Loading...
2010-531 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building& Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20100531 Date Issued: Tuesday, November 15, 2011 This is to certify that work requested to be done as shown by Permit Number P20100531 has been completed. Location: 118 DIXON Rd Tax Map Number: 523400-302-014-0001-034-000-0000 Owner: CASEY L SCOVILLE Applicant: CASEY L SCOVILLE This structure may be occupied as a: Residential Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the ProPe3owner of the responsibility hfor compliance with Site Plan, c-1.)4(' Variance,or other issues and conditions as a result of approvals by the Director of Building&Code E orcem t Planning Board or Zoning Board of Appeals. " TOWN OF QUEENSBURY ION 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20100531 Application Number. A20100531 Tax Map No: 523400-302-014-0001-034-000-0000 Permission is hereby granted to: CASEY L SCOVILLE For property located at: 118 DIXON Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: CASEY L SCOVILLE 161 RIDGE ST. #2 Residential Alteration $5,000.00 GLENS FALLS,NY 12801-0000 Total Value $5,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency T. MARTIN CONSTRUCTION 18 FOUNDERS Way QUEENSBURY,NY 12804-0000 Plans &Specifications 2010-531 203 sq ft residential alteration $40.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Wednesday,November 09,2011 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the own Quefi bu , /TA. e ,November 09,2010 ay SIGNED BY \ for the Town of Queensbury. Director of Building&Code Enforcement , OFFICE USE ONLY R. '�;' TAX MAP NO. ��/ 1:, �`/ j/ PERMIT NO. �� !b OCT 21 2010 FEES: PERMIT 7 kl RECREATION ENGINEERING # '''1A/N OF (If applicable) , ,ti BUILDINGUEENSB ,Ry PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. Casey Scoville-Hammer APPLICANT/BUILDER: T. Martin Construction OWNER: & Eric Michael Hammer ADDRESS: 18 Founders Way, QBY ADDRESS: 118 Dixon Road, QBY 518-955-8042 (Cell) 518-307-6235 (Casey) PHONE NOS.518-798-4841 (Home) PHONE NOS. 518-926-9480 (Eric) CONTACT PERSON FOR BUILDING &CODES COMPLIANCE: Todd Martin PHONE:Same LOCATION OF PROPERTY: 118 Dixon Road, QBY HAS THERE BEEN A SITE PLAN REVIEW;VARIANCE OR SUBDIVISION APPROVAL? 0 YES IXI NO IF SO, INDICATE APPLICATION NO.AND DATE OF APPROVAL: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT p p E- APPLY TO YOUR OZ p 0 p u) O w PROJECT 1 OH OJH � a = = Q u) di ~ OOZ Q - vOu.. - Ion SINGLE FAMILY X 203 TWO-FAMILY MULTI-FAMILY (NO.of UNITS ) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER Town of Queensbury* Community Development Office * 742 Bay Road, Queensbury NY 12804 Revised 4/14/2010 IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: N/A ESTIMATED CONSTRUCTION COST: >$5, 000 FUEL TYPE: Kerosene HEAT TYPE: Hot Air *HOW MANY FIREPLACE(S):1-ExistAND/OR WOODSTOVES(S): 0 ZONING CATEGORY: NR ARE THERE WETLANDS ON THIS SITE? No IS THIS A HISTORIC SITE? No PROPOSED USE OF BUILDING OR ADDITION: Single-Family Residential ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? No ARE THERE EASEMENTS ON PROPERTY? Unknown "Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read a,D.d agree to the above. Signed Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Town of Queensbury* Community Development Office * 742 Bay Road, Queensbury NY 12804 Revised 4/14/2010 Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: BUILDING & CODES APPROVAL ZONING APPROVAL DATE DATE QUESTIONS? CALL 761-8256 OR EMAIL codes(a�queensbury.net Office Use Only VISIT OUR WEBSITE FOR MORE INFORMATION www.queensbury.net Operating Permit Issued: Yes No Occupancy Type: Construction Classification: Assembly Occupancy Limit: Special Conditions: Town of Queensbury* Community Development Office * 742 Bay Road, Queensbury NY 12804 042. Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518) 761-8256 Arrive: am/p D- - \ am/pm Date Inspection request rec ived: // /1/ , ti/ Inspector's Initials: NAME: . PE' IT#: �' LOCATION: . ✓ t -r DATE: 1111• TYPE OF STRUCTURE: .dpi Comments: Yes No N/A 4" Building Number Address visible from road � �j� Chimney Height/"B"Vent/Direct Vent Location _ _✓1 /14.<-),-\ Fresh Air Intake � 3 inch Plumbing Vent through roof minimum 18 inches ; ' cc ' Roof Complete I Exterior Finish Complete Platform at all exterior doors d\--E- -0 S Handrail 4 or more risers Guards at stairs,decks, patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches -14A4-411-- Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window'. - a e g azing Interior Smoke Detector Carbon Monoxide Detectors Every level: Ev-k Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation/Insulation Certification/Sticker on Panel Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Gam/ Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0[Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008; Revised 6/26/08; Revised 12/22/10 11/4 Queensbury Building & Code Enforcement - Residentia incl Inspection Office No. (5-18)761-8256 Arrive: am/pm Depart:_3y0 am/pm Date Inspection request received: Inspector's Initials: ll`"' ee.Vr__ NAME: SO t r; fr . .. PER IT#: I LOCATION: 1/ J c.- 2) DATE: I f TYPE OF STRUCTURE: Comments: Yes No N/A 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight - re/6(/ (J' r Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/ :f is. Monoxide Detectors_ Every level: Eve __. -_ : Outside every bedroom area: eD Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area / Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Y" ' Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade 1--"a Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler �`� "— Relief Valve(s)installed/Heat Trap/Water Temp 110 V /" Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched CBZCD1 Garage fireproofing/%hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical;En o G� Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification, if required Okay to issue C/C or C/0[Temporary/Permanent] L:\Building&Codes Forms\Building&Codes Inspection Forms1Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08; Revised 12/22/10,Revised 04/13/11 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Permit No. -53/..Cert. No 2 21 O Cut-in Card No. Owner p1444m"4 v Location // �1 1)/X 4J IZ—/2 ,�C� 4- '/ Installation Consisting of...Lam lr� 77-44i. 3 A-Er- P, . -1 9-95 Installed By...L riLic.No. The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of aking ins tions at any time, and if its rules are violated,the Company shall have the right to v this ce e./ Date /°-1 (/ INSPECTOR ` Member N.F.P.A.,I.A.E.I. atois Rough Plumbing / insulnnpion Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/p Depart: ( m/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: I. • NAME: it 41,t `i PERMIT#: /6 ' LOCATION: 9/ ;?e . _ /41r/ INSPECT ON: / w f//) TYPE OF STRUCTURE: iThc ` -A-A)0 Y N N/A Rough Plumbing/Nail Plates Plumbing Vent/Vents in Place 1 %inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air I Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping r/ 50 P.S.I for 1 minutes / Insulation I R idential Check I Commercial Check l = or =r Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Q - ur _ 3C ' L - --'CL> Rough Plumbing Insulation Report.revised Nov 17 2003,revised February 15,2005,revised January 7,2008 Framing I Firestopping Inspection Re&ri Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p�mmD_Depart m/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:6 ' / NAME: 1/6,iv-Aker- PERMIT#: LOCATION: )/S3-- h5x- y, INSPECT ON: l2 TYPE OF STRUCTURE: �! - 13,_ Framing COMMENTS: rA Access 22"x 30" minimum Jack Studs/Headers J Bracing/Bridging Joist hangers Jack Posts 1 Main Beams Exterior sheeting nailed properly 12'O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom eft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 'fs w 16 . .e 8 16D nails each side Draft stopping 1,000 sq. ft floor trusses Anchor Bolts 6 ft or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 6 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:1BuiWkrg&Codes Forms-OLD Bullding&Codeslinspedion FonnsFFraming Firestopping Inspection Repo,tdoc Revised Anxiety 7,2008 g i d:44 Ln PLOT PLAN. 0 lkok o V 5raw all:existing a prnpcsed:etNcfu : fndtoa#i3 Ihie=ettraka of alftrure ::and'lxaiidtr�g fromX11ropert •Met. E D.01 V i:OE.PROP T'Y UR:E J 111 z1 t - -- ` - . - ' f 1 rii�_i�i C " .'ter--Lr- w��ro " r`uw�wwn .r r • ' 17: 47a11111111111111 4 Ln ��� I .....,..... ; •(u Ci: 5. =t. .. ` CO al m �� ' •. .- 'M ,r, rlour (T�,.'o /A • 3� .1:-1-J4} . t I , ms u_ g. . i 1 li I Lt I �- - —— - _ _ - - - .. - _ — 4 1 `t, • ; - VAN itK ettOILI °' CC I f Y.,+�iiiii R a/2 IIIIIIIr 3111--.' . NEW 1!STORY ROO WINDOWS & DOORS �,� .� ',�� 1/ S �� and PORCH ENCLO URE-EXISTING111.11111 • in -. FOOTPRINT TO R 'AIN UNCHANGED. / C11 . MINNIE ,, -0 • ;IvA . 1 limig-- 6. VII 'Q.per_ J� , 40) _ . .. . ._ . ;::--iAil a ..,lg, %�i�1.011.i�i�I. r.�7[nj YF) J I I • • ' i V �. 1 Graphic Scale � !f„ II ts` - nemiy-Ftv8S7aarrFeel Town of Queensbury or!'�r- nity(,Dsveiopinemt e`f ite.'I 423 By-i3toadc Etiaeeuvsbury,iNV :fr 4; 1111 lti1►1� 1. FACSIMILE TRANSMITTAL To: Building & Codes Department From: E.M. Hammer Organization: Town of Queensbury Re: 118 Dixon - Building Permit Fax No.: 518-745-4437 No, of pages, including cover: 5 Date: Thursday, November 04, 2010 Time: �;67Piv1 Message: Dave Hatin, Director: Pursuant to your request for additional information, the following items are included with this Facsimile Transmittal for your review and approval of a Building Permit: • Inspection Checklist as provided by ResCheck (3 pages); and • Plot Plan showing existing setbacks (1 page). We trust this information to be sufficient for your use. Thank you. Signed, E.M. Hammer 118 Dixon Road Queensbury, NY 12804 Mob.: 518-926-9480 This message is intended for the use of the individual or organization to which it is addressed and may contain information that is privileged, confidential and exempt from disclosure under applicable law. If the reader of this fax is not the intended recipient, employee or agent responsible for delivery, you are hereby notified that any dissemination, distribution and/or copying of this transmittal is strictly prohibited. If you have received this fax in en-or,please immediately call 518-926-9480. 500/100d Wd6V:90 01-01 V AO 1510-E6L-815:xej sniaMar mons fEScheck Software Verskrrn 4.3.1 Inspection Checklist ceilings: J Ceiling 1:SYeer.is svieftsr.18-o.c.:.7x10.P-88.0 cavity insulation Corner tri --.� -�— -- Above-Grade _....._Above Grade Wane: LI vak 1:Wood frame,18"o.c.,Fl-19.0 r vi y Ir1$11irll0.yrl Comment - --. LI Wail c:W1304 game: 1 S'co.,R-19.0 cavity insuiation Comments. Witetdoeis: l Window t:Vinyl Frame.Double Pane.'.bfactrtr:t}.3nt For windows without laaelec ti-factors,describe features: :Pangs_Frame?yam -- .-Thennal Bank?___Yea Nc Comments: _ Doors: U Door 1:Giass.t3-iscror:0.:350 Comment:; — — Heating and Cooling Equipment: .l Furnace 1:Forced Hot Air:85 AFUE 3r riighar Make rid Model tiesrh>E`" Air Leakage: t .hinds,Penetrations,at-4 eU other such openings in the bu8diria envelope that are scwrc4 of air leetca9e are seated. l] k cense o lights are 1)Type;c mated.or 2)instated Inside an appropriate air-tight assembly with a 0.>"clearanr,e from combust e materiels.It not C rated,frxiuras ere ir;stsulEd with a 3'-aaaretios from Insulation. Vapor Retarder: • installed on tote warns ir-winter side ot 84t non-tented framed catlings,watts.and tiPors, Materials Ident ficatian and kr&taliation: O Materials and equipment era instead in at-co--dance with the rr'rarttttitottrars itetellation instructions. 0 Innen on is instat:ed 3n substantirt c ritaa with the surface being inearktled said in a Menne,'that achieves the rated R-value. • lilateriais end egiiorsent are identsled so that coY±sssile/x:a Cart be determined. ❑ Manufacturer manuals Tor ail inatasted beatify and cooling s tent and sr: rice water heating exl;apmern have been reed. J InsuteYan R•vauues.glanno U-rac:ors.anis heating est-imeu si'lclency are olesriy marked on the isvitding plans or specifications. Duct Insulation: • Supply ducts in uncc d tioned attics or outside the btalcing are ii suiatad to at least 1;1-11. -t Return ducts in urn ortoitivnad attics or outside the bulldtreg are:notated te at lees;A4. J Sup*ducts in uricenciitioned spaces are insulated to at toast Return ducts in unconditioned spaces(except mens )ars insulated to A-2.lnsu2on is not requited on return ducts in basements, Duct Construction: Li Ail ioins,seams.and connections are securely fastened with weld .gaskets:mastics(adhesives).;ratio-plus-smbedaed-fabs.or tapas.Tapes and maatica are.rated UL 181A or UL 1818. Prciect Titfa:Hammer Fiesiaence Fieuro date: 11WD3f10 Data`";ierlarres:C::tssersJatirgibkriectiments'.REScitedct-lamrrtet,Yoc Page 2 of 4 500/ZOOd Wd6V:90 OLOZ V ASN 1510-E6L-815!xei ani amar affirms • • CCa+i meesiy welded&oil iochirtg-type longitudinal joins end seams on OLrot3 operating at lase then iii.w.g.(500 Pa). :_j The!-1Vr C Sy:MOM t i de`!51 it carie for balamieg air and water systems. Temperature Controls: Each;vigil+!:g una has at seam one thermostat tat pie of autivriatical y sa}uerii j the stsace turrperat ire set point of tha iarga t ztrte. Electric Systems: Li Sete 8i4X:t ie Mars exist for cou-li dwallirfg i✓lnaPI$ce$: Fi:r►places are?nat:rited With sight ritln nen- rnbuatibie f ngslaea doors. Fireplaces have a source of r,cwrfaistn a)r,as recRired Dy the Fireplace vanen jcrion isi ns of the ei,lirting Cede of New Yo Sta:e.the Rssident of C widow York Stele or the New Yorir City Burkfing Cato a9 applimwa. Service Water Heating: i 3 WaTer netrisrs with vsr!cal 449a risees have a heat trap on both the inlet and a isei "less the water hewer.er''has ah irteorei rpt trap or :s part;,-f a arcaiatiN system, Clrce.ilatirsg riot Water SSyams: j Cite:Awi::not water pipes are ih ihated to the leveis ic1 TeVe t Heating and Cuoiing P rg t1 en: iWr t-1VAC,piping Convey*ttuiita above 105 degreee F or crailsrs fialcia bet *s_degrees F ars inscdazed to tree!awls in Tel*2. Swimming Pooi6: i� M hec eti s.werxnsrsg pools ha a sn ontoff dealer swig asd a cover urriess over 20%as the heating anergy is;tarn noni5epietatiie saufees.Foci p ei ?s have a erne dolt, Proi3Ct Teas: Harnrrn�r Retrarace _... Reeart date; 11,)W0 Data fi!an`mc C;Users\kiriebA:tocaurertra,RE6 ck1t•#arnr!ierrrcit Page g el 4 500/E00d Wd59:90 OIOZ P ^°N 1.510-E6L-OLS:xa. sJaiamor oll!Ao3g Table 1:Minimum insulation Thickness for Circe. Flit Water Pipes luaulation Tnicknosa in Incfeas by Pipe Slxas tort-Caeulating RuneuIs Ci cuiatirn gains and Runpu1s !iEatAd'�V41er liptst• i.3ptr.1.225' i,5"1,:2.0' Ovar2` Temperatura(•'F) 170-10 0.5 1,0 .... 1 2.0 — 140-189 0.6 0.5 1.0 1.5 100-1:',8 0.5 0.5 0.5 1,0 Table 2:Minimum invitation Thicket ;tsi HVAC Pipes Fluidaatp. __ Insulation Thickness in beast hy Moo Suri Piping System Typns Rout `Fl 2'Fcurouis 1'anC Less 1.25'to 2,0' 2.5=1.0 4. ... Heating Systems — — "--" Loin Presi ureiTaverzturs 201-250 1,0 1.5 1.5 2.0 Lam i e{t)Grature 12020G 0.5 1.0 1.0 1,5 Steam Concionsate(for teed wagert a'ty 1.0 1.0 1.5 2.0 lrboiing Systems Chilled Water,RehigerAnt and 4055 0,5 0,5 0,75 1.0 eri;18 Below 40 1 0 1.0 1.5 1,5 NOTES TO FIELD:(Sundial:,Department t Iy) Prniem Tile:iiammar Flusidence Repor daze: 11/03,')0 De'.a filename;C:',Ussrs3aine it(?OCtlfCles'riitRE-Ses!eckWa,' iliir.rck Pais C 4i C 500/V00d wd6V:90 0102 V AN L51O-E6L-8[9:xel S.121OM2f allooas