Loading...
2010-102 011111k TOWN OFQ UEENSBURY FOTO742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20100102 Date Issued: Thursday, September 30, 2010 This is to certify that work requested to be done as shown by Permit Number P20100102 has been completed. Location: 15 BURKE Dr Tax Map Number. 523400-302-005-0001-001-000-0000 Owner. QUEENSBURY MASONIC HISTORICAL SOCIE Applicant: QUEENSBURY MASONIC HISTORICAL SOCIETY This structure may be occupied as a: Commercial Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, f Variance, or other issues and conditions as a result of approvals by the Director of Building& .de E ement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY Flivo 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20100102 Application Number. A20100102 Tax Map No: 523400-302-005-0001-001-000-0000 Permission is hereby granted to: QUEENSBURY MASONIC HISTORICAL SOCIET For property located at: 15 BURKE Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: QUEENSBURY MASONIC HISTO 14 BURKE Dr Commercial Alteration $45,000.00 QUEENSBURY, NY 12804-0000 Total Value $45,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2010-102 NEWMEADOW SARATOGA SCHOOL- COMMERCIAL ALTERATION $50.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Friday,April 29, 2011 (If a longer period is requited,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Torrof eenstAry; ur day,April 29, 2010 SIGNED BY (( ` )�` l / _, for the Town of Queensbury. Director of Building : Code orcement 1. OFFICE USE ONLY TAX MAP NO. 1 PERMIT NO. 0/0- 02_ �� I r. FEES: PERMI�//I RE REATION ENGINEERING a' ���v, Ct PC H' iiii 1441? U -1 ?AO- 1 BU!!nt?“ .d :- UR, PRINCIPAL STRUCTURE: - APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT '� A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR __CO TRU TIO `_ APPLICANT/BUILDER: N,�,i, h4S-&ddw arc oaf �le�vS�]�Jr' oc'i l- !� WNER: {t v C:A k OC i e"� 100 Sa,rct`t'OCC{{ - Vi iv c:( J \� ADDRESS: 5tii A-5 !-ta Uta. N 12-0).0 ADDRESS: f 5 Bir D ri v Kti) 0-"6 t PHONE NOS. VIq q2._30.- PHONE NOS. 30 -`11 31 (41 43 lc/n r1- 6 CONTACT PERSON FOR BUILDING&CODESiCOMPLIANCE`: I)CiN/.1 iY_Y hee1I;PPHONE: 'j 1 S� $`let Q-i.3� LOCATION OF PROPERTY: 15�u(I(R-Ori ye- l C��V e-e.At )U v,'-{ LAI i 2?04 SUBDIVISION NAME: (r1\OL----- PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT z APPLY TO YOUR z 0 x ci O w 1- PROJECT p ~~Q p J o w ~ W 2� LL� cc w ¢ a�U ,� 5;., x l- O-z Li ppp - C! ci s-H OH �w- z ¢ -N Ncn 0u ,-u_ d2oil SINGLE FAMILY TWO-FAMILY MULTI-FAMILY (NO._) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER V LH 1/l0�' i oI IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS:I W fIVACI[ht. 5o..,tttn -Q .DCL O d ESTIMATED CONSTRUCTION COST:104'5 1 r) o FUEL TYPE: N a Q( `0.`J HEAT TYPE? t' /*HOW MANY FIREPLACE(S)l'1 6t._ AND/OR WOODSTOVES S: i'110------• � UU �'l l � ) ZONING CATEGORY: U I?-I C) ARE THERE WETLANDS ON THIS SITE? n 0 IS THIS A HISTORIC SITE? no PROPOSED USE OF BUILDING OR ADDITION: `0(.)1 Town of Queensbury•Community Development Office• 742 Bay Road, Queensbury,NY 12804 r ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? el 4 ARE THERE EASEMENTS ON PROPERTY? Yo "Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office • I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/ description of the work proposed, that all work will be performed in accordance with the NY State Builidng Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I /we are required to provide an as- built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have rea nd agree to the above. Signed/ k `_r V Director of Building&Codes: 761-8256(for questions QUESTIONS? CALL 761-8256 OR EMAIL regarding Building Permits, construction codes or septic codescaaueensburv.net systems) VISIT OUR WEBSITE FOR MORE INFORMATION Zoning Administrator: 761-8218(for questions regarding www•gueensburv.net required permits,the permit process,application requirements or to schedule an appointment) Permission is hereby granted to the above This application/proposed action described herein is Applicant to erect or alter the building described found to be in accordance with the zoning Laws of herein in accordance with said Application: the Town of Queensbury BUILDING&CODES APPROVAL ZONING APPROVAL DATE DATE Office Use Only Operating Permit Issued: Yes No Occupancy Type: Construction Classification: Assembly Occupancy limit: Special Conditions: Revised 9/22/09 Town of Queensbury•Community Development Office• 742 Bay Road, Queensbury,NY 12804 1111 -e- n . Commercial Final Ins 'on Report 777- Office No.: (518) 761-8256 Date InsPqlion request received: of o Queensbury Building&Code Enforcement Arrive: /f7• am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: 1� NAME: eZAJ 1,(N- Gi r 4 f)ct,ti� 00L- PERMIT#: (0 — 1 LOCATIO� ( S avn-I,4e bril a DATE: ci/3 07/U COMMENTS: Y N NA Chimney/'B'Vent/Direct Vent Location Plumbing Vent Through Roof 6'/Roof Complete Exterior Finish/Grade Complete 6"in 10'or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks Interior I Exterior Banisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq.ft All Doors 36 in.w/Laver Handles/Panic Hardware,if required Exits At Grade Or Platform 36(w)x44'(0/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18")Above Grade Floor Bathroom Watertight/Other Floors Okay Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System Fresh Mr Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 Y2 doors > 10%> 1000 sq. ft. %Hour Corridor Doors&Closers Firewalls/Fire Separation, 2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping,3,000 sq.ft.Wood Frame Attic Access 30"x 20"x 30'(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Signage/Shaft Sealed Handicapped = •• Grab Bars/Sinks/Toilets Handica• •=' = • /Parking Lot Signage Public Toilet -oom Handicapped Accessible Handicapped Service Counters, 34 in.,Checkout 36" Handicapped Ramp/Handrails Continuous/12 in.Beyond[Both sides] Active Listening System and Signage Assembly Space • Final Electrical/Flex Gas Piping Bonded Site Plan/Variance required Final Survey, New St uc ture/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway 4' Water Fountain or Cooler Building Access An Sides by 20'I Driveable Surface 20'wide / Okay To Issue Temp.or Permanent CIO ✓ Okay To Issue C/C L:1Building&Codes Formaluilding&CodesUnspection FonntACommercial Final Inspection Reportdoc Revised January 7,2008 Inspection for Permit to Occupy Fire Marshal's Office Request Rec'd Permit No. L G - �2- Town of Queensbury � S 742 Bay Road / Queensbury,NY 12804 Scheduled Inspection Date: ` I 1 0 Time: Phone: (518) 761-8206 Business Name: N t`u ( ( Ove S c i-r ckfL, Fax: (518) 745-4437 Location: / c 3 „KE sin( v C- Type of Inspection N/A Yes No EXITS: Exit Access Exit Enclosure COMMENTS Exit Discharge AISLES: Main Aisle Width Secondary Aisle Width EXIT SIGNAGE Sign-normal ic) Sign-battery Qt, ft_� EVAC signs in rooms /- M l_ TRUSS ID SIGNAGE 1--- V , \ oEMERGENCY LIGHTING S � FIRE EXTINGUISHER: Hung Inspection of extinguisher Q FIRE ALARM SYSTEM OIC Fan Shutdown / ma Fire Sprinkler System (FDC) Fire Suppression-kitchen Fire Suppression-Gas Islan .....�.... Generator P . t ' Hood InstallationIg l . "� orf Elevator t Interior Finishes t Storage 2 Compressed Gas � Clearance to Sprinklers l•4 _ E Clearance to Electrical — Electric Wiring Enclosed/Labeled * hid Combustible Waste ,„. ur,!... J Vehicle Impact Protection Knox Box F.D.Signage-Utility Rooms No Smoking Signs Maximum Occupancy Sign 06 -----''`\ Emergency Evacuation Plan Approved (If no other approvals apply,the B&C Office wilt iss the C ificate of Occupancy) Denied / call for Recheck '` 1` Inspected By: L:\FireMarshal\FM Forms Masters\permitto occupyform.doc \kik Commercial Final Inspection ;t port Office No.: (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: �am/p / Depart am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: : NAME: /'J 1 i • (J(,),_ S PERMIT#: /(')iO? /� j u r . Dr DATE: atcf /(o COMMENTS: Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish/Grade Complete 6'in 10'or Equivalent Interior 1 Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Baflisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers 7"I Treads 11" Vestibules For Exit doors>3000 sq.ft k•"//ei All Doors 36 in.wlLever Handles/Panic Hardware, if required ti� Exits At Grade Or Platform 36(w)x 44'(i)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18")Above Grade Floor Bathroom Watertight/Other Floors Okay Relief Valve,Heat Trap I Water Temp.110 Degrees Maximum Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 %doors > 10%> 1000 sq.ft. '/.Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping, 3,000 sq.ft.Wood Frame Attic Access 30"x 20"x 30"(h), Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Signage/Shaft Sealed Handicapped - - ,. •• Grab Bars/Sinks/Toilets � / Handicap•-• /Parking Lot Signage V 241 Public Toilet -oom Handicapped Accessible Handicapped Service Counters, 34 in., Checkout 36" SS" Handicapped Ramp 1 Handrails Continuous/12 in.Beyond Roth sides] Active Listening System and Signage Assembly Space Final Electrical/Flex Gas Piping Bonded Site Plan/Variance required Final Survey, New Structure/Flood Plain certification,if req. 6.4/44 �,,.� /✓�r.,�< As-built Septic System Layout Required or On File �r/ Building Number or Tenant Address on Building or Driveway 4' �.1.s3oef Water Fountain or Cooler Building Access AN Sides by 20'/Driveable Surface 20'wide Okay To Issue Temp. or Permanent CIO Okay To Issue C/C L:1Building&Codes Forms\Buiiding&Codes\Inspection FormslCommercial Final Inspection Reportdoc Revised January 7,2008 7/ 7-vsaio--) . Inspection for Permit to Occupy Fire Marshal's Office Request Rec'd Permit No. Iti' _/ 0 Z Town of Queensbury / 742 Bay Road `� 7 Z Queensbury,NY 12804 Scheduled Inspection Date: ® "/t� Time: 1 % Phone: (518) 761-8206 Business Name: !" *..' i 0 .5 Fax: (518) 745-4437 Location: /$ 8r1P'/i -- a I: Type of Inspection N/A Yes No EXITS: / Exit Access ,/ Exit Enclosure I COMMENTS Exit Discharge - v AISLES: ex (i- " 5-S:16 1- ( D � Main Aisle Width Ii/ 4 % �` • S NI S n Secondary Aisle Width ti/ � b EXIT SIGNAGE / Sign-normal Y Sign-battery / j / EVAC signs in rooms ✓ TRUSS ID SIGNAGE ^ i ki , rh/i w'v l7 wTr 1 145 EMERGENCY LIGHTING Q..,,n s4-) !C 1 1 L---- FIRE `'FIRE EXTINGUISHER: Hung /Z. Inspection of extinguisher ✓ FIRE ALARM SYSTEM Fan Shutdown ,/ C'Ci,,✓t pr. �.4 r 11E P k''‘-/Fire Sprinkler System (FDC) if, Fire Suppression-kitchen .// Fire Suppression-Gas Islan f Generator ` t)-- `[� SA-tU$ G h a 1 8 Hood Installation Elevator / L0 1 Ce-v-- Interior ecInterior Finishes 4 Storage Compressed Gas Clearance to Sprinklers Clearance to Electrical / Electric Wiring Enclosed/Labeled ,�/ Combustible Waste / i Vehicle Impact Protection s// Knox Box V/ F.D.Signage-Utility Rooms i! 1 C No Smoking Signs ✓ / �l.Aw Maximum Occupancy Sign / ,/ S 14 NO Emergency Evacuation Plan ►/ u Approved (If no other approvals apply,the B&C Office will issue the Certificate of Occupancy) u Denied / call for Recheck Inspected By: L:\FireMarshal\FM Forms Masters\permitto occupyform.doc Framing / Firestopping Inspection Report Z---/-1 /'f lo& Office No. (518)761-8256 Date 1 „ ' , Queensbury Building&Code Enforcement Arrive:^-., a A +'- , rt: r v r2 a 742 Bay Road, Queensbury, NY 12804 Inspector's Initial=. NAME: /I/e /"# ct_) P- -MIT#: /1 LOCATION: /5- ; 'r/cc› )rSPECT ON: — ,• 4Y12,,,,OF STRUCTURE: f. Y N N/A COMMENTS: Fn�g 22"x30" minimum C i,;N 17 y% \II 7 ‘1, -.1- -r:_ Jack Studs/Headers cP_\Th, 2 t`lo.S)'t-\C \O1. Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12”O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. ' • Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 'h(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall ' /+� r-Y : ion 1, 2, 3 hour / + re wall 2, 3, 4 hour rt iF fir/ Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:1Buiidirg&Codes Fors-OLD1Building&Codes lnspedion Fo.mssFranip Firestopping Inspection Repat.doc Revised January 7,2008 A & Rough Plumbing I Insulation Inspection Report G Office No. (518) 761-8256 Date Inspection reqiv Queensbury Building &Code Enforcement Arrive: ,eE) air p 742 Bay Road, Queensbury, NY 12804 inspector's Initial /0i NAME: D PER y #: /a11, 2_ LOCATION: X-. i er ( . INSPir CT ON: TYPE OF STRUCTURE: Y N/A R• ,h Piumbi • /Nail Plates Ire Plumbing Ve ► Vents in Place 1A'1nchh inimum Drain Size Washi ! Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check T ek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct I Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Reporirevised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firestopping Inspection RepoAr - Office No. (518)761-8256 Date 1 ,,,iiijr,,-'�'- �� �req • �i part: Queensbury Building&Code Enforcement Arrive: 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: i.1'v NAME: nJ ,frbSGL-) • ZMlT#: y ----2...._ LOCATI : /lc Rur'/ce.. hr NSPECT ON: FE OF STRUCTURE: •, -- N--* ., ,: - - o. F Y -AIM.1 COMMENTS: A ' 22"x 30" minimum Jack Studs/Headers c ) F= Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly ® �U 12"O.C. �� Headroom 6 ft. 8 in. Stairwells 36 in. or more \\-) \) .\_- ___ Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 'r4(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fizseparation 1, 2, 3 hour wall 2, 3, 4 hour FklAWIN011411, , Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade — L:1Buitding&Codes Forms-OLDDBuildinp&Codeslinepection FonnssFnening Fig Inspection Report.doc Revised January 7,2008 0fl' / % - Rough Plumbing 1 Insulation inspction Report Office No. (518) 761-8256 Date Inspectio - - .4_ 1 Queensbury Building &Code Enforcement Arrive: lei ! - : Rough Plumbing I Insula ion Ins f, ion Report Office No. (518) 761-8256 Date Ins. - 'on •ues re fed: Queensbury Building &Code Enforcement Arrive: ' c_ =m/p `' :'art: I©"A13-am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's In',als. NAME: A ea,0.6f,x.,- 4 fief, PER `T #: O 2 LOCATION: ,5"-- ar c-e /` INSP CT ON: TYPE OF STRUCTURE: _ Y en N/A Rou•h Plumbin• /Nail Plates Plumbing Vent l Vents in Place ■�■ 1 %inch minimum Drain Size Washin• Machine Drain 2 inch minimum Cleanout eve 100 feet 0 chane a of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes 411 - Test i =f- upply Piping i? • k15 minutes 4 ll i =ntial Check/Commercial Check T Tyvek or Sliar -nor Sealant El�� Yom' ' c)F�C--i..- • _ I ent, Attic Vent MN Door/Window Sealed (No Insulations P—_‘. ` VW Duct/Hot Water Piping Insulation If •uired unheated •aces ov--- 'V'LO Combustion Air Supply for Furnace Duct work sealed properly/No duct tape .! y 14111111111 COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 ct a s +0 l v -12_, Rough Plumbing I Insulation Inspection Report Office No. (518) 761-8256 Date Inspectio •r A e d: ji Queensbury Building &Code Enforcement Arrive: IA-, - • - e A :*art: ,� '' y • • 742 Bay Road, Queensbury, NY 12804Inspector's In' - ,r- NAME: N Qu/ m 4act3& 4 A 6 vi PER ' #: Z-0(0 - 42— LOCATION: ZLOCATION: j 5- r ke />/. . - )u 1€I /INSP T ON: . LIF b TYPE OF STRUCTURE: . Y NIA ough Plumbing /Nail Plates Keil= Plumbin• Vent/Vents in Place ' itrk1, /,rte 1 34 inch minimum Drain Size Mfg Washi • Machine Drain 2 inch minimum Cleanout eve 100 feet I chane of direction Ell MIN Pressure Test Drain/Vent Air,/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes 4 111 Pressure Test Wate. •• •• ••iping Air/ 11 50 •.-. •r 15 minutes Insulation/Residential Check/Commercial Check Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation �III � If •uired unheated •aces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 C 1 o 3-e- rc--) Z Framing / Firestopping Inspection Report t__ 1 Office No. (518)761-8256 Date I i.ie•: 5 j Z O Queensbury Building &Code Enforcement Arrive.: . r • , . -rt: f.= �.742 Bay Road, Queensbury, NY 12804 Inspector's `or's In - � ' NAME: k,,k) � , " I�6 QV11119 CcA"( P RMIT#: �> 01 Z LOCATION: / 8,-v e 4]r . -- ' Ou ` NSPECT ON: S 1 Q 71 OF STRUCTURE: )1 -2,-, i`',. -1-ZA3 :C.:\ V.C...4,-... 9 Y N N/A COMMENTS: - . ---) Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 6(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center ce and water shield 24 inches from wall ire separation 1, 2, 3 hour r" 4 hour Fi • . -. , Penetration-sWl 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\Building&Codes Forms-OLD Building&Codeslinspedion Femrs&Framing Firestopping inspection Reportdoc Revised January 7,2008