Loading...
2010-381 TOWN OF QUEENSBURY WON 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20100381 Date Issued: Friday, February 21, 2014 This is to certify that work requested to be done as shown by Permit Number P20100381 has been completed. Tax Map Number: 523400-253-003-0001-047-000-0000 Location: 20 KNOLLS Dr Owner: SALVADORE & PATRICIA RUSSO Applicant: SALVADORE & PATRICIA RUSSO This structure may be occupied as a: Septic Alteration Residential Test Pit/Perc Test Review By Order of Town Board OF Q ENSBUR Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. 11111 ` TOWN OF QUEENSBURY FoN 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20100381 Application Number. A20100381 Tax Map No: 523400-253-003-0001-047-000-0000 Permission is hereby granted to: SALVADORE &PATRICIA RUSSO For property located at: 20 KNOLLS Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: SALVADORE&PATRICIA RUSSO 20 KNOLLS Dr Septic Alteration Residential QUEENSBURY,NY 12804 Test Pit/Perc Test Review Total Value Contractor or Builders Name/Address Electrical Inspection Agency Plans &Specifications 2010-381 deep hole perc test- septic alt $225.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Saturday,August 13,2011 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To114 eensb , , F ida A_qgust 13, 2010 SIGNED BY cec for the Town ofb QueensurY Director of Building&Code Enforcement OFFICE USE ONLY _ __-_ _ TAX MAP NO. _ .- �v •; PERMIT N0. -� , APPROVALS: �� PERMIT FE. �`4 , � `-I ALS: ZONING TOWN CLERKo APPLICATION FOR SEPTIC DISPOSAL SYSTEMi : - A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS. PERMIT: PERMIT. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID OWNER: '' ct L/ ' "to \ . So INSTALLER: ►lc L.. T.e. . , ,A ADDRESS: C h 1 -) ADDRESS: 1110 s _a , - ,- PHONE NOS. C gl C PHONE NOS. to i— S f LOCATION OF INSTALLATION: YEAR BUILT NO.OF X COMPUTATION= BEDROOMS RESIDENCE INFORMATION. 1980 or older = TOTAL DAILY FLOW X 150 gallon per bedroom -e- BEDROOMS GARBAGE GRIN ER 1981 c � INSTALLED? % 1991 X 130 gallon per bedroom 1992-present X 110 gallon per bedroom r. SPA OR HOT TU PARCEL INFORMATION: INSTALLED? /_ ✓ TOPOGRAPHY: Flat roiling_ Steep slope %Slope ✓ SOIL NATURE: /, Sand _ Loam —.X___ Clay Other______ ✓ GROUNDWATER: At what depth? ✓ BEDROCK/IMPERVIOUS MATERIAL: At what depth? / DOMESTIC WATER SUPLY: Municipal Well_ _ (If,well: Water supply from any septic ✓ PERCOLATION TEST: Rate is system absorption is,1-LtLft.) r` ±li er minute per inch. (Test to be completed by a licensed professional engineer or architect. PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal ) 9 systems must be designed by a licensed professional engineer or architect(unless installed in a PlanningBoard TANK ,&=----) � & approved subdivision). /__5=____GALLON (MIN. SIZE IS 1,000 GAL.) Add 250 gallons to the size of the each garbage grinder, spa or whirlpool tub. septic tank for SYSTE TYPE: ❑ ABSORPTION FIELD (WITH NO. 2 STONE) Total length ❑ SEEPAGE PIT(S) ) How (WITH NO. 3 STONE ft Each trench X many? ALTERNATIVE SYSTEM Bed Size? or other type? ❑ HOLDING TANK SYSTEM Total required capacity? _„2__o___:__,_, sem_ ' Tank size? Number of tanks? NOTE: ALARM SYSTEM AND ASSOCIATED:.....................:.....:..................:....... i; APPROVED ELECTRICAL INSPECTION ELECTRICAL WORK MUST BE INSPECTED BY A TOWN AGENCY. PLEASE REVIEW LIST PROVIDED. • For your protection, please •• note that pursuant to Section 136-29 of the Code of the Town of rm.—L.-- permit .roe.,.�.._. permit or approval granted which is based Unnn �r ie. 04.,+—+-_. . failure t., Y,,.,i._ _ .. Town of Queensbury■ Building&Codes Enforcement Office•742 Bay Road■ Queensbury,NY 12804 DEEP HOLE/PERC TEST Request for Town Engineer Review Property Owner: 4-4/4-Ile /'/a 550 Phone: Property Owner's Address: 01.0 1(4 0/45 Location of Test: tii2 5,'7( Tax ID#: 3, 3-/-lf,6 *Applicant's Engineer: Acne-e Lhs ii7eer,hs Phone: Applicant's Agent: ii; (oeri r Pr Phone: 79 -;41_5 Additional Notes: 1.Reason for Request? New Septic System 71 Replacement Septic System Failed Septic System Subdivision Site Plan Review 2.Are Wetlands present? YES NO UNKNOWN *Note: Applicant is required to engage an engineer for design and testing of the system. The Town Engineer's responsibility is to witness system testing only. PLOT PLAN: Plot plan, to scale, to be submitted with application FEE S $200 Flat Fee Date Paid: g/.2/.26/ Check No.: 4b 1'f b. OR Fee to be determined during To Be Determined: Site Plan /Subdivision review process SIGNATURE: In carrying out the provisions of Article IV, the Local Board of Health or the enforcement officer may engage the services of a qualified professional consultant for expert review and recommendation arising from the carrying out of the provisions of Art. IV, including but not limited to the review of plans, specifications and reports, attendance at inspections, dye tests, deep hole test pits, septic related deep hole and percolation tests, system installations, and any other aspect of any matter contained in this Art. IV, and any costs incurred in such review shall be paid to the Town by the owner of the property before any approval can be granted under this Art. IV shall become effective within 30 days of presentment of an invoice for same, whichever is sooner. Such costs shall not exceed $1,500 without prior written notice to the party to be charged with same. My signature below indicates I have thoroughly read and understand the instructions, agree to the submission requirements and have completed the application. I also fully understand that additional engineering fees may be necessary per Town of Queensbury Local Law 136-14D. SIGNATURE OF APPLICANT: Date: SIGNATURE OF AGENT: CrL Date: __ Original (B&C File) Canary(Planning) Pink(Applicant) Gold (Town Clerk) S f i e P l4-- ,/ Septic Inspection Report Office No. (518) 761-8256 Date Inspection requ- -iv,• Queensbury Building &Code Enforcement Arrive: t2".-1-0a � � -••rt: am • i IP 742 Bay Rd., Queensbury, NY12804 Inspector's Initials: NAME: SO-A R 1.4 Ss o ien NO.: in—3 F I LOCATION: aKnvBI' bP CT ON: Z..--Z-) --14 RECHECK: Eanc. Comments and/or diagram Soil Type: Sand/ Loam/ Clay Type of Water: Municipal/ Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' +/ - Y N N/A [150'to well required if NO] Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field/ Pit Opening Sealed: Y N End Cap Y_ N Inlet/Outlet Pipes&Baffles Y N Manholes 12"or less below grade _Y_N [provide extension collar if Yes] Y N Location/ Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan _N Engineer Report and Asc'BQIf' Y N ETU Maintenance Contract _Y_N provided Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear S stem U Sta : Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved L:\Pam Whiting\2010\Building Codes Forms\Inspection Forms\Septic Inspection Report 03 29 10.doc NACE ENGINEERING, P.C. 169 Haviland Road, Queensbury,NY 12804 Phone-518-745-4400 Fax -518-792-851 February 21, 2014 Project#49321 Dave Hatin Code Enforcement Officer Town of Queensbury 742 Bay Road Queensbury,NY 12801 Re: Russo—20 Knolls Drive—Replacement Septic System Dear Dave: This letter is to inform you that we inspected the completed replacement septic system for the Russo residence located at 20 Knolls Drive in the Town of Queensbury on August 18, 2010. The replacement septic system as installed was for a four bedroom home and consisted of the existing 1250 gallon septic tank, new pump station & force main, new distribution box and a 20 ft wide by 35 ft long absorption bed constructed of 4" diameter perforated pipe & stone. The system conforms to the requirements of the approved septic system design. Please call me if you have any questions. Sincerely, Thomas R. Center Jr, P.E. COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Permit No. I(, c)_,]^ Cert. No 10 9 0 2 Cut-in Card No Owner -J ' �w /� I�/ Location Q2 a K�Vtic 4-5 ,`'L LzB/ Installation Consisting of 56-14167 PA's` A71"C-47 U r241---c f1 Poo/e-t-u�d� Installed By e S-41,d XrC/1— Lic.No. The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of mak' spections at any time, and if its rules are violated,the Company shall have the right to ev e thi cer' icate. (I Date F-23-7° INSPECTOR.........- y /%/2— Member N.F.P.A.,I.A.E.I. Septic Inspection Re I rt Office No. (518) 761-8256 Date Ins'- ionefigeQueensbury Building&Code Enforcement Arrive: I :, rt: a /•742 Bay Rd., Queensbury, NY 12804 Ins or's Initis P� NAME: 'E` IT NO.: 3 LOCATION: FS I SPECT ON: $ — I i"1C) RECHECK: Comments and/or diagram Soil Type: Sand/ Loam/Clay Type of Water: Municipal/ Well Water Al A�. 7a, Waterline separation distance ft. vu Well separation distance 1 fes, ft.* Other wells: __ ‘CD ft. Well Casing Length 50' + /- Y N N/A [150'to well required if NO] Absorption Field: Total length 12-C> ft. Length of each trench 4Q- ft. Depth of trenches ! %-k-Ft‘..1-0.1L3. ft.ft.c.) 06 Size of Stone Seepag Size: 7�=fix fir" Stone Size: Z Piping Size Type Building to tank Tank to [ ril�r - o�� 1-4" o t-Q? t✓t tJE. Distribution Box to Field/ Pit / y` __bs? OpeningN Sealed:CEN). �Ek' f Inlet/Outlet Pipes&Baffles —N Manholes 12"or less below grade _N [provide extension collar if Yes] Y N Location/ Separati Foundation to n ft. r 4X-77' I c,R Foundation to absorption Separation of Pits y ft. Conforms as per Plot Plan ✓Y_Nr Engineer Report and As-Built Y yr ETU Maintenance Contract _Y N provided Location of System on Property: Front Rear Sid- Right Sid- Midd - Front Middle Rear s -m Use Status* Approved Partial Approved and needs to be re-ins'- ed, please call the Building &Codes Office Disapproved L:\Pam Whiting\2010\Building Codes Forms\Inspection Forms\Septic Inspection Report_03 29 10.doc NACE ENGINEERING, P.C. 169 Haviland Road, Queensbury, NY 12804 Phone-518-745-4400 Fax -518-792-851 August 5, 2010 Project#49321 Dave Hatin Code Enforcement Officer Town of Queensbury 742 Bay Road Queensbury, NY 12804 Re: Russo—20 Knolls Drive—Replacement Septic System Dear Dave: On August 4, 2010, we performed a deep soil test pit and percolation test at the Russo residence located at 20 Knolls Drive in Queensbury. The tests were performed to the southeast of the existing residence in the location where construction of a replacement leach field is proposed. The current residence has an existing failed septic system which will be decommissioned upon completion and certification of the replacement system. The results of the testing are as follows: Test Pit Percolation Test 0 —2" Tosoil Stabilization percolation rate - 1" in 7 min., 23 sec. 2 — 12" Loamy Fine Silty Sand 12 —50" Fine Silty Sand with trace Clay No Mottling observed. No Groundwater observed. The 12 inch deep hole was presoaked and the test was run 4 times; at a depth of 6 inches, until it stabilized with three consecutive runs of 6:44, 6:56 and 7:23 respectively. The design flow for this 4 bedroom residence at 110 gpd per bedroom (440 gpd design flow), requires 629 sf of absorption bed. The replacement absorption system should be constructed as a shallow bed system and shall be no deeper than 3 inches into the existing soil. The absorption system will consist of the existing 1,250 gallon septic tank, a new pump station w/ force main, a new distribution box and 20 ft wide by 35 ft long absorption bed with 4 — 30 foot long absorption laterals located to the northeast of the existing residence. Please call me if you have any questions. Sincerely, �/ •' Thomas R. Center Jr, P.E. , . — 1 1 1 _........=. i . I j_____ [ i _ 3 i ---. _ ...._ . ----- i aul 4- A*ii i el I I ,, , i 1 it ! ; •:, NI_________J 1 Nsi --„,.... /". . , e/ 1 # iCitt ' , 1 40 yr i I , : . t , . i 1 "I have seen or observed, or believe I saw evidence of, 1 11 ,all objects such as houses, wells, trees, fence3 etc., :shown on this document. I alsu .:.,•, e-,ell-i 1.':::r: , .-,;_,,ve I personally measured tedist.:3flue, sei '-..., ti-, or: me c',iagram." -,__ SIGNATURE DATE _ * , NACE ENGINEERING, P.C. 169 Haviland Road, Queensbury, NY 12804 Phone-518-745-4400 Fax -518-792-851 August 5, 2010 Project# 49321 Dave Hatin Code Enforcement Officer Town of Queensbury 742 Bay Road Queensbury,NY 12804 Re: Russo—20 Knolls Drive—Replacement Septic System Dear Dave: On August 4, 2010, we performed a deep soil test pit and percolation test at the Russo residence located at 20 Knolls Drive in Queensbury. The tests were performed to the southeast of the existing residence in the location where construction of a replacement leach field is proposed. The current residence has an existing failed septic system which will be decommissioned upon completion and certification of the replacement system. The results of the testing are as follows: Test Pit Percolation Test 0 —2" Tosoil Stabilization percolation rate - 1" in 7 min., 23 sec. 2 — 12" Loamy Fine Silty Sand 12 —50" Fine Silty Sand with trace Clay No Mottling observed. No Groundwater observed. The 12 inch deep hole was presoaked and the test was run 4 times; at a depth of 6 inches, until it stabilized with three consecutive runs of 6:44, 6:56 and 7:23 respectively. The design flow for this 4 bedroom residence at 110 gpd per bedroom (440 gpd design flow), requires 629 sf of absorption bed. The replacement absorption system should be constructed as a shallow bed system and shall be no deeper than 3 inches into the existing soil. The absorption system will consist of the existing 1,250 gallon septic tank, a new pump station w/ force main, a new distribution box and 20 ft wide by 35 ft long absorption bed with 4 — 30 foot long absorption laterals located to the northeast of the existing residence. Please call me if you have any questions. Sincerely, Thomas R. Center Jr, P.E. ''-' ---,-37/77 ) „A --.= — i , 1,, , Lk,1 r\ . -r--- -> 4 : i ': 3 ------T i_______ , „____ r . -.) • --.. i .......,. t f--- 1 a oc' i , ec. f i --,......„2, w 1 fl ,\ . • .ry ' .. . 4eri'v- ' ' • i , 'I hive seen or observed, or believe I saw eviL,:1-_, 3-', ----1 31i f..:CAS Ad'', i:°;:s h:,::dses, wells, trees, te, .;ti,„,vn on tnis ;-..i : :it. I al: - ',. 1ty " i ' - ....:,.. i : - • . 'ik K Ay. /6 i ...... ----7 fi Ike i „.„„ * _,::: 3" #tv...,.. r.,. ._ , . ,., 4 4 '' * - i., _:-..:-:„.... I - ,., y- O n fl Dr. Q - : yr : ,: -:,fa 4, u . � ;. � � �� , = . , . -/: , ... t- ''.-" y 11i: I rt., '1* k „, 4. , - . io , _ 1 02�,; .t3 t,,. . . >� . 1 ' mt� s tct,r_^_A.,t: yua.2009 ,a ., ,,,,„,„2',,,p.3.1,7,4:7,-;. 34$7. I t