95-485 :CERTIFICATES: OF OCCUPANCY •
TOWN. OF.QUEENSBURY y`
WARREN,.:,COUNTY; NEW YORK
Nov_e
mber,.27 199.5
This .is ;.to certify that work requested- to:be done as shown by Permit No: 9 548 5
has been completed.
SINGLE FAMILY 'DWELLING- W2-CAR:`•A.TT GAR.AGF
Thin structure-may be occupied:as a:
LOT 3'7 C'IIAPI'1AN-.COURT' ` '.
Location.
Owine�' ti LC'IiAEI�:'i",.GROUP
TAX tiPaP NO. 14'8'.:-3-3:7
By Order Town Board: :' -
TOWN OF QUEENSBURY
/,
Director:of Bldg.:ac"..Code .EnfOee,ment
BUILDING- PERMIT
VALUE $ 138000 TOWN OF QUEENSBURY No 95485
TAX MAP NO. 148. -1-37 -
WARREN COUNTY, NEW YORK
MICHAELS 'GROUP
PERMISSION is hereby granted to
LOT 37 CHAPMAN COURT
OWNER of property located,at - - • • Street, Road or Ave.
in the Town of Queensbury,To Construct or place a SINGLE FAMILY DWELLING W2-CAR ATT GARAG
at the above location in accordance to application together with plot plans and other information hereto filed and
approved and in compliance with the Town of Queensbury Building and Zoning Ordinance.
1. OWNER'S Address is
6 CENTURY HILL
LATHAM, NY 12110
2. CONTRACTOR or BUILDER'S Name
MICHAELS GROUP
3. CONTRACTOR or BUILDER'S Address
6 CENTURY HILL DRIVE
LATHAM, NY 12110 0
4. ARCHITECT'S Name
NYB
5. ARCHITECT'S Address -
6. TYPE of Construction—(Please indicate by X)
SINGLE FAMILY- DWELLING
( )Wood Frame ( I Masonry ( )Steel ( )
7. PLANS and Specifications .
2801 SQ0.FT SINGLE FAMILY DWELLING AS_PER PLOT PLAN -SPECIFICATIONS .
8. Proposed Use
SINGLE FAMILY DWELLING W2-CAR ATT GARAGE
$ 374 PERMIT FEE PAID —THIS PERMIT EXPIRES August 31 19 97
(If a longer period is required an application for an extension must be made to the Building and Zoning inspector of the
town of Queensbury before the expiration date.)
Dated at the Town of Queensbury this 1 Daytof September 19 95
SIGNED BY '\.vim for the Town.of Queensbury
Buil ing and o ng Inspector
3
1.
• TOWN OF4 QUEENSBURY REVIEWED BY _
COMMUNITY DEVELOPMENT. DEPARTMEN'1' � ;' '
BUDDING & CODE ENFORCEMENT FEE PAID: R 4-691"
531 BAY ROAD
QUEENSBURY, NEW YORK 12804 PERMIT NO. • ^0 ) 1 S
(518 ) 745-4447
BUILDING PERMIT APPLICATION
R
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. NO INSPECTIONS
WILL BE MADE UNTIL APPLICANT HAS RECEIVED A VALID BUILDING PERMIT.
All applicants ' spaces on this application MUST be completed and the
signature of the applicant MUST appear on the application form.
OWNER OF PROPERTY: The Mic.hae,P.A D eveP.op m ewt Gnoup •
Mailing Address : 6 Cewtwuy HAE Dn%ve, Latham, New Yonh. 12110
Telephone Number( )Work 7gs-9641 Home Other
PROPERTY .LOCATI1 I 3n. ChC maw C-0 UP t
Tax Map Num}Jer: Section J25c' Block / Lot 3/
Subdivision Name: Had6on Po-inte Lot No . .�
NATURE OF PROPOSED WORK: • ESTIMATED MARKET VALUE OF THE
CONSTRUCTION: $ ► 3 ,OO
x NEW BUILD NG:
CESIDENCEJ COMMERCIAL OCCUPANCY INFORMATION:
ADDITION TO BUILDING: PRIMARY BUILDING - .
RESIDENCE/COMMERCIAL X Single Family Dwelling •
ALTERATION TO BUILDING: Two Family Dwelling
• RESIDENCE/COMMERCIAL Family DcREe-Ei vQED
(NO CHANGE TO EXTERIOR SIZE) Office f"1 m�
OTHER WORK (DESCRIBE BELOW) Mercantile
Warehouse AUG 21 1995
Manufactur_ng
_ Other TOWN OF QUEE,NS€'URY
GROSS AREA OF PROPOSED STRUCTURE: BUILDING AND CODE
• . 1ST FLOOR /(p°Ori SQ. FT.. POI/
IF ADDp TION, USE OF NEW ADDITION:
2ND FLOOR / �! * •SQ. FT. l 35 w
OTHER FLOORS 0 SQ. FT. 399
' (not unfinished cellar or basement) ACCESSORY BUILDINGS :
Detached Garage - One/Two Car
TOTAL FLOOR AREA: . 2' / SQ. .,T. ,/^ Attached Garage - One(Two)Car
Private Storage Building
SIZE OF NEW STRUCTURE : • Commercial Storage Building .
• Other
62- FEET X i'2 FEET .
Foundation Type: FA1 (2q 2rTIQnt Will any second-hand or ungraded
Number of Stories : lumber be used? If so, for what?
(habitable space only) 2 ()
/ J Height (grade to ridge) : O feet TyP of Heating System:
Number of fireplaces and/or woodstove (circle all which a plies )
to be installed: 1 Electric / Oil / Gas / Wood
Forced Hot Air / Baseboard / Other
• PJRSQ an SPUSIB E FOR�SUPERVISION OF WORK AS REGARDS TO BUILDING CODES IS :
m •
NAME OF BUILDER/ADDRESS/PHONE : The Mi.chae.s Deve,2op. •Gnoup, Latham, NY. 12110 .
' NAME OF PLUMBER/ADDRESS/PHONE : Fava P.eumbdng, 16A Patk Rd. , Ute,0 f aLLS, NY I.9S-4399
NAME OF MASON/ADDRESS/PHONE : I D a,nnohoh, Any 968, G a vic�,Pp
NAME OF ELECTRICAN/ADDRESS/PHONE : Ponevet. Lax.. - 13oe 2446 ia6okey St. Sch'dy, NY 3/1-99'L''2
DECLARATION
To the best of my knowledge the statements contained in this appli-
cation, together with the plans and specifications submitted, are a true
and complete statement of all proposed work to be done on the described
t:• � 9.UUU I1LI,'1'J_ G UEGl}1>a'E UAY
Compliance McLl ads : i'nit'1.' 5 - Acceptable Practice Method -
I.&7, N1.-i Dwel 1 iiy ( only )
1.'11it'1' li k -- Thermal RuLiilg - Component: 'I't:m o U. I�
.i&7,. lrumily Dwellings; MulLI-.i amil,y
Dwellings (3 Stories or less )
PART 4 * •- Design by Component Performance
Commercial Buildings-U3, Rise Residential
*Requires rnl.)inissivtl of worksheets
APPLICANT' S NAMI!: : I•'RoVEH'TY LOCATION :
1-n2. nThCbaQ\S c rq4 --- - P3-1 C pme COut '---. .--
PART 5 METHOD OF COMPLIANCE BY ACCEPTABLE PRACTICE :
1 . Gross Floor Area - _— -- �._._...__ square feet
2 Type of Heat Elec:Lr u Via. .,_X_ Gas OI_Iter,
3 . In building mechanically cooled? Yes h( No
4 . Percentage of area of windows and doors Over 17% Under. 17%
5 . R-VALUES FOR INSULATION GIVEN >~ eLOW MUST CORRESPOND 'I'O R--VALUES AS
SHOWN ON PLANS SUBMITTED:
a . Roof R _ 30_
b. Exterior wallsIt �C�
c . Glazed a)'eari
d . Exterior doU t.n R
e . Floors over unheated spaces It __-,-) 9
f . Edge of slab on grade ( heated building) R
g . Basement/cellar wails (above grade)
!i . Basement/cellar wa.1..1.s (below y.rade) Iti . Heating/cooling-ducts-piping in unheated space R ---
6 . Service (domestic) hot water heating device
Conforms to minimum efficiency per code - )_ Yes No
TEMPERATURE CONTROL MAXIMUM SETTING 1400 -- HILL NOT BE ExCEEUEU
Applicant ' s Signature Date Phone Number
-L- 1 tqG 3 .._ -1 Fc 3-Ci e(4._ _.
INSPECTOR' S REMARKS
oftin of (quftri &u 5`� S 1'�J �TghfU2lg �P�?Ml'fITIPrit
9/t go
Bay a't Havlland Roads Office Phone 518-793-7771 Oueensbury, New York 12801
PAUL H. NAYLOR - RICHARD
A MISSITA
Superintendent Highways Deputy Superintendent Highways
DRIVEWAY PERMIT
DATE: I�S�, Iqq
APPLICANT NAME: --�n(2 1r1tr \c Q\ C—TR O U P
TELEPHONE NO. : ' b g -- � ��` - q(,o(..I. 1
ADDRESS TO BE INSPECTED: 3°) C\c rr c, (-) C1c r-1.
RETURN ADDRESS: (,c C.Q.r- c y \I (T(� , (.,C*\G t'rl
ivy / 2U0
Applicant must show exact location and width of driveway(s) to be connected
to the highway by placing stakes at the specified location.
The Superintendent of Highways, Town of Queensbury, has reviewed the application
of the above named resident to connect a driveway to the Town road. The
following action has been taken:
STEP 1: ( ) Preliminary Approval
NEED: ( ) Slight Swail •
( ) Level With The Road
( ) Deep Swail
Size Pipe to be used (if necessary)
( ) 12" ( ) 15" ( ) 18" ( ) 24" ( ) 36"
Preliminary inspection by DATE
Approval by Highway Supt. Depty. Supt.
After receiving the Preliminary Approval , submit the permit to the Town of
Queensbury, Highway Department upon completion for a Final Approval .
STEP 2: ( ) Final Approval
( ) Rejected
DATE:
•
PAUL H. NAYLOR •
Superintendent of Highways
Town of Queensbury
•
•
'(SEPTIC' DISPOSAL
I,uc:rt rrt of pro fot hist:aIIa iott:. 13'--) chap mo rTh
I,N.Rt1I r,titom. '.
Owner's Name: THE I.4ICHALLS DEVELOPMENT GROUP
Address: 6 @en-tuny Hitt Dnive _ Q
Installer's Name: Cha'z e. Excavation
Excava �on 1:1;1:• !'All)
Phone #: (51 i) 639-4035
Number of bedrooms (if residential): bednoomd
Total daily flow (residential - compute (ir 150 gal. per bedroom): _ Go®
Topography: ( X I Flat I Rolling ( ( Sleep Slope gie of Slope
8 ' - 0"
Soil Nature: I X Sand ] Imam ( I Clay Other /Depth:
Ground Water: at what depth? A p pnd X 30 feet
Bedrock or Impervious Material: at what depth? None feet _�
65 Sec,
Percolation Test: ( Not Required I X Required/Rate 1 min. per inch
• Donretic Water Supply: [ )—(71 Municipal ( [ Well [ 1 Other
If domestic water supply is a WI.I.I.: water supply front any septic absorption is feet
I'ROPOSI;I) SYSTEM:
Septic tank: 1.2.50 gal. (minimum size: 1.000 gal.)
•
Tile Field: each trench S / feet. / • total system length /le211ect. •
•
•
Seepage Pit(s): number of NIA _ / size each: It. x ft.
Size of stone to be used: # 2 d UYle l depth or thickness fcet.
HOLDING TANK SYSIEM: (if required)')
Number of tanks: N/A Size or-each: gal.
! ,' Alarm system and associated electrical work to be inspected by a certified agency.
For your protection, please note that pursuant to Section 136-29 of the Code o fibe Town of
Queensberry, any permit or a p proral granted which is based upon or is granted in reliance u you
any material misrepresentation or failure to make a_ material fact or circumstance known b v or on
behalf of an applicant, shall he void.
1 have read the regulations with respect.to this a p.plication and agree to abide !r r these and all
requirements Y•err+'n er f Oreee•n.1hrrry .Serrritary Seu ape Uicjrercal Urelin,ne e.
• Sienauere eel re.cpnn.crhle.'nerson: Hate:
• �r
TOWN OF QUEENSBURY
531 Bay Rd., Queensbury, NY 12804
APPLICATION FOR SOLID FUEL BURNING APPLIANCES AND CHIMNEYS
Date ,19 } Permit No.
APPLICATION IS HEREBY MADE to the Building Dept. for the issuance of a Building and Use Permit
pursuant to the New York State Fire Prevention and Building Code. The applicant or owner agrees to comply with
all applicable laws, ordinances, regulations, and all'conditions that are part of these requirements and also will allow
all inspectors to enter premises to perform required inspections.
Please fill out additional form if more th(n one appliance and/or chimney.
Applicant j rr',r�� ; ( 40ui, APPLIANCE (check appropriate boxes)
.
Address l4l y 7,1 // ❑ STOVE: ❑Wood o Coal o Pellet ❑ Gas
0 FIEPLACE INSERT
Lr7't CLit jlj Zip (77/(j- 0-FIREPLACE; FACTORY-BUILT:
0-Wood ❑ Gas
Phone 0 FIREPLACE, MASONRY:
❑ Wood ❑ Gas
Owner 0 FURNACE: ❑ Wood .n❑ Gas ❑ Oil
ki Address ' '-; 7 ('/;')04/ t(,) ((AA IF NON-MASONRY APPLIANCE:
. I Manufacture_r:. ��n f'��!r
t
(,i(,-0P, i% r Zip ( 210/ Model:
Phone 1(. 1 i(, L// r"
CHIMNEY (check appropriate boxes)
*EXACT ADDRESS of prop -sed 'coristruction
t' -114 0 MASONRY: 0 Block 0 Brick 0 Stone
FLUE: o Tile ❑ Steel
Size: inches
CONSTRUCTION / INSTALLATION MUST 0-FACTORY-BUILT:
CONFORM TO NYS FIRE PREVENTION & Manufacturer: Model:
BUILDING CODE. CONSULT AVAILABLE Listed By: Number:
TOWN OF QUEENSBURY HANDOWTS• o--Double Wall ❑Triple Wall
REGARDING REQUIRED INSPECTION§. 0 Insulated 0 Direct Venting
Cashier's Department Town of Queensbury, New York
Dept: Fire Marshal Amount Collected Amount Received
Code Number Title
A 173 3389 (190) Public Safety
A 233 2655 (230) Minor Sales
-Fee Collected From_or Refunded to: N� �-\CA n ( ';;�
Add-ress:- =
Dated: -- l .- Town Clerk or Deputy:
White: Applicant Green: Fire Marshal Yellow: Bldg. Dept. Pink & Goldenrod: Cashier's Dept.
JOHN L. HAANEN, RE.
THOMAS THOMAS W: NACE, P.E.
August 9, 1995
Jim Chandler
The Michaels Group
- 6 Century Hills Drive
Latham,NY 12110
Fax: 798-8182
RE: Hudson Pointe PUD
Percolation tests
Dear Jim,
In accordance with the PUD approval for this project we have performed site specific
percolation tests for lots#35, #37, #39 and #40. These tests were performed in the area
of the lots where the septic systems will be located according to the plans.
The stabilized percolation rates are as follows:
Lot#35 1 minute 10 seconds
Lot.#37 _ 1 minute 5 seconds
Lot#39 2 minutes 10 seconds
Lot#40 1 minute 5 seconds
These tests were performed on August 9, 1995.
Please call if there are any questions.
Sincerely,
G. Thomas Hutchins, PE
_____ 253 BAY STREET,QUEENSBURY, N.Y. '12804
■ !•'.' TEL: (518) 793-7444 FAX: (518) 793-7061
N E W YORK STATE ENERGY
CONSERVATION CONSTRUCTION CODE
PART 5 COMPLIANCE FORM
Building Design by Acceptable Practice
BUILDING
ADDRESS: Go.7'7 Ci/1dr ban. G. DATE: p/j,jg5
//�y�, , ma�yy,, �� ,-
v1i7/�-17fAj .QG JI/5eI COUNTY: ( }fS':fZ (f
ARCHITECT,ENGINEER,OR
CONTRACTOR THE 6'20 UP PHONE: 518-7 8 3-9 6 41
PERMIT APPLICANT_ ShirjG PHONE:
I. HEATING DEGREE DAYS (Table 2-1)
5000-6000 X 7000-9000
II. BUILDING DESCRIPTION (Pre-qualifying Conditions)
If the building does not meet all of the following pre-qualifying conditions,
• Part 5 of the Energy Code may not be used.
Building is residential with-one or two dwelling units. _
17 Building is less than 5,000 gross square feet.
X Building is three stories or less in height.
Xj Ratio of glazing area to gross wall area is equal to or less than 17%.
III. PROJECT TYPE
1'X j New construction Substantial renovation of existing building
Addition to existing building Exempt (7810.6c)
IV. HEATING SYSTEM TYPE _�`' '
x I Gas-fired Oil-fired Heat pump Electric 44A
V. BUILDING ENVELOPE DATA: 7814.2
Envelope Component Minimum Provided Plan/Spec.
Required Reference
Exterior wall R= 18 R= 18.01
Roof/ceiling R= 24 R= 29.4
Floor R= 19 ,
R= 30 .5
Foundation wall R= 10 R= 13.57
Slab edge insulation R= i o R= N/A
GIazing R= 1.7 R= 3.3
Entrance door R= 2.5 R= 10
Insulated depth below grade D= 48" D= 48"
Skylight R= 1.7
R= 3.8
Skylight %of total roof area 1%Maximum %= < 110
•
Vapor Retarder: 7814.2(c)
Location Location Type Plan/Spec.
Required Provided Provided Reference
Walls Yes Poly
Ceiling Yes Poly
Floor Yes 3/4" OSB .5 Perm
Other
Infiltration Rate: 7814.2(h)
EIement Maximum Rates + Rates Specified Plan/Spec. Reference
Windows 0.37 cfm/lin. ft. _12
Doors 0.50 cfmisq. ft. Patio _12 Swing .04
5
Joint Sealing: 7814.10(i)
Joint Location I Sealant Type Specified Plan/Spec_ Reference
Windows Polycell
Doors frames Weatherstripping
Walls at roof/ceiling
Pal yrel l
Walls at floors/found. Polycell
Wall panels N/A
Utility entrance Weatherstripping
Penetrations Polycell
Other
Other
'Air Infiltration Barrier: 7814.10(j)
Location Required? Specified Plan/Spec. Reference
. Walls yes/no No-cedar Siding
Other yes/no
Fireplace: 7814.10(k), (m)
Required I Specified Plan/Spec. Reference
Outside combustion Yes-
air duct with damper
Flue damper with max..20 cfm, or
damper and non-combustible doors damper 20 c.f_m.
Gas fireplace ignition No
VI. HVAC PERFORMANCE: 7814.11 (Table 5-3)
Equipment Minimum Performance Specified Performance Plan/Spec. Reference
Furnace 70% AFUE 90%
Boiler
Heat pump
Central air
conditioner J
• VII. HVAC CONTROL: 7814.12
Temperature Control
Required I Specified ( Plan/Spec.Reference
Thermostat each Yes
dwelling unit
Shut off at each '
terminal unit Yes
Thermostat
Required ( Specified ( Plan/Spec. Reference
Minimum range Yes _______
45°F-85°F
Deadband Yes
range >_ 5°
Automatic
•
capability Ye'
VIII. DUCT SYSTEMS: 7814.13
Category ( Required Provided Plan/Spec. Reference
Duct >_ 1"thick N/A in conditioned space
insulation R-33 in uncondtioned space
Transverse Sealed Yes
joints
i ,
IX. VENTILATION SYSTEMS: 7814.14
System Type Required ( S ecified
p Plan/Spec. Reference
Supply Damper at envelope Y
es
Exhaust Damper at envelope
Yes
Supply on/off switch
Yes
Exhaust - on/off switch
Yes
i
i
4.
' ' X. PIPING INSULATION: 7814.15
Piping Type Insulation Provided Plan/Spec.
Required Reference
Heating distribution* >_ 11" I N/A
Service hot water** 3,4" I N/A
*Does not apply to runouts.
**Does not apply to piping with a diameter less than or equal to 3'4" inch.
XI. SERVICE WATER HEATING: 7814.21 (Table 5-4)
Performance Requirements
Water Heaters Minimum Specified Plan/Spec.
Performance Performance Reference
Storage Et. ) .93 -.00132V I > .93
i
Instantaneous N/A
Pool
N/A
•
- Controls
Category Required Control Control Provided Plan/Spec.
Reference
System automatic control Yes
System temp. setting range 140 degrees max.
Pool heater HD N/A
Pool heater on/off switch N/A
Electric water heater separate switch N/A
Gas/Oil water heater separate valve Yes
XII. ELECTRICAL POWER: 7814.31
Category Required rifled I Plan/Spec. Reference
Electric meters Ea. dwelling unit
-r
EXTERIOR WML
OPA0UE FRAMED WALL: 'ORKSMEE7
R-Value
insulated i R•Value
Construction Framed
Area Component
11:11-44P14:
. Area•
0.681nt• Air film 0.68 ! iJ'Zi
.45 1/2" Gypsum Bd. ! .45 Milt!ii (mil.
� Wallboard � I� IJ/ - 1
19.00 . .� tt ---- I+ `1
.-7'nsul ation �. , ����,
---- 2x6 @ 16" o.c. 6.87 IIIV//;.-
..• Studs . •
.54 I II � �
il.-Ma
1/2"Sheathing .544111101"- i ��
▪ . Sheathing \
.65 . Vin 77 I \,EMI y5iding . . . ..65. . 110.1 7 G
Ext Air F;lm i 0.77
21.49 i
R•Total I 9.36
U Insulated Fraction*
Framaa Fraction*
R-Total Insulated
R-Total Framea
U RS
w . 285__.49 + .15 :
•
9.36 .056
•
* Wall Stud Spacing Insulated Fraction f Framed Fraction
I
12" 0. C.
.d3 . • . 77
16" O. C,
.85
. 15
2k" O. C. .815
. . . 12
-
BASEMENT/CELLAR MALLS: WORKSHEE'
@ stairwells
R-Value I R-Value
with Ext. Construction 1 with Int.
Insulation Components l Insulation
•�•4 , I 0.7 7 I I .• •.- .1
►���� : : ::: 5h
•011111111111B •• n ►♦♦j •
►♦♦♦ ►dui
�� g Poured ,.4
►���� • Hlock (Concrete ) ; , . ,1...72. . . , "• . ��
♦�° ) Core Insulation
•
6 ► ♦•4
♦ I ♦,:
t ►♦{ •-
►:♦: . �(i f any) = 1_�� •-►:♦::
. ►♦�♦ I I.
I'lIZ R- 1�`- : -.�♦':
��1 Insulation .10.� ♦�:
(l 4.
JP 4 (ext. or i nt. ) �O' � 1. ►♦��
1.-►�4 None • t[ .= :-
:IAA Interior Finish _, • � .�.,:
►♦•+ •• . 0.68 0.6 8 4f
Int' Air Film •
R-zeta 1 /3 -37
U
w R-Total
•
' U - 1
- D7q
w /3-31.
Exposure Above Crade = 8 II
Depth Below Grace = 48II
r
•
ROOF/CEILING (VENTED) : i'ORKSHEET
•
/ i,
( ( III \f Y li. ‘I l' . '('
R-Value R-Value I
'• - Insulated '
Construction Framed .
Area 1 Components Area
•
' . 0.17 Ext. Air Film 0.17 ' I-
I '
30.00 ; 9" Batt I ---- 12.00 Overlap •
Insulation
2x4 bottom chord
@ 24" oc 4.35
Joists
•
• .45 1/2" Gypsum Bd. .45
. .. . Wallboard
0.61 I
J Int. Air Film 0.61
31.23•
R-Total ! 17.58
• Insulated Fraction* Framed Fraction*
r ■
R-Total Insulated
R-Total Framed
u _93 .07
r ■
31.23 17.58 _034
•
* Roof Joist Spacing Insulated Fraction Framed Fraction
12" O.C. . 87 . 13
16" 0.C_ .90
.10
24" 0.C. .93 I .07
1
r
•
BASEMENT/CELLAR WALLS: WORKSM£E-
•
R-Value ' R-Value
with Ext. ) Construction I with Int_
Insulation Components ! Insulation
• �:♦I Ext. Air Film • 0.77 e:NoneExterior Finish : t4.
• ♦♦ B1oct (Concrete ) , ..L.-7,2, . "- - ♦j�
•
Core Insulation • ♦♦,:
►�♦� I i
�►.♦♦� • • (if any) •.►�♦�
♦:♦I • I - ?��/z t w,u1. I1. .-. . - ♦�
�1
Insulation --t 0- ♦♦:
♦� (ext. or i nt. ) -i. • ;1
1-,o•l-- - None . • If : j♦�
II0.4 - Interior Finish a
►♦♦+ . . 0.68 . •I.- ►♦�
Int, Air Fitt., 0.68 __.. . - •
I ♦♦: ~
I
13.57
R-Total
U - 7
w R-Total
1
Uw & 13 .57 .C74 .
Exposure Above Grade & 8 N
Depth Below Grace w 48
t
4 •
OPACUE FRAMED F.00R: KORKSME_'
.' if V (\;1 ,r- r- -:, v.! \, . , —,_ .-
\ c.„---
i. , ,i .i,
2 -) \. ,)
., / ; / , /!/( / it: ,
1 YA.)
. •
-� ,, -
.,/
.,,, )(c_ ,-----'
' R-Value ` _ �� ,• /
• R-Value
i ! Insulated Construction Frame° i
•• ' Area Cca•ponents - Area
•
i ,
0.92*
Ext. Air Film 0.92*
19.00 6" Batt
•
• • • - • Insulation
11 7/8" TJI's @ 24" o.ci
i . . .foists 14.84 —
J 3/4" waferwood i
i .93
I . . . . Sub-Floor . .. ..P ..n :... carpet vinyl f
i . ... i n. Floor . nil:.
0.92 0.92
Int. Air Film
21.02 I R-Total 16.86
U = Insulated Fraction** Framed Fraction**
o
R-Total Insulated R-Total Framed
Uo = .95 + .05
21.02 16.86 .048
* For vented crawl space, use R = 0.17 for ext. air film.
** Floor Joist Spacing Insulated Fraction Framed Fraction
12" O.C. .87 .13
16f° 0.C. .90 .10
: " U.C. .93 .07
!�,ib�t/-1tr,�tr_)tr,�tr;�Q,�tr,�ti,�tr,�h-�ti,)h�h M l• ti .Ir�h �tr,�h,�tr„Ai,�6,�Ir Nr �tr A�„h„fib,fib,�t/.\tr.�tr,A/,?t/,)tr tt,��r �tr lt. �tr Nr �b Or A • A� ttr •i,fit)„�tr,(tr .• .h rh„��
THE NEW YORK BOARD OF FIRE UNDERWRITERS [-'AGE 1 o
ii'�; BUREAU OF ELECTRICITY ®
r } 111 WASHINGTON AVENUE,SUITE 704,ALBANY, NY 12210 • !al
igOT E,I1BI R. 21;1 35 Application No.on file '15?48795/.:.'5 A 112928
v Date _.
PERT-11'r HO. 95-4815
THIS CERTIFIES THAT
only the electrical equipment as described below and introduced by the applicant named on the above application number in the premises of
Tilt, .MICHfo:.LS GROUP, Ti C'iIAPMAN C°T.-[il.ill,SON (?oJ i'i.E, NEENSBUSR`/', N.Y.
r
in the following location• [ .Basement _ D 1st Fl. " 2nd Fl. •
v�i Section Block Lot
was examined onNOVISIti and found to be in compliance with the National Electrical Code.
RXTURE RECEPTACLES SWITCHES FIXTURES RANGES COOKING DECKS OVENS DISH WASHERS EXHAUST FANS
Ex OUTLETS INCANDESCENT FLUORESCENT OTHER AMT. K.W. AMT. K.W. AMT. K.W. AMT. K.W. AMT. H.P.
® 5 60 34 25 1. • 1._ .1. . `_i 3 'H
v DRYERS FURNACE MOTORS FUTURE APPUANCE FEEDERS SPECIAL REC'PT. TIME CLOCKS BELL UNIT HEATERS MULTI-OUTLET DIMMERS
AMT. K.W. OIL H.P. GAS H.P. AMT. NO. A.W.G. AMT. AMP. AMT. AMPS. TRANS. AMT• H.P. SYSTEMS AMT. WATTS
-AMT. No.of FEET
® 1
. .0 1.
SERVICE DISCONNECT NO.OF S E R V I. C E
AMT. AMP. TYPE METER 1,�'2W 1$3W 3/3W 3,B AW NO.OF CC COND.: A.W G. NO.OE HI-LEG A-W.G• NO.OE NEUTRALS A.W.G.
EOUI►• PER d OF CC.COND... OF We OF NEUTRAL
®® 1 15C0 CB 1 Y. 1 2. r0• :[ 1/0
OTHER APPARATUS:
1 G.F.C. I;-2 SPOKE DETECTOR;-6 DETECTOR;-6 -
....L 0..4, ...M.1 . C
FOREVER ER HLEC/?OEL ELECT. , LTC.#2c�:
:v.c.Lrr.,:r 11 D. tIl'1:R'cr.:�PI !AZ der �
'244E JAFSCHNECTADL;, SY, BRANCH MANAGER
NY 12309
.1 - Per ':
This certificate must not be altered in any manner;return to the office of the Board if incorrect. Inspectors may be identified by their credentials. .
Li -acr• EIMISSEMIIIIIIMEMEINIEMESESIE5ESMEEINELSOMMISEISEEItINIMMIVI ® rrwr M WI WI rl flii • • -•
COPY FOR BUILDING DEPARTMENT. THIS COPY OF CERTIFICATE MUST NOT BE ALTERED IN ANY MANNER.
3 c iyv...;,y,..:,:,: , .. .:::77.,:::.„;‘,!of ______._.
TOWN OF QUEENSBURY
�1 BUILDING & CODE ENFORCEMENT
# � � ,' 742 BAY ROAD
:' •4r QUEENSBURY NY 12804
��'rr a � (518)745-4447
ARRIVE: ✓ DEPART: 5 ' " INSP:�
FINAL INSPECTION REPORT — RESIDENTIAL ";
DATE INSPECTION REQUES RECEIVED: \ \ — 2 1 2
NAME cN I (J (t_(J a C_` C(,,
CI� . .
LOCATION —ty 1 V\/`,ci'Y�'l i'.r�-
DATE \\. c�S 11 PERMIT � �"}'( 5
S TYPE OF STRUCTURES .. .. r Q ,
FOOTINGS FOUNDATION BACKFILL _ FRA ,09.• r
ROUGH PLUMBING' SEPTIC INSULATION
FINAL ELECTRICAL WOODSTOVE OR FIREPLACE,'.
N/A Imp NO
CHIMNEY HEIGHT/B VENT/HEIGHT V"
PLUMBING VENT I
ROOFING \ A i/
EXTERIOR FINISH \ /
DECK/PORCH/STEPS/RAILINGS/ \Yr/
RELIEF VALVES V! •
FURNACE/HOT WATER 0 ERATING i
INTERIOR TRIM/PRP�ACY 'DOORS
FINISH FLOORS:! \ tr
BATH/KITCHI WATERTIGHT
OTHER FL ORS SWEEPABLE\
OTHER FLOORS CARPETED
STAIR CLEARANCE/RAILINGS J,
SMOKE DETECTORS f "
. BATHROOM FANS V
PLUMBING FIXTURES �/
FOUNDATION INSULATION •
�1/
GARAGE FIRE PROOFING
DOOR CLOSERS
FINAL ELECTRICAL
SITE PLAN/VARIANCE REO.
FINAL SURVEY ':sT PLAN
OK TO ISSUE /0' OR C/C
0 f -,r/'- 45 d is j C941 ;i/e- t//av j45`
,iM t ri j i 6-Z66- -k Fkok , zu(RM1
TOWN OF QUEENSBURY 3PTV\
FIRE MARSHAL
QUEENSBURY, NEW YORK 12804
TELEPHONE (518) 745-4424 .
FIRE MARSHAL INSPECTION REPORT
REQUEST FOR INSPECTION RECEIVED 114/0_015
NAME rV �/� �Z-) &AAA()
LOCATION Ni�.. �"i ' - 1(VIATILialA
DATE \\1.4-Ql PERMIT#
APPROVED
N/A YES NO
EXITS
AISLE WIDTHS /
EXIT SIGNS /
EMERGENCY LIGHTING
Y./
f
FIRE EXTINGUISHERS ff 9
AUTO. EXTINGUISHING SYSTEM
HOOD INSTALLATION /
AUTO. SPRINKLER SyS TEM
ALARM SYSTEM /
•
INTERIOR FINISHES
i
STORAGE:
CLEARANCE TO SPRINKLERS!
CLEARANCE TO HEATING UNITS
%REQUIRED SIGNAGE
CHIMNEY
WOODSTOVE
FIREPLACE-MASONRY
FIREPLACE-FACTORY BUILT
REMARKS: l I OK TO THIS DATE
'`/Z ., -L/4A /2' ( //1114/21-C/
2/015 INS ECTOR
TOWN OF QUEENSBURY
BUILDING & CODE ENFORCEMENT
531 Bay Road
Queensbury WY 12804
518-745-4447
SEPTIC DISPOSAL SYSTEM INSPECTION
Name S% Cke i)�
Location "( 3- r -J
Date
-" 0 s Permi tq5-- L4FS
SOIL TYPE: Sand-Loam-Clay
Res,lts of Percolation Tes -
(if :,plicable Rate-Minu a/Inch .
TYPE SYSTEM
ABSORP'ION FIE.D: 'otal Length
Length • each ench
Depth of ren, 'es
Size of st► e
SEEPAGE T umber-
Size - t. x ft.
Stone size
PIPING: Size Type
Bldg. to Tank
Tank to Dist. Box
Dist. Box to Field ' t
Openings Sealed? Yes No Partial
LOCATION/SEPARATION, .
Foundation to Tank feet
Foundation to Abso ption feet
Separation of Pits _ feet
Conforms as per Plot Pl .n Yes No
LOCATION OF SYSTEM, ON P°`OPERTY:
(circle one)
Front - Rear .- Le t Side - Right Side
Middle Front - Mi.dle Rea
COMMENTS:
e ' C,;(a^k 4 (1,14-k
SYSTEM USE APPROVE' : e75
'NO
Arrived:
Departed:
Building Inspector
•
TOWN OF QUEENSBURY .
BUILDING & CODE ENFORCEMENT
531 Bay Road
Queensbury NY 12804 •
518-745-4447
SEPTIC DISPOSAL SYSTEM INSPECTION
Name ac'/,/46 GS • 2J(j3 •
Location _ kP ski •
Date 1A1516K Permit # � 1165
SOIL TYPE: Sand-Loam-Clay-
Results of Percolation Test-
. (if applicable) Rate-Minute/Inch
TYPE OF SYSTEM:
ABSORPTION FIELD: Total Length
Length of each trench
Depth of trenches
Size of stone
SEEPAGE PITS: Number- .
Size - ft. x / ft.
• Stone size f .
PIPING: � 8ize Type
Bldg. to Tank
- Tank to Dist. Box %
Dist. Box to Fi el d/P,:.
Openings Sealed? No Partial
LOCATION/SEPARATIONS.,
Foundation to Tank A feet
Foundation to Absorp,ti d.n feet
Separation of Pits ' -- f-'
Conforms as per P1 oft Plan Ye No
LOCATION OF SYSTEM,/ON PRO ERTY:
(circle one)
Front - Rear - Left Side - Right Side
Middle Front - Middle Rear
COMMENTS:
@ \7" 0((-1)06 '
S u&W-1- 1�`� — 15 Ut cr. Pi--
. eJ .
SYSTEM USE `�APPROVED: YES NO
Arrived:
Departed:
Building Inspector
plik
TOWN OF QUEENSBURY
BUILDING & CODE ENFORCEMENT
531 Bay Road
Queensbury NY 12804
518-745-4447
SEPTIC DISPOSAL SYSTEM INSPECTION
Name P4tc ,/�GS &e�
.. .
( Location 1or37 aviet , 6T
Date ////c/cS'-- Permit # K-165----
SOIL TYPE: a i-Loam-Clay-
Results of Percolat on Test-
(if applicable) Rat:-Minute/Inc
TYPE OF SYSTEM:
ABSORPTION FIELD: . Tptal Lengt_, ;7- 2-e -
Length of each trenAh j
Depth of trenches
Size of stone Mgr
SEEPAGE,PITS: Num.-
Size ft. ft.
Stake size PIPING: -
i . S.izp jype
Bldg. to Tank )e!9 lid
Tank to Dist. BR ` r),v
Dist. Box to F eld Pit 4+
Openings Sea ed? Yes Partial
LOCATION/S :S ARATI t, S:
Foundatio to Tan : _ __ / feet
Foundation to Absorption (� feet
Separa ,on of Pi s fee
Confo . ,s as per °lot Plan ! Yes o
LOCAT ON OF SYS T M ON PROPERTY: .
(cir le .- .,
Front _ R .- :Left Side - Right Side
Mi�.dle •ront - .Middle Rear
IMMENTS:
0- SuP�mt1" A5 8vit_ PLvj fL44)
(_.. Se-A-L 7 i76- AT Bu iLpi NC,
SYSTEM USE APPROVED: YES , NO
Arrived: f•
Departed: i
Building Inspector .
72-tl, S
TOWN OF QUEENSBURY
BUILDING A CODE ENFORCEMENT
531 Bay Road
Queensbury NY 12804
518-745-4447
SEPTIC DISPOSAL SYSTEM INSPECTION,
Name M?Cq s £ ei
Location ' ONAKWI,J GT
Date /I - Permit # �6 18S
1 .�
SOIL TYPE: Sand-Loam-Clay-
Results of Percolation Test-
(if applicable), Rate-Minute/Inch
TYPE OF SYSTEM:.
ABSORPTION FIELD: Total L ngth
Length of each trench
Depth of trenches ,
Size of stone '.
SEEPAGE PITS: Number/
Size - ft. x ft.
Stone size t
PIPING: ; Size Type
Bldg. to Tank
Tank to Dist. Box<<
Dist. Box to Fiel /Pit
Openings Sealed?,',; Yes No Partial
LOCATION/SEPARATIONS:
Foundation to T nk': feet
Foundation to Af sorption feet
Separation of/its a _ feet
Conforms as per Plot Plan Yes No
LOCATION OF SYSTEM ON PROPERTY:
(circle one)
Front - Rear - Left Side - Right Side
Middle Front - Middle Rear
COMMENTS:
/flei
SYSTEM USE APPROVED: YES C7p
Arrived: 4-0
Departed: Aggs
Building Inspector
/ k.1 .4 '(
,Ji A''''' ''
TOWN OF QUEENSBURY u ; . ?=`�
BUILDING & CODE ENFORCEMENT ='s
531 BAY RD. , \.-
QUEENSBURY N�Yi 12804 ,t .;• ,x"
INSPECTOR'S REPORT: AR L5/DEPAR T: IN���4.
REQUEST FO
IlNNSPECT�ON RECEIVED:,N Id . __ Sr
'Lls/i i,e
NAME /%v i 5 ,'
LOCATIOON a! /4./il'
DATE 0 PERMIT # 675 ' 116J
TYPE OF STRU URE: 5 f
RECHECK APPROVED
N/A YES NO
FOOTINGS/PIERS
MONOLITHIC POUR FORM
REINFORCEMENT IN PLACE
•
THE CONTRACTOR IS RESPONSIBLE FOR
PROVIDING PROTE TI6N FROM FREEZING
FOR 48 HOURS FOLLO ING THE PLACE-
MENT OF THE CONCRE E. -4
MATERIALS FOR THIS URPOSE ON SITEf
FOUNDATION/WALLPOUR /
REINFORCEMENT IN PLA E /
FOUNDATION/DAMPPROOFI G /
BACKFILL APPROVAL /
PLUMBING VENT/VENTS INlPLACE
/
ROUGH PLUMBING ,�{
PLUMBING UNDER SLAB; i
FRAMING: / \
JACK STUDS/HEADERS. -
, BRACING/iBRIDGING
JOIST HANGERS ? -
JACK POSTS/MAIN BEAM w
f ABA,-
-
AIR INFILTRATION BARRIER /C "
j
HEATING ROUGH-IN :
3 --
INSULATION: 1
FOUNDATION WALLS INTERIOR1R-
FOUNDATION WALLS EXTERIOR R- I - -
FLOORS R- -
WALLS R- -
CEILING R-
DUCT WORK OR PIPING IN --
UNHEATED SPACES R-
�r0
TOWN OF QUEENSBURY
BUILDING & CODE ENFORCEMENT " r`
531 BAY RD. , QUEENSBURY NY 12804
INSPECTOR'S REPORT: ARR j 'kEPARIO
REQUEST FOR INSPECTION RECEIVED: in
NAME
LOCATION c
DATE /0 2 Cjj PERMIT # - (if KS
TYPE OF STRUCTURE:
RECHECK APPROVED
N/A YES NO
FOOTINGS/PIERS
MONOLITHIC POUR FORM
REINFORCEMENT IN PLACE
THE CONTRACTOR IS RESPONSIBLE FOR
PROVIDING PROTE TION FROM FREEZING
FOR 48 HOURS FOLLOWING THE PLACE '
MENT OF THE CONCRETE.
MATERIALS FOR THIS PURPOSE ON SINE
FOUNDATION/WALLPOUR /1
REINFORCEMENT IN PLA•
FOUNDATION DAMPPROOFI
BACKFILL APPROVAL
PLUMBING VENT/VENTS IN :•:ACE
ROUGH PLUMBING
PLUMBING UNDER SLA$
FRAMING:
JACK STUDS HEADERS
BRACING/BRIDGING
JOIST/HANGERS
JACK POSTS/MAIN BEAM
/AIR INFILTRATION BARRIERVA
HEATING ROUGH-IN
INSULATION:
FOUNDATION WALLS INTERIOR R-
FOUNDATION WALLS EXTERIOR R-
FLOORS R-
WALLS R-
CEILING R-
DUCT WORK OR PIPING IN
UNHEATED SPACES R-
/a1
feo , 06 (PL�T
Y9— '��v
TOWN OF QUEENSBURY
FIRE MARSHAL
QUEENSBURY, NEW YORK 12804 L
TELEPHONE (518) 745-4424 `
FIRE MARSHAL INSPECTION REPORT
REQUEST FOR INSPECTION RECEIVED //0-1 -- l
NAME ���� ey(I� �
LOCATION -37 � ---
DATE / 0 PERMIT# 9 ✓, j��
APPROVED
N/A YES NO
EXITS
AISLE WIDTHS
EXIT SIGNS
EMERGENCY LIGHTING
FIRE EXTINGUISHERS 1 J
AUTO. EXTINGUISHING SYSTEM /
HOOD INSTALLATION 1 /
AUTO. SPRINKLER SYSTEM
ALARM SYSTEM ;
INTERIOR FINISHES /1
STORAGE: �
CLEARANCE .TO/SPRIN¢KLERS
CLEARANCE TO HEAT UNITS
REQUIRED S G AGE J,
1 f
A to
CHIMNEY'
WOODSTOVE
FF�REPLACE-MASONRY
G4;IREPLACE-FACTORY BUILT
REMARKS: / ('K TO THIS DATE
"0-d % y
/4/'
2/015 'INSPECTOR
`'ryyc
TOWN OF QUEENSBURY ;k'"
BUILDING & CODE ENFORCEMENT `,xa:,
531 BAY RD., QUEENSBURY NY 121804
INSPECTOR'S REPORT: ARR r '!!�<PART� �"INI JI
REQUEST FOR (IINSPECTION RECCCEIVED: JO -cis-
NAME _ l \ bt_ck_z 7 :-Y Qn,
LOCATION -3 7 tl r /4,*
DATE PERMIT N S
I
TYPE OF ST UCT E:
RECHECK AP'ROVED
N/A YES NO
FOOTINGS/PIERS
MONOLITHIC POUR FORM
REINFORCEMENT IN PLACE
THE CONTRACTOR IS RES•ONSIBLE FOR
PROVIDING PROTE TION F•OM FREEZING
FOR 48 HOURS FOLLOWING (HE PLACE-
MENT OF THE CONCRETE.
MATERIALS FOR THIS PURPOS: ON SIT ,
FOUNDATION/WALLPOUR
REINFORCEMENT IN PLACE
FOUNDATION/DAMPPROOFING
BACKFILL APPROVAL
PLUMBING VENT/VENTS IN PLACE
ROUGH PLUMBING
PLUMBING UNDER SLAB
RAMING:
JACK STUDS/HEADERS
BRACING/BRIDGING
JOIST HANGERS
JACK POSTS/MAIN BE
AIR INFILTRATION BARRIER
HEATING ROUGH-IN
INSULATION:
FOUNDATION WALLS INTERIO R- _
FOUNDATION WALLS EXTERIO R-
FLOORS R-
WALLS R- -
CEILING R_
DUCT WORK OR PIPING IN
UNHEATED SPACES -
•
efbI6Pk ISLOG.('aVI) ii<
A4I4.0,dK 'VAM.0) \c2
e77—
TRdG �� — FULL- Be4 (t gcl-J6V-1,A1
ti0S
//UJ j:ALL zz- Melo ?ors
VV.() 4
a-I-A- , o
Y i.
TOWN OF QUEENSBURY *' ,,
BUILDING & CODE ENFORCEMENT t:.. ."-rs
531 BAY RD., QUEENSBURY NY 12804 ..,,y..;g
INSPECTOR'S REPORT: ARV A•-,/V DEPART.` `, INT
REQUEST FOR°! INSPECTION RECEIVED: �L
NAME _ M\i;C \_rI /, CSC&
LOCATION 3 c j)_ _ "1J
DATE PERMIT H . --L 5
I
TYPE OF STRUC'URE:
RECHECK APPROVED
r../A YES NO
FOOTINGS/PIERS
MONOLITHIC POUR F0•
REINFORCEMENT IN PL CE
THE CONTRACTOR IS RE:PONSIBLE FO•
PROVIDING PROTE TION ROM FREEZI 'G
FOR 48 HOURS FOLLOWINe THE PLACE,
MENT OF THE CONCRETE.
MATERIALS FOR THIS PURPaSE ON S,TE
FOUNDATION/WALLPOUR
REINFORCEMENT IN PLACE
FOUNDATION/DAMPPROOFING
BACKFILL APPROVAL
7
P JJMBING VENT/VENTS IN PLAC '' /
ROUGH PLUMBING �/
PLUMBING UNDER SLAB
FRAMING: _
JACK STUDS/HEADER.
BRACING/BRIDGING
JOIST HANGERS
JACK POSTS/MAIN :EAM
AIR INFILTRATION BARRIER
HEATING ROUGH-IN
INSULATION:
FOUNDATION WALLS INT RIOR R-
FOUNDATION WALLS EXT RIOR R-
FLOORS R-
WALLS R-
---f
CEILING R-
DUCT WORK OR PIPING IN
UNHEATED SPACES R-
/la6; - /041/... it'44-r= L.u'ticb A . '/ (OK'
Aff;71 3 0 Ry\
TOWN OF QUEENSBURY .4:; '
BUILDING & CODE ENFORCEMENT
531 BAY RD., QUEENSBURY NY 12804 i rryt ► 1'''
INSPECTOR'S REPORT: ARR�- ' EPART 5�IN1..j
REQUEST FOR INSPA TION RECEIVE 10 —/,? `9 1
NAME \CY\(ISQ0 (41r(1
LOCATION y G�.ti ���wL
!DATE 0—/ T -95 PERMIT # 9 5"'y.X
TYPE OF STRUCTU P0 V 5
RECHECK d
_ APPROVED
N/A YES NO
FOOTINGS/PIERS
MONOLITHIC POUR FORM
REINFORCEMENT II++II PLACE
THE CONTRACTOR RESPONSIBLE FOR
PROVIDING PROVE ION FROM FREE ING
FOR 48 HOURS FOL OWING THE P ,,CE-
MENT OF THE CONCR TE.
MATERIALS FOR THIS PURPOSEf+N SITE
FOUNDATION/WALLPOUA�
REINFORCEMENT IN PLACE
FOUNDATION/DAMPPROOF> r
BACKFILL APPROVAL A
PLUMBING VENT/VENT'" I ', PLACE
ROUGH PLUMBING
PLUMBING UNDE• SLAB
FRAMING:
JArK STUDS/HEA.ERS 1-
B' CING/BRIDGING
,. OIF?T HANGERS
/JACK POSTS MA BEAM
AIR INFILTRATION BARR ER
HEATING ROUGH-IN
__SULATION:
FOUNDATION WALLS NTERIOR R- _
FOUNDATION WALLS EXTERIOR R-
FLOORS R-
WALLS /Y.
CEILING R-13e/
DUCT WORK OR PIPING IN
UNHEATED SPACES R-
Th
n C66/6e-----
TOWN OF QUEENSBURY nA
BUILDING & CODE ENFORCEMENT : „ >'!
531 BAY RD., QUEENSBURY NY 12804 '.,$ Y,x .
INSPECTOR'S REPORT: AR� '/ DEPART Z15 JIN„y
REQUEST FOR INSPECTION RECE VED:
NAME IlVC H 6-62- 1 //'-�
L
1
LOCATION l 3 4 c,- IAV"4Ay c j
DATE 12/b ) PERMIT N 971-:" 5
TYPE OF STRUCTURE: l l0
RECHECK
APPROVED
N/A YES NO
FOOTINGS/PIERS
MONOLITHIC POUR FORM
•
REINFORCEMENT IN PLACE
THE CONTRACTOR IS RESPONSIBLE FOR
PROVIDING PROTE TION FROM FREEZING
FOR 48 HOURS FOLLOWING THE PLACE—
MENT OF THE CONCRETE.
MATERIALS FOR THIS PURPOSE ON SITE
FOUNDATION/WALLPOUR
- REINFORCEMENT IN PLACEii .
1
FOUNDATION DAMPPROOFING ,
BACKFILL APPROVAL
PLUMBING VENT/VENTS IN P ACE
ROUGH PLUMBING
P UMBING UN R(�SjL�AB 1
t RAMING: riilf�-i 1if l—' I -
JACK STUDS/HEADERS r 1
BRACING/BRIDGING'' /
JOIST.4HANGERS ) - �/
JACK'POSTS/MAINABEAM w
AIR INFILTRATION BARRIER
HEATING ROUGH-IN
INSULATION:
FOUNDATION WALLS INTERIOR R-
FOUNDATION WALLS EXTERIOR R-
FLOORS R- -
WALLS R- -
CEILING R-
DUCT WORK OR PIPING IN
UNHEATED SPACES R- •
f N:t 11,\ (A) LA; ---
0 [(. t ova,
• C7 M
y'n�
TOWN OF QUEENSBURY r
BUILDING & CODE ENFORCEMENT d
531 BAY' RD., QUEENSBURY NY 12804 r,, ;',s.,,W
INSPECTOR'S REPORT: AR ®DEPART 7IC,INTs
REQUEST FOR INSPECTION REC IVED: / 01100 5
NAME \ c \ (i Q 0 U f'l.V\.4/
LOCATION CO3 e. _ .,,, ,-_ C j1
DATE / 1 v C PERMIT # _ L
TYPE OF STRU TURE:
RECHECK _ APPROVED
N/A YES NO
FOOTINGS/PIERS f
MONOLITHIC POUR F RM
REINFORCEMENT IN P ACE / , _ _
THE CONTRACTOR IS SPONSI�BLE FOR
PROVIDING PROTE TIO FRO FREEZING
FOR 48 HOURS FOLLOW NG M E PLACE-
MENT OF THE CONCRET
MATERIALS FOR THIS P "POSE ON SITE
FOUNDATION/WALLPOUR
REINFORCEMENT IN P•
FOUNDATION/DAMPP+OOFINi,
BACKFILL APPROV'L
PLUMBING VENT ENTS IN ',LACE
ROUGH PLUMBING
PLUMBING CIDER SLAB
FRAMING:
JACK STUDSLHEADER.
BRACING BRIDGING -.
JOIST HANGERS
JACK POSTS/MAIN B AM
AIR INFILTRATION BARRIER
ATING ROUGH-IN
-—17/
INSULATION:
FOUNDATION WALLS INTERIOR R-
FOUNDATION WALLS EXTERIOR R-
FLOORS R- -- .
WALLS R-
CEILING R-
DUCT WORK OR PIPING IN
UNHEATED SPACES R- .
•
Aiic-f-- _ K.,,"/Inci
e ALL 1--0.--- (e.. te6c(16crC.. , ..
0.,
TOWN OF QUEENSBURY
BUILDING & CODE ENFORCEMENT et,
531 BAY RD., QUEENSBURY NY 12804 ',,:t:
� wryi tAA
INSPECTOR'S REPORT: AR !�J DEPAR'FD INT,
AL
REQUEST FOR INSPECTION RECEIVED: /0 /3 j S
NAME C e( ! n c C�c� \
LOCATION cTnik l\ \_01 4
DATE /0 J( /+S P RMIT #
TYPE OF STRUCTURE: < _�
RECHECK I APPROVED
N/A YES NO
i
FOOTINGS/PIERS _- /
MONOLITHIC POU• FORM J
REINFORCEMENT IN PLACE
t
THE CONTRACTOR IS RESPQQ¢NSIBLE FOR
PROVIDING PROTa TION FttOM FREEZING
FOR 48 HOURS FO LOWINe THE PLACE—
MENT OF THE CONS ETE.
MATERIALS FOR TH•S PU'POSE ON SITE
FOUNDATION/WALLPO R
REINFORCEMENT IN P64CE
FOUNDATION/DAMPPROO JNG
-
DACKFILL APPROVAL \
PLUMBING VENT VEN S IN PLACE
i
PLUMBING UNDER S AB S
1 :- - --
,
ING: l BACK STUDS/HEADERS ` �. -
BRACING/BRIDGING
JOIST HANGERS
JACK POSTS/MAIN BEAM
AIR INFILTRATION BARRIER F
HEATING ROUGH-IN
INSULATION:
FOUNDATION WALLS INTERIOR R-
FOUNDATION WALLS EXTERIOR R- I -
FLOORS R- I - ---
WALLS R- -
CEILING R-
DUCT WORK OR PIPING IN '-
UNHEATED SPACES R-
Cv0� fib_ i/LvSS A--1(4'4(1UC., 4.)7Wtel{14).
11 j-4LC .1-"'lP UtvtA&R, ( t QoOkJL Lo,14-zL
C2,-4 r-4-000
1 A)Srpcc./... FR/AA&I k'& at i (4 A
0/01(16:-R ALA Ci4ii L41J 1A)6 S
4'L) Ibf2 !AMA/ i &41 (3s 5
F.r f•„
TOWN OF QUEENSBURY !';-y. '"
BUILDING & CODE ENFORCEMENT s#`
531 BAY RD., QUEENSBURY NY 12804 r`''t`.;y' ;;qrr„,
r S/*...
INSPECTOR'S REPORT: ARR/' " DEPARTl'fr INT-1 ec-
REQUEST FOR INSPECTION REC.IVED:
NAME _ /44744/416eS Cop
LOCATION 107-57 CXMIPItAti 07
DATE Ik14--- PERMIT Q �' �-
TYPE OF STRUCTURE: 'W
RECHECK APPROVED
N/A YES NO
FOOTINGS/PIERS ,
MONOLITHIC POUR FORM / .
REINFORCEMENT IN PLACE I
THE CONTRACTOR IS RESPONSIBLE FOR
PROVIDING PROTE TIO FROM FRE ZING
FOR 48 HOURS FOLLOWI G THE P ACE-
MENT OF THE CONCRETE11i11it
MATERIALS FOR THIS PURPOSE O SITE
FOUNDATION WALLPOUR
REINFORCEMENT IN PLACE
FOUNDATION/DAMPPROOFING' _
6AC ILL APPROVAL '
UMBING VENT/VENTS IN Pt r
ROUGfi PLUMBING
PLUMBING UNDER SLAB
FRAMING:
JACK STUDS/HEADER` \
BRACING/BRIDGING
JOIST HANGERS
JACK POSTS/MAIN SEAM \
AIR INFILTRATION BARRIER
l
HEATING ROUGH-IN / \`
INSULATION: `
FOUNDATION WALLS INTERIOR R- ) ,
FOUNDATION WALLS EXTERIOR R-
FLOORS R-,/ ---
WALLS R- -
CEILING R-
DUCT WORK OR PIPING IN --
UNHEATED SPACES R-
.3 c---,4)
r"A TOWN OF QUEENSBURY 0. k
BUILDING & CODE ENFORCEMENT •
531 BAY RD., QUEENSBURY NY 12804 "ttti
INSPECTOR'S REPORT: ARR/, Z EPART,: J4 NTv R-
/
REQUEST FOR INSPECTION RECEIVED: -/ (-1 ='i 5
� J�
NAME � C'1� C G A
LOCATION 3 1 evv\Cen,�
DATE � ---I S ttt .9 5- PE I T # 5����''_000 �l�rr! JJJJC
TYPE OF STRUCTURE:
RECHECK APPROVED
N/A f YES NO
•
FOOTINGS/PIERS
MONOLITHIC POUR FORM
REINFORCEMENT IN PLAC.
THE CONTRACTOR IS RESPO. SIBLE FOR
PROVIDING PROTE TION FRIM FREEZING
FOR 48 HOURS FOLLOWING IE PLACE-
MENT OF THE CONCRETE.
MATERIALS FOR THIS PURPOSE ON SITE
FOUNDATION/WALLPOUR
REINFORCEMENT IN PLACE
FOUNDATION/DAMPPROOFING
1,,BACKFILL APPROVAL .. V
PLUMBING VENT/VENTS IN PIllr
ROUGH PLUMBING l
PLUMBING UNDER SLAB
FRAMING:
JACK STUDS/HE I •S
BRACING/BRIDG
JOIST HANGERS -
JACK POSTS MA .EAM
AIR INFILTRATION BARR 'R
HEATING ROUGH-IN
INSULATION:
FOUNDATION WALLS INTERIOR R-
FOUNDATION WALLS EXTERIOR R- --
FLOORS R-
WALLS R_
CEILING R-
DUCT WORK OR PIPING IN
UNHEATED SPACES R- •
P /2J
•
TOWN OF QUEENSBURY 3 ;j'.
BUILDING & CODE ENFORCEMENT •
531 BAY RD., QUEENSBURY NY 12804 oetjcikio-t..,
INSPECTOR'S REPORT: ARR4 35DEPART _ INT
REQUEST FOR INSPECTION RECEIVED:
NAME /(111? 46- s
46-2
LOCATION
DATE f PERMI #
TYPE OF S RUCTURE:
RECHECK _ APPROVED
N/A YE. NO
OOTINGS/PIERS
MONOLITHIC POUR FORM
REINFORCEMENT IN PLACE
THE CONTRACTOR IS RESPONSI:LE FOR
PROVIDING PROTE TION FROM F•EEZING
FOR 48 HOURS FOLLOWING THE :•LACE-
MENT OF THE CONCRETE.
MATERIALS FOR THIS PURPOSE 0 SITE
FOUNDATION/WALLPOUR
REINFORCEMENT IN PLACE
FOUNDATION/DAMPPROOFING ■
BACKFILL APPROVAL .
PLUMBING VENT/VENTS IN PLACE
ROUGH PLUMBING 1
PLUMBING UNDER SLAB
FRAMING:
11111
JACK STUDS/HEADERS
BRACING/BRIDGING
JOIGT HANGERS •
JACK POSTS MAIN BEAM
AIR INFILTRATION BARRIER
HEATING ROUGH-IN
INSULATION:
FOUNDATION WALLS INTERIO R-
FOUNDATION WALLS EXTERIORt R-
FLOORS f R-
WALLS I R-
CEILING R-
DUCT WORK OR PIPING IN
UNHEATED SPACES R_ .
•
I D" .I\ L01
i
f 7 i
st \. , � • , ..
, ,
..,....... .
ti...,,,„_ . , ��
_.....
• : ,
:,47 ,
.,. 0.,.,
\ .
_,„,
...„._. „,_ ..4., , ,--J.:4
`t'!Ihave seen or Oft .,r. -.lam i or - Y �`� -'
objects such as ‘ �+�
own on this document "k MN� `�` • ;;
ovally m the�
fi ! f ..
., „, ••;;;/`-'-'. ''' '''"'.....,,,,/
Ii\si\-,..0 ,_gOrr 47. f+...,,.4:‘..,_>_:, ,z,▪ -- .
• SIGNATU V•' _ n ,eV J
DATE r r -<: .- / ,
- \ 0.‘..1: ,,,s_ ..z: . , , ,,,,L9 _,. • ,,
" /ram
•
, . -,-... 7/ .
•
•
I} , . „-_. /.-
`, 1
7:07:1 43 AdfiliSll:.a",:itille
'TOWN O •QUE NSF3 ",i's' PLOT PLAN
� �� LOT 37 DSSPOI
A(f& , TOWN OF QUEENSBURY COUNTY OF WARREN
j r ,;;, . 7995 ���u s L r SCALE 1.=30' DATE: JULY 25, 1995
'i),4,0.„ ', s° 1 1 .E) �u.(1 -�r6-e►�ttr\1 �kbe 4',A VanThisem k Staves
! - _ ( ,,,,,,(,- i CI A C/L"ZlU 2.�\� LAND. SURVEYORS,GLENS FALLS,NEW PORK
u°00,5,
N.Y, STATE LIC. NO. 35617
1 '
1
.
.
•
H.O.A. GREEN SPACE
$ E:-)
'� LOT 361 ., _
k'`°
•
4..S'' \.. . " ;L.?'.; \? ,7)1.5;'-:;/ . . '
LOT ft) ' 90 AO', % ' �1
15,9:6 s• ft 'ea' `:9
,1
T 3a
LE 1
x✓`\ `
k ,\ 33.40'
IA \ e ''!. , 1° .
cp. ..1. S N.
_ . �r )✓ v
4�.4O
( \ . i.
tip`
\ /by
z�°° be d .
35.00' �
•
4'i
PLOT PLAN OF
LOT 37 HUDS01
TOWN OF QUEENSBURY ' COUNTY
. SCALE: 1'=30' DATE'
• VanDusen & S
1 AAIT t`I IG\/ vnnc^ ri rMc� "-All