Signed Inspection Report (04-25-2024) IIII IIII IIII IIIIIII IIIIIIIIIII IIIIIIIIIIIII IIIIIII 111111111114U1111lIIIIII 111 IIII III IIIII IIII IIIIIII�IIIIIIII�`111 IIIIIII I111 III IIIIIIIIIIIII Illlllllllllllllllllllllllll I I I I Il 111 II III I I I I
IIUI I III IIII�II�I I I I�11
`I
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road -(518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: POOL-0219-2023 Case Module: Permit
Inspection Date: April 25, 2024 Inspection Status: Passed
Inspector: Charles Dyer Inspection Type: Pool
Job Address: 105 FARR LN Parcel Number:
Contact Type Company Name Name
Contractor Adirondack Pools & Spas
N/A MICHAEL NELSON
Granted Permission N/A MICHAEL NELSON
Primary Owner N/A MICHAEL NELSON
Checklist Item Status
Permit card visible from road PASS
Building Inspector notes PASS
Windows less than 48 inches above the
floor are required to have 4 inch max
window control device PASS
Pool enclosures around pool or yard: 4
feet above grade PASS
Pool enclosures around pool or yard: 2
inch maximum to grade from underside of
fence PASS
Pool enclosures around pool or yard: 4
inch maximum clearance in fence pickets PASS
Pool enclosures around pool or yard: 1
3/4inch maximum spacing for wire fence PASS
Pool enclosures around pool or yard: Self
closing device or alarms (30 sec alarm
time) PASS
Pool enclosures around pool or yard:
Gate is less than 56 inches to latch PASS
Pool enclosures around pool or yard:
Gate opens outward and is self closing PASS
Pool enclosures around pool or yard:
Padlock provided on all gates or ladder PASS
Vehicle access gate is closed and locked PASS
II doors are alarmed or self closing for
indoor pools PASS
Pool surface motion alarm PASS
Timer on pool pump; plug in timer is not
allowed PASS
Suction outlet must be protected against
user entrapment PASS
Bottom pool drain vacuum relief system is
required PASS
Final electrical PASS
Ok to issued certificate of compliance PASS
Charles Dyer
Code Enforcement Officer