Loading...
2006-663 TOWN OFQ UEENSBURY wow742 Bay Road, NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number. P20060663 Date Issued: Monday, January 10, 2011 This is to certify that work requested to be done as shown by Permit Number P20060663 has been completed. Tax Map Number. 523400-309-009-0002-001-000-0000 Location: 200 LUZERNE Rd Owner: HOMESTEAD VILLAGE L P Applicant: HOMESTEAD VILLAGE L P This structure may be occupied as a: Septic Alteration Commercial By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the :00t-- property owner of the responsibility for compliance with Site Plan, c_4-\1 ` Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. ice` TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 128045902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20060663 Application Number. A20060663 Tax Map No: 523400-309-009-0002-001-000-0000 Permission is hereby granted to: HOMESTEAD VILLAGE L P For property located at: 200 LUZERNE Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: HOMESTEAD VILLAGE L P 4294 ROUTE 5 Septic Alteration Commercial CALEDONIA, NY 14423 Total Value Contractor or Builder's Name/ Address Electrical Inspection Agency Plans &Specifications 2006-663 SEPTIC ALTERATION 84 ALPINE AVE $35.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Thursday, September 27, 2007 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town cif-Que sbu WedIesI ay, September 27, 2006 SIGNED BY i for the Town ofeensb Qu ury. Director of Building&Code Edo cement SOT a / _Z _ / OFFICE USE ONLY I ' i TAX MAP NO. PERMIT N / ; O• — ERMIT E 1� f' , APPROVALS: ZONING TOWN CLERK I ; ,; APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT: PERMITA PERMIT M ST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJE TO REVIEW BEFORE ISSUANCE OFA VALID OWNER: rtitR.e_PT-600 1/4)Pe._ INSTALLER' 19-ie ✓2. /ei-t.).e...c._ ;:tr(]j ce ADDRESS: /.6,-.) [O-)2— ' - ,4 /�v goy ADDRESS: V /� ZJ,y �j F / PHONE NOS.$?5. ''''--9(3-3 -,..5a/// PHONE NOS. 9.6 — O c% J/� LOCATION OF INSTALLATION: pg f2 A./k n-(_* NO.OF I RESIDENCE INFORMATION: YEAR BUILT BEDROOMS ` X COMPUTATION= i = TOTAL DAILY FLOW F I. GARBAGE GRINDER 1980 or older E X 150 gallon per bedroom 1 I- - INSTALLED? 1981 -1991 X I 130 gallon per bedroom I = 1SPA OR HOT TUB i 1992-present I X i 110 gallon per bedroom - I INSTALLED? PARCEL INFORMATION: kr p4a_ 0‘24-,,..,,,./ peA7tif ✓ TOPOGRAPHY: FLAT ROLLING (Y., STEEP SLOPE %SLOPE ✓ SOIL NATURE: SAND jC LOAM CLAY OTHER ✓ GROUNDWATER: AT WHAT DEPTH? BEDROCK/IMPERVIOUS MATERIAL: AT WHAT DEPTH? ✓ DOMESTIC WATER SUPLY: MUNICIPAL.2 WELL (IF WELL: WATER SUPPLY FROM ANY SEPTIC-SYSTEM ABSORPTION IS FT. ) ✓ PERCOLATION TEST: RATE IS PER MIINUTE PER INCH (TEST TO BE COMPLETED BY A LICENSED PROFESSIONAL ENGINEER OR ARCHITECT) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect (unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each garbage grinder, spa or whirlpool tub.Ap ✓ SEPTIC TANK: (®c--) GALLON (MIN. SIZE IS 1,000 GAL.) TILE FIELD: EACH TRENCH �3 FT. ✓ TOTAL SYSTEM LENGTH: 4�3 FT. SEEPAGE PIT(S): HOW MANY? P/r ✓ SIZE OF EACH FT. X FT. ✓ SIZE OF STONE TO BE USED: # 2- /DEPTH OR THICKNESS //2-- FT. ✓ BED SYSTEM SIZE: X ✓ ALTERNATIVE SYSTEM: LENGTH AND/OR SIZE ✓ HOLDING TANK SYSTEM:(If required) NO. OF TANKS: /SIZE OF EACH ✓ GALLONS./TOTAL CAPACITY: GAL. €i NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN • APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. ii For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of QUESTIONS? CALL 761-8256 OR EMAIL Qus ry Sanitary Sew Disposal Ordinance. codes@queensburv.net VISIT OUR WEBSITE FOR MORE INFORMATION www.queensburv.net Signat re of Person R s ofisibie Date QiTown of Queensbury• Community Development Office • 742 Bay Road, Queensbury, NY 12804 DomSTATE OF NEW YORK DEPARTMENT OF HEALTH Glens Falls District Office 77 Mohican Street, Glens Falls NY 12801 (518)793-3893 Fax (518) 793-0427 Antonia C. Novello, M.D., M.P.H., Dr.P.H. Dennis P. Whalen Commissioner Executive Deputy Commissioner September 7, 2006 James Mitchell, P.E. S E P Environmental Design Partnership, LLP • c"(`� 900 Route 146 Clifton Park, NY 12065 06 --6- 6 Re: Letter of Approval 3 Homestead Village Mobile Home Park, Lots 36 84 8,79 Town of Queensbury, Warren County Dear Mr. Mitchell, We have, this day, approved the plans for the construction of the on-site wastewater treatment systems for the Homestead Village Mobile Home Park on Lots 36, 84,78,79. The approved plans were designed by James Mitchell, P.E. of Environmental Design Partnership, LLP, titled Septic Design prepared for Lots 78 and 79, Septic Design prepared for lot 36 and Septic Design for Lot 84. These plans are all dated August 15, 2006. This approval is conditional upon the following items. • That the proposed facilities shall be installed according to the approved plans. • The design engineer must inspect construction. • When complete, the design engineer must certify in writing to the Town of Queensbury, Building and Code Office, and this office that construction was completed according to the approved plan. • This approval will expire two years from today. After that time if construction is not complete, plans must be resubmitted to this office for approval. Enclosed you will find one set of the approved plan. Your office is responsible for distribution of the approved plan to the Town of Queensbury, the applicant, and the contractor. This office will retain one copy in our file here in Glens Falls. If you have any questions, please call me. Sincer ly, isbtAG Mike Sha Senior Sanitary Engineer cc: Homestead Village MHP, Applicant Town of Queensbury Building Office Anita Gabalski Kristen Sayers 5./0 CiS //tiS ecri0 Septic Inspection Report Office No. (518) 761-8256 Date Inspection requ i : `! Queensbury Building & Code Enforcement Arrive: .117_2.-14L a am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's • NAME: /but- ref PERMIT NO.: %• LOCATION: , -1// /). rye /-kit. INSPECT ON: — — RECHECK. Comments and/or diagram Soil Type: Sand / Loam / Clay Type of Water: Municipal / Well Water eq) Waterline separation distance ft. / " Well separation distance ft. 7-27-C7 Other wells: ft. Well Casing Length 50' + / - Y N N/A [150'to well required if NO] Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field / Pit _ Opening Sealed: Y N End Cap Y_ N Inlet/Outlet Pipes & Baffles Y N Manholes 12"or less below grade Y N [provide extension collar if Yes] Y_ N Location / Separations Foundation to tank ft. Foundation to absorpon _ ft. Separation of Pits _. ft. Conforms as per Plot Plan i N Engineer Report and As-Built Y N ETU Maintenance Contract Y N _provided Location of System on Property: Front Re.. Left Side Right Side Middle Front Middle Rear S stemUseS . s: Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved L:\Pam whiting\2010\Building Codes Forms\Inspection Forms\Septic Inspection Report`03 29 10.doc 1110111111 • ENVIRONMENTAL DESIGN PARTNERSHIP,LLP January 7, 2011 Queensbury Building& Code Enforcement 742 Bay Road Queensbury, NY 12804 Via email johno@queensbury.net Attn: John O'Brien Re: Homestead Village Mobile Home Park Lot 84 Alpine Dear John: On September 27, 2006 I inspected the above referenced Homestead Village Mobile Home Park septic installation. The purpose of this visit was to observe the installation of the new septic system designed by EDP dated August 15, 2006. Based on my review of the plans and observation of the installation it is my opinion that the system was installed substantially in compliance with the intent of the design plans. Please contact me should you have any questions regarding this system. Sincerely, C:39ffe0■251.5. James E. Mitchell, P.E. 900 Route 146,Clifton Park, New York 12065 phone(518)371-7621 -fax(518)371-9540 10-12_ 06-1)10E- 771:1l'7 q- 27 - 6 • Septic Inspection Report Office No. (518) 761-8256 Date Inspection -. •i- ed: Queensbury Building &Code Enforcement Arrive: ►=.iy1j1%S;;,rr D-•.rt: (a-J' 742 Bay Rd., Queensbury, NY 12804 Inspector's Initia s: . NAME: A),;1\i----,:fr.7V ) 1HMIT NO.: heLOCAON: /9P tie , ,SPECT ON: r Z 7- RECHECK: Comments and/or diagram Soil Type San / i.m-f, lay (— _�i Type of . e unicipal Well Water 5 ` Waterline separa is .nce ft• _ Well separation distance ft. Other wells: ft. Absorption Field: Total length • ft. _/4/ / Length of each trench TM. . • ,3'6-I / 5-3 Depth of trenches ,,.ft. Size of Stone V. Seepage Pits: Number Size: x Stone Size: __.__ ___ — Piping Size Type Building to tank ,.�" -) 1U TO Tank to Distribution Box `` b 04-` -> Distribution Box ttS field/ Pit H" h{O¢ .\---‘) W Opening Sealed• / Partial End Cap Inlet/Outlet Pipes &Baffles Y N Location / Separations Foundation to tankZ .. ft. Foundation to absorption ft. Separation of Pitsft. ff� Cons peLPlot Plan Y_N 7 AJ G 1J � -�j En firer Re..rt an. As-Built Y Location of System o ' .:-.. ' --------(- V-E_ 61.- 6--Z--1—, Front Rear eft Side ight Sid- Middle Fron Middle Rear System Use Status: • ',proved P:rtial Approved an. eeds to be re-inspected, please call the Building &Codes Office dfro* .pproved Last revised 021006 Last revised 1/6/05 INSPECTION REQUIREMENTS: ENGINEER OF RECORD TO INSPECT TRENCHES PRIOR TO BACKFILLING. LOT 127 PROPOSED 4" PVC SDR —35 (GASKETED BELL) AT 1% MIN. PROPOSED DISTRIBUTION BOX #1 (SEE DETAIL — SHEET 2) EXISTING MOBILE HOME LOT 86 NO TE: NOF? TH LOT 128 EX. FEXGBLDG. U PROPOSI ABSORP'Iivry rlcw 3 LINES AT 150 FT. EA. (SEE DETAIL — SHEET 2) 1 LOT 85 PARKING AREA LOT 129 NEW YORK STATE DEPARTMENT OF HE GLENS FALLS DISTRICT OFFICE Dated: Q 1-7f v These plans for: -S tom"' are hereby the State W O O D S PROPOSED 1000 GALLON SEPTIC TANK (SEE DETAIL — SHEET 2) PROPOSED 4" PVC SCH 40 AT 2% MIN. EXISTING MOBILE HOME 3 BEDROOM UNIT LOTI 84 ALPHINE AVENUE of MOBILE HOME UNITS TO BE PLACED WITH A MINIMUM 10 FT. HORIZONTAL SEPARATION. LOT 130 yY. "i: ?T.v�4�t�.• BORING AND PERCOLATION TEST - TEST PERFORMED ON AUGUST 10, 2006 0-8' MEDIUM FINE SAND PERCOLATION RATE APPROXIMA TEL Y ONE MINUTE SEPTIC DESIGN: APPLICATION RATE = 1.2 GAL./SF/DAY 3 BEDROOMS AT 100 GALLONS/BEDROOM =300 GALLONS USE 3 LINES AT 50 FT. EACH (SPACED 6 FT. ON -CENTER) CONSTRUCTION NOTES. 1) CONSTRUCTION OF ABSORPTION FACILITIES SHALL NOT OCCUR WHEN THE GROUND IS FROZEN OR THE SOIL MOISTURE CONTENT IS HIGH. IF A FRAGMENT OF SOIL FROM APPROXIMATELY NINE INCHES BELOW THE SURFACE CAN EASILY BE ROLLED INTO A RIBBON INSTEAD OF CRUMBLING, THE MOISTURE CONTENT IS TOO HIGH FOR CONSTRUCTION PURPOSES. OBVIOUSLY, SOME SILT OR CLAY MUST BE PRESENT FOR A RIBBON TO BE FORMED. 2) TRENCH LOCATIONS AND DEPTHS SHOULD BE MARKED BY STAKES BEFORE TRENCHES ARE EXCAVATED. THE NATURAL SURFACE SHALL NOT BE SIGNIFICANTLY DISTURBED. IF THE SITE IS REGRADED OR SIMILARLY DISTURBED, THE SOIL SHALL BE ALLOWED TO STABILIZE (I.E., SETTLE NATURALLY FOR A PERIOD OF AT LEAST SIX MONTHS, INCLUDING AT LEAST ONE FREEZE—THAW CYCLE) AND NEW PERCOLATION AND DEEP HOLE TESTS CONDUCTED. HEAVY EQUIPMENT USE IN THE DESIGNATED ABSORPTION SYSTEM AREA SHOULD BE MINIMIZED TO PREVENT SOIL PERMEABILITY REDUCTION DUE TO COMPACTION PLUS POSSIBLE TRENCH CAVE—IN AND DISTRIBUTION PIPE MISALIGNMENT/BREAKAGE. 3) AFTER A FINAL GRADE CHECK, TRENCH EXCAVATION MAY BEGIN. TRENCH DEPTH SHAD_ BE AS SHALLOW AS POSSIBLE, BUT NOT LESS THAN 18 INCHES. TRENCHES SHALL BE EXCAVATED TO DESIGN DEPTH WITH BOTTOMS PRACTICALLY LEVEL. 4) FOLLOWING EXCAVATION, THE TRENCH BOTTOMS SHOULD BE GRADED BY HAND. THE BOTTOMS OF THE TRENCHES SHOULD BE CHECKED BY A TRANSIT, ENGINEER'S LEVEL, OR CARPENTER'S LEVEL TO ASSURE THAT EACH iS PRAC'RCALi Y LEVEL. 71' EE CH BGTT01,4S AND SiCEWALLC. SHOULD BE IMMEDIATELY RAKED AFTER FINAL GRADING AND AT LEAST SIX INCHES OF AGGREGATE PLACED IN THE TRENCHES. 5) GRAVITY DISTRIBUTOR PIPE SHALL BE CAREFULLY INSTALLED AT A SLOPE OF h6 TO X32 INCH PER FOOT. PRESSURE OR DOSED DISTRIBUTOR PIPE SHALL BE INSTALLED LEVEL. GRADES SHALL BE DETERMINED BY AN ENGINEER'S LEVEL, TRANSIT OR CARPENTER'S LEVEL. AN EASY METHOD OF MEASURING THE %6 INCH PER FOOT SLOPE FOR DISTRIBUTOR PIPE IS TO TAPE A X4 INCH BLOCK TO ONE END OF A STRAIGHT FOUR FOOT BOARD. BY PLACING THE BLOCKED END WITH THE BLOCK FACING DOWN ON THE DOWNSTREAM TOP OF THE DISTRIBUTOR PIPE, A CARPENTER'S LEVEL CAN BE USED TO DETERMINE THE %6 INCH PER FOOT SLOPE. A Xs INCH BLOCK SIMILARLY USED WOULD RESULT IN A X32 INCH PER FOOT SLOPE. ANOTHER METHOD USED TO ESTABLISH THE GRADE OF DISTRIBUTOR PIPE IS BY BATTER BOARDS. AGGREGATE SHALL BE INSTALLED IN THE TRENCHES TO A DEPTH OF AT LEAST TWO INCHES ABOVE THE TOP OF THE DISTRIBUTOR PIPES. ADDITIONAL AGGREGATE MAY BE REQUIRED TO BRING THE TOP OF THE AGGREGATE TO WITHIN SIX TO 12 INCHES OF FINAL GRADE. 6) AFTER THE UPPER AGGREGATE IS PLACED IN THE TRENCHES, THE GEOTEXTILE, UNTREATED BUILDING PAPER, HAY OR STRAW IS TO BE IMMEDIATELY INSTALLED ON THE AGGREGATE AND THE TRENCH BACKFILLED WITH EXCAVATED SOIL. IF THE TRENCHES CANNOT BE IMMEDIATELY BACKFILLED, THE TRENCHES SHOULD BE TEMPORARILY COVERED WITH AN IMPERVIOUS MATERIAL, SUCH AS TREATED BUILDING PAPER TO PREVENT SIDEWALL COLLAPSE AND SILTATION INTO THE AGGREGATE. 7) THE EARTH BACKFILL IS TO BE MOUNDED SLIGHTLY ABOVE THE ORIGINAL GROUND LEVEL (I.E., NOT COMPACTED) TO ALLOW FOR SETTLING. FOLLOWING SETTLEMENT, THE ENTIRE AREA SHOULD BE GRADED WITHOUT THE USE OF HEAVY EQUIPMENT AND SEEDED WITH GRASS. HEAVY EQUIPMENT SHALL NOT ENTER THE ABSORPTION FACILITY AREA OR THE PROPOSED EXPANSION AREA AFTER THE SUBSURFACE SEWAGE TREATMENT SYSTEM HAS BEEN CONSTRUCTED. r -_-T. LOT 83 � - � I TOWN Q CSU Rlj BUIL DING PT. y REVIEWED B - jRl1ia TIA Ir eI ati �. tq jr)Q'; .f0 L R9S 9AI? -- _ $ _ DATE----- --- - -- -� 1t SHEET 1 OF 2 - SEP T/ C DESIGN PREPARED FOR 0.00f, �- I, - �A. LOT 84 ALPHINE AVENUE HOMES TEA D VILLAGE TOWN OF QUEENSBUR Y WARREN COUNTY, NEW YORK SCALE: 1 " = 20' AUGUST 15, 2006 ENVIRONMENTAL DESIGN PARTNERSHIP, LLP 900 ROUTE 146 CLIFTON PARK, N.Y. 12065 (518) 371-7621 ENGINEERING LANDSCAPE ARCHITECTURE LAND SURVEYING JAMES E. MITCHELL P. E. 53,337 HEAVY DUTY MANHOLE FRAME FINISH GRADE /-AND COVER BY CAMPBELL OR EQUAL _ IIII-� -IIII-III III=IIII= I—III= N _ - ACCESS EXTENSION ASPHALTIC - (MH GRADE RINGS) SEAL =I�I�- =IIII= 2 I.D. AS PER FORT MILLER OR EQUAL (AS REQUIRED) INLET I OUTLET 4" OR —� 3" MIN.- I I FA� _BLDG.SEWER WATER TIGHT JOINT (TYP.) SANITARY II- PARGE W/NON-SHRINK GRO T TEE z w 4" MIN. INSIDE & OUT ALL JOINTS BELO FULL � o SANITARY TEE LIQUID LEVEL TO BE BITUMINOUS WATERTIGHT AND INTERIOR - o LEAKAGE TESTED COAT Q I I PRIOR TO BACKFILLING KOP 300M _� I I BAFFLE WITH OR EQUAL I I 4"X18" MIN. MAY NOT BE REQUIRED 6" TO 12" LAYER PEA GRAVEL OR CRUSHED STONE SECTION VIEW BEDDING LAYER NOTE: 24" I.D. TAPERED PLUG (TYP.) INLET INVERT IS 3" ABOVE ASPHALTIC (2" MIN.) SEAL THE SLOPE OF THE OUTLET PIPE BETWEEN THE SEPTIC TANK AND THE DISTRIBUTION BOX TO BE Y4" PER FT. m INLET OUTLET THE SLOPE OF THE INLET PIPEFN BETWEEN THE RESIDENTIAL UNIT ANDNOTE: THE SEPTIC TANK TO BE Y4" PER FT. i I\\ BAFFLE MAY NOT BE BAFFLE NOT IR REQUIREED TTANKSLESSS THAN10FT.LENGTH I „D" PLAN VIEW TANK SIZE MIN. LIQUID DEPTH "A" TANK DIMENSI-ONS "B"X"C" "0" "1" VU 1 JIUG HEIGHT 1000 GAL. 5'-0" 4'-3" x 8'-2"= 5'-6" 5'-9" 6'-8" SEPTIC TAN NOT TO SCALE WHERE TRENCH SHIELD IS USED =7F rte.. ,, WITH THE APPROVAL OF THE ENGINEER, SHEETED TRENCH PAYMENT LIMITS WILL APPLY. ALL BACKFILL MATERIAL TO BE PLACED IN 8" LIFTS AND BE COMPACTED TO 95% STANDARD PROCTOR (ASTM D698).. DEBRIS, FROZEN MATERIAL, LARGE--- CLODS ARGECLODS OR STONES, ORGANIC MATTER, OR OTHER UNSUITABLE MATERIALS SHALL NOT BE USED AS BACKFILL. SELECTED GRANULAR FILL PLACED IN 6" LIFTS AND MECHANICALLY TAMPED ORS A.O.B.E. SEE NOTES 1&2. CRUSHED STONE OR SELECT GRANULAR MATERIAL AS ORDERED BY ENGINEER (MECHANICALLY TAMPED) OR A.O.B.E. SEE NOTE 2_ FOR UNSTABLE TRENCH BOTTOM USE ADDITIONAL DEPTH OF STONE AS NECESSARY TO PROVIDE A FIRM FOUNDATION. VSELECTED GRANULAR FILL TO BE PLACED UNDER PAVEMENT 1 1 TRENCH SLOPES ARE GIVEN FOR MAX. PAYMENT LIMITS ONLY FOR 3 PEN CUT AND ARE NOT INTENDED 3 TO REPRESENT STABLE SLOPES UNDER FIELD CONDITIONS. NOTES: 1) NATIVE EXCAVATED GRANULAR MATERIAL MAY BE USED IF APPROVED BY THE ENGINEER. (HEAVY DUTY SEPTIC TANK) FORT MILLER OR EQUAL PAVEMENT OR ORIGINAL GROUND A.O.B.E. = AS ORDERED BY ENGINEER NOTE: CONTRACTORS MUST COMPLY WITH ALL LOCAL, STATE, & FEDERAL SAFETY REGULATIONS (OSHA & N.Y.S. D.O.T.) _NOT INTENDED TO REPRESENT A SAFE SLOPE _6" WIDE GREEN PLASTIC LOCATOR TAPE, MARKED "CAUTION SEWER BELOW" TRACER WIRE #8 THNN STRANDED COPPER OR STAINLESS STEEL TRENCH DETAIL. NOT TO SCALE FOR SETTLING –IIII-1 111= —IIII— IIII—IIII=1 I I—IIII—IIII TERRATEX No. 2 NONWOVEN —IIII— CONSTRUCTION FABRIC OR i (( EARTH -IIII —IIII– EARTH –IIII— UNTREATED BUILDING PAPER BACKFILL -IIII=I BACKFILL I=IIII OR STRAW TOP OF AGGREGATE PVC MIN. TO BE WITHIN O 00 00 O/ 6"-12" OF SURFACE 8 O RAKE ANY PERFORATIO OINT 2 SMEARED TRENCH O WALLS O 0 O 00 �00 GROUNDWATER BEDROCK /OR IMPERVIOUS LAYER CROSS SECTIONAL VIE M0-omAyWA CRUSHED STONE OR� WASHED GRAVEL / �4 TO 1Y2" W LONGITUDINAL VIEW TERRATEX NO. 2 NONWOVEN CONSTRUCTION FABRIC NT—RI IEAT-_ED BUILDING PAPEIRIOR PERMEABLE PI ,E R MEABLE GEOTEXTILE LAYER OF STRAW IIII II IIII= OO O o 1-7 FLOW PROVIDE CAPS 0 o c 0 0 0 0 0 0 0 0 0 11 0 00 00 0 0 0 0 0 0 0 0 0 0 0 0 o ON LINE ENDS Cl 00 OO �O 00 OO D O SLOPE PIPE Na"–Ya2" PER FT. _ SPACING OF ABSORPTION TRENCH 6' O.C. TRENCH PROFILE �� ABSORPTION TRENCH DET=AIL NOT TO SCALE TRENCH BOTTOM TO BE NEAR LEVEL AND RAKED 2" THICK RIGID POLYSTYRENE INSULATION - Ice' }` tiyY4= LOCATIONS WITH LESS THAN 4' COVER). EXTEND TO MIN. 4' BELOW GRADE. - 6" MIN. FOR PIPE T2" DIA. AND SMALLER a .0 °• —� 12" MIN. FOR PIPE 14" DIA. AND LARGER WHERE A WATER TABLE CONDITION EXISTS STONE BEDDING SHALL BE WRAPPED IN A ON -WOVEN GEO-TEXTILE ENVELOPE 1. PIPE JOINTS TO BE SEALED WITH (FABRIC EQUIVALENT TO AMOCO 4545) 2) CRUSHED STONE NOT TO EXCEED #2 IN SIZE. GRANULAR FILL TO MEET THE FOLLOWING REQUIREMENTS: 0 % IN EXCESS OF 3" 25 %-75% PASSING #4 SIEVE 0 %-15% PASSING #200 SIEVE { TRENCH DETAIL. NOT TO SCALE FOR SETTLING –IIII-1 111= —IIII— IIII—IIII=1 I I—IIII—IIII TERRATEX No. 2 NONWOVEN —IIII— CONSTRUCTION FABRIC OR i (( EARTH -IIII —IIII– EARTH –IIII— UNTREATED BUILDING PAPER BACKFILL -IIII=I BACKFILL I=IIII OR STRAW TOP OF AGGREGATE PVC MIN. TO BE WITHIN O 00 00 O/ 6"-12" OF SURFACE 8 O RAKE ANY PERFORATIO OINT 2 SMEARED TRENCH O WALLS O 0 O 00 �00 GROUNDWATER BEDROCK /OR IMPERVIOUS LAYER CROSS SECTIONAL VIE M0-omAyWA CRUSHED STONE OR� WASHED GRAVEL / �4 TO 1Y2" W LONGITUDINAL VIEW TERRATEX NO. 2 NONWOVEN CONSTRUCTION FABRIC NT—RI IEAT-_ED BUILDING PAPEIRIOR PERMEABLE PI ,E R MEABLE GEOTEXTILE LAYER OF STRAW IIII II IIII= OO O o 1-7 FLOW PROVIDE CAPS 0 o c 0 0 0 0 0 0 0 0 0 11 0 00 00 0 0 0 0 0 0 0 0 0 0 0 0 o ON LINE ENDS Cl 00 OO �O 00 OO D O SLOPE PIPE Na"–Ya2" PER FT. _ SPACING OF ABSORPTION TRENCH 6' O.C. TRENCH PROFILE �� ABSORPTION TRENCH DET=AIL NOT TO SCALE TRENCH BOTTOM TO BE NEAR LEVEL AND RAKED V INU I I U NEW YORK STATE Falls D EP Rtr M N 8E HEAL 7ii ��++�/CC n r� Refer to first sheet for approved date and signature, SHEET T L �F SA NI TA R Y E TA IL S ICOR LOT 84 ALPHINE AVENUE HOMESTEAD VILLAGE TO WN OF QUEENSBUR Y WARREN COUNTY, NEW YORK SCALE: 1 " = 20' AUGUST 15, 2006 ENVIRONMENTAL DESIGN PARTNERSHIP, LL 900 ROUTE 146 CLIFTON PARK, N.Y. 12065 (516) 371-7621 ENGINEERING LANDSCAPE ARCHITECTURE LAN® SURVEYING JAMES E. MITCHELL P. E. 553,337 X THE SLOPE OF THE OUTLET PIPE BETWEEN THE RESIDENTAIL UNIT AND THE SEPTIC TANK TO BE 4" PER FT. GRADE NO TE: 1. PIPE JOINTS TO BE SEALED WITH ASPHALTIC MATERIALS OR EQUIVALENT. 12" MIN REMOVABLE COVER -7 - - 2. INVERT ELEVATIONS OF ALL -- OUTLET PIPES MUST BE EQUAL. • • •< ri_ a K. - _. _ J. THE SLOPE OF OUTLET PIPES BETWEEN THE DISTRIBUTION BOX • •: AND THE DISTRIBUTOR LATERALS •�. • SHOULD BE I/8" PER FOOT. BAFFLE -. INVERT INLET 2 --MIN ELEV. O O CONTRACTOR TO USE SPEED LEVELERS OUTLET AS SUPPLIED BY FORT MILLER TO L110 EQUALIZE FLOW ;• /"-5" __ - .' - a • - • tea• .•- - - 12" MIN CL EA N SA ND OR PEA GRA VEL #1 DISTRIBUTION BOX V INU I I U NEW YORK STATE Falls D EP Rtr M N 8E HEAL 7ii ��++�/CC n r� Refer to first sheet for approved date and signature, SHEET T L �F SA NI TA R Y E TA IL S ICOR LOT 84 ALPHINE AVENUE HOMESTEAD VILLAGE TO WN OF QUEENSBUR Y WARREN COUNTY, NEW YORK SCALE: 1 " = 20' AUGUST 15, 2006 ENVIRONMENTAL DESIGN PARTNERSHIP, LL 900 ROUTE 146 CLIFTON PARK, N.Y. 12065 (516) 371-7621 ENGINEERING LANDSCAPE ARCHITECTURE LAN® SURVEYING JAMES E. MITCHELL P. E. 553,337 X