Loading...
2011-047 TOWN OF QUEENSBURY F.41p:0 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building& Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20110047 Date Issued: Wednesday, March 21, 2012 This is to certify that work requested to be done as shown by Permit Number P20110047 has been completed. Location: 319 CORINTH Rd Tax Map Number: 523400-308-016-0002-004-000-0000 Owner: NDC REALTY, LLC Applicant: GREEN MOUNTAIN SUPPLY This structure may be occupied as a: Commercial Alteration By Order of Town Board TO OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the propertyit 1 owner of the responsibility for compliance with Site Plan,Variance,or P ty P other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. Temporary Certificate of Occupancy 90 Day Building Permit No. : 2011-047 Property Location : 319 Corinth Rd Approved for the following uses: Commercial Alteration Conditions of approval : I) install handicap& no parking signs as per approved site plan 2) complete all site items as per approved site plan 3) remove thumb latch on main entry doors &replace w/push paddle or lever 4) need to bond flex gas pipe back to main ground 5)handicapped parking& signage as per site plan 6) complete sitework as per approved site plan $200 fee received on: September 26t 2011 90 Day Temporary CO expires on: November 6t 2011 *A final inspection for this project must be scheduled before the expiration of this Temporary Certificate of Occupancy—if your project is not complete within this 90 day period you w' 1 be subject to additional fees* Signature of Appli .►'t: � pp Director of Building& Codes: \ TOWN OF QUEENSBURY F. .4y 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20110047 Application Number. A20110047 Tax Map No: 523400-308-016-0002-004-000-0000 Permission is hereby granted to: NDC REALTY, LLC For property located at: 319 CORINTH Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: NDC REALTY, LLC 402 E MAC EWEN Dr Commercial Alteration $8,000.00 OSPREY, FL 34229-0000 Total Value $8,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2011-047 1100 sq ft commercial alteration- Green Mountain Supply $220.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Thursday, March 08,2012 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town orensby ', �f T,fies4ayalarch 08, 2011 SIGNED BY "VJJ-%'y4; for the Town of Queensbury. Director of Building&Code Enforcement 4- r r.' s""7010 '� OFFICE USE ONLY -3G5" . iL-2-- -- --��.. TAX MAP NO. PERMIT NO. li Cl/7 L� ;r LE 7 -, t_ ' --- -7,ii.) FEES: PERMIT62201- RECREATION ENGINEERING ' 11) (If applicable) • ' ; FEB 2 6 1,91 Y PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT I A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICAN BUILDER: Kur--+ Lct€V OWNER: G4,�}V1 3 (2c, / ( eiseje ADDRESS: 945Z U 5 YIL-- S 5+.E. G- ADDRESS: 5C15Z U 5 • S 51�,Cr- Orly, PHONE NOS. 02-'673 J C-27 PHONE NOS. 0.62-3-5\-( ` 7?L 3 CONTACT PERSON FOR BUILDING& CODES COMPLIANCE: Ku.' - 1-LL-v-- PHONE: X02`C73 —6)�� LOCATION OF PROPERTY: �7 6+'}Y-1 HAS THERE BEEN A SITE PLAN REVIEW;VARIANCE OR SUBDIVISION APPROVAL? DSS ❑ NO IF SO, INDICATE APPLICATION NO.AND DATE OF APPROVAL: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT p e. p H APPLY TO YOUR z w LL w PROJECT O O = IT Ou _ < OAUu ��N1-z < < � U) OI u CC SINGLE FAMILY TWO-FAMILY MULTI-FAMILY (NO.of UNITS ) TOWNHOUSE BUSINESS OFFICE '� 1 I ) U O RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER Town of Queensbury* Community Development Office * 742 Bay Road, Queensbury NY 12804 Revised 4/14/2010 IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: G l V.`5 I -by ESTIMATED CONSTRUCTION COST: ` G UCS FUEL TYPE: AIct• HEAT TYPE:)-uvu2d 1)01 rHOW MANY FIREPLACE(S):)( f/i4 AND/OR WOODSTOVES(S): /v ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? Ai 0 IS THIS A HISTORIC SITE? V 0 PROPOSED USE OF BUILDING OR ADDITION: QC-C) - -)Pc(--C ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? *Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree tot bove. Signed Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Town of Queensbury* Community Development Office * 742 Bay Road, Queensbury NY 12804 Revised 4/14/2010 Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: BUILDING & CODES APPROVAL ZONING APPROVAL DATE DATE QUESTIONS? CALL 761-8256 OR EMAIL codes(�queensbury.net Office Use Only VISIT OUR WEBSrrE FOR MORE INFORMATION www.queensbury.net Operating Permit Issued: Yes No Occupancy Type: Construction Classification: Assembly Occupancy Limit: Special Conditions: Town of Queensbury* Community Development Office * 742 Bay Road, Queensbury NY 12804 S*ctus �s Commercial Final Inspection/Report Office No.: (518)761-8256 Date Inspection =-j •=iced: QueensburyBuilding&Code Enforcement Arrive: "- lei,7,-7,i0De rt:742 Bay Road, Queensbury, NY 12804 Inspector's I r - NAME: i. Qrl-- PERMIT ". 1 /1-7" LOCATIO . TE: r — • 5wipokoercialCOMMENTS: .. Y N NA Chimney 1"B'Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish/Grade Complete 6°in 10'or Equivalent Interior 1 Exterior Guardrails 42 in.Platform I Decks Interior I Exterior Bailisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.–38 in./Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq.ft. All Doors 36 in.w/Lever Handles I Panic Hardware,if required Exits At Grade Or Platform 36(w)x 44'(I)/Canopy or Equiv. Gas Valve Shut-off Exposed&Repiator(181 Above Grade Floor Bathroom Watertight I Other Floors Okay Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/StoragelReceiving/Shlpping Room(2 hr.), 1 %doors > 10%> 1000 sq.ft. a/.Hour Corridor Doors&Closers Firewalls I Fire Separation,2 Hour,3 Hour Complete I Fire Dampers/Fire Doors Ceiling Fire Stopping,3,000 sq.ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24' Smoke Vents Or Fan,if required Elevator Operation and Signage/Shaft Sealed J�j Handicapped Bathroom Grab Bars I Sinks/Toilets �j Handicapped Bath/Parking Lot S gnage Public Toilet Room Handicapped Accessible 4 O Handicapped Service Counters,34 in.,Checkout 36" Handicapped Ramp I Handrails Continuous/12 in.Beyond 03oth sides] • Active Listleninj System and Signage Assembly Space Final Electrical/Flex Gas Piping Bonded Site Plan I Variance required Final Survey, New Structure/Flood Plain certification,if req. As-bunt Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway 4' Water Fountain or Cooler , Building Access All Sides by 20'I Driveable Surface 20'wide Okay To Issue Temp.or Permanent CIO Okay To Issue C/C L:\Building&Codes FomnslBuilding&CodesUnspection FormssCommerciaI Final Inspection Reportdoc Revised January 7,2008 Inspection Form ,01, Town of Queensbury Fire Marshal O Periodic Inspection Date: Time: 742 Bay Road,Queensbury NY 12804 o Re-Inspection 518 761 8206/518 761 8205 d _CO Inspection Permit#: i i 09 FirMarshals Representative MJ Palmer Business Name: a RLQ Location: 3 ,4 ( ani i,-(-1 T2c) �) GK Stillman Contact: Type of Inspection N/A Yes No EXITS: Exit Access FC 1014&FC1029 NOTES Exit Enclosure FC 1020&FC1029 Exit Discharge FC 1024&FC1029 Locks and latches FC1008& FC1029.2 Sign:Normal FC 1011 &FC1029 Sign:backup FC 1011.5.3&FC1029.7.5 AISLES: Main Aisle Width FC 1024/1025&FC1029.11 Secondary Aisle Width FC 1025&FC1029.11 i( / FIRE EXTINGUISHER: Hung FC 906 V S Inspection of extinguisher FC 906 '1 EVAC Plan EC TRUSS ID SIGNAGE FCC 50 505.3 � � / EMERGENCY LIGHTING: Interior FC 1006.3&FC1029.8 Exterior FC 1006.3 Clearance to Electrical FC 605.3 Electric Wiring Enclosed/Labeled FC 605.3.1 Combustibles in Equipment Rooms FC315,2.3 F.D.Signage- FC 510 No Smoking Signs FC 310.3 Storage FC 315.2 Compressed Gas FC 3003 Vehicle Impact Protection FC 312.1 Interior Finishes FC 803-804 Smoke Detectors FC 907 CO detectors FC 610 Clearance to Sprinkler/Ceiling FC 315.2.1 18" / 24" EVAC SIGNS IN Rooms FC 404.6(R1 &R2) Fuel Pump Warning Signs FC2205.6 Fuel Station Emer Procedures FC2204.3.5 Exterior Storage FC 315.3 REINSPECTION DUE APPROXIMATELY Vacant Buildings FC 311 21 DAYS SYSTEMS: FC 901.6 Insp OK NC DATE: OK NC Date Generator Annual DATE: OK NC Hood Installation Elevator Semi Annual FIRE ALARM Annual DATE: OK NC HVAC Shutdown Sprinkler System Annual Sprinkler FDCIkr)111/VA Br�llai ippadi C Kitchen Suppression Semi Annual I5s'Jetfei Fuel Island Suppression Semi AnnualC4 Hood Cleaning 3-6-Annual Knox Box:installed/checked FC506 f,- Operating Permit, if required will be issued after Completion of Inspection Fire Marshal (/ikr is Aefier-i . �r/? i Commercia FinalIns on Report Officio No.: (518)761-8256 Date Ins• =lion , c--- =F= =•: Queensbury Building&Code Enforcement Arrive: 6`c ,,A Depart: l�Z° 742 Bay Road,Queensbury, NY 12804 Inspector's Initis f , NAME: 6tins 1 00 4 .I PERM. /60 . LOCATION: 1 I7 or , I DATE: - COMMENTS: .. Y 1 "A -c--F_+\? c-csooli Chimney 1"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"I Roof Complete / p`o DR .-16 Al?‘ Exterior Finish I Grade Complete 6"in 10'or Equivalent VEF-- Interior l Exterior Guardrails 42 in.Platform I Decks Interior)Exterior Bakers 4 in.Spacing Platform/Decks 'r` rekt_- v\ )\CSC Stair Handrail 34 in.-38 in./Step Risers 7"1 Treads 11" Pf\M1 6\631D Vestibules For Exit doors>3000 sq.ft. X AU Doors 36 In.w/Lever Handles I Panic Hardware,If required PES P % b )( Exits At Grade Or Platform 36(w)x 44"SlWCanopp or Eguhr. cwt o Gas Valve Shut-off Exposed&Regulator tin Above Grade ��� � `� & XFloor Bathroom Watertight/Other Floors 1-T- tkb �� Q��� gE Relief Valve,Heat Trap I Water Temp.110 Degrees Maximum Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System _ bSTW.-4AV Fresh Nr Sueply for Occupancy/Ventilation Combustion • de-- ? -t41•\J '-mot* Low Water Shut Off For Boilers I L 16%. �,�� Gas Furnace Shut Off Wdhin 30 ft.or Within Line Of Site Oil Furnace Shut Off at Enhance to Furnace Area V-`1 QUOVj V cc StockroornIStorageIReceiving/ShIpping Room(2 hr.), 1 %doors � � � ���� > 10%>1000 sq.ft. .62_ 'A Hour Corridor Doors&Closers , i_ --Vr--- Firewalls I Fire Separation,2 Hour,3 Hour Complete I Fire Dampers/Fire Doors Ceiling Fine Stopping,3,000 sq.ft Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan,if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars I Sinks/Toilets Handicapped )Parking Lot Signage i / Public Toilet Room Handicapped Accessible �� Handicapped Service Counters,34 in., 36" '` t, ) 'cam A t Handicapped Ramp 1 Handrails Continuous/121n.Beyond[Both /z- • ��� CO' 4 sides NP 6 M e Listening System and Signage Assembly Space ��\I �� ° final Electrical/Flex Gas Piping Bonded l� X Site Plan 1 Variance required tt[ plc, � ) VIN044 Final Survey, New Structure/Flood Plain certMcation,if req. As-built Septic System Layout Required or On File _ 6 t 6.1% N27 Building Number or Tenant Address on Building or Driveway 4" Water Fountain or Cooler c) . — /7v-rE___ SZ3N Building . ---#0,-- by 20'/Drivels Surface 20'wide Okay To I Permanent CIO --- Ocie Okay To I - ' bff E si7,--14___. N7 1( -C2 Q g v\; L:lBuilding&Codes FormssBuild'mg&CodesVnspedion FonnslCommercial Final Inspection Report doc Revised January 7.20G8 SZ4 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICP CERTIFICATE - ELECTRICAL APPROVAL Permit No....j...I..............................Cert. N2 - 10972 Cut-in Card No..................................... I -A W 6 z 6 C_—7'/z 1(2 a Owner..........Gle ......./............... 11.. ............................................ Location..... . .........rl,. Installation Consisting of... ............................................................................................................................ ....................I.................. ................................. Jl** .................................................................................................................................................................................... InstalledBy...........................................................................................Lic.No................................................... The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of makifi-n's etions at any time, and if its rules are violated,the Company shall have the right to re this f e. Date.... ..................... INSPECTOR......... Member N.F.P.A.,I.A.E.I. a kr is kS 12-^ 6;49d1 Inspection )/o or Permit to ccupy Fire Marshal's Office Request Recd Permit No. I/— 10 4/ 7L Town of Queensbury 742 Bay Road ` Queensbury,NY 12804 Scheduled Inspection Date: ST- J/ / Time: i ‘14-S17/// Phone: (518) 761-8206 Business Name: 6l L et , fil0 V t, 1--,,. _t' �o+ a KaFax: (518) 745-4437 Location: 3✓? Cpr/ vL f� Type of Inspection N/A Yes No gt $ , coc-.0t EXITS: f Exit Access 1/ Exit Enclosure COMMENTS Exit Discharge !14 V ic:ri _ 14,152, __�G Oit- t � AISLES: � ��' �� Main Aisle Width L./ n � Y46i• 4-(Z-5 Secondary Aisle Width ✓ EXIT SIGNAGE Sign-normal L/ Sign-battery i/ EVAC signs in rooms a� TRUSS ID SIGNAGE i/ EMERGENCY LIGHTING 1/ FIRE EXTINGUISHER: Hung 4 Inspection of extinguisher f� FIRE ALARM SYSTEM ✓ Fan Shutdown l/---- Fire Sprinkler System (FDC) Fire Suppression-kitchen v' Fire Suppression-Gas Islan V ds(---- Generator ✓ Hood Installation V Elevator r/ Interior Finishes Y Storage ✓' Compressed Gas 1/ Clearance to Sprinklers V Clearance to Electrical t/ Electric Wiring Enclosed/labeled Combustible Waste 1/' Vehicle Impact Protection ✓ _ ` -" Qom,_ ,1St �.Q, Knox Box Oiler d�/1C F.D.Signage-Utility Rooms No Smoking Signs Maximum Occupancy Sign A., / Emergency Evacuation Plan ✓ ❑ pproved (If no other approvals apply,the B&C Office will issue the Certificate of Occupancy) Denied / call for Recheck ,/ Inspected • : I, A ' - l ' i L:\FireMarshal\FM Forms Masters\permitto occupyform.doc (4,fer iS heL-r . - /Z � P Commercial Fin Ins ction Report L? • Office No.: (518) 761-8256 Date Ins•:ction ly- ce' ed: Queensbury Building &Code Enforcement Arrive: ',. '' Depart: k2.; per ' 742 Bay Road, Queensbury, NY 12804 Inspector's Initis : NAME: - Iii . ' I fi\- PERMI; ;#: //_---0 7�- . LOCATION: /7 0r .y -. / ' DATE:' COMMENTS: Y N NA ---\---�.`.�V C tv Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete ,/ CAD . R Exterior Finish/Grade Complete 6" in 10'or Equivalent ` C----- _-V— Interior I Exterior Guardrails 42 in. Platform/Decks Interior I Exterior Ballisters 4 in. Spacing Platform I Decks 31-ALL V\-Ri0.0\C_Pi\-) Stair Handrail 34 in.-38 in. /Step Risers 7"/Treads 11" tO F7fn_ ,1 ib\6.)1D Vestibules For Exit doors > 3000 sq. ft. Zt QE� X All Doors 36 in. w/L.evsr Handles I Panic Hardware, if required t Nj (� off) 6\A-Z- )( \)( Exits At Grade Or Platform 36(w)x 44°(1)/Canopy or Equiv. /IZ L �a Gas Valve Shut-off Exposed &Regulator(18°)Above Grade _ C_C)-QL-TE �� 5`_�._. X Floor Bathroom Watertight I Other Floors Okay _ Relief Valve, Heat Trap/Water Temp. 110 Degrees Maximum ,�k'kAirm vk`-) Q � Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System jj\—e- ��(a@.� Fresh Air Supply for Occupancy I Ventilation Combustion — .-\-2.-\-2 Low Water Shut Off For Boilers / L t i : i �� � \V Gas Furnace Shut Off Within 30 ft. or Within Line Of Site L,• C Oil Furnace Shut Off at Entrance to Furnace Area --3, .r.v�� c; -172 4 Stockroom/Storage/Receiving/Shipping Room (2 hr.), 1 %doors > 10% > 1000 sq. ft. \ R. 7 _. - '/<Hour Corridor Doors&Closers I -- \,--�-- Firewalls I Fire Separation, 2 Hour, 3 Hour Complete I Fire Dampers/Fire Doors , _ Ceiling Fire Stopping, 3,000 sq. ft.Wood Frame Attic Access 30°x 20"x 30" (h), Crawl Space Access 18" x 24" _ Smoke Vents Or Fan, if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars I Sinks I Toilets / Handicapped/Parking Lot Signage i V Public Toilet Room Handicapped Accessible to"� Handicapped Service Counters, 34 in., Checkout 36" LIQ v � n;,I `t Handicapped Ramp I Handrails Continuous/12 in. Beyond [Both I �, .1'� sides] ///7 F1,G - `` t' active Listening System and Signage Assembly Space SN''" (pQG.X ° Final Electrical/Flex Gas Piping Bonded t SSite Plan/Variance required — Qt w N0>,,•c, Final Survey, New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File / t �� L7 Building Number or Tenant Address on Building or Driveway 4' Water Fountain or Cooler 12X TC---- \A BuildingrSid by 20'/Driveable Surface 20'wide OkayTo lss a Tem r Permanent CIO -- C_-t;tk.V- Okay To Iss 6\ ‘1•7 _Q_ 3 .7Q Q___- ,, /5\T L:\Building&Codes Forms\Building&Codes\Inspection Forms\Commercial Final Inspection Report.doc Revised January 7,2008 2=// 72 / �,\ Commercial Final Inspection Rely Office No.: (518) 761-8256 Date Ins• :ction = , : =•: Queensbury Building&Code Enforcement Arrive: �r"i: , , Depart: ii'i . • 742 Bay R Queensbury, NY 12804 Inspector's In' : s: ..46_ NAME: PERMITf 644 S --0 LOCATION: 317 Car,"-'-f L DATE: - -1 COMMENTS: Y , N NA Chimney I'B'Vent/Direct Vent Location Plumbing Vent Through Roof 6°/Roof Complete — ckS? .-ce_ V-% --E_ Exterior Finish/Grade Complete 6°in 10'or Equivalent Interior 1 Exterior Guardrails 42 in.Platform/Decks NIAV-1 �L7 \-( Interior 1 Exterior Batlistlers 4 in.Spacing Platform 1 Decks Stair Handrail 34 in.-38 in.l Step Risers 7"I Treads 11" Vestibules For Exit doors>3000 sq.ft. / ' -- �J -C . VtsOkk____ All Doors 36 in.wlLvver Handles/Panic Hardware,if required . Exits At Grade Or Platform 36(w)x 44'(I)/Canopy or Equiv. L Gas Valve Shut-off Exposed&Regulator(18")Above Grade ./ Floor Bathroom Watertight!Other Floors Okay Relief Valve,Heat Trap I Water Temp.110 Degrees Maximum t% .‘ 'cta� Boiler!Furnace Enclosure 1 hr.or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion \1\-N3-47-7\--c)NaRr=___ Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site WE Oil Furnace Shut Off at Entrance to Furnace Area Stockroom /Storage/Receiving/Shipping Room(2 hr.), 1 'A doors , / F\�ti > > V 1096 1000 sq.ft. Hour Corridor Doors&Closers /".. ' Firewalls/Fire Separation,2 Hour,3 Hour Complete/Fire ‘69 44-4e _.t:s?_.. Dam•:m/Fire Doors �� Ceiling Fire Stopping,3,000 sq.ft.Wood Frame J Attic Access 30°x 20'x 30'(h),Crawl Space Access 18°x 24' Smoke Vents Or Fan,if required ` Elevator Operation and Signage/Shaft Seated "'r � � Handicapped Bathroom Grab Bars!Sinks/Toiletsil /z- cAmzAs_ Handicapped Bath I a �S,gI nae Public Toilet Room a icapped Accessible ,� Handicapped Service Counters,34 in.,Checkout 36" � -�J\c C���_ Handicapped Ramp I Handrails Continuous/12 in.Beyond[Bath C c- ���\ sides] ��� � `?� Active Listening System and Signage Assembly Space �j -2,- ,zi3c Final Electrical I Flex Gas Piping Bonded Site Plan 1 Variance required Final Survey, New Structure/Flood Plain certification,If req. �� As-built Septic System Layout Required or On File7 3 Building Number or Tenant Address on Building or Driveway 4' Water Fountain or ••.- Building Access • ; = • :^ by e/Driveable Surface 20'wide . / Okay To issue - • •r - :rmanent CIO Okay To 1 - = Cl - L:1Building&Codes FormssBuilding&CodesVnspection FormslCommenial Final Inspection Report doc Revised January 7,2008 6-:,-) - ---._a / -// / e' (d-i Inspection for Permit tcr Occupy Fire Marshal's Office Request Rec'd Permit No. /i.- o4' . Town of Queensbury 742 Bay Roadv '�S Queensbury,NY 12804 Scheduled Inspection Date: 5:31/ Time: / CJ Phone: (518)761-8206 Business Name: 6 • Fax: (518)745-4437 Location: 3 f ( ri h /-1 . 1201 Type of inspection N/A Yes No g,,,,ic,s, ®yL IW EXITS: a,.se K ‘Glioll /Merl Exit Access V. Exit Enclosure V COMMENTS Exit Discharge _ t/ AISLES: Main Aisle Width 1/' Secondary Aisle Width k/ EXIT SIGNAGE Sign-normal ✓' Sign-battery I� EVAC signs in rooms TRUSS ID SIGNAGE ✓, EMERGENCY LIGHTING V FIRE EXTINGUISHER: 5 6_) fi �/ � VI(r'o't_ Hung / Inspection of extinguisher a/' ` � Fiezialefee-- FIRE ALARM SYSTEM � ,j�,� 4 Fan Shutdown v" �� Fire Sprinkler System (FDC) V R20 0;:pc lopf94 -72..... tirx, ok 6) i6c._. Fire Suppression kitchen Fire Suppression-Gas Wan ✓ AOS )4-Cri#07 Cly ' - Generator Hood Installation ✓/ Elevator ✓ /' 6/1171- fbiA/ � Interior Finishes (/ Storage Compressed Gas If c Clearance to Sprinklers 1./ r Clearance to ElectricalI 4-6 ? Electric Wiring Enclosed/LabeledI .'Combustible Waste i ' Vehicle Impact Protection Knox Box F.D.Signage-Utility Rooms 14 V No Smoking Signs i. Maximum Occupancy Sign /' �f/�G 6/�///, Pali Emergency Evacuation Plan O` Odo‘Nt)(pproved (If no other approvals apply,the B&C Office will issue the Certificate of Occupancy) Denied / call for Recheck Inspect- • By: `� �� L:\FireMarshal\FM Forms Masters\permitto occupyform.doc Rough Plumbing I Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request-re•-iv Queensbury Building & Code Enforcement Arrive: �=r;O a :• - : ?�-It) a p 742 Bay Road, Queensbury, NY 12804 Inspector's Initiairrr <— NAME: aflia .1 0 PERM T #: 1 V— k--\ LOCATION: g 1c1 C 1 T\-\ 7 INSPECT ON: + — 1L\ —11 TYPE OF STRUCTURE: Y N NIA Rough Plumbing I Nail Plates Plumbing Vent/Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet I change of direction _ Pressure Test Drain /Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes - Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15ad 50 P. kc ; Insulation / Residential Check/ Commercial Check ' Tyvek or Similar Exterior Seale - Proper Vent, Attic Vent �4� "2 - Door/Window Sealed (No Insulation) \ Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace _— Duct work sealed properly I No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, neviaed February 15, 2005, revised January 7, 2008 Framing I Firestopping Inspection Report Office No. (518)761-8258Date Inspection - • 4 e-gt Queensbury Building&Code Enforcement Arrive: = eZ��ZA77, 1.1 part: 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:el NAME: G c ( P .MIT#: --- LOCATION: 1"1 C.if; R r) I =PECT ON: la= -- TYPE OF STRUCTURE: .C.,Q3 ,311 . \y7- \, e__ F : NA_ COMMENTS: Framing c Attic Access 22"x 30'minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 8 ft. 8 in, Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate . 1 'A(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from.wall Fire separation 1, 2,3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side'A inch or 5/8 inch Type X Garage side 518 inch Type X • Celtinglwatl Windows Habitable Space 1 Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:1Bttiiding&Codes Forms-OLDIBttilding&Codeslnspectbn FonnsVFraming Firestopping Inspection Reportdoc Revised Januwy 7,2008