the thermostat. Many home- performance,use of any single-stage thermostat,and more. owners overlook the need for necessary components and systems that can improve the indoor air you breathe. "7 FILTRATION HUMIDITY CONTROL DEHUMIDIFICATION PURIFICATION VENTILATION ZONING 17i fiiff 1♦r 2019 _ DEALER DESIGN °�� ....... • YII'..� LL c2 AWARDS www.comfortbridge.com www.cleancomfort.com GOODMAN IS SOCIAL! gri Like us on Facebook! Wr Follow us on Twitter! Follow us on histogram! MI II facebook.com/GoodmanMfg twitter.com/Goodman_Mfg O instagram.com/Goodman_Mfg DAIKIN GOODMAN — A MEMBER OF DAIKIN GROUP fir Daikin Industries, Ltd. (DIL) is a global Fortune 1000 company. It is a worldwide leader for residential and commercial HVAC. DIL is engaged primarily in the development,manufacture,sale,and aftermarket support of heating,ventilation, air conditioning and refrigeration equipment, refrigerants and other chemicals,as well as oil hydraulic products.DIL is headquartered in Osaka,Japan. The company provides innovative,premium quality indoor climate management solutions to meet the changing needs of residential,commercial,and industrial customers. 0 Additional Information Canada Before purchasing this appliance, read important information about its ENER UIDE BBB. estimated annual energy consumption, yearly operating cost, or energy "El NDESSD Annual Fuel Utilization Efficiency(AFUE) efficiency rating that is available from your retailer. Gas-or Propane-fired forced-air furnace with a high efficiency motor THIS MODEL 196.1 I Goodman 90% 99% a member of DAIKIN group Our continuing commitment to quality products may mean a change in specifications without notice.©2021 Goodman Manufacturing Company,LP. www.goodmanmfg.com CB-GM9C96 08-21 ATTACHMENT F ri p••OPFRTyL/NE 15p 1� 0 z SHED �' ir o a. ,r s Q cr co u) l , -_,4Q' ai Z p; E/ . la O Nr r' O• N XISTIN r `` / 7'Av. HOUSE,/ au _ ''CI r r/ DRIVEWAY 0 1t N NOTES: • 3lei, : 1. cn 'PARKING,• ' 0 73 \ 00 m - ADDRESS: 378 QUEENSBURY AVE m QUEENSBURY,NY 12804 SITE PLAN PROpERTYClive. LOT AREA:1 ACRES PLOT SIZE:8.5"X 11' DRAWING DATE:03/31/2022 215' DRAWING SCALE:1"=40' N 297.16-1-2.2 CC-0149-2022 Ross, Jerad 378 Queensbury Ave �- New Multi-family (3unit) 2211 s.f. ' ., '�3 /`_� '..•' _ �`` , . 2 :_ :_ _=, __ r _ in i PROPER ONE 1 ij Li , i-',PR 05 '411322 ILL' ' {TOWN li (-5�EIE tile: PUll . .�pyf c y \DE-rRY al SHED X W Oa 2 / O i 0: a 6 / • i19. cr no Z Oi W Ni 0 EXISTING; T•Aere ,HOUSE so . \ � . ,1` .O' • • - - r' .DRIVEWAY �. -.34,--- '.; N NOTES: PA�KIAGrn / -%. , 23 o ADDRESS: r 378 QUEENSBURY AVE Z QUEENSBURY,NY 12804 m SITE PLAN RTy Li LOT AREA:1 ACRES PROPE PLOT SIZE:8.5"X 11" DRAWING DATE:03/31/2022 215 DRAWING SCALE:1"=40' CURB STOP '11,18, > y.5 s r". Town Botundaries LOCATION MAP REQUIRED MINIMUM SETBACKS SEPTIC TANK: PROPERTY LINE 10 FT BUILDING 10 FT WELL 50 FT STREAM 50 FT DRAINAGE SWALE 10 FT DISTRIBUTION BOX: 10 FT 20 FT 100 FT 100 FT 20 FT ABSORPTION FIELD: 10 FT 20 FT 100 FT 100 FT 20 FT O rp M NEW 44' X 59' ABSORPTION FIELD W/ INFILTRATORS, 8 LINES @ 59 FT EA 3 4 5-2 5-2 GENERAL NOTES 1) PROPOSED PROJECT: REPLACEMENT SEPTIC SYSTEM FOR AN EXISTING DEVELOPED PROPERTY. A NEW MULTI -UNIT RESIDENTIAL BUILDING IS BEING CONSTRUCTED ON THE FOOTPRINT OF A PREVIOUS STRUCTURE THAT WAS LOST IN A FIRE. SITE IS ON MUNICIPAL WATER, AN EXISTING SEPTIC SYSTEM IS LOCATED ON THE PROPERTY. 2) THERE ARE NO ADJACENT WELLS OR STRUCTURES WITHIN 500 FT OF THE SUBJECT PROPERTY. 3) CONTOURS ARE EXISTING AND WILL GENERALLY REMAIN UNLESS OTHERWISE NOTED. CONTOURS AND ELEVATIONS ARE APPROXIMATED BASED ON FIELD OBSERVATION AND THE USGS GIS BASEMAP. CONTOURS ARE NOT BASED ON AN ACTUAL FIELD SURVEY. 4) SCALE AT 22X34 SHEET SIZE - DO NOT SCALE FROM ELECTRONIC REPRODUCTIONS 5) CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS ON THIS PLAN AND REPORT DISCREPANCIES TO ENGINEER PRIOR TO CONSTRUCTION 6) CONTRACTOR TO CALL 811 DIGSAFELY NY FOR UTILITY MARKOUT PRIOR TO CONSTRUCTION 7) TEMPORARY EROSION & SEDIMENT CONTROL MEASURES, INCLUDING SILT FENCING, DURING CONSTRUCTION TO BE INSTALLED IAW NYSDEC BLUE BOOK AS REQUIRED MAP REFERENCES 1) TAX MAP, TOWN OF QUEENSBURY, WARREN COUNTY, NEW YORK, SHEET 297.16, APRIL 28, 2022 2) WARREN COUNTY GIS: VCGI, ESRI CANADA, HERE, GARMIN, INCREMENT P, USGS, EPA, USDA 3) FIELD MEASUREMENTS OBTAINED BY K. WOOD, P.E. 9-22-22 CJ• M LANDS N/F WARREN CO 297.-16-1-1.12 (1 AC) 9 -=,_ I jl�i` 54 FT I I 1 S � - :A 8 LE Tp 5 , / _TAX ��d ONIC ,L / MAP,,'D, \ �; FIELD VERIFY WATER u� LANDSN/FROSS,JERAD"J`;\` , i'/' ,, ` LINE ALIGNMENT i 297.16-1-1.2,,E i (0.20 AC) 1 O .\ t_ 0 U) LL 0 T TP-2 M vV LANDS N/F ROSS, JERAD 297.16-1-2.2 (0.45 AC) 86 FT N 340 33$ 336 --i o„ - CV _'� Lo Y ti O I— d 07 W _I 000 Co H W O> co� W LLI 0 w m z z O z Q LLJ } L1J Q z w cc aaob w >- (AOcsW u = a N cr_ N w � Ljj 00 D Co w :D 1- a n m (Dr LL W 0 z O F— J f rl }. w / LL LANDS N/F ROSS,JERAD �. 137.-1-49.1"',�- (0.24 AC) �+ i / / I V) v t" SPOIL AREA i O LANDS97.16-1-2.12ERAD (0.27 AC) '' z 0 00 NEW 2,500 GAL PRECAST CONCRETE ,.. 0 N coao �V4 �;.r MULTI -COMPARTMENT SEPTIC TANK 5_2 1 = z 1 F LANDS N/F WARREN 297.-16-1-2.11 (3 AC) M LANDS N/F WARREN CO 137-1-49.3 (kM AC) DATE: 10/6/2022 SCALE: 1" = 20 FT SHEET: S-1 THE FORT MILLER CO., INC in BOX% TEST PITS ADVANCED 9/22/22 BY K WOOD TP-1 0"-3" TOPSOIL W/ GRASS 3"-18" DARK BROWN LOAMY SAND W/ STONES (4" MINUS) 18"-30" MED BROWN LOAMY FINE SAND W/ STONES (2" MINUS) 30" BOTTOM OF HOLE NO GROUNDWATER, MOTTLING OR BEDROCK OBSERVED NO SIGN OF EXISTING ABSORPTION FIELD COMPONENTS FOUND TIP-2 0"-3" TOPSOIL W/ GRASS 3"-12" DARK BROWN LOAMY SAND W/ STONES 12-18" IVIED BROWN LOAMY FINE SAND W/ STONES 18" BOTTOM OF HOLE NO GROUNDWATER, MOTTLING OR BEDROCK OBSERVED NO SIGN OF EXISTING ABSORPTION FIELD COMPONENTS FOUND TIP-3 0"-72" FOUNDATION EXCAVATION FROM PREVIOUS STRUCTURE LT MEDIUM GRAINED SAND - APPEARS TO BE BACKFILL MATERIAL NO BOUNDARY CONDITIONS NOTED - GROUNDWATER/ BEDROCK PERCOLATION TESTS_ 9/22/22 - BY KEVIN WOOD, P.E. TP-1 CONDUCTED AT 20" DEPTH BGS RUN # START STOP PERC RATE PRE -WET 14:20 15:20 1 15:23 15:35 12 2 15:35 15:48 13 3 15:50 16:03 13 4 16:03 16:17 14 5 16:20 16:35 15 6 16:35 16:50 15 7 16:50 17:05 15 STABILIZED RATE = 15 MIN/IN TP-2 CONDUCTED AT 12" DEPTH BGS RUN # START STOP PERC RATE PRE -WET 14:20 15:20 1 15:25 15:40 15 2 15:40 15:57 17 3 15:57 16:14 117 4 16:17 16:34 17 5 16:34 16:51 17 STABILIZED RATE = 17 MIN/IN 8 BEDROOM RESIDENTIAL DESIGN FLOW = 110 GPD/BR SYSTEM DESIGN FLOW = 880 GPD SEPTIC TANK = MIN CAPACITY = 2,250 GAL MIN LIQUID SURFACE AREA = 61 SF PROPOSED LEACHFIELD = ABSORPTION TRENCHES W/ INFILTRATORS DESIGN PERCOLATION RATE = 17 MIN/IN APPLICATION RATE = 0.7 GPD/SF REQUIRED ABSORPTION AREA = 1,257 SF TRENCH WIDTH = 2 FT REQUIRED ABSORPTION TRENCH LENGTH = 629 FT (0.75 INFILTRATOR REDUCTION) = 472 FT MAXIMUM ALLOWABLE TRENCH LENGTH = 60 FT THEREFORE, USE 8 TRENCHES AT 59 FT THE SYSTEM IS NOT DESIGNED FOR THE FOLLOWING WASTEWATER SOURCES: HOT TUBS, GARBAGE DISPOSALS, ROOF OR FOOTING DRAINS, GARAGE OR BASEMENT FLOOR DRAINS OR SUMP PUMPS. HOUSE SEWER PIPE: 4" SOLID SDR-35 OR SCHD-40 PVC AT 1/4" PER FOOT MINIMUM SLOPE SEPTIC TANK: 2,500 GAL PRECAST CONIC MULTI -COMPARTMENT, FORT MILLER OR EQUAL EFFLUENT SEWER PIPE: 4" SOLID SDR-35 OR SCHD-40 PVC AT 1/8" PER FOOT MINIMUM SLOPE DISTRIBUTION BOX: 8 OUTLET PRECAST CONC, FORT MILLER #2 D-BOX OR EQUAL, WITH SPEED LEVELERS DISTRIBUTION BOX OUTLET PIPE: 4" DIA SOLID SDR-35 OR SCHD-40 PVC AT 1/8" PER FOOT SLOPE ABSORPTION TRENCH: QUICK4 EQUALIZER 36 CHAMBERS BY INFILTRATOR WATER TECHNOLOGIES TOPSOIL: 4" MINIMUM ORGANIC TOPSOIL COVER ENTIRE DISTURBED AREA, SEEDED AND MULCHED ABSORPTION FIELD SOIL, IF REQUIRED: SOIL WITH SIMILAR PERC RATE TO IN -SITU SOILS, NO COURSE MATERIAL > 1" 1) CONSTRUCTION SHALL BE IN ACCORDANCE WITH NYSDOH APPENDIX 75-A STANDARDS AND THESE PLANS 2) CONCRETE STRUCTURES TO BE SET LEVEL ON A 12" BED OF COMPACTED CRUSHED STONE ON UNDISTURBED NATIVE SOIL 3) HOUSE SEWER EXTENSIONS AND TANK EFFLUENT PIPES SHALL BE BEDDED ALONG THEIR ENTIRE LENGTHS IN MIN 4" GRANULAR FILL MATERIAL 4) ALL PIPE CONNECTIONS TO BE CHEMICALLY WELDED, AND ALL PENETRATIONS AT CONCRETE STRUCTURES TO BE GROUTED WATERTIGHT 5) ALL DISTRIBUTION BOX OUTLET PIPES SHALL HAVE THE SAME INVERT ELEVATIONS 6) ABSORPTION TRENCHES SHALL BE INSTALLED PARALLEL TO THE CONTOURS OF THE NATIVE SOIL TO THE LIMITS SPECIFIED 7) BOTTOM OF TRENCHES TO BE SET LEVEL - SIDEWALLS AND BOTTOMS RAKED AFTER FINAL GRADING 8) INSTALL INFILTRATOR CHAMBERS IWA MANUFACTURER'S INSTRUCTIONS AND BACKFILL WITH THE EXCAVATED SOIL 9) MOUND THE BACKFILL MATERIAL SEVERAL INCHES TO ALLOW FOR SETTLING 10) COVER ALL DISTURBED AREAS WITH 6" TOPSOIL, SEED AND MULCH 11) REMOVE EXCESS SPOILS NOT ABLE TO BE REUSED IN THE RE -DEVELOPMENT FROM THE SITE, ALL DISTURBED AREAS TO BE RESTORED TO PRE -CONSTRUCTION CONDITION AND/OR IAW THE FINAL RE -DEVELOPMENT PLANS 12) ANY EXISTING SYSTEM COMPONENTS THAT ARE ENCOUNTERED AND ARE IN THE WAY OF THE NEW SYSTEM INSTALLATION SHALL BE EXCAVATED AND RELOCATED TO THE SPOIL AREA NOTED ON SHEET S-1. RELOCATED MATERIALS SHALL BE GRADED ALONG THE SLOPE AND COVERED WITH A MIN OF 2 FT OF CLEAN COMPACTED COVER SOIL, SEEDED AND MULCHED. EXISTING TANKS TO BE ABANDONED IN PLACE BY PUMPING EMPTY AND BACKFILLING WITH SOIL. 13) ANY SOIL WHICH MAY NEED TO BE PLACED WITHIN THE ABSORPTION FIELD AREA AFTER REMOVAL OF EXISTING SYSTEM COMPONENTS SHALL CONSIST OF LOAMY SAND HAVING A SIMILAR PERCOLATION RATE AS EXISTING NATIVE SOILS. FILL TO BE STABILIZED IN 6 INCH LIFTS TO REQUIRED GRADE PRIOR TO CONSTRUCTING ABSORPTION TRENCHES. 22" FRONT VIES r�....x .......------------------------- SIDE VIEW THF_ FORT MILLER CO„ INC P() BOX 98 1 SEE CHART I 1200-1500 GAL, T-0" 2000-2500 GAL. 1 a" / (TYP) >'` — 24"0 OPENING (TYPICAL) 1$„ TYPICAL -..,.- 6" X '18" OPENING FOR ALL (3) INLETS _NOT'GS: INLET AND OUTLET TEES SUPPLIED BY CONTRACTOR • INLET KNOCKOUTS PROVIDED FOP, 6" O PIPE ON TIiREE SIDES, DESIGN CASE 3 (TRAFFIC) s > 200-1500 GAT.. / / 2000-2500 GAL. 48 \ SLIDE -IN BAFFLE _ ___ LIQUID INLET OUTLET TANK WEIGHT, LOS SITE GALLONS OUTSIDE HEIGHT LEVEL HEIGHT HEIGHT lOP BOTTOM BAFFLE TOTAL ,L, O, SECTION SECTION WEIGHT WEIGH 4'-D" 10,000 11,740 960 22,700 1500 6'-3"— 4'-1" 5'-1" 4;-10" 12,000 11,740 1175� 24,915 2000 5'-11" 3'-9" 4'-9" 4'-6" 13,140 16,320 1300 30,760 2500 6'-11" �'-9" 6'-0" 5'-6" 16,000 16,320 1605 33,925 TOP VIEW fRitYi'MR9I�n SU.kRc� 9LnUnkhP he^ICC' f S r`�,ifl.li'if 'Txti'A4hnftt 3 INFILTRATOR CUT SHEET 5-2 SEPTIC TANK CUT SHEET c z CROSS SECTIONAL VIEW N IN6tK IS (5:WttU LtVtLthS) AVAILAGLL W-UN KLUULb I • TOP, BOTTOM, AND SIDES ALL 12" THICK. • DESIGN CASE 2 (TRAFFIC) SLAB TOP BOTTOM TOTAL (LBS) (LBS) (LBS) 50 144 194 KNOCKOUTS WITH HIGH DENSITY POLYETHYLENE PIPE SEALS. 2 5-2 DISTRIBUTION BOX CUT SHEET TOP SOIL MOUNDED D FOR SETTLING 1 FARTH SACKFILL 1 i z SPACING OF INFILTRATORRCWS= &FTO CENTER SPACING BETWEEN TRENCH SIBEWALLS= 4 FT LONGITUDINAL VIEW ABSORPTION TRENCH DETAIL w O U U) w J mo m �w 0w U) w �w Q W m Z z z O F aUJm>_ y,I cn U arn � �cr 0-W N O � W > Q N � 0 00 U z W � m w w t_I_ w N 0 z 0 J Q W p Lu 00 N E w O a z rn - •� u' O 00 H : 00 w coM � Z U w ^ w 00 -0 W N `� 3 Y N C7 u" DATE: 10/6/2022 SCALE: NTS SHEET: S-2