Loading...
1988-262 CERTIFICATE OF OCCUPANCY TOWN OF QUEENSBURY WARREN COUNTY, NEW YORK Date April 20 19 90 ()30 I ),(13 • This is to certify that work requested to be done as shown by Permit No. 88-262 has been completed. This structure may be occupied as a 1 of two family dwelling Ioration R oneen Anne Court - Model J - Ouuen Victoria's Grant Owner Guyer Builders, Inc. By Order Town Board • TOWN OF QUEENSBURY J) Building &j Zoning inspector BUILDING PERMIT 54 TOWN OF QUEENSBURY No. 88-262 'zs WARREN COUNTY, NEW YORK PERMISSION is hereby granted to Guyer Builders, Inc. OWNER of property located at 8 Queen Anne Court — Queen Victoria's Gra Street, Road or Ave. rn in the Town of Queensbury,To Construct or place a 4 of two family dwelling at the above location in accordance to application together with plot plans and other information hereto filed and approved and in compliance with the Town of Queensbury Building and Zoning Ordinance. 1. OWNER'S Address is 119 Dunning St. m Ballston Spa, N.Y. 12020 0 2. CONTRACTOR or BUILDER'S Name n' Same ti to 3. CONTRACTOR or BUILDER'S Address IL Same rt 4. ARCHITECT'S Name to 5. ARCHITECT'S Address 6. TYPE of Construction—(Please indicate by X) (X)Wood Frame ( ) Masonry ( ) Steel ( ) n- 7. PLANS and Specifications F'h No. 32' X 48' as per plot plan, specifications and application rr including septic system and one—car attached garage — Model J • 8. Proposed Use W 3/4 of two family dwelling ti 5.00 C/O $ 89.00 PERMIT FEE PAID —THIS PERMIT EXPIRES December 1 19 88 ti (If a longer period is required an application for an extension must be made to the Building and Zoning inspector of the town of Queensbury before the expiration date.) Dated at the Town of Queensbur his 23rd Day of May 1988 SIGNED BY for the Town of Queensbury Building and Zdning Inspector . -Ay bb LvArlit.wiU tit 3Luv. saLe i. • I/ Application No. _r owN OF QUEENS .I o win of Queenibury Permit Issued 19 Q -.1i M -.I 1 iP .{J - I j BUILDING and ZONING DEPARTMENT Permit Expires 19 • Pay and Haviland Road, R.D. 1 Box 98 Zoning Designation 2 198(�v Oueensbury, New York 12801 Variance No. . �1, Site P d ew No. BUILDING a- CODE DEPT. �, �� Appao b • 9 y :^c-'l �C PPLICATION FOR BUILDING- AND ZONING PERMIT •- -zAwa * *• * * *• * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *::* A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. ANSWER ALL OF THE FOLLOWING. The undersigned hereby applies for a Building Permit to do the following work which will be done in accordance with the description, plans and specifications submitted, and such special conditions as may be indicated: on the Permit. " •4 _ The owner of this property is: Guyer Builders, Inc. P.O. Address 119 Dunning. Street Ballston Spa, New York 12020 •Tel. (518) •899-9161• Property Location: 8 Queen Anne Court Tax Map No.121 / 4 / 2 Street number or building lot number Subdivision name (if applicable) Queen Victoria's Grant THE PERSON RESPONSIBLE FOR SUPERVISION OF- WORK AS REGARDS BUILDING CODES -IS: - • • Richard H. Guyer III • (518) 899-9161 Name P.O. Address Tel. No. • 'Name of builder •Guyer Builders, Inc.Address 119 Dunning -Street . Tel. (518) 899-9161 Name of plumber Guyer Builders, lnc.Address 119 Dunning Street Tel. (518) 899-9161 Name of mason Guyer Builders, 1nc.Address 119 Dunning Street - Tel. (518) 899-9161 NATURE OF PROPOSED WORK: • ' * ZONING INFORMATION: • X Construction of a new building * A PLOT PLAN MUST BE PREPARED AND SUBMITTED, Addition to a building *- drawn reasonably to scale and attached hereto, --Alteration to a building * A showing clearly and distinctly all buildings, (no change to exterior dimensions) * whether existing or proposed and indicate all Other work -(describe) * set-back dimensions from property lines. Give * street and number or lot number and indicate FOR DEMOLITION PERMIT, STATE SIZE AND . - •* whether interior or corner lot. Show location of water supply and location and configuration LOCATION OF STRUCTURES AFFECTED. * of septic disposal area. . *:COMPLETE-INFORMATION REQUIRED B��-' OW. . . *. ..:• ::,". 100± pganplgt X 120 ft. Size 'of property • * Existing building(s) Size N/A ft X N/A ft. Model 1�J * .., - PROPOSED BUILDING AND USE: Existing building(s) Use " N/A Size of new struc e 32 ft X 48 ft *" " " Foundation-pier slab crawl/partial/full * Proposed building, distance from property line circle one) * see plot plan * Front yard 30+ ft Rear yard No. of stories (habitable space) 1 ar ft. Higlu (grade to ridge) 1y 6 ft. * Side yards 15+ ft and 15# ft . I residential, no. of families l of 2 * If on corner, setback from side street 30+ ft lip. of rooms(excluding baths) "1"'-- * OCCUPANCY INFORMATION No. of bedrooms 2 * * PRIMARY BUILDING - • No. of bathrooms 2 One family dwelling This ei for Primary heating system Baseboard electric* — Two family dwelling one stile of miming. Type of fuel Electricity * Multiple dwelling / Number of units No. of fireplaces to be installed permanent occupancy Will .a wood stove be installed? No * • Transient occupancy Central Air conditioning? No * * Business BUILDING STYLE, PRIMARY STRUCTURE * Industrial * Other Ranch Contemporary La. cabin * If addition, what will use- be? Raised ranch Mansion Duplex . . . Split level Old style Bungalow * Cape Cod Cottage Other * ACCESSORY BUILDING- .,..•:" • Colonial Row Town House * Detached garage/one car/ two 'car/ car ( CIRCLE ONE PLEASE ) * )( Attached garage/one car/ two car/ one car • * * * * * * * * * * * * * * * * * * ' Private storage building ESTIMATED MARKET VALUE OF * Other • • • CONSTRUCTION $ (115CD _ * INFORMATION ON •BUILDING SPECIFICATIONS, ON REVERSE SIDE OF THIS SHEET, TO BE COMPLETED! _ Form BPA 4/86 and-vl • BUILDING PERMIT APPLICATION CONTINUED - BUILDING SPECIFICATIONS: . Type of construction, wood frame, fire safe,etc. wood frame Will any second-hand or ungraded lumber be used? If so, for what? no Foundation wall material concrete block Thickness 8" Depth of foundation below grade (to bottom of footing) 48" minimum . ' Will there be a cellar? 'no Heated or unheated? Floor sq. footage sq ft .. Will there be a basement? no Will any portion be used as living space? (If so, what port? sq.ft. - - Type of use? Type of roof -(iloped)flat/shed/other Material of roof Fiberglass shingles Size, wood studs 2 "X 6 " spacing 24 "o.c. length 8 ft. exterior walls . Joists(floor beams) 1st. floor N/A'"x " spacing_ _"o.c. span N/A ft. . Joists (floor beams) 2nd. floor - "x - '' spacing ) 'o.c. span N A ft. • Overlays(ceiling beams) "X " spacing 24 "o.c. span N/A ft. • Roof rafters 2 "x 10" spacing 24 o.c. span 14 ft. . Roof trusses(pre-engineered) spacing 24 "o.c. span 42'ft. Exterior wall finish stained Of what material? 5/8" x 4' x 8' texture 111 Interior wall finish paint 1/2" sheetrock If a garage is to be attached, describe materials to be used for FIRE SEPARATION: 1/2" type "X" sheetrock Is there to be an opening between garage}and dwelling? yes If so will a Fire-rated door, enclosure, and self-closing device be provided? yes Will a flue-lined chimney be installed? No Height above roof N/A ft. Depth of chimney foundation below grade N Aft Depth of fireplace hearth N/A ft. in. Water supply - Municipal or private well municipal SEPTIC SYSTEM _ Distance from ANY private well(including adjoining properties N/A , ft. (A separate application is necessary for any repair or new installation of septic system) See S.P.E.D.S. permit # 0202525 Town of Queensbury AFFIDAVIT County of Warren STATE OF NEW YORK • I swear that to the best of my knowledge and belief the statements contained in this application, together with the plans and specifications submitted, are a true and. complete statement of all proposed work to be done 'on the described premises and that all . provisions of the BUILDING CODE, THE ZONING ORDINANCE, and all other laws pertaining to the proposed work shall be complied with, whether specified or not, and that such work is authorized by the 'owner. SWORN TO BEFORE ME THIS signature • clit. l _ �L_ Owner, owner's a nt,architect,contractor /1,�IS— day of / 19 �� ARN,' NotaryD PublicIENNE,StatJ.ePl ofDER 1J ,York Atitia_-. /. LLB Qualified in Saratoga County No.4907592 Notary Public, County, N.Y. Commission Expires Oct. 13, 192Q * * * * * * * * *_ * */' * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * , * SPECIAL CONDITIONS OF THE PERMIT: ;=�� ._1. . square feet s'4'1n 1123stall , f-t gara e — one. .;..N:., 240are . 1363 @ $7.001100or Part of Ir. 5.00 O� stall �e �— .00 c/o permit , . . Total ... . • By TOWN OF QUEENSBURY nju WARREN COUNTY, NEW YORK Application for: . BUILDING PERMIT IN COMPLIANCE WITH THE NEW YORK STATE ENERGY CONSERVATION CODE . . • A permit must be obtained before beginning work: • ANSWER ALL of the following; Gross floor area 1123 S.F. • 2. Type of heat Baseboard electric 3. Is the building mechanically cooled? No 4. Percentage of area of windows and doors • 11.8% A. Over 16% Only 1. Uo value of gross area of walls , roof/ceiling and floors exposed to ambient conditions 2. Floor over heated spaces YES NO a. Are foundation walls insulated? YES NO • • 1. If YES, what is the R value? 3. Slab on grade YES Ng a. If YES, what is the R value of insulation around perimeter of floor? • • 4. Is basement heated? YES NO a. R value of insulation 5. Type of insulation 8. Under 16% Only 1. R value of roof and floors exposed to ambient conditions• R-38 2. R value of exterior walls R-23.5 (U.=0.04+) • 3. R value of glazed area U.=0.30 • 4. R value of doors R-14.9 (U.=0.06) • 5. R value of floors over unheated spaces NXYNX R-30 6. R value of slab edge insulation - unheated slab N/A 7. R value of slab insulation - heated slab 12.5 8. R value of heated basement/cellar walls (above grade) N/A 9. R value of heated basement/cellar walls (below grade) N/A 10. Type of insulation Fiberglass C. Controls 1. Thermostat maximum heat setting • D. Duct Systems N/A 1. Is duct system installed in unheated spaces? YES NO a. If YES, R value of/duct installation b. R value of duct in other areas E. Piping Insulation N/A 1. Size of hot water or cooling carrying agent pipe 2. R value of pipe insulation F. Service Water Heating 1. Performance efficiency N/A 2. Temperature control setting maximum G. For Swimming Pool Only 1. Maximum heating N/A ". . Telephone No. (518) 899-9161 (applicant ' signature) OW% o Quem4p J APPLICATION FOR SEPTIC DISPOSAL PERMIT Ref: S.P.E.D.S. DATE 10-16-87 / permit #New York - 0202525 MODEL J of I/J LOCATION OF PROPERTY FOR INSTALLATION 8. Queen AnneCourt Owner's-Name: Guyer Builders, Inc. • Telephone: (518) 899-9161 Address: 119 Dunning Street, Ballston Spa, New York 12020 Installer's Name: Guyer. Builders, Inc .- Telephone: (518) 899-9161 2 A, C, E, I, J, K, L, M Number of bedrooms (residential only) 2 3 F, G, H Total daily flow (compute @. 150 gal per bedroom). 300 • Topography: circle one: GM Rolling Steep Slope %-of slope Soil Nature: circle one: Sand Loam Clay Other / Depth: . 8' feet + Ground Water: At what depth? known 8 feet + Bedrock or Impervious Material: At what depth? unknown feet Percolation test: circle one: 16-ot require required / rate min. inch. Domestic water supply: circle one: . Municipal Well Other IF domestic water supply is a Well: Separation: Watersupply from Septic absorption _ N/A feet, * PROPOSED SYSTEM: Septic Tank gal. (minimum size: 1,000 gal.) . • TILE FIELD: Each Trench N/A feet / Total system length N/A feet • * SEEPAGE PIT(S): Number of / Size each feet by feet' * Size of stone to be used.# / Depth or Thickness feet * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * IMPORTANT * See S.P.E.D.S. ...Please...LIST NEW EQUIPMENT TO BE INSTALLED permit & attached * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *- map. (over) Section II Septic System Inspections: A. All applications for septic system installation, alteration or repair, as required by the Town of Queensbury Sanitary Sewage Ordinance,shall • be submitted to the Building Department at least 24 hours before start . of construction and shall include a plot plan showing: 1.) the proposed,location of the system 2.) location and distance to lot lines 3.) location and distance to structures 4.) location and distance to anywater supply 5.) size and dimensions of all tanks, distribution boxes, tile fields and/or drywells B. No system shall be covered before inspection and approval by the building_. Inspector. Failure to comply with this requirement may result in the uncovering of the system by the installer and a fine of up to $250.00. C. An approved copy of the plot plan shall be available on the construction site. Failure to produce said plot plan at time of inspection may result in an immediate work stoppage. D. Should unforeseen problems during construction prevent proper installation, alteration or repair of an approved system, a new proposal must.be submitted to the Queensbury Building Department before further construction. I have read the regulations above and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. Signature of.responsible person: • Date: • Town of Queensbury Building and Code Department Bay at Haviland Road Queensbury, New York 12801 (518) 792-5832 • • SETTLFr 1763 . . . HOME OF NATURAL BEAUTY . . . A GOOD.PLACE TO LIVE INTERIM BUILDING PERMIT . PERMIT. APPLICANT y ,e2 ER , c ,"/Je e S' Qa-cesi ayrn,c CONSTRUCTION LOCATION aJ y, 6 $< eo is , .N/./6 - s ao; .aa as, EFFECTIVE DATE /:f02.1 02 /9 P APPROVED BY SPECIAL CONDITIONS : • This will certify that all submittals for a Building Permit have been received and fee has been paid . During the processing of the Permit , the above named may begin construction per plans submitted . It is the responsibility of the applicant to obtain the Permit from the Building Department, following processing . POST TIIIS INTERIM PERMIT IN A CONSPICUOUS OCATION ! ! Z(/ Building & Codes Department . TOWN OF QUEENSBURY ' O • • �° D • I, MIDDLE DEPARTMENT INSPECTION AGENCY., INC. -7 �...m�. National Headquarters 900 Haddon Ave., Collingswood, N.J.08108 APPLICANT COMPLETES THIS SECTION Date: 542-88 Ci Z; Town or2 t Queensbury County r Warren State `' Location/Address 8 queen .s aT tie Court - (If Located in Rural Area-Please Attach Directions) Pole # - Owner erryer Winders Inc. Permit # P) ' 2--- Occupied As r'c r Vv7r ( Building: New Old❑ J Occupant - - - . Work Area in Building (Floor #,etc.): App. for: Wiring 111-11 Service[l or: • Ready for Inspection: Fee Remitted-$ - - Cash❑ Check n M.O. n Make Payable To: M.D.I.A. 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000 Number of Rough Wiring Outlets Elect. Heat -, Switches Lighting Amp. Service Surface Unit Dishwasher Range Receptacles Water Heater Air Conditioner Dryer - Pump Number of Fixtures . Oven Garbage Disposal Wiring and Controls for Burner - Amp. Receptacles Fractional H.P. Vent Fans Other Equipment: - MOTORS H.P. 1/201/12 1/10 1/8 1/6 1/4 1/3 1/2 3/4 1 11/2 2 3 5 71/2 10 15 20 25 30 040 50 75 100 Mark Number. - • of Each Size 0 Applicant's . Signature License # Permit # T/A Guyer Builders Inc. Utility: 'iV •!/ ) •65 f -"' / c 7/ Applicant's Address: 119 Diming Street (NAME) (OFFICE LOCATION) (City) B141.1P,1:031 t " (State) IN (Zip)' T2020. Service Request # 0 Phone'# 61. Electrician: Guyer Builders Inc. MDIA USE ONLY DATE RECEIVED: �' " G ? DATE INSPECTED: u� 2- c) Correct-Location: Same as Above? or: - Red Notice Label n - . Rough Wiring Outlets Surface Unit t Oven / ,Switches ( Range / Garbage Disposal . 0 Receptacles / Water Heater / Dishwasher c) Fixtures Air Conditioner ' if Dryer ,j 12-t=.Amp. Service Equipment Burner,Wiring&Controls for Amp. Receptacle Amp. Service Conductors Pump ,t.-er'-- Vent Fans MOTORS H.P. 1/20 1/12 1/10 1/8 1/6 1/4 1/3 1/2 3/4 1 11/2 2 ` 3 5 71/2 10 15 20 25 30 40 -50'' 75 100 Mark Number - of Each Size 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000 Elect. Heat - • CERTIFICATIONS USE FOR INITIAL VISIT ONLY NOTIFIED DATE CORRECTFEE FEE PAID ❑ RW Progress: Inc.[(J- LKD❑ Contractor _, f" El CFT CFT Violation:• Work Comp.❑ Inc. °' ' J� n L/A - Owner CASH El E L/A _ Fee • CHK # . Due MO # • n IPA Municipal INV # Date: - - Other Side El Utility` r ( Applicant` ❑❑ - . _ `- __ Owner Cut in Card r ' n Temp # Date /1 ,�; � �J/!�/; FOrrinaI # (, (u 3 57 Date ks' .- ? r , INSPECTORS SIGNATURE APPLICATION FORM NO.250 EL 11/86 - - Ife.,1vJNw v %.J VJ4.vJ,,V.vJ.4"ve1 vJ ver v v '‘,er4+vel4Wvei vei X,c/48\3LiAl vcl+ �vc1 N.: (� MIDDLE DEPARTMENT INSPECTION AGENCY, INC. 'J 900 HaddQn'Avenue,CollingpwoNock J'08108 qi C ,f.1 1 a g^ ��� Date April 9, 1990 C� 'L ertlf leg that the eJectrical,equipment listed has been examined and`is approved as being in accord i with the National Electrical/Code,rapplicable governmental utility and,Agency rules. C` ( r f ) Owner: z ` J ' • D ae,11i1 g k, Guyer Luilders :Tnc;�� / � '�� t � � � ,,, O� c� pancy� � � ; ( p Single I.amilyi `e j \ I f ;` , ) Occupant: d {.-. � � �,. �fi, a��t�,,, ' �"� � �_;_ 8 c ueen Anne Co}trt ueensbr'u ' (eWa>~ren Coy)/ NY a„ e rr-1 C (� Location: 2 I t .? This-certificate cover, the�electncal equipment and installation inspected this 4) ,,,., : date. If additional equipment((should be introduced or alterations made to ..5. , existing system this'cartljicatB shall'be null and void, and application for C 3 O' P" ( _inspection should he submitted promptly to this Agency. (' Equipment: 70 Outlets•, _ Receptacles; '20. Fig t ,des; [ } �, 21 G '1 t;.J P i 'tHolder of this certificate sha6ld,present same to his property insurance carrier 150 Amp Service:;._;,6\Appliances; Vent a�is (agent or company)asevidpnceofcertificationofelectricalequipmentapproved Fr,, , \� as specified.f.' ..i e \'`'fa \� .` f C r T Guyer Bui].deis<In`c `` • ' . ., ( Applicant: 1.19 Dunning S Lreet -- 4-v Jl 1.a 41""� t N ~— _._---- �`No. 15-032490 Ballston Spa, NY 120 20_ ;y v '°` f C` L. 1_„`y.: » J .�ck l+n.r �g>,'zz / v �1.Mra�t «M�1., "-fz �„,k `, s Form No.703 EL 1-83 . TOWN OF QUEENSBURY BUILDING AND CODES DEPARTMENT BAY & HAVILAND ROADS QUEENSBURY, NEW YORK 12804- TELEPHONE (518) 792-5832 BUILDING INSPECTOR'S REPORT REQUEST FOR INS ECTION RECEIVED 41Z� 0Q NAME 4er_ 4�� � LOCATION 1,4a4e, ,d,t,,,,_ 6.7..m,y_ DATE 1 G PERMIT # f f— z t PPROVED _4 , 10/Y11:14 ES NO FOOT NG/PIERS I MONOLITHIC POUR FORMS I// • FOUNDATION/DAMP-PROOFING BACKFILL APPROVAL ROUGH PLUMBING FRAMING ELECTRICAL ROUGH-IN I INSULATION: (1 I. FOUNDATION h i FLOORS , I • WALLS j CEILING is. I • lx FINAL INSPECTION: r CHIMNEY HEIGHT .. �� ROOFING ✓SIDING 1 d ✓ EXTERNAL PORCHES/STEPS I STAIRS-CLEARANCE & RAILS i 4 PLUMBING FIXTURES/REIiIEF VALVE INTERIOR TRIM/PRIVACY`;DOOS ✓ FINISHED FLOORS i ✓/ GARAGE FIREPROOFING `' # DOOR CLOSER(S) \/ ,✓ SMOKE DETECTORS j;. 1/ FINAL ELECTRICAL INSPECTI;ONE • ✓ K FINAL APPROVAL OF CONSTRUCTION `,t 1 A SIGNED CERTIFICATE OF OCCUPAtNCY MUST BE OBTAINED FROM THE BUILD NG DEPARTMENT BEFORE THESE PREMISES ARE OCCU IED! REMARKS: "E } • 1 ,7 1 1� . \ . 1 • IL INSPECTOR ' \ ;\\' _MIDDLE DEPARTMENT INSPECTION AGENCY INC.Electrical-Building-Plumbing-Fire Inspections Qfi Date :�F f ,.- tatRillia 11°. cto11)- 4.1 T� " constitutes above installation,itconstitutes Certification that the ment itself,has ben visually insp but not the ected as of this date pursuant to the A g ted able codes. if additional e should be introduced applic- - madeable to theexistingalterations or alterations 'j ture, application for inspection or should be submitted Aection n -� promptly to this Agency, TOWN OF QUEENSBURY BUILDING AND CODES DEPARTMENT BAY & HAVILAND ROADS QUEENSBURY, NEW YORK 12801- TELEPHONE (518) 792-5832 BUILDING INSPECTOR'S REPORT REQUEST FO INSPECTION RECEIVED /'� f C� N4 NAME t / l. /� bVJtLLOCATION It ftALP At nA DATE + flO lY!PERMIT # P,/! D— APPROVED • YES NO FOOTING/PIERS , MONOLITHIC POUR FORMS ' FOUNDATION/DAMP-PROOFING BACKFILL APPROVAL ; aROUGH PLUMBING 4// _'FRAMING ELECTRICAL ROUGH-IN INSULATION: ' FOUNDATION FLOORS i „ WALLS tt CEILING k,, FINAL INSPECTION: Y CHIMNEY HEIGHT ;t ROOFING • ' SIDING ri,d EXTERNAL PORCHES/STEPS STAIRS-CLEARANCE & RAIILS PLUMBING FIXTURES/RELIEF VALVE INTERIOR TRIM/PRIVACY DOORS FINISHED FLOORS .v i GARAGE FIREPROOFING DOOR CLOSER(S) 'v SMOKE DETECTORS I FINAL ELECTRICAL 4SPECTIOI16 FINAL APPROVAL OF JCONSTRUCTION • } / ' A SIGNED CERTIFICATE OF OCCUPANCY MUST BE OBTAINED FROM THE BUILDING DEPARTMENT BEFORE THESE PREMISES ARE OCCUPIED! REMARKS: r !' / . 7/ i���/ ice / p ji/ I;' Y'zi ,i;j ,� is / INSPECTOR /41, TOWN OF QUEENSBURY BUILDING AND CODES DEPARTMENT BAY & HAVILAND ROADS QUEENSBURY, NEW YORK 12804. TELEPHONE (518) 792-5832 BUILDING INSPECTOR'S REPORT REQUEST FO; INSPECTION(RECEIVED NAME LOCATION / �/ '.rile_ `�L 1 DATE c ;-?-/U P(RMIT # f - / APPROVED 4 / i ! YES NO FOOTING/PIERS I i! MONOLITHIC POUR FORMS • FOUNDATION/DAMP-PROOFING BACKFILL APPROVAL ROUGH PLUMBING / FRAMING S ELECTRICAL ROUGH-IN (.NSULATION: FOUNDATION ' FLOORS �s, WALLS JI! y� ./ CEILING i 6 FINAL INSPECTION: y CHIMNEY HEIGHT // ROOFING 1 SIDING 1 EXTERNAL PORCHES/STEPS STAIRS-CLEARANCE & RAILS PLUMBING FIXTURES/RELIEF VALVE INTERIOR TRIM/PRIVACY DOORS FINISHED FLOORS GARAGE FIRf'PROOFING ' DOOR CLOSER(S) SMOKE DETECTORS FINAL ELEC,gRICAL INSPECTION FINAL APPROVAL OF CONSTRUCTION ' it A SIGNED CERTIFICATE OF OCCUPANCY MUST BE OBTAINED FROM THE BUILDING';DEPARTMENT BEFORE THESE/PREMISES ARE OCCUPIED!' REMARKS: • $11/ NOP- SPECTOR TOWN OF QUEENSBURY �ULI BUILDING AND CODES DEPARTMENT BAY & HAVILAND ROADS QUEENSBURY, NEW YORK 12801- TELEPHONE (518) 792-5832 i � 15 BUILDING INSPECTOR'S REPORT I fb`L`'( REQUEST FOR INSPECTION RECEIVED NAME i ( A_>O LOCATION Li Q e DATE _",�'� PERMIT # �—► APPROVED YES NO FOOTING/PIERS ;. MONOLITHIC POUR FORMS FOUNDATION/DAMP,.PROOFING BACKFILL APPROVAL 17 ROUGH PLUMBING XFRAMING }' ELECTRICAL ROUGH-IN INSULATION: FOUNDATION FLOORS WALLS CEILING FINAL INSPECTION: }' CHIMNEY HEIGHT ROOFING SIDING ,y EXTERNAL PORCHES/STEPS \ STAIRS-CLEARANCE, & RAILS\ PLUMBING FIXTURSS/RELIEF \.VALVE INTERIOR TRIM/PRIVACY DOORS FINISHED FLOORS GARAGE FIREPROOFING DOOR CLOSER(S) SMOKE DETECTORS FINAL ELECTRICAL INSPECTION t FINAL APPROVAL/OF CONSTRUCTION ‘ A SIGNED CERTIFICATE OF OCCUPANCYtMUST BE OBTAINED FROM THE BUILDING DEPARTMENT BEFORE THESE PREMISES ARE OCCUPIED! e" REMARKS: INSPECTOR cc�77 /as q rl�+r i Jown o Queenihurcy BUILDING and ZONING DEPARTMENT Bay and Haviland Road, R.D. 1 Box 98 Queensbury, New York 12801 42:93- t. '03 • SEPTIC DISPOSAL SYSTEM INSPECTION NAME A pe,„2 LOCATION 77'/ 92. DATE A/a�/0 7.: PERMIT NO. k) `.Z/ SOIL TYPE Loam - Percolation Required? YES - NO Percolation rate - Min/Inch/ 1- TYPE of SYSTEM: ' Absorption field, total length Length of each trench Depth of trenches ' ' Size of gravel ,SEEPAGE PITS4Nuinber of) %' / Size- E ft. X ' ft. p �' Gravel size' Ar #`3 PIPING: Size Type Bldg. to tank y G ' 50,e -a a Pvc-- Tank to dist. box 6 `T Dist. box to field/r 41 " Openings sealed? NO Partial LOCATION/SEPARATIONS: 7 . Foundation to tank . ft. Foundation to absorption t- Absorption to lot line f Separation of pits ' t. LOCATION OF EM ERTY(circle one) Front - R r -,'Left side - Right side - COMMENTS (I Pi/4, a )/ i . ji SYSTEM USE APPROVED Bui d I spector 01/86 and vl TOWN OF QUEENSBURY BUILDING AND CODES DEPARTMENT BAY & HAVILAND ROADS QUEENSBURY, NEW YORK 12801- TELEPHONE (518) 792-5832 BUILDING INSPECTOR'S REPORT REQUEST FOR INSPECTION RE IVED NAME ✓!` // 1�/-i LOCATION `'l', `, !/'/ DATE c - (I-0 PERMIT # APPROVED YES NO FOOTING/PIERS MONOLITHIC POUR FORMS FOUNDATION/DAMP-PROOFING BACKFILL APPROVAL / LROUGH PLUMBING jy �9.��k- 1��A FRAMING ELECTRICAL ROUGH-IN , INSULATION: FOUNDATION FLOORS , WALLS CEILING FINAL INSPECTION: 1 CHIMNEY HEIGHT \ ROOFING SIDING EXTERNAL PORCHES/STEPS STAIRS-CLEARANCE & RAILS PLUMBING FIXTURES/RELIEF VANE INTERIOR TRIM/PRIVACY DOORS \ FINISHED FLOORS GARAGE FIREPROOFING DOOR CLOSER(S) ; SMOKE DETECTORS FINAL ELECTRICAL INSPECTION FINAL APPROVAL OF CONSTRUCTION A SIGNED CERTIFICATE OF OCCUPANCY UST BE OBTAINED FROM THE BUILDING DEPARTMENT BEFORE THESE PREMISES ARE OCCUPIED! REMARKS: TT; • • /// .tzt(ki INSPECTOR awn of Queenitur, BUILDING and ZONING DEPARTMENT Bay and Haviland Road, R.D. 1 Box 98 Queensbury, New York 12801 BUILDING INSPECTOR' S REPORT NAME LOCATION � , CI Date / / �(� Permit No. '. (o 2 * * * * * * * * * * * * * * * * * * * * * * * ✓ = APPROVED - YES / NO Footing/Pier Forms Foundation Waterproofing Backfill Framing Roofing Siding Masonry Veneer Rough Plumbing Relief Valves Ext. Porches ,, -/ Finished Floors Interior Trim Stairs & Railings Cellar Drain Tile Concrete Floors Plbg. Fixtures Gar. Fireproofing Door Closers Smoke Detectors Chimney INSULATION: Foundation Floors Walls Ceiling FINAL ELECTRI INSPECTION DRIVEWAY APP• JVAL Final Builds g Survey Next scheduled inspection (call when ready) Remarks- pp 7 /� , /5,4 tieye /V uilding Inspector 6/86 and-vl Jouin of Quecniiur1 BUILDING and ZONING DEPARTMENT Bay and Haviland Road, R.D. 1 Box 98 Queensbury, New York 12801 BUILDING INSPECTOR ' S REPORT NAME e W. 4 LOCATION 6 7, g2 Date 5/5". / Permit No. FlC!'�n1%L = APPROVED - YES / NO Footing/Pier Forms Foundation Waterproofing Backfill Framing Roofing Siding Masonry Veneer Rough Plumbing Relief Valves Ext. Porches Finished Floors Interior Trim Stairs & Railing: • • Cellar Drain Ti e Concrete Floor Plbg. Fixture- Gar. Fireproo. ing Door Closers Smoke DetectGrs Chimney INSULATION: Foundation Floors Walls Ceiling FINAL ELECTRICAL INSPECTION DRIVEWAY APPROVAL Final Building Survey Next scheduled inspection (call when ready) Remarks- Building I rotor 6/86 and-vl IMPORTANT: Road all Notes on This Sheet • A copy of this drawing Is to be given to the building • designer(architect/engineer)&erecting contractor. ' This design is valid for Mayors trom tint design date. DESIGN LOAD MBR LEN FORCE MBR LEN FORCE MBR FORCE MBR FORCE DESIGN INFORMATION TOP LL= 50. 3SF 1- 2 6.84 -4824 7- 8 10.48 4202 2-10 -664 '4- 9 2040 LUMBER SOLUTION TOP pL 1 SF3 2- 3 6.82 -4287 8- 9 10.23 3454 3-10 779 5- 9 -1227 The information shown on this sheet has been prepared to be 80T LL= 0. 3SF 3- 4 6.82 -3001 TOP 2X6 #2KD SYP _- used by an experienced woad truss fabricator.This truss has 4- 5 6.82 -3001 9-10 10.23 3454 3- 9 -1227 5- 8 779 BOT DL= ' 10 PSF BOT. 2X4 #10KDSYP been designed to support loads in plane parallel to thetruss.ina OUR pF LOAD INC 1 15 5- 6 6.82 4207 10 1 10.48 4202 6- 8 -664 - • straight and vertical postion based on information provided by SPACING 24.0 IN O/C 6- 7 6.84 -4824 WEB 2X4 #3KD SYP the client.The designer disclaims any responsibility for damages as a result of incorrect information specifications NON—STANDARD LOAD and/or designs furnished to the designer by the client as it May JT LBS SECTION PLF For the condition where @ jt.10 a 5x5 plate is used instead of • relate to a specific project and or failure of materials specified NONE NONE I rr • herein to meet with structural properties published by their 3x4, a in gap is allowed between webs 2-10 & 3-10. AEC CMB= 0.52• AT 9 manufacturers and accepts no responsibility or exercises no JT REACT MIN BIN control with regard to fabrication.handling,shipment and 1 2899 3.50 installation of trusses.The truss has been designed as an 7 2899 3.50° individual building component in accordance with latest revisions of WI and NOS.to be incorporated as part of the building design by a:building designer.When reviewed for . FEBRUARY 15, 1990 approval by the building designer,the design loadings shown must be checked to be sure that the data shown are in agreement with the local building codes,local climatic records THIS DOCUMENT HAS BEEN SUBMITTED AS PROOF THAT THE FACTORY MADE ' for wind or snow loads,project specifications or special applied loads.The design assumes compression chords(top or bottom) REPAIR OF THE TRUSSES MEETS GENERALLY ACCEPTED STANDARDS. WE are continuously braced by rigid sheathing.Where bottom _ _chords in tension are not Tully houlbraced laterally y a properly ACCEPT THIS WITH THE UNDERSTANDING THAT THE RESPONSIBILITY FOR — - applied-rigid-ceilirg,they should be braced at a maximum spacing of10II.o.c...Provide cantinous lateral bracing onwebs , ANY PROBLEMS IN THE F. RE ARE SOLELY ON THE ENGINEER AND and/or chords indicated to prevent buckling failure.Braces t . should be nailed to truss members as indicated.Restrain lateral GUYER BUI ,OERS bracing at ends and at intervals specified by the building designer.Provide a minimum of 3.5 inch wood bearing and i /' adequate anchorage to resist uplift at supports,.Design assumes �' that adequate dmmage is preventpandisg is to be provided by others.Design live load deflection limit span/240 FABRICATION.NOTES 4 /j�s \`ltltit[tff/ Prior to fabrication,the fabricator shall review this drawing to �L � " \\` r /r verify that this drawing is in conformance with the fabricator's /'' • �Y R SELL \��`\` 0 r N E 1 1f7�! plans and to realize a continuing responsibility for such 6 �� ,• �� •`!f verification.Anydiscrepencies are to be put in writingto 3 ��P' •• • '''••, Jam!! designer for corectionbefforecutting orfabriation.Connetor Code Enforcement Officer ,,�� plates shall be manufactured by a single manufacturer specified a a ti ,\' G�,' .p r on this sheet from 20.18,or 16 gauge ASTM A446 grade A or AH aI +CO ;CO G'•• better hot dipped galvanized steel(G60 or G90)•and shall meet 2 6 0 6 ;G+ w ry�� 7.: ,- or exceed plate values specified on this sheet or published. 12 n� n� 12 _ •--. P7 : vir :~?= Plates shall not be installed over knotholes,knots or distorted 6.50 p 0.a a Q 6.50 ^r f�s ` :c- grain.Members shall be cut for tight fitting(wood to wood cz 1 *�- �1 bearing).Connector plates shall be located on both faces of the• 1 7 • =• 1• = -.; ,.. :�r� truss with teeth fully embedded straight in (90 degrees) according to manufacturers specifications and shall be ��� so ,'J',�, � Lam,•'C� symmetrical around the joint.A5x4 plate is5"wide and 4•long. 6 61 �i�J • 0(i1L' �' .` .Slots(holes)run parallel to the ... plate le length spesec The Ilet ngthof the plate le web Jeshots,andrun cphawns i cur.n A e a v J!!!,/4/'v1 J11111e �\•`'\ parallel to the web member.Locate"in panel'splices at 1/4 0 9� f.1 .t. o point of the panel length•9 at locations shown on the truss 60 60 drawing.Consider oversaing the plates for handling.Lumber must bear a grade mark f rem an inspection and grading agency approved by American Lumber Standards committee.and must 10 9 8 be of the size.grade and species shown on the drawing.The . lumber moisture content to be 19%or less at the time of rev.2/6/90 -- _. . fabrication.Double cuts on web members shall meet at the 0/A SPAN 42— 0— 0 (FT. INCHES, 16THS) SCALE= 0.112/1.0 DATE 4/ 5/GB - centroid of the webs.This truss is not to be fabricated with fire retardant or chemically treated wood.For additional information JOB ID GUYt R.AJ on quality control refer to the TPI Quality Control Manual&TPI QCONT iX 4 LAT BRCS NAIL W/2— Bd COM SHEETS OF 8 Recommended Code of Standard Practice.This truss not to be used in a chemical or humid environment. which would Job No. 1286 adversely effect the connector plates and/or lumber,. PRECAUTIONARY NOTES Trusses are to be handled with particular care during fabrication. bundling,storage,delivery and installation to avoid damage. , Temporary and permanent bracing for holding trusses in a • straight and vertical position and for resisting lateral forces shall be designed and installed by others. Careful handling is • essential.Erection bracing is always required during installation to avoid toppling and dominoing.The supervision of the erection or trusses shall be under the control of a licensed contractor experienced in the installation of trusses.Professional advice shall be sought if needed.No loads shall be applied to trusses ' until after all fastening and bracing is completed.Concentration of construction loads greater than the design loads shall not be • • • applied to trusses at any time. Refer to HET-60 for TPI recommendations on handling&erection of trusses. ..___ BRACING NOTES . TEE-LOK(BOCA,SBCCu,FHA & MISC) Bracing shown on this drawing is not erection bracing.wind CONNECTOR PLATE VALU ESt Fy'40k bracing or similar bracing which is part of the building design PSI OR PLI PER PLATE (GROSS, and which must be considered by the building desinger.Bracing A�+ LAT.SHE.TEN. LAT.SHE.TEN. shown is to reduce buckling length of truss members only. G11i7AN ENGINEERING GINEERING T-GIG 20ga. TL-ST 20ga. Additional bracing of overall structure may be required.For 339 S.W. 18th TERRACE MAX. 230 426 419 224 419 461 specific truss bracing requirements contact building designer. MIN. 159 248 403 172 236 344 Refer to BWT=76 for TPI recommendations on bracing.(Truss E-GIG 18ga. T-L-S 16ga. Plate Institute.TPI is located at 583 D'Onoforio Drive suite 200. MIAMI, FLORIDA 33129 . MAX. 230 602 558 200 623 894 • Madison Wisconsin 53719) MIN. 159 272 537 136 428 449 Any exceptions to the above are noted on this drawing. TLK neL.TPI Copyright®1986 by lqbal Gagan.P.E. QUEEN VICTORIA' S GRANT QUEENSBURY, NY C.O.T. G. M REFERENCE DRAWINGS 5A SITE UTILITIES SEPTIC 4 WATER VanDUSEN 4 STEVES SURVEY PLAN 6'-0 DIAMETER 9'- 0 DEPTH 2000911 u 142.94 C O.TG. (C TO GRADE) LEAN OUT 1 PLOT PLAN 4 SEPTIC SYSTEM GUYER BUILDERS, INC QV-22 DWN ; kW 12-15-07 Scale 1"20' 0