Loading...
INSPECTION WORKSHEET 03012024 INSPECTION WORKSHEET Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number: RC-0309-2021 Case Module: Inspection Date: March 01, 2024 Inspection Status: Passed Inspector: Mark Smith Inspection Type: Residential Final Job Address: 23 KNOLLS RD NORTH , Parcel Number: Contact Type Company Name Name Owner N/A Thomas Ormsby Checklist Item Status 5/8" Type X with Living Space Above PASS Emergency egress below grade walk out basement PASS Heat detector in garage PASS Gas Shut-off Exposed & Regulator 12" min abv grd PASS Fresh Air Intake PASS All Hot Water Systems: 3/4" or larger piping R-3 PASS As Built Septic System PASS Battery backup PASS Roof Complete / Exterior Finish Complete PASS Furnace shut-off w/in 30 ft. or w/in line of site PASS Not less than 3' horiz from opening of bthrn PASS Guard at stairwell at 34" or more PASS Jack posts in basement lagged at top and bottom PASS 3" Plumbing Vent through roof minimum 18 inch PASS CSST/other piping in conduit if buried,if required PASS OK to Issue Temporary C/O PASS Outside Spigots have Air Gap PASS Relief Valve ,Heat Trap/Water Temp 110 deg or less PASS 1/2" Gypsum or House Wall and Gable PASS Handrail 4 or more risers PASS Gas Log In Sealed or Glass Enclosure PASS Inter Connected PASS within 10' of all sleeping areas PASS Fresh air supply 3' from grade PASS Plumbing fixtures complete work in master bathroom PASS 4 inch Building Number Address visible from road PASS Fin Elect; Energy Saving Light Bulbs 90 Percent PASS Duct work sealed properly PASS Smoke Detectors: PASS Outside every bedroom area PASS Window guards req:<2' above floor/6' above grade PASS Guards at stairs,decks,patios 30" + above grade PASS Attic Access 22 x 30 minimum PASS Attic Access Gasketed PASS Bathroom / Kitchen Watertight complete doors and trim at interior PASS Grade away from foundation: 6" down, 10' out PASS Interior privacy/trim/doors/main entrance 36 PASS Arc Fault Breaker Habitable Spaces PASS Carbon Monoxide Detectors: PASS 6" clearance to sill plate PASS HVAC Vent Terminal 10' from Lot Line & Openings PASS Foundation insulation to floor PASS Chimney Height / B Vent / Direct Vent Location PASS CO in bedrooms w/gas appliances PASS Seals on Garage Doors, esp. Wood PASS Low flow toilet 1.3 gal/flushing cycle PASS Blower Door Test Certification PASS 20 Minute Fire Door/Self-Closing Hardware PASS Platform at all exterior doors PASS on all levels w/gas appliances (i.e. furnace) PASS Dryer Duct Max Length 35', Labeled Over 35' PASS Flex Gas Pipe Bonding PASS Furnace/Hot Water Heater operating PASS Basement stairs closed rise greater than 4 inches PASS Attic Access Insulation = Attic R- Value PASS Every level, Every bedroom PASS OK to Issue C/O PASS Propane Tank: Proper Setback from Prop Line/Struct PASS Bathroom Fans, if no window PASS Handrail Termination at Newell Post or Wall PASS Basement wall insulation R- value verified PASS Guard at deck, porches 36" or more PASS Final Survey Plot Plan submit final survey PASS General Comments 11/13/23 partial approval for final residential inspection. Approved for temporary Certificate of Occupancy only. Complete the items listed below for final approval. -Complete siding and exterior trim. - install permanent stairs at interior garage entry. -complete work at master bathroom. -Submit blower door test results. -Submit final survey. -Install permanent counter tops in kitchen. - Final inspection for gas fire place. - Final inspection by Code Compliance Officer Bruce Frank will be required. 2/22/24 final inspection for single family dwelling not approved. items remaining - blower door test results - submit final survey. 3/1/24 final inspection for signal family dwelling approved. - items listed above have been received. PASSN/O Mark Smith Code Enforcement Officer