ChecklistReport002-01-24 112313 (1)
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: SEP-0596-2022 Case Module: Permit
Inspection Date: February 01, 2024 Inspection Status: Passed
Inspector: Mark Smith Inspection Type: Septic
Job Address: 185 JENKINSVILLE RD
, Parcel Number:
Contact Type Company Name Name
N/A
Primary Owner N/A
Granted Permission N/A
Engineer N/A
Checklist Item
Status
Building Inspector notes
2/1/24 final inspection for septic system approved - as built drawing received.
PASS
Roof gutters don't discharge over leach
field PASS
Soil type: loam PASS
Type of water: municipal or well water well water supply PASS
Waterline separation distance PASS
Well casing length 50 ft. more or less PASS
Total length of absorption fields 140’ FAIL
Septic system field above field plain PASS
Sump pump not connected to septic
system PASS
Water softener not hooked to septic
system FAIL
Length of each trench 4 laterals at 35’ each PASS
Depth of trenches 16/20” PASS
System use status PASS
Distance from building to tank 10’ PASS
Distance from tank to d-box PASS
Opening sealed PASS
End cap PASS
Inlet outlet pipes and baffles, provide
extension collar if yes PASS
Locations and separations PASS
Distance from foundation to tank 10’ PASS
Distance from foundation to absorption
field 33’ PASS
Stone size # 2 PASS
Size of tank 1000 gallon septic tank FAIL
Conforms as per plot plan PASS
Engineer report and as-built PASS
Location of system on property PASS
Well separation distance PASS
Mark Smith
Code Enforcement Officer