2011-147 TOWN OF QUEENSBURY
742 BayRoad,Queensbury,NY 12804-5902 (518)761-8201
Q r},
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20110147 Date Issued: Wednesday, August 10, 2011
This is to certify that work requested to be done as shown by Permit Number P20110147
has been completed.
Location: 9 BOSS Rd
Tax Map Number: 523400-316-009-0001-006-000-0000
Owner: PHILIP & WENDY ASHE
Applicant: PHILIP & WENDY ASHE
This structure may be occupied as a:
Garage Detached By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the >i
property owner of the responsibility for compliance with Site Plan, %
Variance, or other issues and conditions as a result of approvals by the
Director of Building&CoLEnfor ent
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
eliiih
` 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
r0
Community Development-Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: P20110147 Application Number: A20110147
Tax Map No: 523400-316-009-0001-006-000-0000
Permission is hereby granted to: PHILIP &WENDY ASHE
For property located at 9 BOSS Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: PHILIP &WENDY ASHE
9 BOSS Rd Garage Detached $6,000.00
QUEENSBURY,NY 12804-0000 Total Value $6,000.00
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans&Specifications
2011-147
672 sq ft detached-garage
$100.80 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,April 27,2012
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town of ueens )yed I • i . ;',,,April 27,2011
9.
SIGNED BYi- ,\ for the Town of Queensbury.
Director of Building&Code Enforcement
?"' OFFICE USE ONLY
IA MAP NU. PERMIT NO. / )
41
FEE PAID /OD BLDG. & CODES APPROVAL
ACCESSORY STRUCTURE BUILDING PERMIT APPLICATION
Use this application for any structure other than the Principal Structure (house) to include, but not limited to:
garage, shed, greenhouse, dock, deck, etc. Refer to Informational Brochure No. 3 entitled Accessory Structures-
Sheds/Fences.
A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS. APPLICATION IS SUBJECT TO REVIEW BEFORE
ISSUANCE OF A VALID PERMIT. NO INSPECTIONS WILL BE MADE UNTIL THE APPLICANT HAS RECEIVED
A VALID BUILDING PERMIT. �3 J
OWNER:PA41f �.V d AX44 t:. INSTALLER/BUILDER: 0 W1,- c
ADDRESS: ! �j p�,5 Ir Q b./• Al Y. /az go ADDRESS:
PHONE NOS. c S I ) 1-13 PHONE NOS.
LOCATION OF PROPERTY: ? led nips/.. my SUBDIVISION NAME:
LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: q f3p,s� Q io. . /Y.y
HAS THERE BEEN A SITE PLAN REVIEW;VARIANCE OR SUBDIVISION APPROVAL? 0 YES NO 34 /5-0o (G)
IF SO,INDICATE APPLICATION NO.AND DATE OF APPROVAL: J l
ESTIMATED COST OF CONSTRUCTION: ff$6 UODo_. ANY OTHER ACCESSORY STRUCTURES ON PROPERTY? Ye,S
IF YES,PLEASE LIST: 72,,0) ,O `<hb p
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE:P�://p /,5i�' PHONE: ? 6 1-61/1-13
PROPOSED CONSTRUCTION 1ST FLOOR / 2ND FLOOR TOTAL PROPOSED
SQ.FT. SQ. FT. SQ.FT. HEIGHT
— - — — — — FT.&IN.
OPEN PORCH
DECK
3 SEASON,COVERED OR ENCLOSED PORCH*
BOATHOUSE
BOATHOUSE WITH SUNDECK 1
DOCK
SHED
POLE BARN
DETACHED GARAGE(Na OF CARS: 01 ) 67,2
OTHER ACCESSORY STRUCTURE:
*CONSIDERED FLOOR AREA & MUST COMPLY WITH FAR [FLOOR AREA RATIO] REQUIREMENTS IF THE
STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE.
To the best of my knowledge, the statements contained in the application, together with the plans
and specifications submitted, are a true and complete statement of all proposed work to be done
on the described premises and that all provisions of the Building Codes, the Zoning Ordinance,
and all other laws pertaining to the proposed work shall be complied with, whether specified or
noted, and that such work is authorized by the owner. Further, it is understood that I/we shall
submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested
by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed
surveyor, drawn to scale, showing actual location of all new
construction.
QUESTIONS? CALL 761-8256 OR EMAIL
codes(&queensbury.net
I have read and agree to the above.
VISIT OUR WEBSITE FOR MORE INFORMATION
Dated: 1� www.queensbury.net
Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/pm al am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:cv,,(A
•
NAME: /+çL _ PERMIT#: / /I1
/
LOCATION: `� S�� 7 INSPECT ON: `3_
TYPE OF STRUCTURE: e__ _AA)--1.„/\,6,-6---
(
Framing / Y N COMMENTS:
//
` f_ •
cJ / Vim` off � Q(N '
Attic Access 22" x 30" minimum ffpert..3 r� ' j J
Jack Studs/ Headers deaSe . iISS L ek)C:'` ; 11 o
Bracing/Bridging l
Joist hangers `
Jack Posts/Main Beams S /����
Exterior sheeting nailed properly
12" O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing , z
Headroom 6 ft. 8 in.
Notches/ Holes/Bearing Walls
• r
Metal Strapping for Notches Top Plate
1 'A(w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side 'A inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/ Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above I below grade
5.0 sf grade
L:18uilding&Codes Forms-OLD\Building&Cod \inspection FormsiFraming Firestopping Inspection Report.doc Revised January 7,2008
Queensbury Building & Code Enforcement - Residential Final Inspection
def
Office No. (518)761-8256 Arrive: am/pm Depart: am/pm
Date Inspection request received: Inspector's Initials:
NAME: PERMIT#: 2.01A
LOCATION: <31. % DATE: '
TYPE OF STRUCTURE: 6,-,A41-sa•&°.
Comments:
Yes No NIA
4" Building Number Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 18 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation/Insulation Certification/Sticker on Panel
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum'/z"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C l C or C I 0[Temporary/Permanent]
L:1Building&Codes Forms\Building&Codesllnspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised
January 7,2008;Revised 6/26/08;Revised 12/22/10
Foundation Inspection Report
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: _am/pm Depart:/-� , - am/pm
64,44V)742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: 5�� PERMIT#: //1`7'
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Comment,
VN N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
/
Reinforcement in Place 1
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\BuikUng&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
a
nr
I a
LL
E5
pJ \.
d
�' nn
Y
4
h
st
z rl�
CO
ti
tA
p-� s
'�. �'~�-.`` •`' rr+t„L��S'd31pt't�-per.Ltty
V � X
p
h
U7
.S'=paP Q
a
co
Q o W 2 W
J
`'� Q