Loading...
2011-617 itiak TOWN OF QUEENSBURY 742 BayRoad,Queensbury,NY 12804-5902 (518) 761-8201 � � Q rY> Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20110617 Date Issued: Wednesday, October 24, 2012 This is to certify that work requested to be done as shown by Permit Number P20110617 has been completed. Location: 35 GARRISON Rd Tax Map Number: 523400-302-011-0001-038-000-0000 Owner: JOSEPH & ELAINE MIHINDUKULASURIYA Applicant: JOSEPH & ELAINE MIHINDUKULASURIYA This structure may be occupied as a: Residential Addition By Order of Town Board Residential Alteration TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. TOWN OF QUEENSBURY %vim 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20110617 Application Number: A20110617 Tax Map No: 523400-302-011-0001-038-000-0000 Permission is hereby granted to: JOSEPH&ELAINE MIHINDUKULASURIYA For property located at: 35 GARRISON Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: JOSEPH&ELAINE MIHINDUKULA Residential Addition $450,000.00 35 GARRISON Rd Residential Alteration QUEENS BURY,NY 12804 Total Value $450,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2011-617 1101 sq ft resdiential addition&2986 sq ft residential alteration $668.10 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday,December 29,2012 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Tow of ieensbuc; Thursday,December 29,2011 SIGNED BY for the Town of Queensbury. Director of Building&&de Enforcement 4tiNI r - 'I`� 17 1L)?FFICE USE ONLY 7TC."-)".C47-nE N (TAX'M P NO. PERMIT NO. t� 1 ���[ P,� lFEES: PERMIT U/b1• l hECREATION ENGINEERING 2 2011 ...t (If applicable) OWN OF OUEENSBURY PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPRdiag '4.69 "' PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. d APPLICANT/BUILDER: HHC() �^6l`>tk-tic i -rl OWNER: 1%1' _1C'`'- '�� ' fii 17, ! 1 I-�c(ct;ril �j ADDRESS: _� {Z C' C 1 Y k C"a c-C / /('; ADDRESS: 3 _`) i✓�-t r -1 5 c F-) (N--)c- a_ 4 ',II !25> irr - Lc e)E'{751'(ll PHONE NOS. `)1 , '%`7 C. - ? PHONE NOS. 513, 77 CONTACT PERSON FOR BUILDING &CODES COMPLIANCE I C fV\ IA 1 kre c 14 PHONE: f ( K ca..ci `k7C `f LOCATION OF PROPERTY:, .�") Phi. I'Y^ I `j F C 0 \ '3Ca- A HAS THERE BEEN A SITE PLAN REVIEW; VARIANCE OR SUBDIVISION APPROVAL? 'YES ❑ NO IF SO, INDICATE APPLICATION NO.AND DATE OF APPROVAL: f. 1Q1I 1 1 CL-e. .1 t-71 CC 11 PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT APPLY TO YOUR z CJ w u) PROJECT o cc O i-: O � J p I- = w � w ,I LL w Q O 0 o z LU 0 < Z � 0u I— U- d1o6 l'a /0I a7U.d SINGLE FAMILY •,\:-X_,, �t� 7 TWO-FAMILY - .291.j' 41 lo W '' MULTI-FAMILY (NO.of UNITS ) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER Town of Queensbury * Community Development Office * 742 Bay Road, Queensbury NY 12804 Revised 4/14/2010 IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST: (15; o C FUEL TYPE: 6- 4 -S HEAT TYPE: X71+ R,1 *HOW MANY FIREPLACE(S): NJ C AND/OR WOODSTOVES(S): K) C ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? !\i C IS THIS A HISTORIC SITE? 1\./1C' 11 n PROPOSED USE OF BUILDING OR ADDITION: OCC WI ft IL a 1 C S1-c � �j ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? �1 C ARE THERE EASEMENTS ON PROPERTY? AIC *Please complete a separate Application for"Fuel Burning Appliances &Chimneys"available in our office I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to th, above. Signed C, (te- 1/4 �`2�_��, Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Town of Queensbury* Community Development Office * 742 Bay Road, Queensbury NY 12804 Queensbury Building & Code Enforcement - Residential Final lrltpection Office No. (518)761-8256 Arrve: am/p Depart: ( I am/Pm Inspection request received: Inspector's Initials: ��,/� NAME: : _ , 17 L� PERMIT#: Jf (�/ LOCATION: _3 5 Pa DATE: / ,o TYPE OF STRUCTURE: Comments: Yes No N/A h f�S 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwe = == - : •' Interior Smoke 17ctors/ -. •• onoxide D= = _= Every level: Eve - •—•- . Outside every bedroo rea: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access,1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed property/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/' hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical;Energy Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0[Temporary/Permanent] L:1BuiIding&Codes Forms\Building&Codes\Inspection FomissResidential Final Inspection Form revised_100405.doc;Revised January 7,2008;Revised 6/26/08;Revised 12/22/10,Revised 04/13/11 Queensbury Building & Code Enforcement - Residential al Final Inspection v(/ Office No. (518) 761-8256 Arrive: am/pm rt: /pm Date Inspection request received: Inspector's Initials:tr NAME: , 1`I C�i'-(, PERMIT#: ll -69 f LOCATION: DATE: 9—A t—k 'TYPE OF STRUCTURE: R f-} Comments: Yes No NIA 4" Building Number Address visible from road Chimney Height/`B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet ' 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Wi in stairwells safety gI: 9 Interior Smoke rs/Carbon Monoxi _ •etectors Every level: Eve edroom: Outside every bedroom a: / Inter Connected: Battery backup: d Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents L,17--- Bathroom Fans,if no window Plumbing fixtures tJ 61 VC S2J Foundation insulation to floor/Sticker on Panel Duct work sealed properly/Blower Door Test Certification Q Floor truss,draft stopping finished basement 1,000 sq.ft. � Emergency egress below grade —f> i �V�`� `"– Gas Furnace shut-off within 30 feet or within line of site Pk Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating_ /� Low water shut-off boiler "�"� Relief Valve(s)installed I Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage Garage fireproofing/%hour fire door/door closer 7 Pit, -LnIZ__V L_ Gas Logs in Sealed or Glass Enclosure Final Electrical;Energy Saving Light Bulbs 50% ......-- Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required 0 Okay to issue C/C or C/O[Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection FornssResidential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08;Revised 12/22/10,Revised 04/13/11 ' 1 c1--cil -I G ax.,_ Rough Plumbing I Insulation Inspection Report Office No. (518)761-8256 Date Inspection request received: q)tk-'61°' Queensbury Building &Code Enforcement Arrive: am/pm Depa am/pm 742 Bay Road, Queensbury, NY 12804 lnspec;tor's Initials: _ til NAME: JAIt Lit\ALA___ �. PERMIT#: I 1 - ( 7 LOCATION: ?, ( e, k,--r-.. :Cd INSPECT ON: /mil 37 7/ / TYPE OF STRUCTURE: IRO Meit., D1 , _c_7 u r\ Y N N/A ough Plumbi / 'I Plates I Vents in Place 1 14 inch minimum Drain Size Washing Machine Drain 2 inch minimum _ _ Cleanout every 100 feet/change of direction - , Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes , Pressure Test Water Supply Piping Air/Head 15 minutes ,, Insulation esidential Check/Commercial Check 1;4 b or Similar Exterior Sealant Proper Vent, Attic Vent 0...•, /Window Sealed tnsuiation) OP Hot Water Pip' insulation 2 required unheated -‘-2 Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: f_g,v - f°111`k-----: i,UK2K21-)S (U.-- ' 2- 1S(-4 )7/50W,,I cr' --(431/4)-C-- I c (')Q r .4-. a q - Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 firs d6th oRou h PlumbingI Insulation Inspection- Report Office No. (518) 761-8256 Date Inspection request received: 5//// Queensbury Building &Code Enforcement Arrive: am/ m Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: DAN 'h �_ PERMIT#: //'' CQ l '7 LOCATION: 3 5 .3ctivuk:stst. , INSPECT ON: 5/4l/iA TYPE OF STRUCTURE: PRe, -i -d41+ 0 —rb rn. Y N N/A I -. g_�3a7 Rough Plumbing /Nail Plates �� Plumbing Vent/Vents in Place 1 %inch minimum Drain Size Washi Machine Drain 2 inch minimum fit' Cleanout every 100 feet I change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes 1-"V Insulation/Residential Check/Commercial Check T ek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape N) c' COMMENTS: Rough Plumbing insulation Report,revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart. pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: t\kv t'' M " PERMIT#: / to/ LOCATION: 3 5�(--QAA1.6., \ RSI INSPECT ON: TYPE OF STRUCTURE: �` t 4--ta •Wt`4-24 -Ait,c—d_ '“?_ - Y N INA COMMENTS: Framing Attic Access 221 , ' minimum r Jack Studs/ • =Bracing/ : • ,ing ---,kdj,kai----c_ Joist hangers Jadc Posts/ :in : = ms Exterior sheet! • : '_ , property 1 12*0.C. i Headroom 6 ft. ; in. ( i• �t Stairwells36 in. or more \_ Exterior Deck B - • !, ,k iit-e-GAM W Headroom 6 ft. 8 in Notches/Holes/ : =aring Walls Vi` CZA V--"( '6 Metal Strapping for otches Top - 1 'r4(w) 16 gauge(: 16D Haus . . . PCJ-S `� GDraft stopping 1,000 .ft.floor t �_ -- Anchor Bolts 6 ft. or = son center yi\lk, Ice and water shield 2 inches from :II Fire separation 1, 2, 3 „ r e>lrbA‘A,( -L_ A-Ca-Cli/ek- Fire wall 2, 3, 4 hour Firestopping Penetration sealed I • 16 inch insulation in cavity . Garage Fire Separation ` ' House side'A Inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. £ ve cc ' r`) 0` Ct57sf /below grade 5.0 sf grade 7(a. t� 2,c5 L:Building&Codes Forms-AI.DIBuilding&Code llnspection FormslFmming Firestopping Inspection Reportdoc Revised January 7,2008 /v — /A-urs Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart am/pm 742 Bay Road, Queensbury, NY 12804 Inspectors Initials:gokLar") • NAME: i I I PERMIT#: // c / LOCATION: r 5 17c:el" 5o INSPECT ON: TYPE OF STRUCTURE: Framing COMMENTS: Attic Access 22'x30"minimum f),Aa �� Jack Studs/Headers frait- Bracing/Bridging Joist hangers VN-C2.<-166 C12_C-- Jack Posts/Main Beams Exterior sheeting nailed properly j r---; 12"O.C. Headroom 6 ft. 8 in. ------��-- ---- --__.___ Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. • Notches/Holes/Bearing Walls ----------� M-------- Metal Strapping for Notches Top Plate 1 6(w) 16 gauge(8) 16D nails each sib Z- J`- �- = " Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft or less on center �. Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire waft 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (VV) 5.7 sf above/below grade 5.0 sf grade L:\Building&Codes Fonns-OLD Building&Codes Inspection FonnsiFreming Fin stcPpng Inspection Reportdoc Revised January 7,2008 Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: 4, )G j-e 1/ Queensbury Building&Code Enforcement Arrive: am/pmDepart: .._ am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: 411-) NAME: MUk'wcl G( PERMIT#: /I—L / 7 LOCATION: INSPECT ON: 3�;l TYPE OF STRUCTURE: - , j Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing \,/ for 48 hours following the placement of the concrete. ur ose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior I Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Bullding&Codes Forms\Buiiding&Codes\Inspectlon Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM 1-3 Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p Depart: /l —am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: ! `I7 NAME: f fl t IJ ` PERMIT#: (-6/7- ` LOCATION: 3s—(� y�;'Sc�� INSPECT ON: TYPE OF STRUCTURE: Comment N N/A Footings i Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place --_ Footing Dowels or Keyway in place , Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Budding&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: :z 9 0 , Queensbury Building&Code Enforcement Arrive: am/pm Dep. am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: +) 0 NAME: PERMIT#: . /-C2/ l LOCATION: 3 5 Ee1�S i---- INSPECT ON: / /i ti-!) aeft 4J-d/3- TYPE , /S- TYPE OF STRUCTURE: �tl t'_ ' U.c., 4Th i1 F3ii ' 1 h Commentt Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing V Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing i po y or we under slab // ,([...Backfill Approval i' Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior / It?wilt, Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspectlon Forms\Foundation Inspection Reportdoc Last printed 12/20/2005 9:24:00 AM