Loading...
2011-482 �_ TOWN OF QUEENSBURY IF04.43, 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20110482 Date Issued: Wednesday, October 26, 2011 This is to certify that work requested to be done as shown by Permit Number P20110482 has been completed. Tax Map Number: 523400-308-006-0001-004-000-0000 Location: 39 BURCH Rd Owner: JAMES VAN DORAN Applicant: JAMES VAN DORAN This structure may be occupied as a: Septic Alteration Residential By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the (4449 4 , . property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 FON Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: P20110482 Application Number: A20110482 Tax Map No: 523400-308-006-0001-004-000-0000 Permission is hereby granted to: JAMES VAN DORAN For property located at 39 BURCH Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: JAMES VAN DORAN BRENDA GRANGER Septic Alteration Residential 39 BURCH Rd Total Value QUEENSBURY,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency STONE INSTALLATIONS 232-6707 4305 STATE ROUTE 50 SARATOGA NY 12866-0000 Plans&Specifications 2011-482 septic alteration residential $40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday, September 28,2012 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T wn of ween lx�ryiv /Wednesday,September 28,2011 ffij SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement 0 '.' E Community Development Office Town of Queensbury • 742 Bay Road • Queensbury, New York •128(4 � � � �Q�� 'u SEP Office Use Only la 48'Z i�.}'��' 0 EN -BI_)F 1BUILDI �C &CODES / / , - TAX MAP NO. „(� / PERMIT NO. PERMIT FEE i�� APPROVALS: ZONING TOWN CLERK APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT: A PERM M .ST BE OBTAINED BEFORE WORK BEGINS.APPLIC TION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. OWNER: ..FG ., fr5 kr 4 e'a h INSTALLER: •yr t 4 _ / s / / ADDRESS: _ I i Air A . • /ADDRESS: n - C C . 0 CS c . , )ZUb6 PHONE NOS. PHONE NOS. — 70 LOCATION OF INSTALLATION: �S f CA l',../ IJ t L r+ s it Y y✓ W.1-.° ! Z Gl ° il RESIDENCE INFORMATION: YEAR BUILT NO. X COMPUTATION = TOTAL DAILY FLOW BEDROOMS (Gallons per bedroom) GARBAGE GRINDER 1980 or older X 150 = INSTALLED? /1 Q 1981 -1991 3 X 130 = y® SPA OR HOT TUB 1992-present X 110 = INSTALLED? r1 U PARCEL INFORMATION: ✓ TOPOGRAPHY: FLAT ROLLING • STEEP SLOPE %SLOPE ✓ SOIL NATURE: SAND /• LOAM CLAY OTHER ✓ GROUNDWATER: AT WHAT DEPTH? ✓ BEDROCK/IMPERVIOUS MATERIAL: AT WHAT DEPTH? ✓ DOMESTIC WATER SUPLY: MUNICIPALWELLWELL A (If well:water supply from any septic system absorption is:/00 ft) ✓ PERCOLATION TEST: RATE IS /i 1 i PER MIINUTE PER INCH[mpg (Test to be completed by a licensed professional engineer or architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). TANK SIZE: hl Cc) GALLON(MIN.SIZE IS 1,000 GAL.)Add 250 gallons to the size of the septic tank for each garbage grinder, spa or whirlpool tub. SYSTEM TYPE: / / � $ABSORPTION FIELD(WITH NO.2 STONE) Total length /6Y ft. Each trench X vi ❑SEEPAGE PIT(S)(WITH NO.3 STONE) How many? Size? ❑ALTERNATIVE SYSTEM Bed or other type? o HOLDING TANK SYSTEM Total required capacity? Tank size? Number of tanks? NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations with respect to this application and agree to abide these and all requirements of the Town of Queensbury QUESTIONS? CALL 761-8256 OR EMAIL Sanitary wa a Disposal Ordinance. codesccoueensburv.net Sig ur�e o atson Responsible /Date VISIT OUR WEBSITE FOR MORE INFORMATION www.oueensbury.net Septic Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: a Depart: am/pm 742 Bay Rd., Queens ury, NY 12804 Inspector's Initials: NAME: j� / 't�. •/ /` PERMIT NO.: LOCATION: /C INSPECT ON: 1—Z RECHECK: Comments and/or diagram Soil Type: Sand/ Loam/Clay Type of Water: Municipal/Well Water I- /�� Waterline separation distance ft. 0/ 71:0 / Well separation distance ft. Other wells: ft. 67e)7L 2 Well Casing Length 50' +/- Y N N/A [150'to well required if NO] Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field/ Pit Opening Sealed: Y N End Cap Y N Inlet/Outlet Pipes&Baffles Y N Manholes 12"or less below grade Y!.N [provide extension collar if Yes] Y—N Location/ Separations Foundation to tank ft. Foundation to absorption ft. k/'eUe-ti I/3 Separation of Pits ft. Conforms as per Plot Plan , Y -„_N Engineer Report and As-Built —Y—N ETU Maintenance Contract Y_N provided Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use,St, us: /y/_� Approved Partial Approved and needs to be re-inspected, please call the Building&Codes Office Disapproved L:\Pam Whiting\2010\Building Codes Forms\Inspectlon Forms\Septic Inspection Repori`03 29 10.doc TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 Inspections per Permit Permit# P20110482 Inspection Date Inspection Type Approved/Denied Comments Permit Type Person Responsible 09/22/2011 Miscellaneous Septic Alteration Residential JENNIFER HENDERSON Staff Misc 2011-482 permit received 09/26/2011 Miscellaneous Septic Alteration Residential JENNIFER HENDERSON Staff Misc 2011-482 permit entered 09/28/2011 Miscellaneous Septic Alteration Residential JENNIFER HENDERSON Staff Misc 2011-482 permit issued 10/12/2011 Septic Septic Alteration Residential CHARLES DYER Staff Partial 2011-482 provide engineer report 10/14/2011 Miscellaneous Septic Alteration Residential DAVID HATIN Staff Misc 2011-482 received engineer's inspection report Septic Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/ part: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: i)7t NAME: VA-114 °.74' i PERMIT NO.: LOCATION: rn INSPECT ON: RECHECK: Co ments and/or diagram Soil Type: Sand/ Loam/Clay Type of Water: Municipal/Well Water - r-e Ce!Uel /e f''- / ne-e r Waterline separation distance ft. l� Well separation distance ft. Other wells: ft. 1 Pt-Spec1/ 7 re'f O✓ Well Casing Length 50'+/- Y N N/A [150'to well required if NO] Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field/ Pit Opening Sealed: Y_N End Cap Y N Inlet/Outlet Pipes&Baffles Y_N Manholes 12"or less below grade Y_N [provide extension collar if Yes] Y_N Location/ Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan Y.,,N Engineer Report and As-Built Y—N ETU Maintenance Contract Y N provided Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Status: Approved Partial Approved and needs to be re-inspected, please call the Building&Codes Office Disapproved L:\Pam Whiting\2010\Building Codes Forms\Inspecdon Forms\Sepdc Inspection Report.03 29 10.doc hiecinesd7 s Septic Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Departr�� am/pm 742 Bay Rd., Queensb ry, NY 12804 Inspector's Initials: NAME: PERMIT .. l 4' ' a / LOCATION: 37 ``ivrd�. INSPECT ON: /0—/Z--// RECHECK: Comments and/or diagram Soil Type: _ % Loa Cla Type of Water: Municipal Well Waterline separation distance ft. Well separation distance S''c Other wells: ft. Well Casing Length 50' +/- Y N N/A [150'to well required if NO] Absorption Field: Total length 41L.OI4 ft. Length of each trench .6-1 ft. Depth of trenches 4eV•V ft. Size of Stone - 2 Seepage Pits: Number Size: Stone Size: Piping izee Type Building to tank *EEAA-AD Tank to Distribution Box tiQ3t) Distribution Box to Field/ Pit 11-30 ---� Opening Sealed: // N End Cap t/Y N Inlet/Outlet Pipes&Baffles _t—N nn 606vf `'K " v 0%- Manholes 12"or less below grade Y [provide extension collar if Yes] Y N'/A- Location/ Separations Foundation to tank i ft. Foundation to absorption 'b ft. Separation of Pits art. ft. Conforms as per Plot Plan Y b Engineer Report and As-Built —Y N ETU Maintenance Contract Y_ N provided Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear -m l S . . Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved L:\Pam Whiting\2010\Building Codes Forms\Inspectlon Forms\Septic Inspection Report_03 29 10.doc SEP'CIC SYSTEM GENERAL NOTES: 1. SEWAGE DISPOSAL SYSTEMS SHALL NOT BE INSTALLED IN WET OR FROZEN SOIL. 2. THERE SHALL BE NO VEHICULAR TRAFFIC OVER THE SEWAGE DISPOSAL SYSTEM. PRIOR TO CONSTRUCTION, THE AREA OF THE SYSTEM SHALL BE STAKED OUT AND FENCED OFF. 3. THE SANITARY DISPOSAL SYSTEM HAS BEEN DESIGNED IN GENERAL CONFORMANCE OF `APPENDIX 75-A, WASTE TREATMENT - INDIVIDUAL HOUSEHOLD SYSTEMS, NEW YORK STATE SANITARY CODE". 4. CELLAR, ROOF, AND FOOTING DRAINS SHALL NOT BE DISCHARGED INTO THE SEPTIC SYSTIM OR IN THE VICINITY OF THE ABSORPTION FIELD. 5. THE SEWAGE DISPOSAL SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE GARBAGE GI:;INDERS OR WATER SOFTENER BACKWASH. 6. HOUSE SEWERS ARE LAID ON FIRM FOUNDATION AT A MINIMUM GRADE OF ONE-QUARTER INCH PER FOOT PREFERABLY WITHOUT BENDS. AT LEAST ONE CLEANOUT WITH A PROPERLY FITTED PLUG IS TO BE PROVIDED. THE HOUSE SEWER SHALL ALLOW FOR VENTING OF GASES FROM THE SEWAGE SYSTEM. 7. HOUSE SEWER CONSTRUCTION INCLUDING MATERIALS SHALL COMPLY WITH THE APPLICABLE REQUIREMENT OF THE PLUMBING CODE OE NEW YORK STATE. 8. A MINIMUM HORIZONTAL SEPARATION OF 10 FEET SHOULD EXIST BETWEEN THE HOUSE SEWER AND ANY WATER LINE. WHERE LINES MUST CROSS, THE WATER SERVICE LINE SHALL BE AT LEAST 12 INCHES ABOVE THE HOUSE SEWER. IF A WATER LINE MUST PASS BELOW THE HOUSE SEWER, THE VERTICAL SEPARATION MUST BE AT LEAST 18 INCHES. 9. SUCTION WATERLINES SHALL NEVER CROSS UNDER HOUSE SEWERS OR ANY OTHER COMPONENT OF THE SEWAGE SYSTEM. 10. ANY CHANGE IN DIRECTION GREATER THAN 22.5° OF HOUSE SEWED PIPE WILL REQUIRE A CLEANOUT. 11. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION. NOTIFY ENGINEER OF ANY DISCREPANCIES. 12. CONTRACTOR TO FIELD LOCATE ALL EXISTING SEPTIC SYSTEM COMPONENTS PRIOR TO CONSTRUCTION FOR COORDINATION WITH NEW SYSTEM SPECIFIED. CONTRACTOR TO PUMP, REMOVE AND PROPERLY DISPOSE OF ALL EXISTING SEWAGE COMPONENTS NOT INDICATED TO REMAIN. 13. IT IS CONTRACTOR'S RESPONSIBILITY TO COORDINATE AND VERIFY ACCESS REQUIRED TO COMPLETE WORK SPECIFIED WITH OWNER PRIOR TO CONSTRUCTION. 14. ALL DISTURBED AREAS TO BE TOPSOILED, SEEDED, AND MULCHED AFTER BACKFILLING AND RE -GRADING. 15. CONTRACTOR TO LAY OUT ENTIRE SYSTEM TO VERIFY DEPTHS, INVERT ELEVATIONS, BOUNDARY LINES AND SETBACKS IN ACCORDANCE WITH PLANS PRIOR TO CONSTRUCTION. WHERE LOT LINES ARE NOT KNOWN OR CANNOT BE VERIFIED FROM SURVEY FIELD MARKERS, CONTRACTOR SHALL EMPLOY SURVEYOR FOR FIELD VERIFICATION OF PROPERTY LINE LOCATIONS PRIOR TO CONSTRUCTION. 16. CONTRACTOR SHALL NOTIFY LOCAL JURISDICTION AND ENGINEER FOR FIELD OBSERVATION OF SYSTEM INSTALLATION PRIOR TO BACKFILLING. 17. CONTRACTOR TO OBTAIN ALL NECESSARY PERMITS PRIOR TO START OF WORK. 18. CONSTRUCTION OF THE SANITARY DISPOSAL SYSTEM SHALL BE PERFORMED UNDER THE GUIDANCE OF A NEW YORK STATE LICENSED PROFESSIONAL ENGINEER. CERTIFICATION THAT THE INSTALLATION WAS MADE IN ACCORDANCE WITH THE APPROVED PLANS AND APPENDIX 75-A WASTEWATER TREATMENT STANDARDS FOR INDIVIDUAL HOUSEHOLD SYSTEM;; SHALL BE MADE TO THE NEW YORK STATE DEPARTMENT OF HEALTH AND THE LOCAL CODE ENFORCEMENT OFFICER. 19. CONTRACTOR TO REMOVE ALL COBBLES LARGER THAN 3"0 DIRECTLY BELOW TRENCH STONE. 20. NO WELLS ARE KNOWN TO EXIST WITHIN 100' OF THE PROPOSED ABSORPTION SYSTEM, 21. ALL TREES WITHIN 10 FEET OF THE SEPTIC AB80RPTION AREA ARE TO BE REMOVED. 22. CONCRETE SEPTIC TANK COVER OR TOP TO BE TRAFFIC RATED. 23. AT FOUNDATION WALL PENETRATIONS CONTRACTOR SHALL CORE DRILL OVERSIZED HOLEIN CONCRETE OR MASONRY FOR INSTALLATION OF HOUSE SEWER. HYDRAULIC CEMENT OR GROUT PIPE AND HOLE TO OBTAIN SMOOTH INTERIOR AND EXTERIOR FINISH TO MATCH EXISTING WALL FACES. INSTALL DAMPROOFING ON EXTERIOR FACE AFTER CEMENT OR GROUT IS DRY. SEPARATION DISTANCES FROM WASTEWATER SYSTEM COMPONENTS WELL OR TO STREAM, LAKE, (2) PT #2 SYSTEM COMPONENT SUCTION LINE WETLAND, WATERCOURSE DWELLING PROPERTY LINE HOUSE SEWER 280CAST-IRON PIPE STABILIZED RATE 1 MIN 07 SEC PER INCH _ (WATER -TIGHT JOINTS) 50' OTHER MATERIALS 25' 3' 10' SEPTIC TANK 50' 50' 10' 10' _ EFFLUENT LINE TO 2 DISTRIBUTION BOX _ 50' 50' 10' 10' DISTRIBUTION BOX 100' 100'(3) 20' 10' ABSORPTION FIELD 100'(1) 100'(3) 20' 10' SEEPAGE PIT 150'(1) 100' 20' 10' DRY WELL (ROOF a AND FOOTING DRAINAGE) 50' 100' 20' 10' RAISED OR MOUND SYSTEM (3) 100-(l) 100' 20' 10' NOTES: 7/8/2011 1. WHEN SEWAGE TREATMENT SYSTEMS ARE LOCATED IN COARSE GRAVEL OR UPGRADE AND IN THE GENERAL PATH OF DRAINAGE TO A WELL, THE CLOSEST PART OF THE TREATMENT SYSTEM SHALL BE AT LEAST 200 FT. AWAY FROM THE WELL. 2. MEAN HIGH WATER MARK DRAWN BY: 3. IF PERCOLATION RATE IS ZERO TO FIVE MINUTES PER INCH, THIS DISTANCE BECOMES 200'. Lu CONTRACTOR TO REMOVE EXISTING SEWER - TRUNK LINE ALONG SOUTH FDN WALL IN BASEMENT AND REPLACE WITH 4"0 SCHED. 40 PVC TRUNK SLOPED TO NEW OUTLET LOCATION. RECONFIGURE AND RECONNECT ALL EXISTING SEWER DROPS AND VENTS AT INTERIOR AS REQUIRED EXISTING HOUSE SEWER TO BE CUT AND CAPPED AT INTERIOR FDN WALL AND EDGE OF PORCH REMOVE REMAINING SEWER TO TANK 4f wow 300't PROPEL E EXISTING II TREES (TYP.) ` -- CLEANOUT TOto - TOTAL AR A - __ __ - GRADE - _ - - - 0.691 ARES INV. THRU FDV 0 `4f ` 1 - 1250 GAL. SEPTIC TANK, 96.6'± 1 1/2 STORY tr I CONTRACTOR TO LOCATEWOOD-FRAMED nQ I IN EXISTING CLEARING; 40 R-35 AT SFD o \ MINIMUM 50 FT TO WELL, MIPdIMUM 2% (BASEMENT) tr I INVERTIN 95.0'± GRADE RADE SLOPE, HOUSE s�� GRAD x 5 I INVE 4. 3'± F TO TANK V1 ± 98 T± f O \� I APPROXih%IATE I LOCATION OF 4"0 SDR -35 AT HOUSE I EXISTING MINIMUM 1% SLOPE, (' ADDITION Lu I I TREELINE TANK TOD-BOX ? (CRAWL T� } I j SPACE) k GRADE - LU II SA SA 96.8'± SA SA d *TH#1 SPT#3 x GRADE d I GRADE X #PT#2 96.7'± EXISTING WELL INSIDE ___..- I 6.6'± CRAWL SPACE OF , -++ I HOUSE ADDITION 0 I I D -Box - I INVERT* IN 94.4'±- I r ROPER LINE SETBACK "� .� a• I \ 10 M1 •___-- - too I - - - _� o APPROXIMATE moo dom .000 \ LOCATION OF ` �� OBSERVED OVERHEAD UTILITY LINES .,.. REQUIRED WELL W SEPARATION DISTANCE SEPTIC ABSORPTION FIELD �, 50 FT FOR SEPTIC TANK WITH MINIMUM (4) 41 FT ABSORPTION TRENCHES, CONTRACTOR TO LOCATE IN REQUIRED WELL EXISTING CLEARING; MINIMUM SEPARATION DISTANCE 100 FT TO WELL FROM ANY 100 FT FOR ABSORPTION ABSORPTION FIELD �., FIELD AND D -BOX COMPONENT OR D -BOX, AND MINIMUM 10 FT FROM PROPERTY LINE w \ v W tJ 0_�'LOTPLAN NOTE: REFERENCE ELEVATIONS SHOWN ARE IN REFERENCE TO ELEVATION 100.0'= TOP OF EXISTING BLOCK FOUNDATION WALL 2'X2' CONC. PAD I° I *PT#1 0 DRIVEWA a cc 0 CIE - J�• \ �/ i mo* SITE DATA PROJECT LOCATION: 39 BURCH ROAD, QUEENSBURY NY 12804 TAX ID NO.: 308.6-1-4 OWNER: JAMES VANDORAN SEPTIC SYSTEM DESIGN INFORMATION SOIL TEST DATA: PERCOLATION TESTING PT #1 STABILIZED RATE 1 MIN 29 SEC PER INCH PT #2 STABILIZED RATE 1 MIN 12 SEC PER INCH PT #3 STABILIZED RATE 1 MIN 07 SEC PER INCH COMPLETED ON: JUNE 28, 2011 AND AUGUST 11, 2011 BY VISION ENGINEERING, LLC AND WITNESSED BY CHAZEN COMPANIES DEEP TEST HOLE: 2 DEPTH: TYPE: TH #1 0 - 10" TOPSOIL '10 - 21" ORG BRN FINE SANDY LOAM 21 - 37" PALE BRN FINE SANDY LOAM 37 - 84" GRY BRN FINE SAND NO GROUNDWATER OBSERVED IN TEST HOLE MOTTLING OBSERVED AT 60 INCHES NO BEDROCK OBSERVED IN TEST HOLE COMPLETED ON. AUGUST 11, 2011 BY VISION ENGINEERING, LLC AND WITNESSED BY THE CHAZEN COMPANIES SEPTIC SYSTEM DATA: NO. OF BEDROOMS: TYPE OF SYSTEM: NO. GALS. PER BEDROOM: DESIGN FLOW RATE: MINIMUM SEPTIC TANK CAPACITY: DESIGN PERCOLATION RATE. TOTAL LENGTH OF TRENCH REQ'D: TOTAL LENGTH OF TRE=NCH PROVIDED: APPROXIMATE LOCATION OF EXISTING SEEPAGE PIT (TO BE PUMPED, REMOVE AND DISPOSE OF TOP, AND FILL WITH CLEAN SAND FILL) po /1 ' APPROXIMATE LOCATION OF EXISTING 1000± GAL. SEPTIC TANK (TO BE PUMPED, REMOVE AND s DISPOSE OF TOP, AND FILLED WITH CLEAN SAND FILL) - APPROXIMATE LOCATION OF EXISTING SEEPAGE PIT (TO BE PUMPED, REMOVE AND DISPOSE OF TOP, AND FILL WITH CLEAN SAND FILL) GRAPHIC SCAT E 3 ABSORPTION TRENCH 130 GPD/BEDROOM 390 GPD 1000 GAL. (1250 GAL PROVIDE 1-5 MINA N. 162 FT 164 FT (USE MIN. (4) 41 FT TRENCHES) V CL w Mum. C ui Z It.142-O =ULtuv SEP 2 2 2011 BUILDING & CODES )hserved, or believe I saw evidence of, ses, wells, trees, fences, etc., t TOWN OF QUE BUILDING & R, viewed B Date: �_4 20 0 10 20 40 80 (IN FEET) 1 INCH = 20 FT. 0 N � � N N rn 00 CO N 04 0 Z ~ � L_ 00 r` co � 00 cu O X C� Li O W I- 0 W U W U) m W Z''. W x W a X W Ll J ALL FEDERAL, STATE, AND LOCAL CODES AND REGULATIONS SHALL BE CONSIDERED TO BE PART OF THE BUILDING DETAILS AND SPECIFICATIONS HEREIN. IF DISCREPANCIES BETWEEN THE CODES AND REGULATIONS AND THE INFORMATION CONTAINED ON THESE PLANS EXIST, THE MORE STRINGENT SHALL APPLY UNLESS THE INFORMATION SHOWN, DESCRIBED, OR IMPLIED IS A VIOLATION OF THE CODE; IN WHICH CASE THE CODE OR REGULATION SHALL TAKE PREFERENCE OVER PLANS. DIG SAFELY NEW YORK CALL BEFORE YOU DIG WAIT THE REQUIRED TIME CONFIRM UTILITY RESPONSE RESPECT THE MARKERS DIG WITH CARE SAFE DIGGING IS EVERYONES RESPONSIBILITY! PLEASE CALL 1-800-962-7962 BEFORE YOU DIG. VISIT www.digtafelynewyork.com FOR ADDITIONAL INFORMATION. IT IS A VIOLATION OF SECTION 7209 SUBDIVISION 2 OF THE NEW YORK STATE EDU ,ATION LAW I FOR ANY PERSON. UNLESS ACTING UNDER THE DIRECTION Ok A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ENGINEER IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. ENGINEERS STAMP: 21 0 o� c W c am C: a� c O LO N O c 0 U) U) O F &1j" Rj kJ t � pP IF THE STAM GN/STU T41S DRAV�IN A�2E OT IN BLUE INK THIS SE, 0 NSTR 0 U ENTS Y BE ILLEGAL COPY OR A M I DUPL F TH OIGINAL MENTS NOT CONTAIN! RI P SIGNULD NOT BE USED TO I A IN6 t R N& UCTION. 07 0 REVISIONS 5 4 3 J Z 2 ISSUED FOR CONSTRUCTION 8/12/11 Lu Lu W 1 ISSUED FOR REVIEW 8/4/11 z w PROJECT NO.: 576 a SCALE: AS NOTED co DATE: 7/8/2011 U) Z Z DRAWN BY: VISION Lu PROJECT: c JAMES VANDORAN � LL 39 BURCH RD, QBY tr u W o_ DRAWING TITLE uj u_ SEPTIC PLOT o .r PLAN o a W a o 0 mZ DRAWING NO. cr Z J L ®TING C=1 J C: = O zCO OF 2 aL Lj LLI INLET EN GROUND SURFACE 4" SDR -35 INLET (SLOPE 1/4" PER FT.) SANITARY TEE N z I v TOP VIEW �– LOCATION MARKER 1_77— —Il—I�1=)I �II — _— 1I I i ��� I 1, ;; U, ___F; 11=iii--Il 12"± LIQUID _ }11 _______LEVEL I INV. OF INLET 2" MIN. ABOVE INV. OF OUTLET W 0 0 d J 2' BAFFLES MAY BE USED INSTEAD OF SANITARY TEE OUTLET END ILL_ i1 IL COVER 4" SDR -35 OUTLET TO D -BOX (SLOPE 1/8" PER FT.) 8.i EFFULENT FILTER TO BE INSTALLED ZABEL OR EQUAL PRECAST SEPTIC TANK PROPERTY LINE 1 WELL ��— ---- -' STREAM_ POND OR LAKE WELL 1 0 1 MEAN HIGH WATER 1 1 I MARK/ELEVATION I I o 1 I 1 1 �o0 1 f z SEPTIC o TANK I N j I SEPTIC D -BOX TANK 1 — 1 D -BOX 1 1 I I I I I I I 1 II I I I I I I I I I 1 ABSORPTION FIELD z ABSORPTION FIELD LPROPERTY - LINE NOTES: 1. TILE FIELD TO BE 100' OR MORE FROM ANY LAKE, SWAMP, 3. DISCHARGE FOOTING, ROOF, AND CELLAR DRAINAGE AWAY DITCH, OR WATERCOURSE AND 10' OR MORE FROM ANY FROM SEWAGE SYSTEM. WATERLINE UNDER PRESSURE. 4. DISPOSAL FIELD SHALL BE CONSTRUCTED PARALLEL WITH 2. FOR SEWAGE PIPE BETWEEN HOUSE AND SEPTIC TANK CONTOUR LINES. USE DUCTILE OR CAST IRON PIPE, SCHEDULE 40 PVC WITH SOLVENT WELDED JOINTS, OR SDR -35 WITH GASKETTED JNTS TYPICAL SEWAGE DISPOSAL SEPARATION SCHEMATIC NOT TO SCALE MIN. 6" SAND OR PEA GRAVEL BED COMPACTED 1250 GALLON SEPTIC TANK DETAIL (NOT REQ'D. IN SANDY WELL DRAINED SOILS) SEPTIC TANK NOTES: NOT TO SCALE 1. THE MINIMUM DISTANCE BEI WEEN THE INLET AND OUTLET SHALL BE SIX FEET. 2. TANKS MUST BE WATERTIGHT, CONSTRUCTED OF DURABLE MATERIAL NOT SUBJECT TO CORROSION, DECAY, FROST DAMAGE, OR CRACKING. AFTER INSTALLATION, ALL SEPTIC TANKS SHALL BE ABLE TO SUPPORT AT LEAST 300 POUNDS PER SQUARE FOOT (PSF). 3. TANKS WITH A LIQUID DEPTH OF 48 INCHES OR MORE SHALL HAVE A TOP OPENING WITH A MINIMUM OF 20 INCHES. 4. TANKS SHALL HAVE INLET AND OUTLET BAFFLES, SANITARY TEES OR OTHER DEVICES TO PREVENT THE PASSAGE OF FLOATING SOLIDS AND TO MINIMIZE DISTURBANCE OF SETTLED SLUDGE AND FLOATING SCUM BY SEWAGE ENTERING AND LEAVING THE TANK. 5. THERE SHALL BE A MINIMUM OF ONE INCH CLEARANCE BETWEEN THE UNDERSIDE OF THE TOP OF THE TANK AND THE TOP OF ALL BAFFLES, PARTITION AND/OR TEES. 6. TANKS SHALL BE PLACED ON AT LEAST A SIX INCH BED OF SAND OR PEA GRAVEL WHEN IN CLAY OR LOAMY SOILS. 7. THERE SHALL BE A MINIMUM DROP IN ELEVATION OF TWO INCHES BETWEEN THE INVERTS OF THE INLET AND OUTLET PIPES. 8. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4000 POUNDS PER SQUARE INCH (PSI) AT 28 DAYS SET. 9. WALL THICKNESS SHALL BE A MINIMUM OF THREE INCHES UNLESS THE DESIGN HAS BEEN CERTIFIED BY A NEW YORK LICENSED PROFESSIONAL ENGINEER AS COMPLYING WITH ALL APPROPRIATE REQUIREMENTS FOR THIN-WALL CONSTRUCTION. ALL WALLS, BOTTOM AND TOP SHALL CONTAIN REINFORCING TO ASSURE SUPPORT FOR 300 PSF. 10. ALL JOINTS SHALL BE SEALED SUCH THAT THE TANK IS WATERTIGHT. JOINTS BELOW THE LIQUID LEVEL MUST BE TESTED FOR WATERTIGHTNESS PRIOR TO BACKFILLING. 11. TANK SIZED FOR 4 -BEDROOM HOUSE WITH NO SPA OR WHIRLPOOL TUB. 12. PRECAST SEPTIC TANK BY FORT MILLER CO., INC. OR EQUAL. 1. SEE TYPICAL ABSORPTION TRENCH DETAILS FOR INFORMATION NOT SHOWN STANDARD ABSORPTION 4 -TRENCH DETAIL NOT TO SCALE —PVC THREADED CAP FINISHED GRADE i ll =iii 1f- 111 -III -11{ -- _ I� 111 III' i -=- =-j ill II � .- Iii I_I illlil =111-Ii1=1{I—-III III I []--1 A11 II771 I 1111-1 4" RISER AS REQUIRED 45° BEND 4" WYE TO SEPTIC TANK FROM HOUSE CLEAN-OUT DETAIL NOT TO SCALE 2 N r - Z_ io cV r Z' 0 (V 4" TOPSOIL MOUND FOR SETTLING LANDSCAPE FABRIC, RESIN PAPER, OR GEOTEXTILE FABRIC (FULL 2 FT. WIDTH OF TRENCH) 4" DISTRIBUTOR PIPE - 6'-0" O.C. NATURAL SOIL SUBGRADE IMPERVIOUS SOIL LAYER, OR EVIDENCE OF HIGHEST LEVEL OF GROUND WATER TRENCH WIDTH TYPICAL LEACH FIELD SECTION NOT TO SCALE 20" 0 INLET LJ 5 OUTLET _ _ J DIST. BOX �4" HIGH DENSITY POLYETHYLENE PIPE SEALS AT ALL CONNECTIONS CONCRETE OR STONE MARKER ABOVE ALL BURRIED COVERS RECOMMENDED. GRADE— �_iI- 6"-12" COVER 04INSPECTION COVER �- INLET BAFFLE 4. FORCE MAIN FROM �., PUMP STATION 4"0 OUTLETS W/ HIGH DENSITY POLYETHYLENE PIPE SEALS AND SPEED c° COMPACTED LEVELLERS AT EACH SAND OR GRAVEL OUTLET SECTION VIEW DB5 DISTRIBUTION BOX NOT ,fC SCALE DISTRIBUTION DEVICE NOTES: 1. MINIMUM SLOPE OF EACH OUTLET PIPE SHALL BE e INCH PER FOOT. 2. DISTRIBUTION BOX KNOCKOUTS TO HAVE HIGH DENSITY POLYETHYLENE PIPE SEALS. 3. THE DISTRIBUTION BOX SHALL HAVE A REMOVABLE COVER NOT MORE THAN 12 INCHES BELOW GRADE. WHERE, DUE TO SITE CONDITIONS A DISTRIBUTION BOX MUST BE GREATER THAN 12 INCHES BELOW THE SURFACE, AN EXTENSION COLLAR SHALL BE INSTALLED TO WITHIN 12 INCHES OF THE SURFACE. 4. ALL OUTLETS FROM THE DISTRIBUTION BOX SHALL BE AT THE SAME LEVEL, AND HAVE THE SAME SLOPE FOR THE FIRST 4 FEET WITH SPEED LEVELERS TO INSURE THE EVEN DISTRIBUTION OF FLOW. 5. DISTRIBUTION BOXES MUST BE SET ON A BED OF SAND OR PEA GRAVEL AT LEAST 6 INCHES THICK WHEN IN CLAY OR LOAMY SOILS. 6. THE DROP BETWEEN INLET AND OUTLET INVERTS SHALL BE AT LEAST TWO INCHES. A BAFFLE IS REQUIRED AT THE INLET SIDE OF THE BOX. 7. THERE SHALL BE A MINIMUM TWO INCH CLEARANCE BETWEEN THE INVERTS OF THE OUTLETS AND THE BOTTOM OF THE BOX. 8. PRECAST DISTRIBUTION BOX BY FORT MILLER CO., INC. OR EQUAL. NOTE: LENGTH AND LAYOUT OF FIELD SHALL BE BASED ON ATTACHED DESIGN SEE NOTES AND SCHEDULES FOR INFO NOTES: 1. ENDS OF ALL DISTRIBUTOR PIPES MUST BE CAPPED OR PLUGGED 2. ALL LATERALS TO BE OF EQUAL LENGTH. 3. INSTALL LATERALS PARALLEL WITH CONTOURS LEACH FIELD PROFILE NOT TO SCALE J' CL w J 0 04 04N N 00 N O) cp Z 0 N L 00 LL c N 0 X � CO aL LL W U W W Z W w a Lu ALL FEDERAL, STATE, AND LOCAL CODES AND REGULATIONS SHALL BE CONSIDERED TO BE PART OF THE BUILDING DETAILS AND SPECIFICATIONS HEREIN IF DISCREPANCIES BETWEEN THE CODES AND REGULATIONS AND THE INFORMATION CONTAINED ON THESE PLANS EXIST, THE MORE STRINGENT SHALL APPLY UNLESS THE INFORMATION SHOWN, DESCRIBED, OR IMPLIED IS A VIOLATION OF THE CODE, IN WHICH CASE THE CODE OR REGULA FION SHALL TAKE PREFERENCE OVER PLANS. DIG SAFELY NEW YORK CALL BEFORE YOU DIG -WAIT THE REQUIRED TIME CONFIRM UTILITY RESPONSE RESPECT THE MARKERS DIG WITH CARE SAFE DIGGING IS EVERYONES RESPONSIBILITY! PLEASE CALL 1-800-962-7962 BEFORE YOU DIG. VISIT www.diggafelynewyork.com FOR ADDITIONAL INFORMATION. IT IS A VIOLAtION OF SECTION 7209 SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW FOR .ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ENGINEER IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. ENGINEERS STAMP: rn 0 c c c c O D m 0 a� c O U) 0) REVISIONS z 5 4 c 3 2 ISSUED FOR CONSTRUCTION 8/12/11 LL 1 ISSUED FOR REVIEW 8/4/11 `; PROJECT NO.: 576 SCALE: AS NOTED DATE: 7/8/2011 DRAWN BY: VISION k PROJECT: g h JAMES VANDORAN 39 BURCH ROAD, Q13Y s c DRAWING TITLE o u 0 SEPTIC DETAILS I DRAWING NO. DWG C-� 0 u OF 2 IF THE STAMP N THIS DRAW1 FN IN BLUE INK, THIS SET 00 RDOCUMENTS MAYS EM.ILLEGAL COPY OR A MODIF ED D LI E OF TH ORIGINAL DpCUMENTS NOT CONTAINING GI S SI RE HOULD NOT BE USED TO OB BUI G P FOR CO TRUPTION. �c 079 REVISIONS z 5 4 c 3 2 ISSUED FOR CONSTRUCTION 8/12/11 LL 1 ISSUED FOR REVIEW 8/4/11 `; PROJECT NO.: 576 SCALE: AS NOTED DATE: 7/8/2011 DRAWN BY: VISION k PROJECT: g h JAMES VANDORAN 39 BURCH ROAD, Q13Y s c DRAWING TITLE o u 0 SEPTIC DETAILS I DRAWING NO. DWG C-� 0 u OF 2