IM Inspection Worksheet_19-01-2024_15-16-44INSPECTION WORKSHEET (FMGAS-000297-2024)
RC-0360-2022Case Number:Case Module:Permit Management
01/19/2024 PassedInspection Status:Inspection Date:
Gas Fireplace/StoveInspection Type:Inspector:Charles Dyer
Job Address:Parcel Number:373 West Mountain Rd
Queensbury, NY 12804
308.9-1-11
Company Name NameContact Type
Applicant Mark Reichen
Contractor Fine Home Building
Granted Permission Jessalie Reichen
Primary Owner Jessalie Reichen
Mark Reichen
Checklist Item CommentsPassed
Fire Marshal Notes True Rough-in: ok; call for final insp /verified 1/19/24 CMD
Installed per manual True
Floor Protection True Wood or non-combustible surface; no linoleum or carpet =>
verified wood platform & structure
CO Detection True Verify at final inspection / verified 1/19/24
Vent Chimney Termination True Thru the gable end wall, North side of the house
CSST Bonding True Does not appear req'd => Verify at final inspection / black flex
Connected to flue: flue gases not mixing w/rm air True
Gas Shut-off Valve False Verify at final inspection
Mantel-height above fp opening False Min 8" depth, 41-1/2" above base of fireplace => verify at final
inspection
Tank Placement (if LP)True Did not observe location
Model True MV/GSB2
Weather cap installed True
Hearth Extension (if any)True Not req'd; however, if provided, must be non-combustible as well
as structure => verified none to be provided
Combustion Air True Does not appear to be separate requirement => verified pulling
room air
Vent Clearance to Combustibles True 1" above, sides and below => verified dimensions
Manufacturer True ProBuilder 72 Linear
Witness Operation True Verify at final inspection / witnessed 1/19/24
Clearances to Combustibles (all sides)True 1/2" sides and back => verified
Firestop(s) - Vertical Chase True Required => verified