2011-565 TOWN OF QUEENSBURY
c�
742 BayRoad,Queensbury,NY 12804-5902 (518)761-8201
Q rY>
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20110565 Date Issued: Friday, March 13, 2015
This is to certify that work requested to be done as shown by Permit Number P20110565
has been completed.
Location: 20 FERRISS Dr
Tax Map Number: 523400-301-019-0001-066-000-0000
Owner: KEVIN & TINA KELLY
Applicant: KEVIN & TINA KELLY
This structure may be occupied as a:
Residential Addition By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the property /f „dit--
owner of the responsibility for compliance with Site Plan,Variance, or VVV
other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement
or Zoning Board of Appeals.
TOWN OF QUEENSBURY
AIlik 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
wi r*
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20110565 Application Number: A20110565
Tax Map No: 523400-301-019-0001-066-000-0000
Permission is hereby granted to: KEVIN&TINA KELLY
For property located at: 20 FERRISS Dr
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: KEVIN& TINA KELLY Residential Addition $13,000.00
20 FERRISS Dr Total Value
QUEENSBURY,NY 12804 $13,000.00
Contractor or Builder's Name /Address Electrical Inspection Agency
PAUL SOKOL
84 LAUREL Ln
OUEENSBURY,NY 12804
p_ c 2 4\j 1__ei jiy A L
Plans&Specifications
BP 2011-565
392 sq. ft. residential addition
$100.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday,November 16,2013
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town of Queexriud z sd /NLe er 16,2011
1
SIGNED BY >\ for the Town of Queensbury.
Director of Building&Code Enforcement
•
��` TOWN OF QUEENSBURY
FOO 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20110565 Application Number: A20110565
Tax Map No: 523400-301-019-0001-066-000-0000
Permission is hereby granted to: KEVIN&TINA KELLY
For property located at: 20 FERRISS Dr
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: KEVIN&TINA KELLY Residential Addition $13,000.00
20 FERRIS S Dr Total Value
QUEENSBURY,NY 12804 $13,000.00
Contractor or Builder's Name /Address Electrical Inspection Agency
PAUL SOKOL
84 LAUREL Ln
OUEENSBURY,NY 12804
Plans&Specifications
BP 2011-565
392 sq. ft. residential addition
$100.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,November 16, 2012
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town u sbury /We •s?•y,November 16,2011
SIGNED BY < G , 1 for the Town of Queensbury.
Director of Building&Co.e Enforcement
•
OFFICE USE ONLY
TAX MAP NO. L; PERMIT N0. I S in) FiC U V E
FEES: PERMI�� .�L',. l
Ili/RECREATION
ENGINEERING 11111 �( Z��f
(If applicabl •) ;
T'{3WN UE ENS
PRINCIPAL STRUCTU - : BUILDING& CODES
APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONS
REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION.APPLICATION IS SUBJECT TO
APPLICANT/BUILDER:
OWNER: <---1/4. 411.E.j.c
ADDRESS: :� �+�lEBF3� LA •
ADDRESS: 2_42.___ _
QQ I Q
PHONE NOS.��— p
PHONE NOS.
__ 8_ --_.-_
CONTACT PERSON FOR BUILDING & CODES COMPLIANCE: pkc
PHONEco � ;
LOCATION OF PROPERTY: I ris S DK/it-C-
HAS
THERE BEEN A SITE PLAN REVIEW; VARIANCE a R SUBDIVISION APP VAL?ZES 0 NO
IF SO, INDICATE APPLICATION NO. AND DATE OF APPROVAL: • '
.t
I I
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT z
LLI Li-
APPLY TO YOUR z 1 o o
PROJECT 0 ¢ p O C1
S. D 1.- u iow W n0. = =
Cl. 2 06
SINGLE FAMILY
___;33_& -
i Ce
TWO-FAMILY —
MULTI-FAMILY ____
(NO. of UNITS ) —
TOWNHOUSE
- 1
BUSINESS OFFICE
RETAIL- —
MERCANTILE
i
FACTORY OR
INDUSTRIAL
ATTACHED
GARAGE(1,2,3)
OTHER I
1
.
IF COMMERCIAL OR INDUSTRIAL- NAME OF BUSINES$•
ESTIMATED CONSTRUCTION COST: i I /"Y?/I T.,��. .._
B 3-LGL 11-05
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? I ()
ARE THERE EASEMENTS ON PROPERTY? N O
I acknowledge no construction activities shall be commenced prior to issuance of a valid
permit. I certify that the application, plans, and supporting materials are a true and
complete statement/description of the work proposed, that all work will be performed in
accordance with the NY State Building Codes, local building laws and ordinances, and in
conformance with local zoning regulations. I acknowledge that prior to occupying the
facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read an agree to the above.
Signed ati2 ,A
�
Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction
codes or septic systems)
Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process,
application requirements or to schedule an appointment)
Permission is hereby granted to the above This application / proposed action described
Applicant to erect or alter the building herein is found to be in accordance with the
described herein in accordance with said
Application: zoning Laws of the Town of Queensbury.
BUILDIN -& C.DE A-PROVAL
ZONING APPROVAL
DATE
DATE
QUESTIONS? CALL 761.8256 OR EMAIL
Office Use Onl codes net
VISIT OUR WEBSITE FOR MORE INFORMATION
Operating Permit Issuers• v .. _.____ _.
Queensbury Building & Code Enforcement - Residential Final Inspectio �n
Office No. (518) 761-8256 Arrive: am/pm art't - am/pm
Date Inspection request received: 13-1t7 --t) 4, Inspector's Initials:
NAME: PERMIT#: 4ll
LOCATION: a..0 c S DATE:
TYPE OF STRUCTURE: Toz t,�I 1_lF >, Commes:
Int Yes No N/A
4" Building Number Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 18 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs,decks,patios more than 30 inches abovelrade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch dearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors I main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Wi in stairwells safety glazing
Interior Smoke I_ •rs/Carbon Monoxide etectors
Every level: Every Bedroom:
Outside every bedroom rea:
Inter Connected: y Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access,1 sq.ft.-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation to floor I Sticker on Panel
Duct work sealed properly/Blower Door Test Certification
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum'/"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/'A hour fire door/door closer
Gas Logs in Sealed or Glass Enclosure
Final Electrical;Energy Savingst_ighr s
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/O[Temporary/Permanent]
L:\Building&Codes Forms1Building&Codes\Inspection Fonns\Residential Final Inspection Form revised_100405.doc;Revised
January 7,2008;Revised 6/26/08;Revised 12/22/10,Revised 04/13/11
lIgna l t--1, �.3
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518)761-8256 Arrive: am/pm Depart —I ) am/pm
Date Inspection request received: Inspector's Initials:
NAME: k,�vI�J�t",i I"IQi ' V PERMIT#: "' JAGS
LOCATION: 'O/ Far t1,5 3 Dr DATE:
TYPE OF STRUCTURE: R e s 4-4 d
Comments.
Yes No N/A
4" Building Number Address visible from road
Chimney Height/"B"Vent/Direct Vent Location 2-1(F) 111/(y/i a
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 18 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy I trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/CarbonMonoxide Detectors
*.....0
Every level: Every Bedroom:
utside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access,1 sq.ft.-150 sq.ft.vents , i c?C-4Q--E(*)
Bathroom Fans,if no window
Plumbing fixtures � %
Foundationninsulation to floor/Sticker on Panel
3C4-(Z/Vt/ --.—
Duct work sealed properly/Blower Door Test Certification
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum'"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Gas Logs in Sealed or Glass Enclosure
Final Electrical;Energy Saving Light Bulbs 50%
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/O[Temporary/Permanent] .0
L:1Building&Codes Forms1Building&Codes1Inspection Forrns\Residential Final Inspection Form_revised_100405.doc;Revised
January 7,2008;Revised 6/26/08;Revised 12/22/10,Revised 04/13/11
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/pm Depart: r2am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's lnitials7
NAME: PERMIT #: 2,,c3"--
LOCATION: cE--11-uc)c INSPECT ON: 7, t�
TYPE OF STRUCTURE: _ R -`› />111.
Y N N/A
R• ,h Plumbin. /Nail Plates
Plumbing Vent 1 Vents in Place �==
1 14 inch minimum Drain Size
Washi ! Machine Drain 2 inch minimum
Cleanout eve 100 feet/chan.a of direction
Pressure Test
Drain/Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/Head
50 P.S.I for 15 minutes
Insulation/Residential Check/Commercial Check
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed (No Insulation)
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS: ti --v-kti
sen
•
Rough Plumbing insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/ A Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: 'r.
NAME: d; PERMIT#: J� . c t=
LOCATION: '�L INSPECT ON:
TYPE OF STRUCTURE: f"5 t&r i)
Framing e — N COMMENTS:
Attic Access 22"x 30' minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wan 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above I below grade
5.0 sf grade
L:1Buiiding&Codes Forms-OLD1Buiiding&Codesllnspec tion Form &Framing Firestopping Inspection Report.doc Revised January 7,2008
Mile
POWER TO PERFORM.
MiTek Industries, Inc.
14515 North Outer Forty Drive
Suite 300
Chesterfield,MO 63017-5746
Re: 11-3994
The truss drawing(s)referenced below have been prepared by MiTek Industries,Inc.under my direct supervision
based on the parameters provided by Riverside Truss.
Pages or sheets covered by this seal: I18447544 thru I18447544
My license renewal date for the state of New York is January 31,2014.
Lumber design values are in accordance with ANSUTPI 1 section 6.3
These truss designs rely on lumber values established by others.
0:pF NEW Y
4 GAgC'4 Q,A
co 9
to 4, A
cc
Lli
m
N
0� �O 08 009
-r()PESSI°ii/
November 30,2011
Garcia,Juan
The seal on these drawings indicate acceptance of professional engineering responsibility solely for the
truss components shown. The suitability and use of this component for any particular building is the
responsibility of the building designer,per ANSI/TPI 1.
s
Job Truss Truss Type Qty i Ply
118447544
11-3994 T1 ATTIC 11 I 1 RK MILES SOKUL QUEENSBURY NY
Job Reference(optional)
RIVERSIDE TRUSS,RIPARIUS,NY 7.250 s Aug 25 2011 MiTek Industnes,Inc. Wed Nov 30 13:01:38 2011 Page 1
ID MAOPhrggWFsLsANSof_meuyJDBV-T_'?axingB61Z0112bR113EtF1MIZkesmz9RSFYyE_Th
10-} 5-1-2 1 10-4-4I 12-4-1 1 14-0-0 15-7-15 1 17-7-12 1 22-10-14 1 28-0-0
2 -10.
8.10-8 5 1-2 5-3-2 1-11-13 1-7-15 1-7-15 1-11-13 5-3-2 5-1-2 0-10-8
5x8 = Scale=1 56.0
7.00 12 8
3x9=
LI
3x9=
2x4 II 7 I r—• 9 2x4 II
6 19 10
4x12 2 2 15x4 II
20 , 21 4x12 C
511
2x4 `' '+ 2x4 i
• 4 12
4x8 2 • ' 4x8
3 1`13
14
91 TIS
4 LI lf14
8x10 18 17 16 8x10
4x4 = 5x8 4x4=
l 5-1-2 1 10-4-4 1 17-7-12 1 22-10-14 1 28-0-0 1
5-1.2 5-3-2 7-3-8 5-3-2 5-1-2
Plate Offsets(X,Y): (2:0-5-0,0-2-61,114:0-5-2,0-2-61
LOADING(psf) SPACING 2-0-0 CSI DEFL in (lac) I/deft L/d PLATES GRIP
TCLL 46.2 Plates Increase 1.15 TC 0.82 Vert(LL) -0.39 18 >854 360 MT20 197/144
(Ground Snow=60.0) Lumber Increase 1.15 BC 0.73 Vert(TL) -0.52 16-18 >652 240
TCDL 10.0 Rep Stress Incr YES WB 0.54 Horz(TL) 0.09 14 n/a n/a
BCLL 0.0 Code IRC2006/TP12002 (Matrix) Wind(LL) 0.09 2-18 >999 240 Weight:161 lb FT=20%
BCDL 10.0
LUMBER BRACING
TOP CHORD 2 X 6 SYP SS*Except* TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc puffins.
1-5,11-15:2 X 6 SPF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
BOT CHORD 2 X 6 SPF 1650F 1.5E JOINTS 1 Brace at Jt(s):19
WEBS 2 X 4 SPF Stud*Except' MiTek recommends that Stabilizers and required cross bracing be
7-9:2 X 4 SPF No.2 installed during truss erection,in accordance with Stabilizer
SLIDER Left 2 X 4 SPF Stud 2-10-7,Right 2 X 4 SPF Stud 2-10-7 Installation guide.
REACTIONS (Ib/size) 2=2382/0-5-8 (min.0-3-12),14=2382/0-5-8 (min.0-3-12)
Max Horz 2=-161(LC 5)
FORCES (Ib)-Max.Comp./Max,Ten.-All forces 250(Ib)or less except when shown.
TOP CHORD 2-3=-3620/0,3-4=-3461/0,4-5=-3094/0,5-20=-2885/0,6-20=-2871/0,6-7=-2367/0,,:;. c '
7-8=0/706,8-9=0/706,9-10=-2367/0,10-21=-2871/0,11-21=-2885/0,11-12=-3094/0,
12-13=-3461/0,13-14=-3620/0
BOT CHORD 2-18=0/2884,17-18=0/2480,16-17=0/2480,14-16=0/2884
WEBS 7-19=-3352/0,9-19=-3352/0,6-18=0/760,10-16=0/760,4-18=-661/139,12-16=-661/140,
8-19=0/259
NOTES
1)Wind:ASCE 7-05;90mph;TCDL=4.0psf;BCDL=4.0psf;h=20ft;Cat.II;Exp B;enclosed;MWFRS(low-rise);cantilever left and right
exposed;end vertical left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pg=60.0 psf(ground snow);Pf=46.2 psf(flat roof snow);Category II;Exp B;Partially Exp.;Ct=1.1
3)Unbalanced snow loads have been considered for this design.
4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 46.2 psf on overhangs ! O� N E to y
non-concurrent with other live loads. C� pY
5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6)Ceiling dead load(5.0 psf)on member(s).6-7,9-10,7-19,9-19; Wall dead load(5.0psf)on member(s).6-18,10-16 .<4` ,�JPI GARC/q�*9
7)Bottom chord live load(40.0 psf)and additional bottom chord dead load(5.0 psf)applied only to room.16-18 ,...,'<i*'
j f-
8)This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced y� *
standardANSI/TPI1. �� ,f;,1-
9)Attic room checked for L/360 deflection.
n ,,, c LL
U1
LOAD CASE(S) Standard I- f, r,,,u,, _+ Z•
%- ESSlfl—
November 30,2011
o ,
®WARMIK Vrrifij NOTE OAT parameters and READ NOTOAT IIS AND PAW?DEO UMW REFERENCE PAGE MII-7473 ren. 10-`08 WORE USE Mit
Design valid for use only with Mitek connectors.This design is based only upon parameters shown,and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown
is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction it the responsibillity of the MiTek'
erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding eo»•x,.,e,00»..
fabrication,quality control,storage.delivery,erection and bracing,consult ANSI/TPII Quality Criteria,DjB.89 and BCSI Building Component 14515 N.Outer Forty,Suite#300
Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314,' ' ' Chesterfield,MO 63017
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/. Depart
742 Bay Road, Queensbury, NY 12804 inspector's Initials:
NAME: PERMIT#: L'>._
LOCATION: " —2._,2 V)'rc� INSPECT ON: �-�
TYPE OF STRUCTURE:
Y tia COMMENTS:
Framing
Attic Access 22"x30" minimum
Jack Studs/Headers ( ��
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in. vk 1==5c oc-5 L�C► - �%`-'�
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in. L 1: ,-c _
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 'A(w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or lesson center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed t
16 inch insulation in cavity min.
Garage Fire Separation
House side"A inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiiinglwail
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:1BuUding&Codes Forms-OLDDBuiding&CodesUtapedion FonnsTrarning Firestopping Inspedion Repo tdoc Revised January 7,2008
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/pm ; Depart: 14,s am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: PERMIT #:
LOCATION: 4, 7.-.0SS la INSPECT ON: Z\
TYPE OF STRUCTURE:
Y N N/A
Rough Plumbing /Nail Plates
Plumbing Vent/Vents in Place V
1 % inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/chane of direction
Pressure Test
Drain/Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/Head
50 P.S.I for 15 minutes
Insulation/Residential Check/Commercial Check V
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed (No Insulation!
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Rough Plumbing Insulation Reportrevised Nov 17 2003, revised February 15,2005, revised January 7,2008
Framing ! F'rest ppi g nspection eport
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: KPERMIT#: ' r
LOCATION: INSPECT ON: .C'_
TYPE OF STRUCTURE: _
Framing Y 1 jma COMMENTS:
Attic Access 22"x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in. •
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 6(w) 16 gauge(8) 160 nails each side
Draft stopping 1,000 sq. R. floor trusses
rpottitlicgats6 ft. or lesson center
Ice and water field 24 inches from wall
'on 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side'A inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space 1 Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:iBuIkling&Codes Forms-OLDrBufiding&CodesWapsction FoimslFreming Firestopping Inspection Repotdoc Revised Jemmy 7,2008
Fours � - /6 ---
dation Inspection Report
Office No.(518)761-8256 Date Inspection request received: r I
Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: ,Cc)
NAME: A PERMIT#: /_=S LS
LOCATION: LS S -A
- ' ' INSPECT ON: / �Sj�
TYPE OF STRUCTURE: ,,P/) W ' l
Con unentt
Y N TA
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump vt,/�
V
Footing Drain Stone:
12 inch width
6 inches above footing
1 for wet areas under slab
Backfill App
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/p Depart. m
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: �� /(V
PERMIT#:
LOCATION: �,. f'i 2,, lX . INSPECT ON: !2 -
TYPE OF STRUCTURE: ���y 14 )r)
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete
Materials,.: • se on site.
Foundati. + /Wallpour ‘77
Reinforcement in-PFace
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundatlon Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
(Iz:oo ) /O- Iz )P %cS 7 .
Foundation Inspection Report
Office No.(518)761-8256 Date Insction req r =
11
Queensbury Building&Code Enforcement Arrive: 11: : pm - .art: MI� ,��
742 Bay Rd.,Queensbury,NY 12804 Inspector's Inti= •
NAME: /ST L// j— PERMIT#:LOCATION: 20 Fer ri ss r INSPECT ON: — /
TYPE OF STRUCTURE: '
Comments
` g� Y N
ootings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site. _
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM