2006-687 ` TOWN OF QUEENSBURY 742 Ba Road Queensbury,NY 12804-5902 (518)761-8201 ��� Y �Q �Y, Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20060687 Date Issued: Tuesday, November 27, 2007 This is to certify that work requested to be done as shown by Permit Number P20060687 has been completed. Location: 550 CORINTH Rd Tax Map Number: 523400-308-018-0002-014-002-0000 Owner: E. WADE & CAROL RUSSELL Applicant: E. WADE & CAROL RUSSELL This structure may be occupied as a: Residential Addition By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the r � property owner of the responsibility for compliance with Site Plan, ` G Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20060687 Application Number. A20060687 Tax Map No: 523400-308-018-0002-014-002-0000 Permission is hereby granted to: E. WADE & CAROL RUSSELL For property located at: 550 CORINTH Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: E. WADE & CAROL RUSSELL 550 CORINTH Rd Residential Addition $19,500.00 QUEENSBURY, NY 12804-0000 Total Value $19,500.00 Contractor or Builder's Name/Address Electrical Inspection Agency PLINEY TUCKER 41 DIVISION Rd QUEENSBURY, NY 12804-0000 Plans &Specifications 2006-687 450 SQ FT ADDITION $75.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Tuesday, October 23, 2007 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To of ensb Mull : October 23, 2006 SIGNED BY `�f for the Town of Queensbury. Director of Building&Code Enforcement OFFICE USE_ONLY TAX MAP NO. /F- - �I PERMIT NO. lJ�% �, Date FEES: PERMIT 7. RECREATION OCT, 0 3 2006 ---_ENGINEERING (If applicable) ' ' � PRINCIPAL S TR UCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: -ZZf'y- j , OWNER: Gc.9 tet( S s ADDRESS:f / lel 1// S roADDRESS: ,� fes�ta/G/,!c'NS;6�i v �56 c,�v.,j; / d PHONE NOS. 7 •/ PHONE NOS._ ��,/ - ,vim CONTACT PERSON FOR BUILDING &CODES COMPLIANCE:' //ivz % r HONE: jr6. 7/ LOCATION OF PROPERTY: .S–a , .7h I I SUBDIVISION NAME: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT Z APPLY TO YOUR Z 1Y Ga PROJECT O o 0O • „, } a � � „ � w a = = Z ¢ Q '- U) Nco o � 1°— aim SINGLE FAMILY -- / d N/A )J 4 )/5 7 TWO-FAMILY MULTI-FAMILY (NO.of UNITS ) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST: /GJ.. p FUEL TYPE: HEAT TYPE: *HOW MANY FIREPLACE(S): AND/OR WOODSTOVES(S): ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? IS THIS A HISTORIC SITE? /l/%, PROPOSED USE OF BUILDING OR ADDITION: ,y I /Li 'Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office B 3-LGL 11-05 Town of Queensbury• Community Development Office • 742 Bay Road, Queensbury, NY 12804 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above. Signed Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: :UI •1Nt &CODES APPRo ZONING APPROVAL '‘o "-7 DAT' DATE QUESTIONS? CALL 761.8256 OR EMAIL codes(c queensbury,net VISIT OUR WEBSITE FOR MORE INFORMATION www.queensbury.net T own of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 CIA-•-kft; Queensbury Building & Code Enforcement - Resi s- •11 Final Inspection Office No. (518)761-8256 Arrive: n: �►: te•.art. l7- 0... Date Inspection request received: Inspector's Initials: (.-RNAME: k2 SSe-11 •.' IT#: mrd LOCATION: 55-0 6)ri poi g %ATE: — TYPE OF STRUCTURE: _ A •7 -- -� w!' . Comments Yes NoN/A I0/z3/0:7 Building Number/Address visible from road _ p Chimney Height/"B"Vent/Direct Vent Location f Fresh Air Intake —~ 3 inch Plumbing Vent through roof minimum 6 inches ke-ler �� ���1/v;��Roof Complete/Exterior Finish Complete Platform at all exterior doors � Guards at stairs, decks,patios more than 30 inches above grade 2 ,,0711 �� �• Guard at stairwell at 34 inches or more l Guard at deck,porches 36 inches or more Q)� // '`/ /0—7 Handrail Termination at Newell Post or Wall / Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers called Grade away from foundation 6 inches with 10 feet ph.7 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade ) cks Interior privacy/trim/doors/main entrance 36 inches I 1�� 1 �Ie e- �" Bathroom/Kitchen watertight ?"! Safety glazing/Window in stairwells safety glazing 2� D �'� Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq. ft. vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'/s"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System./Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0[Temporary/Permanent 1 L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc Queensbury Building & Code Enforcement - Res' ntia al Inspection of .No.(518)761-8256 Arrive: , //. O 9 rt: - Pm received: VIO/0 Date Inspection request 7 Inspector's Init . �J NAME: PE 1 IT#f: Q LOCATION: 0 �5v '.1 D , E: G TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road Chimney Height/'B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches p Q Roof Complete/Exterior Finish Complete / 17 �- Platform at all exterior doors l � Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet J 6 inch clearance to sill plate _ J Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area / Crawl Spaces 18 inch x 24 inch access, 1 sq. ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum %2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Stie. Site Plan /Variance required Flood Plain Certification, if required Okay to issue C/C or C/0 [Temporary/ : rmanent_/ ✓ L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc —.—�-- ! M.ke,. q- �.ft!< Town of Queensbury Fire MarshalY 742 Ba Road � '�v � Queensbury,NY 12804 761-8205 I 761-8206 ,i fax 745-4437 Factory Built Gas Fireplace/Stove Inspection Report Notice: New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the installation Manual accompanying the appliance.No deviation from the manufacturer's / instructions or specifications is allowed. Permit# • Schedule Inspection ,67-4‘—i0--TTime ( I Di/'o‘..---6•7 am m anytime Inspector O'P Name RoS3 I I Address (SO ' r v i , Rough In Final Appliance Mufacturer__ © L Model# V c 3 Co Direct Vent Factory Built Chimney Flue Size Double Wall Triple Wall Insulated Yes No N/A Comments Floor Protection Clearances to Combustibles (all sides) Firestop(s) Vertical Chase Wall Penetration X .> Vent Clearances to Combustibles K Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible K . construction within 10 feet - .%)‹i Gas Shut-Off Valve Combustion Air Hearth Extension (if any) . (' Mantel Y ,,,, ,-. 't- Height above f/p opening _� T ,/ Witness Operation 1� Tank Placement(if LP) — ),( White—Banding Dept. Yellow-Cbeta ter Pink—Fire Marshal 00 —/� , © /i�/off ( 1 Rough P umbing / Insulatioli Inspection Report Office No. (518) 761-8256 Date Inspection requ- rece}� Queensbury Building & Code Enforcement Arrive: .. t. a , • r. /� D art: ,_ pp m 742 Bay Road, Queensbury, NY 12804 Inspector's Initial NAME: PERI;#: LOCATION: $757) ,51)- INSPECT ON: 9Lt-cam TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air Head "T-P.S. for minutes -77C' R-.idential Check Commercial Check - Insulation / I `� ��: ku_17 Proper V-• , Attic Vent \ Duct / Hot Water Piping Insulation e- If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: L:\Pam Whiting\Building&Codes\Inspection Fornu\Rough Plumbing Insulation Report.revis'ed Nov 17 2003.doc Revised February 15,2005 Z.---/ r /A.ik"G4. ._---./,-/ Framing/ Firestopping Inspection Repo 5---4_/, Office No. (518) 761-8256 Date Inspection reque, • .e, d: O Queensbury Building&Code Enforcement Arrive: '3't a . ; Pe. : 'h -) a 742 Bay Road, Queensbury,NY 12804 Inspector's Initial AIA NAME: .; 7 'k ?r PERMIT#: ,- — LOCATION: 'W ( 9f ,__)1 C_ INSPECT ON: Filc, TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Attic A 2"x 30"minimum Jack Studs/Headers f/ Bracing/Bridging 1 Joist hangers / Jack Posts/Main Beams // Exterior sheeting nailed properly J 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2,3 hour li Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall !_ Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade _ __ 2 kkd d 5/27a7 Foundation Inspe tion Report Office No. (518)761-8256 Date Inspection re,ues - ' •: Queensbury Building&Code Enforcement Arrive: ' :OL Depart: arni6-19 742 Bay Rd.,Queensbury,NY 12804 Inspectors Initia T#: t/ LOCATION: ,(9/1 • '‘SSPECT ON: i. TYPE OF STRUCTURE: Comments N N/A gs Pi c6tV 0pf�`e•1U1 1,46-` 11140 onolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM ?/07- Framing/ Firestopping Inspection R port Office No.(518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p De art:/64A am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: ) NAME: vS / PERMIT#: O LOCATION: pT i�/l j�1� INSPECT ON: TYPE OF STRUCTURE: Y N NIA COMMENTS Framing Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z(w) 16 gauge(8) 16D nails each side Draft sto.i i: 000 sq. ft. floor trusses hor Bolts 6 ft. or •ss on center I fz34L, Ice and water shield 24 inches from wall ire se'aration , 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing/ Firestopping Inspection Report Office No.(518) 761-8256 Date Ins.ection requ; ', • Ad.Ili Queensbury Building&Code Enforcement Arrive:4" - •ro r /0;,.. : glai-r.• 742 Bay Road,Queensbury,NY 12804 Inspector s Ini . NAME: R o hi)E Ll-_ PERMIT#: Q(0—(0067 LOCATION: ,575—C C.C??t t,,1 T VA 2) INSPECT ON: 1i—k$—tom( TYPE OF STRUCTURE: Y N 1 N/A COMMENTS Framing Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall / ., Fire separation 1,2,3 hour `� �\ � Fire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Foundation Inspection Report Office No. (518) 761-8256 Date Ins.'ection ref .est rec- a-. i' Queensbury Building&Code Enforcement Arrive: •epart: ,; . y, 742 Bay Rd.,Queensbury,NY 12804 Inspector's Init ,f, NAME: R1 ,')E UV. PERMIT#: (T -(.`S( LOCATION: �.5�5C CC R OT 1 ( 0 INSPECT ON: 1 - —LAD TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab l-C�D� h" T t1\ Reinforcement in Place (JC\b--` ��� 1, The contractor is responsible for providing protection from freezing By x,15 CAL-\ for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place NO/(//Footing Dowels or Keyway in place I Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width j 6 inches above footing 4/ 6 mil poly for wet areas under slab / Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No. (518) 761-8256 Date Inspection re e' ed: Queensbury Building &Code Enforcement Arrive: 2,: Depart: Z0 anpm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initia f " NAME: v��EL_L PE'' IT#: O� 47 LOCATION: rp (` nit i -� P Dprp ) SPECT ON: 1�_z-7-- TYPE OF STRUC . Comments I' N ' N/A Footings Piers T _ I Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. _ Foundation/Wallpour t3c�oc� Reinforcement in Place .o5 Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/ Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab _^v� Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.Inspcction.FORMSWoundation Inspection Report.doc January 28,2003 (75,-poo) / R/b/V ///r-2-2/C9C Foundation Inspection Report Office No. (S 18) 761-8256 Date Ins.-ction ' est rec-•,ed: -,, Queensbury Building&Code Enforcement Arrive: - - . ,h:�. Depart: j 93/11(in 742 Bay Rd.,Queensbury,NY 12804 Inspector's Ini . _ `— lr NAME: RMIT#: $ -45-7 LOCATION: 4 O C_pr,' 4_ INSPECT ON: 11 2_4 .- C U) TYPE OF STRUCTURE: Comments Y‘,/ N N/A Footings Piers Monolithic Slab em orcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM