2011-284 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building & Codes (518) 761-8256
CERTIFICATE OF COMPLIANCE
Permit Number: P20110284 Date Issued: Tuesday, July 129 2011
This is to certify that work requested.to be done as shown by Permit Number. P201102.84
has been completed.
Tax Map Number: 523400-316-010-0001-028-000-0000
Location: 12 ARBERGER Dr
Owner: CHERYL WINSLOW
Applicant: CHERYL WINSLOW
This structure maybe occupied as a:
Deck
By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Compliance DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan, "
Variance, or other issues and conditions as a result of approvals by the Director.of Building&code Enforcement. -
Planning Board or.Zoning Board of Appeals.
TOWN--OF.QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902'. (518)761-8201
Community Developnient-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20110284 Application Number: A20110284 .
Tax Map No: 523400-316-010-0001-028-000-0000
Permission is hereby granted to: CHERYL WINSLOW
For property located at. 12 ARBERGER Dr
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Tne of Construction Value
Owner Address: CHERYL WINSLOW
RICHARD WINSLOW Deck $1,200.00
13 RUSH HOLLOW Ct Total Value $1,200.00
QUEENSBURY NY 12804-0000
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans&Specifications
2011-284
160 sq ft deck =
$50.00: PERMIT FEE PAID.-THIS PERMIT EXPIRES: Friday,June 22,2012
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the To of eens e June 22,2011:
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
' FFICE USE ONLY
_/.2S
TAX MAP N0. PERMIT N0. U. :;t'3" 011
j , ... ... ,..
FEE PAID BLDG,&CODES APPROVAL ; TOWN OF QUEENS'BURY '
ACCESSORY STRUCTURE BUILDING PERMIT APPLICATION
Use this application for any structure other than the Principal Structure (house) to include, but not limited to:
garage, shed, greenhouse, dock, deck, etc. Refer to Informational Brochure No. 3'.entitled Accessory Structures-
Sheds/Fences.
A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS. APPLICATION IS SUBJECT TO REVIEW BEFORE
ISSUANCE OF A VALID PERMIT. NO INSPECTIONS WILL BE MADE UNTIL TH.E APPLICANT HAS RECEIVED
A VALID BUILDING PERMIT.
OWNER: ✓fIL/Cl A-/41 <-!�/ /(/i1 j:L�I�� INSTALLER/BUILDER: SS/"l
ADDRESS: � ADDRESS: 13���y�SI- /tiC d A,� CA
PHONE NOS.7G,/-.3aa(-C11f: &dl x _ PHONE NOS. MOM -e-. -7 9
LOCATION-OF PROPERTY: Z-2 /7f Stfa e BUT. SUBDIVISION NAME:
LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: &n tpdre 4
HAS THERE BEEN A SITE PLAN REVIEW;VARIANCE OR SUBDIVISION APPROVAL? ❑YES OP NO
IF SO,INDICATE APPLICATION NO.AND DATE OF APPROVAL:
ESTIMATED COST OF CONSTRUCTION: $ ANY OTHER ACCESSORY STRUCTURES ON PROPERTY? /V 0
IF YES,PLEASE LIST:
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: yJMS/d � PHONE:
U ND PROPOSED
PROPOSED CONSTRUCTION 1 FLOOR 2 FLOOR TOTAL HEIGHT
SO.FT. SQ.FT. SQ.FT. FT.&IN.
OPEN PORCH /
DECK �t!r�Z) ' d
3 SEASON,COVERED OR ENCLOSED PORCH*
BOATHOUSE
BOATHOUSE WITH SUNDECK
DOCK
SHED
POLE BARN
DETACHED GARAGE(NO.OF CARS: )
OTHER ACCESSORY STRUCTURE:
*CONSIDERED FLOOR AREA & MUST COMPLY WITH FAR [FLOOR AREA RATIO].REQUIREMENTS IF THE
STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE.
To the best of my knowledge, the statements contained.in the.application, together with the plans
and specifications submitted, are a true and complete statement of all proposed work to be done
on the described premises and that all provisions of the Building Codes, the Zoning Ordinance,
and all other laws pertaining to the proposed work shall be complied with, whether specified or
noted, and that such work is authorized by the owner. Further, it is understood that I/we shall
submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested
by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed
surveyor, drawn to scale, showing actual location of all new
construction.
QUESTIONS? CALL 761-8256 OR EMAIL
Queensbury Building & Code Enforcement - Residential pnaf Inspection
Office No. (518) 761-8256 Arrive: am/p D art: 1 am/pm
Date.lnspection reques
t received: Inspector's Initials:
NAME: (dU p �'�S PERMIT#: C�(J
LOCATION: , i- DATE: — —
TYPE OF STRUCTURE:
Comments:
Yes No NIA
4" Building Number Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent throw 18 inches
Roof Complete/Exterio inish'Com
Platform at all exterior do
Handrail 4 or more risers A
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches.36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-1 50 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation/Insulation Certification/Sticker on Panel
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum W Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C 10 Temporary/Permanent
LABuilding&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised
January 7,2008; Revised 6/26/08;Revised 12/22/10
Foundation Inspection Report
Z%N
761-8256 Date Inspection request received: a-a ding 8t Code Enforcement Arrive: am/pm Depart:
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials://°'�R .�..
NAME: 0 1 n Low t.,) RMIT#: . l l
LOCATION: I A-,-fe-t el INSPECT ON: (o
TYPE OF STRUCTURE:
N
Footings ���(��
MA-
Monolithic Slab
Reinforcement in Place �-
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this Lwp2se on site.
Foundation/Wallpour i
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing i
Foundation Waterproofing
Footing Drain Daylight.or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
I
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
.R-
Rough Grade 6 inch drop within 10 ft.
L:\Buliding&Codes Forms\Building&Codes\Inspection-Foffn0bundatlon Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
ZIA
-
c--"aat %Iktj
-
� h �
NII
"I have seen or observed, or believe I saw evidence of,
shown on the document.
all obi cts such as houses, wells, trees, fences, etc., ® i
l also represent that I have
person ea red t e.dis anc set forth on the diagram."
SIGIvF U E DATE
- v R'
#-20
Arl
� I C
i t jj j
1'
CA,
4.`-^••.�._�Guni.4aYn'rk1%z?a9i+?t'W�:�t(n.4e�i,AN.'E:tl'..r.�Y-r,/s-��h�.�r!f.SDi:.I.�.]'ft:2Tk4i!ih..v.l:.:.�..�'.�.SLc::JT•-F='91 N.� J!fT'-'�¢t�
In
. ,a i J• 91
i .
j
9
c
to
east
�tit
a d °i
file:///tmp/beam_l.html
r ..
'FrM-
Beam Layout Level #1
' l
J
d
Label Length Post Count ost Spacing
1.5 9__ 3 ._ �._._._ _.._ _ 3 3/4 ___._. . _._............
s
{ , �4
I of I 05/24/2011 12:50 PM
file:///trap/joist_I.htnil
1
Material Cut List Level-#1
c
a
G
e c
Label ame ty. Length evels
ascia ......
'10' 45 S45 _
:B ascia F�45 S45
C eader 151611
D 9 muter Joist .�'`9"
_ 6,� ._... . _.
E oast _i l...
l of 1 05/24/2011 12:49 PM
Deck Design Report L/ file:///tmp/pmh.html
1
VV
Store#0641 /1� Project Quote
251 QUAKER RD. �� �( ll� ��JJ Date of Quote: Tuesday May 24, 2011
QUEENSBURY, NY 12804 RICK WINSLOW
(518) 798-9050 Project Number-
Salesperson:
1
I Fill
POR
a:
Below are the Specifications and Materials
that you have selected for your.deck:
Overview Number of Levels: 1 Footer Depth: 48"
Total Square Feet: 160 Live Load: 71 psf
Dead Load: 10 psf
...... _._. . -- __... .- -- -
Component Size Wood T e
Joists 2 x 8 op Choice Treated
Beams 2 x g Top Choice Treated
Posts 6 x 6 Top Choice Treated
_ Pressure Treated
Decking 5/4 x 6
Standard Decking
_.._._ .... ........ ._.._ .....
Railing Pressure Treated
_.. _
�Bench None
Lattice +None
1 of 4 05/24/2011. 12:50 PM
Deck Design Report file:///tmp/pmh.html
Footer Depth 48" Live Load 71 psf
Dead Load 10 psf
Today's estimated cost for materials in this design with options: $1,292.71
Pricingis valid until Thursday May 26, 2011
Y Y.
There are missing Components in your Deck Design Project Quote.
The price quoted does not reflect these components.
Missing Items:
Component QTY
RFB5 THREADEDROD not found -3
Material List
Lumber'Materials"
l� .... _ __ _ _ -
Item# Model Qty Descnption Usage
1
015195�2REAITEDCQ TOP CHOICE Beam
r�
0169115/4X6X12 SW TOP CHOICE ACQ op Rail
01704 Z/4X6X16"SW TOP CHOICE ACQ, op Rail
0 6 1 X4X8 ACQ .40 TOP CHOICE Railing Post
TREATED
1
1763 3 X4X12#2 .40 ACQ TREATED Railing Post
�66 87�6' TRU-FIT RAILS Hand Rail
_ _ _..
X8X10 ACQ TOP CHOICE
;92334 15 Cladding
REATED
6573 1 /4X6X16 STD ACQ TREATED
Deck
Planking
827 6X6X8#2 40 ACQ TREATED Post „
Other Materials
- _ ....__ : _Model:
Item # Qty.:Description Usage
i6X6 TZ 2 SIDE POST ANCHOR
6472 3 Footing to Post
_ PA66E-TZ
10385�: P15tONCRETE MIX 80#QUIKRETE Footing to Post
10150ECONCRETE FORM TUBE 12'X48" Footing to Post
- - - --
-1 3 RFB5_THREADEDROD not found Footing to Post
ai69264 ' I 'NAIL COMMON GALV 5 LB 16 D Footing to Post
16 9� 24 GALVWROUND WASHER 1/2 Post to Beam m
2 of 4 05/24/2011 12:50 PM
Deck Design Report file:///tmp/pmh.html
67358 j 12 1GALV CARRIAGE BOLT 1/2 X 10 Post'to Beam
7342 12 GALV 1/2 HEX NUT Post to Beam
rPLA�TE
TR ANCHOR, 6.5X1.5TZ DBL1993 1 26Joist Framing
.E
69138 8 AIL COMMON GALV 1LB 8D Joist Framing
JOIST HGR.NAIL 1 LB
68408 1 Dist Framing
1-1/2 NA111CD
t Framing
}TZ�SLANT JSTHGR 2X6-8
11624122 .I Jois
18GA(14479)
-- ...........
184956. 1 10DX1 1/2' NAIL 5 LB MC Joist Framing
;I
f � _ _ _ _ _ _.( _ _)._.. �yg
69262 ��1 INAIL COMMON GALV 5 LB 10 D lJoist Framing
1 5/16X2-3/8X4 TZ ANGL CLP
13087 4 Joist Framing
_ AC5 TZ
�� Olympic Maximum Waterproofing
l 12045 1 Deck Planking
7 �s . �Clear Sealant VOC
IC� - --:
11347 ; 120 i4X4 DECK POST TIE TZ (14360)., Railing Post
=6734140 GALV 3/8 HEX NUT Railing Post
� _
f41706 ;�_ 14 3/8" FLAT WASHER GALV (25) PP Railing Post
67 . 7353 40 GALV CARRIAGE BOLT 3/8 X 8 lRailing Post
67365 GALV LAG SCREW 1/2X 6 PostBmOrLedgec
Disclamer:This quote is an estimate and is valid until Thursday May 26,2011.Lowe's Price
Guarantee is applicable to individual material items only.Lowe's Price Guarantee does not apply to
the total design package as a whole as quantities within different designs may vary.
Warning:This may not be a final design plan.Variations in building codes,specific architectural {
considerations,or site conditions may require changes to this design.You are responsible for the 1
final structure,code verification,material usage,and structural safety of this design.Be sure to
check and verify the design with your architect,engineer and building inspector. l
Lowe's is a supplier of materials only.Lowe's does not engage in the practice of engineering,
architecture,or general contracting.Lowe's does not assume any responsibility for design, i
engineering,or construction;for quantities or sizing of materials for a general or specific use;for
quantities or sizing of materials;.for the use or installation of materials;or for compliance with any
building code or standard of workmanship.Always refer to information on fastener packaging for
use with pressure treated lumber. {
Note: It is recommended that joist that meet on top of beams should be spliced with gussets.The
gussets should be 2-by wood the same width at the joist and overlap by 6 inches on each side.
These gussets should be held in place with 12 16d galvanized nails.
Handling Precautions for Pressure-Treated Wood
Disposal: Dispose of treated wood by ordinary trash collection.Treated wood should not be burned
in open fires,stoves,fireplaces,or residential boilers because toxic chemicals may be produced as
part of the smoke and ashes.Treated wood from commercial or industrial use(e.g.,construction
sites)must be disposed of in accordance with state and Federal regulations,which may include
burning only in commercial or industrial incinerators or boilers Always refer to information on
fastener packaging for use with pressure treated lumber.
of 4 05/24/2011 12:50 PM