2006-416 410Z TOWN OF QUEENSBURY
wow742 Bay RoadQueensbury,NY 12804-5902 (518) 761-8201
Community Development- Building &Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number. P20060416 Date Issued: Friday, September 28, 2007
This is to certify that work requested to be done as shown by Permit Number P20060416
has been completed.
Location: 35 BIRCH Rd
Tax Map Number: 523400-289-013-0001-022-000-0000
Owner: ALICE M GENTHNER
Applicant: ALICE M GENTHNER
This structure may be occupied as a:
Residential Addition By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the 41
45it
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
IF.T742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20060416 Application Number. A20060416
Tax Map No: 523400-289-013-0001-022-000-0000
Permission is hereby granted to: ALICE M GENTHNER
For property located at: 35 BIRCH Rd
in the Town of Queens bury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: ALICE M GENTHNER
21 KILEY Ln Residential Addition $18,500.00
QUEENSBURY,NY 12804 Total Value $18,500.00
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans &Specifications
2006-416
253 SQ FT RESIDENTIAL ADDITION
$75.00 PERMIT FEE PMD- THIS PERMIT EXPIRES: Wednesday, September 05, 2007
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the TON‘off" ensb ; 3 T s� y, September 05, 2006
SIGNED BY 4 Y for the Town of Queensbury.
Director of Building&Code Enforcement
--REGEE-.NEI;
2.....8- , 1T _ ._ OFFICE USE ONLY /
TAX MAP NO. 1 PERMIT NO. `��1� �f6 JUH 1-- �.���1'�;
FEES: PERMIT.156. RECREATION ENGINEERING `FOWNOF- ,-,.,;r.L:NSBURY
(If applicable) BUILDING AND CODE:
PRINCIPAL STRUCTURE:
APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO
REVIEW BEFORE ISSUANCE )OF A VALID PERMIT FOR CONSTRUCTION. 6er4i)
herAPPLICANT/BUILDER: ////fA�yj /40 LI Ar� OWNER: (�(� ,.� - iU a y'
ADDRESS: v<! 1`�,,d
ADDRESS: L_e i/ L/V
PHONE NOS. PHONE NOS. 7 ?3 - C2o Cf 6
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: //Ck/LLhy PHONE: '36 5 -5607
lumsimminimmmiase
SUBDIVISION NAME:
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT
APPLY TO YOUR z x o O Cd w U. v7
PROJECT 1 O p co J O _
o Q So
I- _Z
LU ¢ ¢ :- U) c., U) OLL F- U ai0s
SINGLE FAMILY ✓X 53 al of,
TWO-FAMILY
MULTI-FAMILY
(NO.of UNITS )
TOWNHOUSE
BUSINESS OFFICE
RETAIL-
MERCANTILE
FACTORY OR
INDUSTRIAL
ATTACHED
GARAGE(1,2,3)
OTHER
IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS:
ESTIMATED CONSTRUCTION COST: / 9, 5 O -0 FUEL TYPE:
HEAT TYPE: *HOW MANY FIREPLACE(S): RJ 0,-,,Q-AND/OR WOODSTOVES(S): ;Uo ru e
ZONING CATEGORY: (J✓ poi ARE THERE WETLANDS ON THIS SITE? P v
IS THIS A HISTORIC SITE? 0 ,
PROPOSED USE OF BUILDING OR ADDITION: &ranrl QL__
Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office
B 3-LGL 11-05
Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN?
ARE THERE EASEMENTS ON PROPERTY? 10A-
I acknowledge no construction activities shall be commenced prior to issuance of a valid
permit. I certify that the application, plans, and supporting materials are a true and
complete statement/description of the work proposed, that all work will be performed in
accordance with the NY State Building Codes, local building laws and ordinances, and in
conformance with local zoning regulations. I acknowledge that prior to occupying the
facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and a reeptiaj,the abov .
Signed
0/,/te-a441 jZ
Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction
codes or septic systems)
Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process,
application requirements or to schedule an appointment)
Permission is hereby granted to the above This application / proposed action described
Applicant to erect or alter the building herein is found to be in accordance with the
described herein in accordance with said zoning Laws of the Town of Queensbury.
Application:
d. . At
B /D G & CODES APP-0 AL ZONING APPROVAL
I►
D •
AT: DATE
QUESTIONS? CALL 761-8256 OR EMAIL
codesc queensbury.net
VISIT OUR WEBSITE FOR MORE INFORMATION
www.queensbury.net
:‘_- Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804
Queensbury Building & Code Enforcement - Reside i •1 Fi P • Inspection
Office No.(518)761-8256 Arrive: - �/ �e am/pm
P P
Date Inspection request received: Inspector's . . _ —
NAME: V\ ixer' PE'VIT#: i j -- /LOCATION: j ,�. D` E: V1W4�--•
TYPE OF STRUCTUI D _
Comments ,3
Yes No N/A
Building Number/Address visible from road < rpt/u VI -(4,3
Chimney Height/'B"Vent/Direct Vent Location q
Fresh Air Intake /e /erC / 4?
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete _
Platform at all exterior doors _
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches _
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sq.ft. _
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum`/s"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/3/4 hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/0[Temporary/Permanent]
evi ed 100405.doc
L:�Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form r s _
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building&Codes (518) 761-8256
Inspections per Permit
Permit# P20060416
Inspection Date Inspection Type
Approved/Denied Comments Permit Type Person Responsible
Approved Site Plan Inspection Report
Project Name:Alice Genthner
Project Location:35 Birch Road,Queensbury,NY
Tax Map No.: 289.13-1-22
Mailing Address:21 Kiley Lane,Queensbury,NY 12804
Site Plan No.:34-2006
Area Variance No.:40-2006
Building Permit No.:
Date: May 07,2007
Dear Alice Genthner:
During a site plan inspection on May 4,2007,your project was found to be developed as approved.
Should you have any questions or concerns please contact this office.
Sincerely yours,
Bruce Frank
Code Compliance Officer
_x Regular Mail _Certified Mail _ Hand Delivered(by B.Frank)
L:1Bruce Frank120071SPR and AV Reports\Genthner,Alice SP 34-2006&AV 40-2006 07may07.doc
9/20/2007 12:00:00AM Miscellaneous Residential Addition JENNIFER HENDERSON Staff
Miscellaneous 2006-416
sent permit expired letter(1st notice)
Queensbury Building & Code Enforcement - Reside'ti. final Inspection ' ^ a
-55- 9
Office No.(518)761-8256 Arrive: ' . .art: 7::.0 a
Date Inspection request received: _ Inspector's nitials:
NAME: �-��� P IT#: CD—"L M O
LOCATION: i 1 K1-\ 1:l 01) %ATE: <6--y-07
TYPE OF STRUCTURE:
Comments
Yes No N/A
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum'A"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofmg/3/4 hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Plain Certificatio•,if re wired Z•e-OLE_- 1 `
Okay to issue C/C • C/0 ' -mporary ermanen
L:\Building&Codes Forms\Building&Codesllnspection Forms\Residential Final Inspection Form revised_100405.doc
ID' 3D — I \--C,C
Queensbury Building & Code Enforcement - Residentia Oa! Inspection
Office No. (518)761-8256 Arrive: !�, -4 ;r -c art: �\:
Date Inspection request received: Inspector s Inttta
NAME: G ..0-u ER 41T#:
DLO-1-1 1(0
LOCATION: c3c� [j 1 PleA R flD A +E: 5—7 --1)--7
TYPE OF STRUCTURE:
i Comments
YesI& N/A
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
//
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade /
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/W' dow in stairwells safety ing
_ I/
Interior Smoke Dctors:
Every level: �f/�f/ Ev ry Bedroom: •
Outside every bedroomea:
Inter Connected: Battery backup: •
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spa•-• : inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents e _
• I. oom Fans,i ,o window _ 1
lumbi _-: J 9-0 b lV
,. .. ion insulation
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-of within 30 feet or within line of site
Oil Fu a shut-off en ance to furnace area `
Furnac /Hot Water a er operating �-u{z� f
Low wa oiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum%2"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/'/<hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical /
Final Survey Plot Plan
As : ' : is System/Sewer Dept.Inspection Sticker
"te Plan -ananceerequired FO k_i Com\'1t: k
am Certification,if required
Okay to issue C/C or C/0[Temporary/Permanent]
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised_100405.doc
Y-(a (0/1-
Rough
tomRough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection reque - :• i c
Queensbury Building & Code Enforcement Arrive:41--i^ •• ►e•. : lii' 'aim
742 Bay Road, Queensbury, NY 12804 Inspector's Inl . :
NAME: C.( PER IT #:
LOCATION: . INSPECT ON: i2.)c,
TYPE OF STRUCTURE: .)/2,-, P c ��
5T 614
�
• N/A
Rough Plumbing / Nail Plates
Plumbing Vent / Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
Pressure Test
Drain / Vent
Air / Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping _
Air / Head yV
O.P .I for 15 minutes
nsulatio Residential Check / Commercial Check
\Z"'
Na\
-IV- -'int, Attic Vent
Duct / Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
COMMENTS:
Mil
L:\Pam Whiting\Building&Codes\lnspection Forrns\Rough Numbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection reques - - v-e:
/Q)1) a4t)
Queensbury Building & Code Enforcement Arrive: 13 a prri ID-part: P-)7; aim
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: eil4N,es I PERMIT#: 02 ,c-//6.
LOCATION:_ j C5f 1d R — INSPECT ON: / , \A\37\4".
TYPE OF STRUCTURE:
A/6,, ISda-Ye.
Y N N/A
Rough Plumbing / Nail Plates J
Plumbing Vent/ Vents in Place ✓/
1 1/2 inch minimum Drain Size ,//
Washing Machine Drain 2 inch minimum ✓
Cleanout every 100 feet / change of direction
Pressure Test
Drain / Vent
Air) Head
•. . . • ft. above highest connection for 15 minutes
Pressure Test
-1/4/7/
4 _ .. y Piping
Air Head
I P.S.I for 15 minutes f
Insulation / Residential Check / Commercial Check
Proper Vent, Attic Vent
Duct / Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
COMMENTS:
L:\Pam Whiting\Building&Codes\lnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
70— a-e
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection re.- ec . e > A tr -
Queensbury Building&Code Enforcement Arrive: ` . Aart: t0, "r:-.4015.
742 Bay Road, Queensbury,NY 12804 Inspector's Mitt,
/
NAME: -71u , ef1`f" lie( PERMIT#: l l�
LOCATION: 7 I- C(� INSPECT ON: ' h`;r.
TYPE OF STRUCTURE:f
2 t vci- 2Th
�r am Y N N/A COMMENT
Framiri /
Attic Access 22"x 30"minimum
Jack Studs/ aders
Bracing/Bridgin -- 2tS0 w v • •-)(2._\SIND\P�✓
Joist han ers
Jack Posts Main Beams
Exterior sheeting nailed properly
12"O.C. \tv _- 1 kL1_. ‘.,LtV)V- 9--
Headroom 6 ft. 8 in. —‘A—A{A 6 - J 1j
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls �\
Metal Strapping for Notches Top Plate v D1 �� ` 1�
1 %2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
/ire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity ' .
Garage Fire Separation
House side 1/2 inch or 5/8 ' ch Type X
Garage side 5/8 inch T se X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection reque , c-' -•. v
Queensbury Building & Code Enforcement Arrive: \U7- 4, 2. part: 1U-it)
742 Bay Road, Queensbury, NY 12804 Inspector's Initi.
NAME: 3\11 r- k 766v4A-e7 PERM #: --44C
LOCATION: Z& R INSPECT ON: /0/4/5:,2_06(..,
TYPE OF STRUCTURE:
'11--
Y N N/A 1
Rough Plumbing / Nail Plates >JJ
Plumbing Vent/ Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
Pressure Test
Drain / Vent
Air / Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air / Head
50 •.S.I for 15 minutes
nsulati•- 'esidential Check / Commercial Check — \1L�
••- Vent, Attic Vent
Duct / Hot Water Piping Insulationu(2-
If required unheated spaces ;-`% A
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
COMMENTS:
L:\Pam Whiting\Building&Codes\lnspection Forms`Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
771US' /o//r/O ,
Framing / Firestopping Inspection Report ( c
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm epart: ) '3 m/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials;/1
NAME: .l PERMIT#: ' / /p
LOCATION: 3� 5;'�i�- INSPECT ON: V()
TYPE OF STRUCTURE: V)
Y N N/A COMMENTS
Framing
Attic Access 22"x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C. V
Headroom 6 ft. 8 in.
Stairwells 36 in. or more �1�/�
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 'A(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
=..: e • . . less on center
Ice and water shield 24 nches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side 'A inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
41....--// 'RibiThi_ --.F--(56
Foundation Inspection Report
Office No. (518) 761-8256 Date Ins ction r est rec-'•-.r
Queensbury Building&Code Enforcement Arrive: P De.. : m
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: 6jt f/l iTe(' PERMIT 11: 00'
---12/---12//6."1�
LOCATION: ,..3.4- / ,'mi. Rd INSPECT ON: -E -04:
TYPE OF STRUCTURE:
Comments
rli N N/A
Footings} {�,,,} ���1 j„
0 k - ' 1 1
Piers \-7,*N\ �'/� Y N N/A
1
Monolithic Slab
(BL-
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wailpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R- _
Rough Grade 6 inch drop within 10 ft.
L•\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Reportdoc
Last printed 12/20/2005 9:24:00 AM