Loading...
2006-570 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 CL Community Development- Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20060570 Date Issued: Thursday, January 31, 2008 This is to certify that work requested to be done as shown by Permit Number P20060570 has been completed. Location: 20 BELLE Ave Tax Map Number. 523400-304-017-0001-049-000-0000 Owner KATHY DUFOUR Applicant: KATHY DUFOUR This structure may be occupied as a: Residential Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the /f / property owner of the responsibility for compliance with Site Plan, A. Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20060570 Application Number: A20060570 Tax Map No: 523400-304-017-0001-049-000-0000 Permission is hereby granted to: KATHY DUFOUR For property located at: 20 BELLE Ave in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: KATHY DUFOUR 20 BELLE Ave Residential Alteration QUEENSBURY,NY 12804 Total Value Contractor or Builder's Name/ Address Electrical Inspection Agency Plans &Specifications $0.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Saturday, August 18, 2007 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Tow of Qti nsbu' , Fri ay''Au ust 18, 2006 SIGNED BY r for the Town of Queensbury. Director of Building&Code Enforcement r OFFICE USE ONLY , 4A43 r TAX MAP NO. 1.a, PERMIT N N . p Utile FEES: PERMIT I r e- REATION �.� AU ,1 5 2006 i ENGINEERING (If ap�lica le) :i A'�:'N OF�J I , ° r, PRINCIPAL STR LI CT LIRE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: Xlydiii t'r ,e5V -A.{,fic OWNER: /// 7,---(944;4119 ADDRESS: // / rdeet- �°�'�'dui P Pnccq�.� A7 ADDRESS: a /e//C i1- -- ' y PHONE NOS. ,c-ir 7g 3-go y PHONE NOS. 7/3 - L% / G> 1 � CONTACT PERSON FOR BUILDI &.CODES-COMPLIANCE.- e ; iee//U PHONE: 7f,_1--.2 -2- ---- LOCATION OF PROPSTY: c9a 6e%/p! !r/ v12— SUBDIVISION NAME: 444 PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT Z APPLY TO YOUR Z 0 IX ix C! o PROJECT 0 O co w W -l � � � W J O = S D F- L` U z Q Q e- o) Nu) O � OL~L Ce SINGLE FAMILY 461sC - X ' Y.0 70!) TWO-FAMILY MULTI-FAMILY (NO.of UNITS ) TOWNHOUSE TOWN Y'' F QU .L NSBURY BUSINESS OFFICE b U I Lr LJ I I V��.� 8e.31--J-L,'/.' 110 RFV[FWED BY ivy- Lir � PT. RETAIL- ri�� MERCANTILE [�A-� __ FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSI ESS:g ESTIMATED CONSTRUCTION COST: 1 / 000 , FUEL TYPE: HEAT TYPE: *HOW MANY FIREP E .): l AND/OR WOODSTOVES(S): ZONING CATEGORY: ARE THERE WE NDS10 1 HIS SITE? IS THIS A HISTORIC SITE? \..) PROPOSED USE OF BUILDING OR ADDITION!? *Please complete a separate Application for"Fuel Burni1 Appliances&Chimneys"available in our office \I B 3-LGL 11-05 011a Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 ! a ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree e above. Signed Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: di', BUILDING & CSDE• PPROVAL ZONING APPROVAL DATE DATE J QUESTIONS? CALL 761-8256 OR EMAIL codesAqueensbury.net VISIT OUR WEBSITE FOR MORE INFORMATION www.queensbumnet aTown of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: //,7) am/p, j�epart: am/pm Date Inspection request received: Inspector s Initials: ` J�i^ NAME: DU 1 Ut PERMIT#: 06-7,37 LOCATION: &j/4_ Av DATE: TYPE OF STRUCTURE: /117` Comn Yes No N/Av Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake S' fpr'j�{.� �- -e 93 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete /e• ler i /G,/Q7 Platform at all exterior doors T Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more 21-1 Act, c.e ,C' oh Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall /Ci�/ /C-7 Interior/Exterior Railings 34 inches to 38 inches T_ /U/Z. Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet r h��/C-C 5 i 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade _ :2 / 4/0 Interior privacy/trim/doors/main entrance 36 inches ---/// Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping fmished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler _ Relief Valve(s)installed/Heat Trap/Water Temp 110 _ Enclosed Stairs Sheetrock Underside minimum%z"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/Ya hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electricalft/ Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certificatio• i.'red Okay to issue C/C ,. C/0 '-mporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc Mojicl, Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: MU am/pm Depart: am/pm Date Inspection request received: Inspector's Initials: NAME: boefoor PERMIT#: 16 AFC) LOCATION: 2a &o/k _ Avcr DATE: 1 TYPE OF STRUCTURE: ge6 /[1] Comments l Yes No N/A i / Building Number/Address visible from road � �� Chimney Height/"B"Vent/Direct Vent Location r� �!' it Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches /O/ ., Roof Complete/Exterior Finish Complete _ /diet— Platform at all exterior doors _ Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq. ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler _ Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'`h"Gypsum Basement stairs closed rise>4 inches _ Garage Floor Pitched Garage fireproofmg/Y4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure ` 7 Final Electrical / ( Final Survey Plot Plan / �/l�i�ecf ^i As Built Septic System/Sewer Dept.Inspection Sticker c,/ .1-f\-s Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0[Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised 100405.doc CD / )E s 6 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Ins section r- . - e. i •d: Queensbury Building&Code Enforcement Arrive: ♦ : . .` epart: - a • . 742 Bay Road,Queensbury,NY 12804 Inspector's mit(; r NAME: V c� PERMIT#: CJ '— ALJ LOCATION: l7 / // 4x._ INSPECT ON: — TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses ; • 6 ft. or less on center / Ice and water shield = 'nches from wall i /1 • - .. . •: , , our 1� Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade