Loading...
2011-529 TOWN OF QUEENSBURY 742 BayRoad,Queensbury,NY 12804-5902 (518)761-8201 Q r3' ar► Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20110529 Date Issued: Thursday, September 13, 2012 This is to certify that work requested to be done as shown by Permit Number P20110529 has been completed. Tax Map Number: 523400-302-017-0001-055-000-0000 Location: 60 OLD FORGE Rd Owner: MICHAEL & LAURYL SMITH Applicant: MICHAEL & LAURYL SMITH This structure may be occupied as a: Deck By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the . property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY .411111hi Vro742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20110529 Application Number: A20110529 Tax Map No: 523400-302-017-0001-055-000-0000 Permission is hereby granted to: MICHAEL&LAURYL SMITH For property located at: 60 OLD FORGE Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: MICHAEL&LAURYL SMITH 60 OLD FORGE Rd Deck $800.00 QUEENSBURY,NY 12804 Total Value $800.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2011-529 ce /10/ ,, cu,--c/F9 216 sq ft deck $50.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday, October 31, 2012 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To ueensb ; 7 i n s •y,October 31,2011 SIGNED BY for the Town of Queensbury. Director of Building& ode forcement ` c)2 fl / - SE ONLY fTAX MAP NO. PERMIT NO. ...<;... .;. • _ FEE PAID 4 � s:LDG.&CODES APPROVAL MK t/ ; � 5 ACCESSORY STRUCTURE BUIL D ING PERMIT APPLICATION: Use this application for any structure other than the Principal Structure (house) to include, but not limited to: garage, shed, greenhouse, dock, deck, etc. Refer to Informational Brochure No. 3 entitled Accessory Structures- Sheds/Fences. • • • A PERMIT MUST BE OBTAINED BEFQRE WORK BEGINS. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. NO INSPECTIONS WILL BE MADE UNTIL THE APPLICANT HAS RECEIVED A VALID BUILDING PERMIT. / OWNER: 1 I i Cln�� INSTALLER/BUILDER: Ni d4 ADDRESS: 4,0 ©« f opt. 1)4-• ADDRESS: SA m PHONE NOS. `(gi-V -2 Eco I PHONE NOS. 578- rS 3-7 7.?4 LOCATION OF PROPERTY:6O Cid 67 ?-c? Qiic iuh,'a+/ SUBDIVISION NAME: LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: 3.461e HAS THERE BEEN A SITE PLAN REVIEW;VARIANCE OR SUBDIVISION APPROVAL? 0 YES I!1 NO IF SO,INDICATE APPLICATION NO.AND DATE OF APPROVAL: ESTIMATED COST OF CONSTRUCTION: $ 060 ANY OTHER ACCESSORY STRUCTURES ON PROPERTY? IF YES,PLEASE LIST: CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: PHONE: 1St ND PROPOSED PROPOSED CONSTRUCTION 1 FLOOR 2 FLOOR TOTAL HEIGHT SQ.FT. SQ.FT. )SQ.. T. FT.&IN. n OP�l �1 7 CO leeJ 1 a1(� v`I li S L DECKl*v 3 SEASON,COVERED OR ENCLOSED PORCH* BOATHOUSE • BOATHOUSE WITH SUNDECK DOCK SHED POLE BARN DETACHED GARAGE(NO.OF CARS: ) OTHER ACCESSORY STRUCTURE: *CONSIDERED FLOOR AREA & MUST COMPLY WITH FAR [FLOOR AREA RATIO].REQUIREMENTS IF THE STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE. To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with, whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed surveyor, drawn to scale, showing actual location of all new construction. QUESTIONS? CALL 761-8256 OR EMAIL rnrlae Thn.,aanahi,r,not Queensbury Building & Code Enforcement - Residential Final Inspection /a -1 c)-0( Office No. (518)761-8256 Arrive: am/pm Depart: /1",71m/pm Date Inspection request received: 6 t Inspector's Initials: /'Y &Li oZ0ll- Sa- NAME: PERMIT#: A LOCATION: Co o i'[ t' ( ,7C. (� DATE: ACM/ TYPE OF STRUCTURE: irv.,a- .�t', io Comments: ; ( , Yes No NIA 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake /,J►�S 3 inch Plumbing Vent through roof minimum 18 inches 1'/ (} !r• p" c: Roof Complete/Exterior Finish Complete (76 o vi Platform at all exterior doors }List(cam- i r. Handrail 4 or more risers C� Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more419 Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 8 inches with 10 feet � L --- 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches (ell-41N41/44X N,/ Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation to floor!Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical;Energy Saving Light Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O[Temporary/Permanent] L:\Building&Codes FormslBuilding&Codes\Inspection Fomrs1Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08; Revised 12/22/10,Revised 04/13/11