IM Inspection Worksheet_19-01-2024_15-13-09INSPECTION WORKSHEET (BINS-000295-2024)
RC-0360-2022Case Number:Case Module:Permit Management
01/19/2024 PassedInspection Status:Inspection Date:
Building InsulationInspection Type:Inspector:Charles Dyer
Job Address:Parcel Number:373 West Mountain Rd
Queensbury, NY 12804
308.9-1-11
Company Name NameContact Type
Applicant Mark Reichen
Contractor Fine Home Building
Granted Permission Jessalie Reichen
Primary Owner Jessalie Reichen
Mark Reichen
Checklist Item CommentsPassed
Building Inspector Notes True For 2" foam board and radiant hydro lines @ garage and 3
season room, holding 40+ psi. 11/28/22. All verified 1/19/20
U Factors = .3 cfm for windows, .5 cfm for doors True
Tub Shower R-20 with Vapor Barrier True
Air Seal all Plates and Sills True
Exterior wall outlets sealed True
All Return Air Hard Duct Work True
Duct work sealed properly / No duct tape True
Duct Testing Outside Conditioned Space False
Air Seal All Registers at Floor True
House Wrap Taped at all Seams True
Air Sealing all Joints Before Insulation True
Door / Window Sealed (No Insulation)True
Air Seal Outside Penetrations True
All Ductwork Sealed Return and Supply True
Blower Door Test True Verify at final
Duct Insulation - if required in unheated spaces False
15 min thermal barrier/intumescent paint applied True
Tyvek or Similar Exterior Sealant True Zip System
Combustion Air Supply for Furnace True
Fresh air supply 3' from grade True
Window Sealing True
Duct Blaster Test for duct work, R-8, unhtd spaces False
Permit Card Visible From Road True
Proper Vent, Attic Vent True
Insulation ResCheck ComCheck True Partial / R 21 @ sunroom R 38 @ garage ceiling 5/16/23
Home is of ICF walls R value of 30+
January 19, 2024 Page 1 of 1