Loading...
1.2 1.2 WASTEWATER—SEWER\SETPH.VAR\Celeste and Valentine-Holding Tank&Capacity-6-3-13 RESOLUTION SETTING PUBLIC HEARING ON SEWAGE DISPOSAL VARIANCE APPLICATION OF JOHN CELESTE AND THOMAS VALENTINE RESOLUTION NO.: , 2013 INTRODUCED BY: WHO MOVED ITS ADOPTION SECONDED BY: WHEREAS, the Queensbury Town Board serves as the Town's Local Board of Health and is authorized by Town Code Chapter 136 to issues variances from the Town's On-Site Sewage Disposal Ordinance, and WHEREAS, John Celeste and Thomas Valentine have applied to the Local Board of Health for variances from Chapter 136, §136-11, which requires applicants to obtain a variance for holding tanks and the applicants have requested variances to allow a holding tank in lieu of a standard septic system/absorption field and to allow a 2,500 gallon capacity holding tank in lieu of the required 4,000 gallon capacity holding tank on property located at 83 Pilot Knob Road in the Town of Queensbury, NOW,THEREFORE,BE IT RESOLVED, that the Town of Queensbury Local Board of Health will hold a public hearing on June 17th, 2013 at 7:00 p.m. at the Queensbury Activities Center, 742 Bay Road, Queensbury, to consider John Celeste and Thomas Valentine's sewage disposal variance application concerning property located at 83 Pilot Knob Road in the Town of Queensbury and bearing Tax Map No.: 227.18-1-12 and at that time all interested persons will be heard, and BE IT FURTHER, RESOLVED, that the Local Board of Health authorizes and directs the Queensbury Town Clerk to publish the Notice of Public Hearing presented at this meeting and send a copy of the Notice to neighbors located within 500 feet of the property as required by law. Duly adopted this 3rd day of June,2013,by the following vote: AYES NOES ABSENT: General Notes r� kawnvme� %Gy,�N oF' G'tl6rs':9u.Py, GGOE- �EG7?G.r/ /36-!/• so•s e ..o. ° e. e a; 7. See NYSDOH's"Appendix 75-A,Wastewater w,•aoakx...es ux ' �'�� o Treatment Standards-Individual Household Systems" §136-11.Holding tanks.[Added 7-11-19891 &"Individual Residential Wastewater Treatment A Holding tanks are prohibited unless a variance is granted for a huldirg tank by the Laval Board If Health pursuarrt to the ssAwncssu a: ' awo O ° ou2ar Systems-Design Handbook"for additional design variance previsions at§§136-18 to 13&20 or this chapter.[Amended 5-5-i997 by L.L No.4-29971 r• • s� +> ;t _- eoor .p e y g 9 xvarr wur _ _ _ e. In the event me Local Board of Health grants a vadance authorizing use of a hcdding tank,the design and installation of the ..er > �- uoum.em. amsr ,vp and installation requirements. ] - holding tank and alarm system shall comply with the following specifications: [Amended 5S-i997 by L.L Nn.x1997] suskeoawrr .. f — _ _ — 1° Information on this sheet is for septic system design cwuwnrnn g¢ (1) The holding tank shall be a watertight precast concrete septic tank,without ou9ers.with a watettight.sealaM matenai ii f _ for joints below the maximum water level.The tank shall also be equipped with a two-phase aiaan.system.Refer to t' �, - purposes only. Figures l and 3 for the details and specifications required.etlakrs use.Figures 2.uw 7 se o-wea at me e.a Tt ipi, lade. °, L.�sreune ° , / Construction shall be as shown on this drawing and in a usresusmmsrew� .move-ry 9 C2) The holding tank capacity r ri be equal to at least twice the volume of waste generated between anticipated removal . °r°aeT%'•'•^'^ r dads.The-folloaring table gives the minimum size of holding tank required and is basso on Saivism days between accordance with all NYSDOH and system anticipated removal e' m fi =Z="s— HOLDING & SEPTIC TANK DETAIL manufacturers requirements. g!g Required Minimum Holding Tank Capacities °�°°"''D" '°'^°°' ^'$°' All sketches are N,T S.and dimensions only should be Molding Tank Capacity Required secrwevisw - •'w"'O"aCOV Number of Bedrooms (gallons) weto<.o•uo rawnr`°"rn`wio used i 1 2,000 a:.misuv`"i.renru<oaes mrwx. 2 3,.000 w-ukmmern..� 3 35M 0 Min. 50' from �° —�e 2,500 gal. provided f Septic/Holding t 5 4,500 w o Tanks to all wells. (3) The holding tank may be subject to several Rotation forces in areas of high groundwater.Thus,high groundwater applicaranon,asral.Who farin Appendix F,r contrmrr.aepenawalcelation a by recitescnawe.iis required with each N 6 eoomfl n a submittal.ng m a huge one rewater conditions exist,calculations by a registered engineer addressing tank o n flaaWtion and mitigating measures are required. y ' w w (4J Holding tanks shag be located above the one-hundred-year flood laves. i (5) Horizontal separation distances from wastewater sources as provided for in Appendix A,Table 1,must be met.e,,W SPACES F C Cottage with no Nam,n sixA r abie 1.m aoaxiatIS,,ammateanswerTheseparationdistancerequiredforholdingiankssnailbethe / same as required for septic tank PARKING 2 m crawl space or (6) Holding tanks to be located under driveways,roads,parking areas or areas subject to heavy loading shall be VEHICLES '- - basement tan r designed to withstand H-20 highway loads Certification of load capacity shall be supplied by the tank manufacturer. V 8s (7) The holding tank shall fie spo accessible l s for s pumping vehicle.Evidence of agreement with a licensed professional hauler for pump out and disposal is necessary poor to approval of installation. 2 i g C t (S) The holding tank shall be removed or filled with an irrert material it abandoned or when public sewers are instailad.. / �� � # �{/ 11 r kkkG r (9) The storm.system sequence of operations is as follows:When the level of the holding tank reaches 50%of the usable d 5. level in the tank,the yelkrw fight will.indicate"Tank High Level."When the level of the holding tank reaches 100%of emove a a n on I ¢3 Ex. 1 OOO gal. the usable lave]in the tank,the buzzer will sound,the red light will flash to indicate'Tank Shutoff Level,and the o soienord vatve in the main water I(ne will energize and close to prevent any more water from entering the residence, ex. d-box & laterals Septic ' a The pushbutton will be used to silence the buzzer.The system wit reset after the hotdirg tank is pumped down to I ? Tank Y r f r - below the actuation level of the level switches- (shown dashed). I; z T a' d3` Fk "> a tt j F H (10J Float switches shalt be direct acting.nal and east suspended with builev weight which actuates when the longitudinal efar s axis h the float a horizontal dal alternating when the liquid duvet falls one inch mini the actuation level. __. The float switch shall operate at 120 volts ahemating current with a piloE duty of 4.5 amperes minimum.The contact ' . �r1 e shall be normally open,i.e.,it shall close when the Boat rises above the actuation level.The float shall be chemical- ' ' resistant polypropylene calling with a finny banded electrkxl cable.protruding.One end of the cable shall be permanently connected to the enclosed mercury switch,and the entire assembly encapsulated to form a completely watertight and impact-resistant unit,Gould Type A2-2 or equivalent- The v ) (t t) float.switch wiring shall be terminated in a NEMA 4X junction box mounted inside the holding tank.All wiring from ��) 5OO $ l� OOO gal. 9 §_ the float snitch junction box to the level alarm system panel shall be installed underground in accordance with the a�uoo m Re V. U2fE? �OSC(I(]tlOn F latest edition of the National Electric Code and all state and local wtles.Wiring shah be 3#12AWG,Type THW or recast concrete septic I r, THWN,conductors in a one half-inch PVC condduii.One level switch shall be actuated when the tank is at 50%of the precast §, usable capacity to indicate a high level.The second level switch shah be actuated when the tank is at 101 of- re '.; rm r holding tanks w/audible & "� SPACES FOR usable capacity to indicate a snot off level Iv' .,� �� - (12) The control relays shall be general purpose,120 wits alternating current with contacts rated For five amperes visual alarm per Town of m y e `,`` / PARKING 2 continuous.The number and type of contacts snail be as stiwvn,Square"D"8501,Type RS-14,or equivalent-A ' QUeenSbury Specs° ($ee `I_o , VEHICLES Description of Proposed Installation: , relay socket to match the control relay furnished shah be.provided- (13) The alarm lights shall be 120 volts ahemaii es to left). Piping "o" �, g rtg current pilot signs with a domed plastic tens.The High Levi Lel" C light lens shaft be yellow,Square"O"KP1Y9 Type K or equivalent.The'Tank Shutoff Levey'light shall be supplied Approx. location of between tanks to be 4" PVC Holding Tank Septic System ; with a flasher and a red lens,Square"D'KFF1R9 Type Kor equivalent crawl space in SW a I Design {{{ (14) The shall be l?0 volts alternating current,heavy duty,adjustable volume Edwards Adaptabuzzer,Type 340A- SCH 40 pipe, tight joints, corner of cottage ` _ NS or equivalent. o (15) Anormai open,120 Was.alternating P P P min. 2% slope. a � ( normally ngcuypeK onqumalent. pushbutton provided. usnbuttonshall CLIENT: Jack Celeste & TOM Va9entins' have a full guard_Square"'D"KRi UH5 Type K or equivalent. 9 a3 F (16) The relays and.relay sockets shelf be mounted in a general purpose NEMA 1 enclosure.The alarm lights,buzzer and SITE LOCATION: 83 PILOT KNOB ROAD f+ - the buzzer Silence ter .pushWttort shah ct mounted on the front enclosure.ill devices,All necessary materials shall be `g 1 QUEENSBURY, NY provided,i.e.,terminal blocks,connectors,etc.;to mount and connect all devrcas.This enclosure shall be provided rt C wkhanameplatewith the following provided "Holding Tank Level Alarm System."cultic]shall etl nameplates, ,{5®r $ t® Lake George 12804 W through to black win,shall be provided over each device.The nameplate description shall.be as indicated on the schematic.All wiring in the holding tank level alarm system contrci panel shall be installed in a neat and - COUNTY O F: WARREN workmanlike manner.A copy of the schematic and sequence of operation shall remain with control panel.The - ---- enclosureshalt be mounted in a suitable location in the residence. A (17) The solenoid valve shelf be a normally open(energize-to-close)valve,120 volts simmering current and shall be TOWN OF: QUEENSBURY installed in the residence incoming main water fine.The size of the valve orifice shall wrrespond with the pipe diameter of the watedine.Wiring to the solenoid shall be sized in accordance with the latest edition of the National Electric Code. HOLDING TANK LAYOUT PLAN — (18) All holding tanks must be installed below finished grade of the site within a fifty-foot radius of the instadefion.This Scale 1" - 40' SARATOGA SEPTIC SYSTEMS section is intended to prevent the occurrence or mounding in the area of the tank,[Amended 7-8-1998 by LL No.4- 50 Timbira Drive Gansevood,NY 12831 1998] a Other applicablepmvisions contained in this Part 1 shelf apply in addition to the above. SHEET 1 OF 1 DATE: 5/25/2013 MAP REFERENCES 1 MAP OF A SURVEY MADE FOR 2 ALTER 8 DOROTHY BARTHEL 2 O BY'JOHN B. VAN pUSEN ¢ t= DATED:APRIL 15, 1976 U a W U 2 2 Q MAP OF A SURVEY OF TWO PARCELS > OF LAND IN THE TOWN OF QUEENSBURY COIL WARREN COUNTY, NY LOCATED ON LL THE EASTERLY SHORE OF �O VAN WORMERS BAY, LAKE GEORGE MADE FOR Liz JOHN AND ANNA BARTHEL 1 BY.'JOHN B. VAN DUSEN a ' } _, Oz � ?E QATEQ:JULY 3, 1954 t3 z: LAST REVISED:JULY 29, 1954 ( _' I I a -- LANDS N/F OF GURM g 897/43 a t tt± 0 tM 4 x IPF N ) °a v N84°10 5 E 165.45 S86 059'00"E 4 w N49 047'00"E ' '' 293.57 w ✓' `�+ IPF " ---"'--'_-- 5.85 - "--- RIGHT OF WAY _— ----___•, m ,�q S87°16'00"E CRUSHED STONE rt —_ `�^ \ �— ww RxyrReNCe w. i, _ IRF b N73°33'005E v 7.3 '-- \ Area 449 27.2 CR-SnED5iONEDWV i_ \ �4j O� �0 y� ry ro /� �/ \ 30302. 11 sq. ft. ai H r 3.39 0 _ 0. 70 Acres — ------ CRUSHED LANDS NiF OF CAg TCNH P� CORONA ,�� _, ceu EN1Ky (" O ftY �•,. ,"� 0e41 N73 001 '00"E °5 D2 DECK _J CONCRETE DECK BUILDING 4 14. 18 33 BUILDING q 1 SAD i PATIO I z 283.09 a ,y 2 BUILDING 8°O p0, 3' p I 2.2' I ° "' S84 21 '30"W , W . o N86°10'00"E 15.06 / vUi ,I, ��'G C�+eK BUILDING CORNER /�� •„ C3A.C. 3.T-y / �OV9I LINE 0.3' OVER 11NC 0 8' RiE 119 . TMK5 62 BUILDING # , ;PT 206. p S83°30 LANDS�O"W ! DOCKS cva m _ ,s7.s-� DS NIF L OF d '" � -"` , r -v � LANDS N/FOF 990/T/t Z 0 DpiD A1E11.0 rue g' °F 3860124 1,-0 xy . �1 • D 000N S LANDS NR OF _1 HARRIS / 596/it84 % w ,' 'b! - N45013'00'W 6.22 N86°41 '30"W r i� LAKE 7.09 Y „ ov LANDS N/F OF TEEU (� E®{�.^(4E 990/18, Application Town of QueenburY fqa cog Board laemd W IIbMkneon cc RESOLUTION TO APPROVE WE PLAN 562012 T 47 20 22 ~ 4� THOMAS VALENTINE—JOHN CELESTE (�� b A dte pan w+vlwwm has been marls b ha agar I>lar,nbg e°am for the bYOwgg: appumant naa rerwvaled Zonlng Administrator � � 0 mAregaeftPWIftordra2vand auglaakKuelmnckae. Ewarsbnwomcaldaninuwuaraine TOWN OF UEENSBURY r' CEA requires Plareltrg Board review and apprwel. _. The PO made a lemmrcendmun b the MA on 91A812012:he ZBA approved the vanarm on 911V&2: t. LOCATION MAP fn ! V1 A few was edaanaaev em lwd on�z<Lrm1z NOT TO SCALE ca This application a aworrted wih all doe mentedo ,pubkc oomrtwnt,and son"bon meeml In bw No of record; ! i ( - MOTION TO A�R04 IT ELAN NO,�2n12 T♦pµec V I PNTLNE•JOHN Ir'P F� InvOdacatl by Haub Krebs who MWW brlle adopmn,a ox"by Brad Meg~: C . As per he MC UWn prepared by Staff. •\ I -� \ ;". sw.a-. \., ////��}} t� ,p.�,{ A: � j1) PulsueM b relevant seciaw of Vw Tom of Ouemsmry Zoning Cod"opler 179.9-M.Bw Punning L� ��� w.• '�`"'" Board has debnmwd 91d des poposal a fadin 818 repuirm orb a staled b to Zoning Code: ":A ��` .. j Ya. Msr+n w t, z I P 2) rypeusECWA; ' 3) Waiver regtaasta Wand:sbrmwaler mpnw,gred'ng,uldcrapYg,Ighlug penw and bW6WhY: 'r•Yj',l�� uyw.:• °'I'� r/ I 4) The Ines of deafn9 wil oonsara,a nocW butler zone,orange ,r mclion feron g shah be inwaked aroad thm areas and fwb venlied by CamwvAy Devewpnwnl stiff: "e.•.'' `���\ GW.:v. ••a j w 'G Lldtb /a°a quAa ay 5) The Sanitary S~"nemon flan nAW be advnkted to tlw Wastewater 0epar4rwnl ler b review, C: i approval,fbrMteng and veWecmn: / c f� Ale 6) daub We ae fwnlg added rn changed a / . , 'l • V ga &h toy permit a required. A buffing peand will not be issued ail the v(+Proved drheway pertnd has been p'ovided b h Ptenn6g Oltwe; a:e � f i� } T) ryng-Rg aignoE required prior b sgnalt-of Zerag ACrNnmrabr of the approved pms; "�'. ! r'+ �,° w LEGEND 8) Feel approved pans,In ounpAa ce with he Silo Plan,need be submitted b yes Carrara"Devekgr ent ZONING INFORMATION Fi/ :aM rb a s m T Depaunalt more any fui#am nemev'by lne Zzeg A&nvt**f or fAAL`g and Codes personnel. WR- WATERFRONT RESIDENTIAL � � `` 1! "b arB., w 9) The appicmd must meet win Stag Ow approval am Ma to muawe of I&dmg Pane ad/a the m UJ IRFO= IRON ROD FOUND ! begimlkgofmy site work- MINIMUM LOT SIZE. 2ACRE MINIMUM LOT WIDTH.' 150 feet IPF O= IRON PIPE FOUND 10)Subsequent Issuance of n,rues`pennas,k iudag mi3ng penmta is aepa4w on omnpfa'ce vAth hs and MINIMUM ROAD FRONTAGE: 150 feet J 7 j _ i •' ' Dl�'v�iMYfY 13. 2011' al Ww caddaw d foe resoblon; c.... r DOW 1"-2(Y `O-,= UTILITY POLE 11)Aaba plans b M*hal the site pen Is developed rio=t to 94 approved pans b be provided P691 10 SETBACKS .: rr '.Fy-jar ""^w'."'°'.• �. r �'. awiumee of ft wrki ofooaganwy; � 7 ° = WOODEN FENCE UNE FRONT:30 feet J Duff DPW thin 2591 day d Sep ernber,2012.by Ste bYOtig vie: �^ - = METAL FENCE LINE AYES: W Sgp M SGw wwo8 M Ford,i9 RIDE: 3 feet -. Megoeun,Mr.Krim,Mr.waver,Mr.Nwwnper REAR:30 feet 1 SHORELINE:50 feet i.t'!' / v '. i __; ""' S- 1 NOES: NONE ®= WELL x MkheeJ.O'Comor,Esq. MINIMUM PERCENT PERMEABLE: 75% .0 y!"" ;; . • ; MAXIMUM BUILDING HEIGHT.' 28 fast(16'accessory structures) L D - 0 N D N. r r y f ' BFEEf 1 OF i D1762 I DWG. NC. 760:54 227.18-1-12