2011-201 _t TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20110201 Date Issued: Wednesday, May 18, 2011 This is.to certify that work requested to be done as shown by Permit Number P20110201 has been completed. Tax Map Number: 523400-252-000-0001-076-002-0000 Location: 1952 BAY Rd Owner: WILLIAM KELLY Applicant: WILLIAM KELLY This structure may be occupied as a: Septic Alteration Residential By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5002 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20110201 Application Number: A20110201 Tax Map No: 523400-252-000-0001-076-002-0000 Permission is hereby granted to: WILLIAM KELLY For property located at 1952 BAY Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: WILLIAM KELLY 18 FOX HOLLOW Dr Septic Alteration Residential BLOOMING GROVE,NY 10914-00( Total Value Contractor or Builder's Name/Address Electrical Inspection Agency IBS SEPTIC &DRAIN ATTN: IVAN BELL 2 LOWER WARREN St OUEENSBURY.NY 12804 Plans&Specifications 2011-201 SEPTIC PERMIT RESIDENTIAL $40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Sunday,May 13,2012 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To wn-<Queensy ry;� Friday,May 13,2011 SIGNED BY ( �¢/ /4' for the Town of Queensbury. f Director of Building t�x�C0 nforcement E C Ir Q V E . DRevised 4/14/2010 OFF E ONl_x J _ T L MAY 1 M PERMIT NO. PERMIT FEE ell TOWN-OF OF QUEENSB RY APPROVALS: ZONING TOWN CLERK BUILDING&CODE S APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT. A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. B j �� ^ OWNER: � ,(X t'C(l� �I 7 INSTALLER: ` l? �C 0 �7CGo^"6 'LSGr a -C N�ADDR SS: QG�/G r Gt c,"r ADDRESS: (1 PHONE NOS. — QO 0 V PHONE NOS. —icz/ `01 LOCATION OF INSTALLATION: RESIDENCE INFORMATION: NO.OF COMPUTATION YEAR BUILT X = TOTAL DAILY FLOW BEDROOMS Gallons er bedroom - GARBAGE GRI D 1980 or older X 150 = INSTALLED? _ 1981-1991 X 130 = SPA OR HOT T�f�/\ 1992-present X 110 = d INSTALLED? PARCEL INFORMATION: ✓ TOPOGRAPHY: FLAT ROLLI G_X STEEP L PE %SLOP ✓ SOIL NATURE: SAND LOAM CLAY OTHE ✓ GROUNDWATER: AT WHAT DEPTH? _ ✓ BEDROCK/IMPERVIOUS MATERIAL: AT WHAT DEPTH?A ✓ DOMESTIC WATER SUPLY: MUNICIPAL WELL(If well:water supply from any septic system absorption is/m ft) ✓ PERCOLATION TEST: RATE IS PER MIINUTE PER INCH[mpi] (Test to be com et by a licensed professional engineer or architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). TANK SIZE:wQ LGALLON(MIN.SIZE IS 1,000 GAL.)Add 250 gallons to the size of the septic tank for each garbage grinder,spa or whirlpool tub. SYSTEM TYPE: ABSORPTION FIELD(WITH NO.2 STONE) Total lengt ft. Each trench X 3'r ❑SEEPAGE PIT(S)(WITH NO.3 STONE) How many? Size? ❑ALTERNATIVE SYSTEM Bed or other type? N 4 AA ❑HOLDING TANK SYSTEM Total required capacity? Tank size? Number of tanks? NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW-LIST PROVIDED. For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury QUESTIONS? CALL 761-8256 OR EMAIL Sanitary Sewage Disposal Ordi nce, f codes(&Queensbury.net rYO l/ VISIT OUR WEBSITE FOR MORE INFORMATION Signature of Person Re's"Ip"oh9ible Date ` www.aueensburv.net Town of Queensbury* Community Development Office*742.Bay Road, Queensbury NY 12804 .4 Septic Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p m Depart: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT NO.: �c LOCATION: INSPECT ON: RECHECK: Comments and/or diagram Soil Type: Sand/ Loam/Clay Type of Water: Municipal Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Well Casing Len th 50'+/- Y N N/A 150'to well/regfted if NO Absorption F Id: Tothl length ft. Len th of each trench ft. e th of trdaches ft. Size of Stone v V— See a e Pits: Nu r Size: x Stone Size Piping 'ze Type Wilding to tank Tank to DiAtribution Box Distribution Box to Field Pit Opebing Sealed: Y End Ca Y N Inlet/Outlet Pi &BafFles Y N Manholes 12"or less bdApw grade Y_N _ rovide extension col r if Yes Y N Location Se ations Foundation t tank ft. Foundation to absor do ft. Separation of ft. Conforms as per Plot Plan Y N Engineer Report and As-Built _Y N ETU Maintenance Contract Y_N provided Location of System on Property: Fro ear Left Side Right Side Middle Front Middle Rear System U e S us: Approved Partial Approved and needs to be re-inspected, please call the Building&Codes Office Disapproved L:\Pam Whiting\2010\Building Codes Forms\Inspection Forms\Septic Inspection Report-03 2910.doc 1 ril o of o ci G Jr S � 1-tzZlt � d Septic Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart am/pm 742 Bay Rd., Qu s Y 12804 Inspector's Initials: �_ ` NAME: PERMIT NO.: .: C�✓ LOCATION: INSPECT ON: RECHECK: Comments and/or diagram Soil T Sa / LWI Clay Type of Water: Municipal Well Water Waterline separation distance ft. Well separation distance Other wells: ft. Well Casing Length 50'+/- Y N N/A 150'to well required if NO Absorption Field: Total length Length of each trench �L- ft. Depth of trenches Size of Stone{ Seepage Pits: Number L t- Size: Stone Size: Piping Size T C Building to tank L Tank to Distribution Box Distribution Box to Field Pit1.+'t_ Opening Sealed: N End Ca Y N Inlet/Outlet Pipes&'BafFles Y N Manholes 12"or less below grade _Y _ N [provide extension collar if Yes Y N Location I Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits y ft. Conforms as per Plot Plan >)'V Engineer Report and As-Built _Y N ETU Maintenance Contract _Y—N provided Location of System on Property: Front Rear Side Right Side Middle Front Middle Rear S stem Use Status: Approved Partial Approved and needs to be re-inspected, please call the Building&Codes Office Disapproved LAPam Whiting\2010uilding Codes Forms\Inspectlon Fomms\Septic Inspection Report_03 2910.doc 4"X4" WOOD POSTS L EXISTING PLOT PLAN NO SCALE 0 25 50 75 100 GRAPHIC SCALE TEST PIT INFORMATION TEST PIT INFORMATION TAKEN 21 APRIL 2011 BY ETHAN P. HALL — RUCINSKI HALL ARCHITECTURE WITNESS BY IVAN BELL — IBS SEPTIC if= 0-10" DARK BROWN LOAM SOIL 10-28" MEDIUM BROWN/RED GRAVEL SANDY 28-60" LIGHT BROWN MEDIUM SAND 60-72" GRAY SAND MEDIUM/COARSE MOTTLING 0 60" NO ROOT LINE NO WATER SEEPING 4" X 4" WOOD POSTS BENCH MARK RR SPIKE IN 18 PINE 346.15 AL .1\ O � 4"X4A\ WOOD POSTS 0 APPROXIMATE OU' OF IMPORTED SAP FILL FOR NEW TIL FIELD BED. NEW SEWAGE DISPOSAL TILE FIELD (6 LATERALS AT 25'-0") EXISTING TANK \ PERCOLATION TEST INFORMATION PERCOLATION TEST INFORMATION TAKEN 21 APRIL 2011 BY ETHAN P. HALL — RUCINSKI HALL ARCHITECTURE PT-1 PERFORMED IN THE TOP 12" OF SOIL DUE TO LOCATION OF GROUNDWATER LOCATED IN THE NORTHWEST CORNER OF THE PROPERTY 1st TEST 1 min. 40 sec. 2nd TEST 2 min. 10 sec. 3rd TEST 2 min. 20 sec. 4th TEST 2 min. 25 sec. 5th TEST 2 min. 30 sec. FOR SEWAGE DISPOSAL DESIGN USE 1-5 MIN. SOIL TOWN OF Q EEiNSBURY O BUILDING & CODES D PT. Reviewed B : a Date: 1\ -- a TOWN OF QUEENSBURY APPROXIMATE LOCATION BUILDING DEPARTMENT OF HOUSE Based on our limited examination, compliance with our comments shall not be construed as indicating the plans and spec'kation$ are in full compliance with the Building Codes of New York State. PROPOSED PLOT PLAN NO SCALE 0 25 50 75 100 GRAPHIC SCALE SEPTIC SYSTEM DESIGN DESIGN FLOW — EXISTING 4 BEDROOM HOUSE WTH NEW WATER SAVING FIXTURES AT 110 gpd PER BEDROOM - 440 gpd EXISTING SEPTIC TANK — 500 gal TANK TO BE REUSED FOR REBUILT SYSTEM ABSORPTION FIELD — 1 to 5 MIN. PERC. RATE — APPLICATION RATE 1.2 gal/day/sq. ft. — 440 gpd DIVIDED BY 1.2,gal/day/sq. ft. = 367 sq. ft. OF TRENCH REWD. AT 2' WIDTH PER LATERAL USE 6 LATERALS AT 35' = 420 sq. ft. OF APPUCAT10N AREA. 7MAY & CODES XF,T, ?Q70 No.1 DESCRIPTION L11AI REVISIONS LL Q 3 N z� U D_` U — W z FTT— � W .L ZUa U a=� 0 Q �z0 3 ....1 to goz N p V W 0 F ��R � oa �U i Us N LL 0W2§ �— rno as o�� mZ 616 = 5�z 2+: mN a_000 c-r- Za v �-a< c 20 ro- t '0'u x '0 0 Nv ooE wW toV) >LL-w WORK IS TO BE AS SHOWN & NOTED AND IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS, TRADE ASSOCIATION PUBLISHED RECOMMENDATIONS AND GENERALLY ACCEPTED LOCAL CONSTRUCTION INDUSTRY PRACTICES. 0 tq;; 00 0 Cd W z 0 0 z .� � � A v� Q P4 t C13F 0 V 1.-4� , W N CAD FILE NAME ACAD \IBS\OVITT\SEPTIC-PLAN SCALE AS NOTED DRAWN BY DRAWING TITLE SEWAGE DISPOSAL PLANS & CALCULATIONS DRAWING No. C-1 SEWAGE DISPOSAL SYSTEM NOTES APPROXIMATE FINISH GRADE s tO 3" MSLOPE LIQUID LEVEL IN. y 1140 PER FOOT SEPTIC TANK N�_ I INLET & OUTLET BY FORT MILLER OR BAFFLES EQUAL a X ova 000 a MINIMUM 2x WIDTH MAXIMUM 4x WIDTH RECOMMEND ALL ACCESS & CLEANOUT GMNGS BE RAISED TO C BELOW FINISH GRADE. o� 00 PROVIDE 3" SAND OR --�°WOO PEA GRAVEL UNDER TANK SEPTIC TANK DETAIL N.T.S. PER APPENDIX 75-A TANKS SHALL HAVE INLET AND OUTLET BAFFLES, SANITARY TEES OR OTHER DEVICES TO PREVENT THE PASSAGE OF FLOATING SOLIDS AND TO MINIMIZE DISTURBANCE OF SETTLED SLUDGE AND FLOATING SCUM BY SEWAGE ENTERING AND LEAVING THE TANK. OUTLET DESIGNS SUCH AS GAS DEFLECTION BAFFLES ARE STRONGLY RECOMMENDED IN ALL TANKS. INLET AND OUTLET BAFFLES SHALL EXTEND A MINIMUM OF 12 INCHES AND 14 INCHES RESPECTIVELY, BELOW THE LIQUID LEVEL IN TANKS WITH A LIQUID DEPTH OF LESS THAN 40 INCHES, AND 16 AND 18 INCHES RESPECTIVELY, IN TANKS WITH LIQUID DEPTH OF 40 INCHES OR GREATER. THE DISTANCE BETWEEN THE OUTLET BAFFLE AND THE OUTLET SHALL NOT EXCEED SIX INCHES. BAFFLES SHALL BE CONSTRUCTED OF A DURABLE MATERIAL NOT SUBJECT TO CORROSION, DECAY OR CRACKING. TO DIST. BOX MIN. SLOPE 1/8" PER FOOT FROM SEPTIC - TANK 1. ALL UNITS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEW YORK STATE DEPARTMENT OF HEALTH AND SHALL BE PRECAST CONCRETE AS MANUFACTURED BY FORT MILLER OR EQUIVALENT. 2. ALL STRUCTURES TO BE PLACED ON FIRM, COMPACT SAND OR GRAVEL FOUNDATION. WHEREVER EXISTING FOUNDATION CONDITIONS ARE UNSUITABLE, CRUSHED STONE SHALL BE PLACED AS NECESSARY TO ACHIEVE A STABLE FOUNDATION. 3. SEPTIC TANKS INSTALLED IN TRAFFIC AREAS SHALL BE EXTRA HEAVY CONSTRUCTION DESIGNED FOR H-20 WHEEL LOADING. -O" OVERFILL TO ALLOW FOR SETTLEMENT E:ka INLET BAFFLE 2'-0" o%RITH-�L 2" MAX. z c�°DD = .F DODO O O ��0 N 6'-0' N MAXIMUM SEASONAL HIGH GROUNDWATER ELEVATION _STANDARD ABSORPTION TRENCH SECTION N.T.S. 18" MAX.1-����IIII,„I 12" MIN. N_1_� a PEA — GRAVEL CONCRETE OR STONE MARKER ABOVE ALL BURIED COVERS RECOMMENDED. OVER ES #1 DISTRIBUTION BOX BY FORT MILLER OR EQUAL ALL OUTLET INVERTS TO BE SET AT EXACTLY THE SAME ELEVATION. (USE OF SPEED LEVELERS REQUIRED) DISTRIBUTION BOX N.T.S. 15% MAXIMUM CROSS SLOPE ON SLOPED SITES UNTREATED BUILDING PAPER, OR GEOTEXTIL.E. 4" PERFORATED LATERAL LABELED AS FULLY MEETING ASTM STANDARDS FOR USE IN SEPTIC SYSTEMS. 3/4" TO 1 1 /2" WASHED CRUSHED STONE (MAXIMUM DEPTH OF CRUSHED STONE SHALL NOT EXCEED 30") (THERE SHALL BE NO SUBSTITUTION OF TRENCH WITH LEACHING CHAMBERS UNLESS APPROVED BY NYS DOH) 6" MIN. . . . . . . . . . . • �Ii �i i 4" PERFORATED PVC LATERAL. SLOPE 1 /16"-1 /32" PER FT. NOTES: 1. END OF ALL DISTRIBUTOR PIPES MUST BE PLUGGED UNLESS INTERCONNECTED. 2. ALL LATERALS TO BE OF EQUAL LENGTH. STANDARD ABSORPTION TRENCH PROFILE N.T.S. THERE SHALL BE NO CHANGE ON THESE PLANS IN ADVANCE OF OR DURING CONSTRUCTION, WITHOUT PRIOR APPROVAL OF THE DESIGN PROFESSIONAL OR THE TOWN BUILDING INSPECTOR. DESIGN, CONSTRUCTION, MATERIAL STANDARDS AND INSPECTION REQUIREMENTS SHALL COMPLY WITH THE LATEST EDITION(S) OF THE NEW YORK STATE DEPARTMENT OF HEALTH WASTEWATER TREATMENT STANDARDS - INDIVIDUAL HOUSEHOLD SYSTEMS APPENDIX 75-A. SEPTIC TANK TO BE SET ON A LAYER OF COMPACTED PEA STONE OR WASHED GRAVEL SEPTIC TANK TO HAVE SCH 40 PVC "r AT INLET AND OUTLET. - INLET 12" BELOW FLOW LINE, 6" ABOVE FLOW LINE - OUTLET 14" BELOW FLOW LINE, 6" ABOVE FLOW LINE 3" AIR SPACE ABOVE "T" TO TOP OF TANK NO ROOF, FOOTING, FLOOR, COOLING WATER, BACKWASH DRAINS, ETC., SHALL BE CONNECTED TO THE SEWAGE SYSTEM. NO SUMP PUMP, CONDENSATE, WATER SOFTENER, SPAS, OR HOT TUBS SHALL BE DRAINED INTO THE SYSTEM. THERE SHALL BE NO CONSTRUCTION OF SEPTIC SYSTEMS WITHIN 100' OF A CLASSIFIED BODY OF WATER. HOUSE TO SEPTIC TANK: 4*0 PVC SCHEDULE 40 WITH TIGHT JOINTS, MINIMUM SLOPE 1/4" PER FOOT. SEPTIC TANK TO DISTRIBUTION BOX: 4"0 PVC SDR 26 WITH TIGHT JOINTS, MINIMUM PITCH 1/8" PER FOOT. SANITARY DISPOSAL FIELD: 4"d PERFORATED PLASTIC PIPE MAXIMUM SLOPE 1 /16" PER FOOT, CAP ALL ENDS. THE BEST DESIGNED AND INSTALLED SEPTIC SYSTEM WILL EVENTUALLY FAIL TO FUNCTION PROPERLY WITHOUT PERIODIC MAINTENANCE. INADEQUATE SEPTIC TANK MAINTENANCE CAN RESULT IN CLOGGING OF THE TANK AND SEWAGE BACKUP INTO THE HOME AND/OR SEWAGE OVERFLOW ONTO THE GROUND SURFACE. FAILURE TO PERIODICALLY CLEAN A SEPTIC TANK COMMONLY RESULTS IN CLOGGING OF SOIL SURROUNDING THE ABSORPTION FILED BY OVERFLOWING SOLIDS NOT REMOVED BY THE SEPTIC TANK. THIS DESIGN IS INTENDED TO PROVIDE SUBSURFACE SEWAGE DISPOSAL ONLY FOR THE LOT IT IS SHOWN ON. NO ADDITIONS INVOLVING LIVING OR SLEEPING AREAS MAY BE ADDED TO THIS BUILDING WITHOUT THE APPROVAL OF THE BOARD OF HEALTH, TOWN OF QUEENSBURY AND REDESIGN OF THE SUBSURFACE DISPOSAL SYSTEM. THE SEAL AND SIGNATURE ON THIS PLAN SPECIFICALLY EXCLUDES CERTIFICATION FOR FUTURE EXPANSION OR REPLACEMENT. DWELLING IS TO HAVE WATER SAVING FIXTURES, INCLUDING BUT NO LIMITED TO: LESS THAN 2 GPM SHOWER HEADS, LOW WATER USE TOILETS, SINK FLOW RESTRICTORS. OBSERVE WATER CONSERVATION PRACTICES. SEPTIC TANK SHALL BE INSPECTED ANNUALLY TO DETERMINE SCUM AND SLUDGE ACCUMULATION BY THE HOMEOWNER OR A QUALIFIED SEWAGE HAULER. THE AMOUNT OF BUILD-UP NOTED AT EACH INSPECTION SHOULD BE RECORDED AND MAINTAINED BY THE HOMEOWNER. THE TANK SHALL BE PUMPED WHENEVER THE BOTTOM OF THE SCUM LAYER IS WITHIN 3" OF THE BOTTOM OF THE OUTLET BAFFLE OR SANITARY "T". THE PUMP -OUT CLEARANCES ALSO APPLY TO ANY CHAMBER IN MULTI -COMPARTMENT TANKS OR TO TANKS IN SERIES. MOST TANKS SHOULD BE PUMPED OUT EVERY TWO TO THREE YEARS. WHEN SEPTIC TANK IS PUMPED, THE SEPTIC TANK, BAFFLES/TEES, HOUSE SEWER CONNECTION AND OUTLET SHALL BE INSPECTED. BAFFLES/TEES THAT HAVE DETERIORATED AND NO LONGER PERFORM AS DESIGNED SHALL BE REPLACED. CRACKED OR BROKEN LINES MUST BE REPAIRED OR REPLACED. ANY COMPANY EMPLOYED TO CLEAN AND SERVICE THE SEPTIC TANK MUST BE A DEC PERMITTED SEPTAGE HAULER. SEPTIC TANKS SHOULD NOT BE WASHED OR DISINFECTED AFTER BEING PUMPED OUT. SEPTIC TAN!' ADDITIVES SHALL NOT BE USED IN THE SEPTIC SYSTEM. ADDITIVES ARE UNNECESSARY FOR THE PROPER OPERATION OF DISPOSAL SYSTEMS AND MAY CAUSE THE SLUDGE AND SCUM IN THE SEPTIC TANK TO BE DISCHARGED INTO THE ABSORPTION FIELD, RESULTING IN PREMATURE FAILURE. DO NOT DISPOSE OF EXCESS GREASE OR FAT INTO THE SEPTIC SYSTEM. DO NOT POUR OR DUMP ABNORMAL AMOUNTS OF CLEANING CHEMICALS OR CLEANERS INTO SINKS OR TOILETS. WHENEVER SEPTIC TANKS ARE TO BE ABANDONED IN THE EVENT OF PUBLIC SEWERS ARE INSTALLED TO HANDLE HOUSEHOLD WASTES, THE TANKS SHOULD BE REMOVED OR PUMPED OUT AND FILLED WITH SOIL TO PREVENT FUTURE CAVE-IN. NO VEHICULAR TRAFFIC OR PARKING SHALL BE ALLOWED ON ANY PORTION OF THE ABSORPTION FIELD OR THE SEWAGE DISPOSAL SYSTEM. FINAL GRADE SHOULD BE GRADED SO AS TO DIVERT ANY RUN-OFF AWAY FROM THE ABSORPTION FIELD. GRADING NOTES BEFORE ANY CLEARING OR GRUBBING OF THE SITE IS INITIATED, AND DURING EARTHWORK PHASES, SEDIMENT TRAPS SHALL BE CONSTRUCTED IN ALL STORM SWALES AND DITCHES. AFTER EVERY STORM EACH SEDIMENT TRAP SHALL BE INSPECTED BY THE CONTRACTOR FOR FAILURES OR CLOGGING. ANY FAILURE OR CLOGGING SHALL BE IMMEDIATELY CORRECTED. ALL BARE -EARTH AREAS SHALL BE SEEDED AND MULCHED AS SOON AS IS REASON- ABLY POSSIBLE TO PREVENT EROSION. AND EVERY BARE -EARTH AREA SHALL BE SEEDED AND MULCHED BY OCTOBER 1 ST. TEMPORARY RAPIDLY GROWING COVER CROPS, SUCH AS RYE GRASS AND MILLET MAY BE USED FOR TEMPORARY SURFACE SMALL BENCHES AND TEMPORARY INTERCEPTOR DITCHES, INCORPORATING SEDIMENT TRAPS. SHALL BE CONSTRUCTED WHERE LONG SLOPES ARE STRIPPED OF COVER GRASSES. OR WHERE FILL AREAS ARE EXTENSIVE. NEW SWALES AND UNLINED DITCHES SHALL INCORPORATE MATTING OR NETTING OVER SEED AND MULCH WHEN THE INVERT SLOPE EXCEEDS 2X ALL SWALES AND UNLINED DITGIES SHALL. BE SEEDED WITH REED -CANARY GRASS FOR FOUR (4) FEET EITHER SIDE OF THE SWALE OR DITCH CENTERLINE, AT A RATE OF 25 POUNDS PER ACRE. AFTER JUNE. ALL SEEDING SHALL ALSO BE IMMEDIATELY MULCHED. @l 1�7 ► �• �Li ►1:: ► �► � `. ��► `!al ► Ill.► 1► 11 . FINAL GRADING SHALL BE DONE TO ACCOMPLISH POSITIVE DRAINAGE AWAY FROM WILDING AT 6" IN 10' MINIMUM SLOPE. No.1 DESCRIPTION I DATE REVISIONS r N a 3 D N cur F_ Hi V ==Z - W %it dr W Or zQ0 V <zi 2 o F Q woo 3Z J to `F� LV 00 p V wv� % o C •- V ` woa Or 'V �— } RAN L, rnt 0 ao owo o�� yZ Ts FD:k, go_ �_ ; C 0� �5z t a < Waao m o ZZ v'cFi znFn V o o v_r 0 o N `v oxo 0 P o a E ww corn >ULw WORK IS TO BE AS SHOWN & NOTED AND IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, TRADE ASSOCIATION PUBLISHED RECOMMENDATIONS AND GENERALLY ACCEPTED LOCAL CONSTRUCTION INDUSTRY PRACTICES. O o t•H 00 O .C.) cd A A a o 1:14 lb 4­j P� cl �W CIS 4u O ••I N CAD FILE NAME ACAD\IBS\0MTT\SEPTIC-PLAN SCALE AS NOTED DRAWN BY DRAWNG TITLE SEWAGE DISPOSAL DETAILS & NOTES DRAWING No. C-2