Loading...
INSPECTION WORKSHEET 04022024 INSPECTION WORKSHEET Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number: RC-0694-2023 Case Module: Permit Inspection Date: April 02, 2024 Inspection Status: Passed Inspector: Charles Dyer Inspection Type: Residential Final Job Address: 377 CLEVERDALE RD , Parcel Number: Contact Type Company Name Name Owner N/A Christopher Boucher Applicant N/A James Purdy Checklist Item Status Building Inspector notes for basement renovation with egress window PASS 4 inch min building number address visible from road PASS Chimney height, B vent, direct vent location N/O Chimney rain cap installed N/O Fresh air intake N/O Fresh air supply 3 feet from grade N/O 3 inch plumbing vent through roof, minimum 18 inches N/O Outside spigots have air gap N/O Roof complete N/O Exterior finish complete PASS Platform at all exterior doors N/O Handrail required with 4 or more risers PASS Guards at stairs, decks and patios 30 inches or more above grade PASS Guard at stairwell at 34 inches or more PASS Window guards req at less than 2' above floor and 6' above grade N/O Guard at deck and porches 36" or more in height N/O Handrail termination at newell post or wall PASS Interior and exterior handrails 34" to 38" high PASS Wood deck 2 feet or more from grade diagonal bracing required N/O 4 or more Deck Joist Ledger Connections starting 24" from each end N/O Deck ledgers to be bolted per code N/O Grade away from foundation sloping 6 inches in the first 10 feet N/O 6 inch clearance to sill plate from grade N/O Gas meter and or regulator shut off 12 inches min above grade N/O HVAC vent terminal 10 feet from lot line and openings N/O Dryer duct max length 35 feet or per manufacturer's instructions N/O Interior privacy doors and trim required PASS Exterior main entrance door min 36" wide N/O Bathroom and Kitchen floors must be watertight N/O Low flow toilet 1.3 gallon per flushing cycle PASS Smoke detectors are min of 3 feet horizontally from opening of bathroom PASS Smoke Detectors are required on every level and in every bedroom PASS Smoke Detectors are required outside every bedroom area PASS Smoke Detectors have battery back up PASS Smoke detectors are interconnected PASS Carbon monoxide detectors are within 10 ft of all sleeping areas PASS Carbon monoxide detectors are required on all levels with gas appliances (i.e. furnace) PASS Foam in basement and attics covered with thermal barrier N/O Bathroom fans required, if no window PASS All plumbing fixtures complete PASS Backflow preventors where required N/O Foundation insulation to basement floor PASS Energy sticker on elec. panel, R values and heating systems N/O All Hot Water Systems R 3 on 3/4 inches or larger piping PASS Duct work sealed properly N/O Intake openings for HVAC N/O Range Hood 400 or more cfm make up air required N/O Emergency egress window below grade 44 inches max from sill height from basement floor PASS Furnace shut off within 30 ft. or within line of site N/O Oil furnace shut off at entrance to furnace area PASS Propane tank proper setback from property line or structure N/O Furnace and hot water heater operating PASS Low water shut off required for boiler PASS Pressure relief valve, heat trap, water temp 110 degrees or less PASS Pressure relief valve down spout within 6 inches of floor PASS Hot water drain pan to indirect waste N/O Encl. stairs sheetrock underside minimum ½ inch gypsum N/O Basement stairs closed rise greater than 4 inches PASS Basement wall insulation R- value verified PASS Basement egress: 5 s.f. window w/sill or Bilco door PASS Jack posts in basement lagged at top and bottom N/O Fireblocking at fl joist 80 s.f. or less N/O Fin elect; energy saving light bulbs 90 percent PASS CSST/other piping in conduit if buried,if required N/O Arc fault breaker habitable spaces PASS Flex gas pipe bonding N/O As built septic system PASS Electronic as builts N/O Ok to issue certificate of occupancy PASS Charles Dyer Code Enforcement Officer